{"title":"electrical-and-electronic-testing","description":null,"products":[{"product_id":"loop-impedance-and-psc-tester-cem-dt-5301","title":"Loop Impedance \u0026 PSC Tester – DT-5301","description":"\u003cp\u003eThe \u003cstrong\u003eCEM DT-5301\u003c\/strong\u003e is a professional loop impedance and prospective short-circuit current (PSC) tester for electrical installation verification and fault finding. It combines low-resistance loop testing, direct PSC calculation and wiring-status checks in a compact handheld instrument.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLoop impedance ranges: 20 Ω, 200 Ω and 2000 Ω\u003c\/li\u003e\n\u003cli\u003e0.01 Ω resolution on the low loop range\u003c\/li\u003e\n\u003cli\u003eDirect PSC measurement up to 20 kA\u003c\/li\u003e\n\u003cli\u003e15 mA low-current loop measurement on the 2000 Ω range\u003c\/li\u003e\n\u003cli\u003eThree LEDs for checking wiring status\u003c\/li\u003e\n\u003cli\u003eVisual warning for reversed phase and neutral\u003c\/li\u003e\n\u003cli\u003eAutomatic lock-out if the internal test resistor overheats\u003c\/li\u003e\n\u003cli\u003eVoltage measurement from 50 to 250 V\u003c\/li\u003e\n\u003cli\u003eIEC 61010-1 CAT III 600 V safety rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical installation testing\u003c\/li\u003e\n\u003cli\u003eEarth-fault loop impedance checks\u003c\/li\u003e\n\u003cli\u003eProspective short-circuit current assessment\u003c\/li\u003e\n\u003cli\u003eSocket wiring verification and fault finding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e CEM DT-5301\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 20px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eLoop impedance ranges\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e20 Ω \/ 200 Ω \/ 2000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eBest resolution\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eProspective short-circuit current (PSC)\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eDirect reading up to 20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eLow-current loop test\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e15 mA on the 2000 Ω range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eWiring indication\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eLED wiring-status indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eProtection\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eOverheat lockout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eSafety rating\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eIEC 61010-1, CAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eDatasheet\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/DT-5301-1.pdf?v=1789871377\" target=\"_blank\" rel=\"noopener\"\u003eView the CEM DT-5301 datasheet \/ technical document\u003c\/a\u003e\u003c\/p\u003e","brand":"CEM","offers":[{"title":"Default Title","offer_id":68073691054309,"sku":"CEM-DT-5301","price":540.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/cem-dt-5301_e0013d44-d3c3-48f4-9ed9-7600cb3071d3.jpg?v=1794268296"},{"product_id":"digital-earth-resistance-tester-cem-dt-5300b","title":"Digital Earth Resistance Tester – DT-5300B","description":"\u003cp\u003eThe \u003cstrong\u003eCEM DT-5300B\u003c\/strong\u003e is a digital earth resistance tester designed for grounding and earthing measurements in electrical installations, industrial plants, telecommunications and power systems. It also provides earth-voltage, AC\/DC voltage and resistance measurement for field troubleshooting.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEarth resistance ranges: 20 Ω, 200 Ω and 2000 Ω\u003c\/li\u003e\n\u003cli\u003eBest earth-resistance resolution: 0.01 Ω\u003c\/li\u003e\n\u003cli\u003eEarth voltage measurement to 200 V\u003c\/li\u003e\n\u003cli\u003eAC voltage measurement to 750 V\u003c\/li\u003e\n\u003cli\u003eDC voltage measurement to 1000 V\u003c\/li\u003e\n\u003cli\u003eResistance measurement to 200 kΩ\u003c\/li\u003e\n\u003cli\u003eLarge dual LCD display\u003c\/li\u003e\n\u003cli\u003eTest Hold and automatic zero adjustment\u003c\/li\u003e\n\u003cli\u003eIEC 61010-1 CAT III 1000 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical installation earthing checks\u003c\/li\u003e\n\u003cli\u003eIndustrial grounding systems\u003c\/li\u003e\n\u003cli\u003eTelecommunications grounding\u003c\/li\u003e\n\u003cli\u003eElectrical traction and power-system maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSupplied accessories are specified by CEM as test leads, earth spikes, cables, carrying case and batteries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e CEM DT-5300B\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 20px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eEarth resistance ranges\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e20 Ω \/ 200 Ω \/ 2000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eBest earth-resistance resolution\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eEarth voltage\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eUp to 200 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eResistance\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eUp to 200 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eAC voltage\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eUp to 750 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eDC voltage\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eUp to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eSafety rating\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eIEC 61010-1, CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eDatasheet\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/DT-5300B-1.pdf?v=1789871379\" target=\"_blank\" rel=\"noopener\"\u003eView the CEM DT-5300B datasheet \/ technical document\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eGrounding-system commissioning and maintenance\u003c\/li\u003e\n\u003cli\u003eElectrical installation verification\u003c\/li\u003e\n\u003cli\u003eSubstation, tower and industrial earthing checks\u003c\/li\u003e\n\u003cli\u003eSoil-resistivity surveys for grounding design\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"CEM","offers":[{"title":"Default Title","offer_id":68073823928549,"sku":"CEM-DT-5300B","price":570.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/m4eyvjeyc9sd4cp22okgpzak9e07t02e.jpg?v=1794269825"},{"product_id":"clamp-on-earth-resistance-and-leakage-tester-cem-dt-9399","title":"Clamp-On Earth Resistance \u0026 Leakage Tester – DT-9399","description":"\u003cp\u003eThe \u003cstrong\u003eCEM DT-9399\u003c\/strong\u003e is a clamp-on earth resistance and leakage-current tester for checking grounding systems without disconnecting the earth conductor or installing auxiliary stakes. It is suited to substations, industrial plants, telecom sites, lightning-protection systems and solar installations.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEarth resistance range: 0.025 Ω to 1500 Ω\u003c\/li\u003e\n\u003cli\u003eResolution down to 0.001 Ω\u003c\/li\u003e\n\u003cli\u003eTrue-RMS AC leakage-current measurement from 4 mA to 40 A\u003c\/li\u003e\n\u003cli\u003eClamp-on measurement without disconnecting the grounding system\u003c\/li\u003e\n\u003cli\u003eSelectable filtering for improved measurement in electrically noisy environments\u003c\/li\u003e\n\u003cli\u003eMemory for up to 32,760 measurements\u003c\/li\u003e\n\u003cli\u003eBluetooth app connectivity for data transfer and reporting\u003c\/li\u003e\n\u003cli\u003eTFT colour display\u003c\/li\u003e\n\u003cli\u003eIP54 protection\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V \/ CAT III 1000 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical substations and industrial plants\u003c\/li\u003e\n\u003cli\u003eTelecommunications towers and data centres\u003c\/li\u003e\n\u003cli\u003eLightning protection systems\u003c\/li\u003e\n\u003cli\u003eSolar PV grounding\u003c\/li\u003e\n\u003cli\u003eGrounding-system maintenance and fault finding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e CEM DT-9399\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 20px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eEarth resistance range\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e0.025 Ω to 1500 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eBest resolution\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eAC leakage current\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e4 mA to 40 A, True RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eData logging\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eUp to 32,760 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eWireless connectivity\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eBluetooth app\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eTFT colour display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eIngress protection\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eSafety rating\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eIEC\/EN 61010-2-032, CAT IV 600 V \/ CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eDatasheet\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/DT-9399-1.pdf?v=1789871374\" target=\"_blank\" rel=\"noopener\"\u003eView the CEM DT-9399 datasheet \/ technical document\u003c\/a\u003e\u003c\/p\u003e","brand":"CEM","offers":[{"title":"Default Title","offer_id":68073824026853,"sku":"CEM-DT-9399","price":1490.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/01_bx8smh.jpg?v=1794269832"},{"product_id":"1000v-digital-insulation-resistance-tester-cem-dt-5505","title":"1000 V Digital Insulation Resistance Tester – DT-5505","description":"\u003cp\u003eThe \u003cstrong\u003eCEM DT-5505\u003c\/strong\u003e is a compact professional insulation resistance tester for commissioning, troubleshooting and preventative maintenance on motors, generators, cables, switchgear and other electrical equipment.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation test voltages: 125 V, 250 V, 500 V and 1000 V\u003c\/li\u003e\n\u003cli\u003eInsulation resistance measurement up to 4000 MΩ\u003c\/li\u003e\n\u003cli\u003e1 mA nominal insulation test current at rated voltage\u003c\/li\u003e\n\u003cli\u003eLow-resistance and continuity testing\u003c\/li\u003e\n\u003cli\u003eAC and DC voltage measurement\u003c\/li\u003e\n\u003cli\u003eAutomatic discharge of capacitive voltage after testing\u003c\/li\u003e\n\u003cli\u003eLive-circuit detection inhibits insulation testing when voltage above 30 V is detected\u003c\/li\u003e\n\u003cli\u003eData Hold and Min\/Max functions\u003c\/li\u003e\n\u003cli\u003eBacklit dual display with analogue bargraph\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V \/ CAT III 1000 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMotors and generators\u003c\/li\u003e\n\u003cli\u003ePower and control cables\u003c\/li\u003e\n\u003cli\u003eSwitchgear and distribution equipment\u003c\/li\u003e\n\u003cli\u003eElectrical installation maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e CEM DT-5505\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 20px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eInsulation test voltages\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e125 V \/ 250 V \/ 500 V \/ 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eUp to 4000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eLow resistance\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eContinuity test\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eVoltage measurement\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eAC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eSafety features\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eAuto-discharge and live-circuit detection above 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eLarge backlit LCD with analogue bar graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eSafety rating\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eIEC 61010-1, CAT IV 600 V \/ CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eDatasheet\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/DT-5505-1.pdf?v=1789871377\" target=\"_blank\" rel=\"noopener\"\u003eView the CEM DT-5505 datasheet \/ technical document\u003c\/a\u003e\u003c\/p\u003e","brand":"CEM","offers":[{"title":"Default Title","offer_id":68073824125157,"sku":"CEM-DT-5505","price":770.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/63783846.jpg?v=1794269839"},{"product_id":"5kv-high-voltage-insulation-tester-cem-dt-6605","title":"5 kV High Voltage Insulation Tester – DT-6605","description":"\u003cp\u003eThe \u003cstrong\u003eCEM DT-6605\u003c\/strong\u003e is a professional 5 kV high-voltage insulation resistance tester for motors, generators, cables, switchgear and other industrial electrical assets. Its wide test-voltage range and diagnostic functions make it suited to commissioning and preventative maintenance.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation test voltages: 500 V, 1000 V, 2500 V and 5000 V\u003c\/li\u003e\n\u003cli\u003eInsulation resistance measurement up to 60 GΩ\u003c\/li\u003e\n\u003cli\u003ePolarisation Index (PI) measurement\u003c\/li\u003e\n\u003cli\u003eAutomatic ranging and timed testing\u003c\/li\u003e\n\u003cli\u003eOutput-voltage and discharge-voltage indication\u003c\/li\u003e\n\u003cli\u003eAutomatic discharge after insulation testing\u003c\/li\u003e\n\u003cli\u003eVoltage-output warning function\u003c\/li\u003e\n\u003cli\u003e6000-count backlit digital display with bargraph\u003c\/li\u003e\n\u003cli\u003eAC\/DC voltage measurement and continuity function\u003c\/li\u003e\n\u003cli\u003eIEC 61010-1 CAT IV 600 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial motors and generators\u003c\/li\u003e\n\u003cli\u003ePower cables and switchgear\u003c\/li\u003e\n\u003cli\u003eElectrical plant maintenance\u003c\/li\u003e\n\u003cli\u003eHigh-voltage insulation condition checks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e CEM DT-6605\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 20px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eInsulation test voltages\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e500 V \/ 1000 V \/ 2500 V \/ 5000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eUp to 60 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e±5% rdg ±3 dgt; ±20% above 6 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eShort-circuit current\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eApprox. 1.3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eRated test current\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eApprox. 1 mA to 1.2 mA at specified load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eAC\/DC voltage\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e0 to 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eResistance \/ continuity\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e0 to 6000 Ω; buzzer at approx. 50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e6000 counts, backlit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eFunctions\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003ePI, auto-ranging, timer, auto-discharge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eSafety rating\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eIEC 61010-1, CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eDatasheet\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/DT-6605-1.pdf?v=1789871377\" target=\"_blank\" rel=\"noopener\"\u003eView the CEM DT-6605 datasheet \/ technical document\u003c\/a\u003e\u003c\/p\u003e","brand":"CEM","offers":[{"title":"Default Title","offer_id":68073824157925,"sku":"CEM-DT-6605","price":1120.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/f090e64f93b016c78f2187f4ee6e505f.jpg?v=1794269845"},{"product_id":"thermal-imaging-insulation-tester-and-multimeter-cem-dt-6509","title":"Thermal Imaging Insulation Tester \u0026 Multimeter – DT-6509","description":"\u003cp\u003eThe \u003cstrong\u003eCEM DT-6509\u003c\/strong\u003e is a multifunction professional tester integrating insulation resistance testing, a True-RMS digital multimeter and thermal imaging. It is designed for advanced electrical maintenance, EV and hybrid systems, HVAC equipment, motors, switchgear and renewable-energy applications.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation test voltages: 125 V, 250 V, 500 V and 1000 V\u003c\/li\u003e\n\u003cli\u003eInsulation resistance measurement up to 5000 MΩ on the current CEM specification\u003c\/li\u003e\n\u003cli\u003ePolarisation Index (PI) and Dielectric Absorption Ratio (DAR)\u003c\/li\u003e\n\u003cli\u003eIntegrated thermal imager for rapid hot-spot identification\u003c\/li\u003e\n\u003cli\u003eTrue-RMS AC\/DC voltage and current measurement\u003c\/li\u003e\n\u003cli\u003eResistance, capacitance and continuity functions\u003c\/li\u003e\n\u003cli\u003eHigh-resolution low-ohm measurement\u003c\/li\u003e\n\u003cli\u003eLow-pass filter for VFD applications\u003c\/li\u003e\n\u003cli\u003eBluetooth \/ USB data transfer and logging\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V \/ CAT III 1000 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEV and hybrid high-voltage systems\u003c\/li\u003e\n\u003cli\u003eMotors, transformers and switchgear\u003c\/li\u003e\n\u003cli\u003eHVAC compressor and winding diagnostics\u003c\/li\u003e\n\u003cli\u003eSolar PV insulation testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e CEM DT-6509\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 20px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eInstrument type\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e3-in-1 insulation tester, True-RMS multimeter and thermal imager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eInsulation test voltages\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e125 V \/ 250 V \/ 500 V \/ 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eUp to 5000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eInsulation functions\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003ePI \/ DAR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eMultimeter\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eTrue RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eThermal imaging\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eIntegrated thermal imager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eConnectivity\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eBluetooth and USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eSafety rating\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eCAT IV 600 V \/ CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eDatasheet\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/CEM-DT-6509-datasheet.pdf?v=1789871165\" target=\"_blank\" rel=\"noopener\"\u003eDownload the CEM DT-6509 datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"CEM","offers":[{"title":"Default Title","offer_id":68073824190693,"sku":"CEM-DT-6509","price":4360.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/01_x4qtr9.jpg?v=1794269850"},{"product_id":"multifunction-installation-tester-cem-dt-6650","title":"Multifunction Installation Tester – DT-6650","description":"\u003cp\u003eThe \u003cstrong\u003eCEM DT-6650\u003c\/strong\u003e is a professional multifunction installation tester with a 3.5-inch TFT display, designed for comprehensive verification of low-voltage electrical installations.\u003c\/p\u003e\n\u003ch2\u003eKey Functions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation resistance testing\u003c\/li\u003e\n\u003cli\u003eContinuity and low-ohm testing\u003c\/li\u003e\n\u003cli\u003eHigh-current and no-trip loop impedance testing\u003c\/li\u003e\n\u003cli\u003eRCD trip-time and operating-current testing\u003c\/li\u003e\n\u003cli\u003eEarth resistance measurement\u003c\/li\u003e\n\u003cli\u003ePSC \/ PFC prospective fault-current calculations\u003c\/li\u003e\n\u003cli\u003eVoltage, frequency and phase-sequence testing\u003c\/li\u003e\n\u003cli\u003eInternal data storage with USB \/ Bluetooth data connectivity on current versions\u003c\/li\u003e\n\u003cli\u003eCAT III 600 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInitial electrical-installation verification\u003c\/li\u003e\n\u003cli\u003ePeriodic safety testing\u003c\/li\u003e\n\u003cli\u003eDomestic, commercial and industrial electrical work\u003c\/li\u003e\n\u003cli\u003eElectrical fault finding and reporting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e CEM DT-6650\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 20px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e3.5-inch TFT colour display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eContinuity \/ low resistance\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eLoop impedance\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eIncluding no-trip mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eRCD testing\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eEarth resistance\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003ePSC \/ PFC\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003ePhase sequence\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eConnectivity\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eUSB \/ Bluetooth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eSafety \/ standards\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eCAT III 600 V; EN 61326 \/ EN 61010-1 \/ BS EN 61557\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eDatasheet\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/DT-6650-1.pdf?v=1789871376\" target=\"_blank\" rel=\"noopener\"\u003eView the CEM DT-6650 datasheet \/ technical document\u003c\/a\u003e\u003c\/p\u003e","brand":"CEM","offers":[{"title":"Default Title","offer_id":68073824223461,"sku":"CEM-DT-6650","price":2990.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/cem-dt-6650_78d7f16b-fc2c-4bd2-ba1c-17b69a71d0a7.jpg?v=1794269856"},{"product_id":"motor-and-phase-rotation-tester-cem-dt-902","title":"Motor \u0026 Phase Rotation Tester – DT-902","description":"\u003cp\u003eThe \u003cstrong\u003eCEM DT-902\u003c\/strong\u003e is a handheld motor and phase rotation indicator for checking three-phase sequence and determining motor-rotation direction during installation, commissioning and maintenance.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDetermines three-phase rotary-field direction\u003c\/li\u003e\n\u003cli\u003eDetermines motor connection and rotation direction\u003c\/li\u003e\n\u003cli\u003eNon-contact rotary-field indication\u003c\/li\u003e\n\u003cli\u003eRotary-direction voltage range: 1 to 400 V AC\u003c\/li\u003e\n\u003cli\u003ePhase-indication range: 120 to 400 V AC\u003c\/li\u003e\n\u003cli\u003eFrequency range: 2 to 400 Hz\u003c\/li\u003e\n\u003cli\u003eCAT III 600 V safety category\u003c\/li\u003e\n\u003cli\u003eIP40 protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThree-phase motor installation\u003c\/li\u003e\n\u003cli\u003eElectrical panel commissioning\u003c\/li\u003e\n\u003cli\u003ePump, fan and machinery maintenance\u003c\/li\u003e\n\u003cli\u003ePhase-sequence verification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e CEM DT-902\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 20px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eRotary-field direction\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e1 to 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003ePhase indication\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e120 to 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eFrequency range\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e2 to 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eMotor testing\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eMotor connection and rotation testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eNon-contact function\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eNon-contact rotary-field indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eIngress protection\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eSafety rating\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eIEC 61010 \/ IEC 61557-7, CAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eDatasheet\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/DT-902-1.pdf?v=1789871376\" target=\"_blank\" rel=\"noopener\"\u003eView the CEM DT-902 datasheet \/ technical document\u003c\/a\u003e\u003c\/p\u003e","brand":"CEM","offers":[{"title":"Default Title","offer_id":68073824714981,"sku":"CEM-DT-902","price":190.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/19897c_d.jpg?v=1794269862"},{"product_id":"cable-pipe-and-electrical-fault-locator-cem-la-1012","title":"Cable, Pipe \u0026 Electrical Fault Locator – LA-1012","description":"\u003cp\u003eThe \u003cstrong\u003eCEM LA-1012\u003c\/strong\u003e is a professional transmitter-and-receiver cable locator for tracing hidden electrical cables, locating circuit breakers and identifying interruptions or short circuits without opening walls or floors unnecessarily.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWorks with both live and de-energised cables\u003c\/li\u003e\n\u003cli\u003eTraces cables in walls and underground\u003c\/li\u003e\n\u003cli\u003eLocates fuses and circuit breakers on final circuits\u003c\/li\u003e\n\u003cli\u003eHelps locate cable interruptions and short circuits\u003c\/li\u003e\n\u003cli\u003eSuitable for tracing electrical floor-heating circuits\u003c\/li\u003e\n\u003cli\u003eCan trace metallic water and heating pipes\u003c\/li\u003e\n\u003cli\u003eDigitally coded transmitter signal for clear identification\u003c\/li\u003e\n\u003cli\u003eAutomatic or manual receiver-sensitivity adjustment\u003c\/li\u003e\n\u003cli\u003eReceiver displays signal level\/code and live-voltage indication\u003c\/li\u003e\n\u003cli\u003eIntegrated torch for work in dark areas\u003c\/li\u003e\n\u003cli\u003eReception depth up to approximately 2 m under suitable conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe kit includes a transmitter and receiver, with additional transmitters available for applications where multiple signals need to be distinguished.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e CEM LA-1012\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 20px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eCable status\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eLive or dead cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eTypical applications\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eWall\/underground cables, fuses, breakers, interruptions, short circuits, floor heating and metallic pipes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eSignal\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eDigitally coded transmitter signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eSensitivity\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eAutomatic and manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eLive-voltage indication\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eReceiver light\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eIntegrated torch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eReception depth\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eUp to approximately 2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eDatasheet\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/LA-1012-1.pdf?v=1789871377\" target=\"_blank\" rel=\"noopener\"\u003eView the CEM LA-1012 datasheet \/ technical document\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTracing concealed electrical cables and conductive pipes\u003c\/li\u003e\n\u003cli\u003eLocating circuit breakers and cable interruptions\u003c\/li\u003e\n\u003cli\u003eRenovation, maintenance and installation work\u003c\/li\u003e\n\u003cli\u003eFault finding in residential, commercial and industrial sites\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"CEM","offers":[{"title":"Default Title","offer_id":68073825304805,"sku":"CEM-LA-1012","price":810.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/CEM-LA-1012-Cable-Locator1.webp?v=1794269867"},{"product_id":"ac-leakage-current-clamp-meter-cem-dt-9810","title":"AC Leakage Current Clamp Meter – DT-9810","description":"\u003cp\u003eThe \u003cstrong\u003eCEM DT-9810\u003c\/strong\u003e is a compact AC leakage-current clamp meter designed for locating small leakage currents without disconnecting conductors. Its shielded 30 mm jaw and 0.1 mA resolution make it useful for electrical maintenance, appliance troubleshooting and earth-leakage investigations.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAC current ranges: 200 mA, 2 A and 200 A\u003c\/li\u003e\n\u003cli\u003eBest resolution: 0.1 mA\u003c\/li\u003e\n\u003cli\u003eShielded transformer jaw with approximately 30 mm opening\u003c\/li\u003e\n\u003cli\u003eDesigned to minimise influence from external magnetic fields\u003c\/li\u003e\n\u003cli\u003e2000-count digital display\u003c\/li\u003e\n\u003cli\u003eData Hold function\u003c\/li\u003e\n\u003cli\u003eAutomatic power-off\u003c\/li\u003e\n\u003cli\u003eIEC 61010-2-032 CAT III 300 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEarth-leakage fault finding\u003c\/li\u003e\n\u003cli\u003eElectrical installation maintenance\u003c\/li\u003e\n\u003cli\u003eAppliance and equipment leakage checks\u003c\/li\u003e\n\u003cli\u003eIndustrial and commercial electrical troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e CEM DT-9810\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 20px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eCurrent ranges\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e200 mA \/ 2 A \/ 200 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eBest resolution\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eJaw opening\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e30 mm \/ 1.2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e2000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eFunctions\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eData hold, auto power-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eSafety rating\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eIEC 61010-2-032, CAT III 300 V, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eDatasheet\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/DT-9810-1.pdf?v=1789871377\" target=\"_blank\" rel=\"noopener\"\u003eView the CEM DT-9810 datasheet \/ technical document\u003c\/a\u003e\u003c\/p\u003e","brand":"CEM","offers":[{"title":"Default Title","offer_id":68073825337573,"sku":"CEM-DT-9810","price":470.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/alicate_corrente_fuga_amperimetro_dt_9810_cem_lr_1200x12001-b09e624478505d907416632698066281-1024-1024.jpg?v=1794269872"},{"product_id":"1000a-ac-dc-true-rms-clamp-meter-cem-dt-9381a","title":"1000 A AC\/DC True-RMS Clamp Meter – DT-9381A","description":"\u003cp\u003eThe \u003cstrong\u003eCEM DT-9381A\u003c\/strong\u003e is a professional 1000 A AC\/DC True-RMS clamp meter with VFD filtering and inrush-current capture for industrial electrical maintenance and troubleshooting.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAC and DC current measurement up to 1000 A\u003c\/li\u003e\n\u003cli\u003eAC\/DC voltage measurement up to 1000 V\u003c\/li\u003e\n\u003cli\u003e6000-count True-RMS display\u003c\/li\u003e\n\u003cli\u003eLow-impedance (LoZ) voltage mode\u003c\/li\u003e\n\u003cli\u003eVFD low-pass filter\u003c\/li\u003e\n\u003cli\u003e100 ms inrush-current measurement\u003c\/li\u003e\n\u003cli\u003eResistance to 60 MΩ\u003c\/li\u003e\n\u003cli\u003eCapacitance to 100 mF\u003c\/li\u003e\n\u003cli\u003eTemperature measurement to 1000°C\u003c\/li\u003e\n\u003cli\u003eREL \/ zero and peak functions\u003c\/li\u003e\n\u003cli\u003eNCV voltage detection\u003c\/li\u003e\n\u003cli\u003e48 mm jaw opening\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V \/ CAT III 1000 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e CEM DT-9381A\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 20px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eAC\/DC current\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eUp to 1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eAC\/DC voltage\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eUp to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e6000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eResistance\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eUp to 60 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eUp to 100 mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eTemperature\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eUp to 1000 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eFunctions\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eTrue RMS, frequency, inrush, LoZ, VFD filter, REL, NCV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eJaw opening\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e48 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eSafety rating\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eCAT IV 600 V \/ CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eDatasheet\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/DT-9381A-1.pdf?v=1789871374\" target=\"_blank\" rel=\"noopener\"\u003eView the CEM DT-9381A datasheet \/ technical document\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIndustrial electrical maintenance\u003c\/li\u003e\n\u003cli\u003eCurrent and load measurements without circuit interruption\u003c\/li\u003e\n\u003cli\u003eMotor, drive and distribution-panel troubleshooting\u003c\/li\u003e\n\u003cli\u003eSolar PV and high-voltage DC measurements where specified\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"CEM","offers":[{"title":"Default Title","offer_id":68073825698021,"sku":"CEM-DT-9381A","price":810.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/img_14.jpg?v=1794269877"},{"product_id":"professional-true-rms-digital-multimeter-cem-dt-9515","title":"Professional True-RMS Digital Multimeter – DT-9515","description":"\u003cp\u003eThe \u003cstrong\u003eCEM DT-9515\u003c\/strong\u003e is a professional manual-ranging 6000-count True-RMS digital multimeter for general electrical and electronics measurements.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue-RMS AC measurement\u003c\/li\u003e\n\u003cli\u003e6000-count LCD display\u003c\/li\u003e\n\u003cli\u003eManual range selection\u003c\/li\u003e\n\u003cli\u003eAC\/DC voltage measurement up to 1000 V\u003c\/li\u003e\n\u003cli\u003eAC\/DC current measurement up to 10 A\u003c\/li\u003e\n\u003cli\u003eResistance to 60 MΩ\u003c\/li\u003e\n\u003cli\u003eCapacitance to 6000 µF\u003c\/li\u003e\n\u003cli\u003eFrequency to 10 MHz\u003c\/li\u003e\n\u003cli\u003eContinuity and diode testing\u003c\/li\u003e\n\u003cli\u003eData Hold and Peak functions\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V \/ CAT III 1000 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e CEM DT-9515\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 20px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e6000 counts, manual ranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eAC\/DC voltage\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eUp to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eAC\/DC current\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eUp to 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eResistance\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eUp to 60 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eUp to 6000 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eFrequency\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eUp to 10 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eFunctions\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eTrue RMS, continuity, diode, data hold, peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eSafety rating\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eCAT IV 600 V \/ CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eElectrical and electronic troubleshooting\u003c\/li\u003e\n\u003cli\u003eIndustrial maintenance and commissioning\u003c\/li\u003e\n\u003cli\u003eSolar PV installation testing where specified\u003c\/li\u003e\n\u003cli\u003eWorkshop, field-service and laboratory measurements\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/ITS-CEM-DT-9515-Datasheet.pdf?v=1790205846\" target=\"_blank\" rel=\"noopener\"\u003eDT-9515 technical datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"CEM","offers":[{"title":"Default Title","offer_id":68073827008741,"sku":"CEM-DT-9515","price":140.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/cem-dt-9515_bb20dc6f-009e-4610-8912-e548828cb62e.jpg?v=1794269883"},{"product_id":"professional-lcr-meter-cem-dt-9935","title":"Professional LCR Meter – DT-9935","description":"\u003cp\u003eThe \u003cstrong\u003eCEM DT-9935\u003c\/strong\u003e is a dedicated professional LCR meter for precision component measurement, automatically identifying and measuring inductance, capacitance and resistance together with quality factor, dissipation factor and phase angle.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic L, C and R measurement selection\u003c\/li\u003e\n\u003cli\u003eInductance range: 20 µH to 2000 H\u003c\/li\u003e\n\u003cli\u003eCapacitance range: 20 pF to 20 mF\u003c\/li\u003e\n\u003cli\u003eResistance \/ DC resistance: 20 Ω to 2000 MΩ\u003c\/li\u003e\n\u003cli\u003eMeasures Q (quality factor), D (dissipation factor) and phase angle θ\u003c\/li\u003e\n\u003cli\u003eTest frequency up to 10 kHz\u003c\/li\u003e\n\u003cli\u003eOutput test frequency up to 100 kHz\u003c\/li\u003e\n\u003cli\u003eSupports high-accuracy four- or five-terminal Kelvin measurements\u003c\/li\u003e\n\u003cli\u003eAuto power-off and low-battery indication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e CEM DT-9935\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 20px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eInductance\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e20 µH to 2000 H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e20 pF to 20 mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eResistance \/ DC resistance\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e20 Ω to 2000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eAdditional parameters\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eQ, dissipation factor (D), phase angle (θ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eTest frequency\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eUp to 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eOutput test frequency\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eUp to 100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eMeasurement connection\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eKelvin measurement support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eDatasheet\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/CEM-DT-9935-datasheet_768d9ef7-a3fc-49ed-84f2-08203357eef6.pdf?v=1789871750\" target=\"_blank\" rel=\"noopener\"\u003eDownload the CEM DT-9935 datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eComponent inspection and incoming quality control\u003c\/li\u003e\n\u003cli\u003eCapacitor, inductor and resistor measurement\u003c\/li\u003e\n\u003cli\u003eElectronics repair and production testing\u003c\/li\u003e\n\u003cli\u003eLaboratory and educational measurement\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"CEM","offers":[{"title":"Default Title","offer_id":68073828221157,"sku":"CEM-DT-9935","price":360.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/cem-dt-9935-profesyonel-el-tipi-lcr-me-472-a5.jpg?v=1794269889"},{"product_id":"1500v-solar-pv-true-rms-multimeter-cem-dt-9561h","title":"1500 V Solar PV True-RMS Multimeter – DT-9561H","description":"\u003cp\u003eThe \u003cstrong\u003eCEM DT-9561H\u003c\/strong\u003e is a rugged True-RMS multimeter designed specifically for photovoltaic installation and maintenance, with high-voltage DC measurement for modern solar arrays.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePV DC voltage measurement up to 1500 V\u003c\/li\u003e\n\u003cli\u003eAC voltage measurement up to 1000 V\u003c\/li\u003e\n\u003cli\u003eAC\/DC current measurement\u003c\/li\u003e\n\u003cli\u003eTrue-RMS accuracy\u003c\/li\u003e\n\u003cli\u003eResistance, capacitance, frequency, temperature and duty-cycle functions\u003c\/li\u003e\n\u003cli\u003eLow-pass filter for inverter \/ VFD measurements\u003c\/li\u003e\n\u003cli\u003eMax\/Min and Peak Capture functions\u003c\/li\u003e\n\u003cli\u003eIP67 dust and water protection\u003c\/li\u003e\n\u003cli\u003e3 m drop protection\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V \/ CAT III 1000 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e CEM DT-9561H\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 20px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003ePV DC voltage\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eUp to 1500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eAC voltage\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eUp to 1000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eCurrent\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eAC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eFunctions\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eResistance, capacitance, frequency, temperature, duty cycle, continuity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eMeasurement modes\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eTrue RMS, LPF\/VFD, Max\/Min, Peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eIngress protection\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eDrop rating\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eSafety rating\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eCAT IV 600 V \/ CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eElectrical and electronic troubleshooting\u003c\/li\u003e\n\u003cli\u003eIndustrial maintenance and commissioning\u003c\/li\u003e\n\u003cli\u003eSolar PV installation testing where specified\u003c\/li\u003e\n\u003cli\u003eWorkshop, field-service and laboratory measurements\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDatasheet\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/CEM-DT-9561H-datasheet.pdf?v=1789871376\" target=\"_blank\" rel=\"noopener\"\u003eDownload the DT-9561H datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"CEM","offers":[{"title":"Default Title","offer_id":68073829335269,"sku":"CEM-DT-9561H","price":1130.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/01_nrsie2.jpg?v=1794269895"},{"product_id":"1500v-solar-pv-clamp-meter-cem-dt-9481","title":"1500 V Solar PV Clamp Meter – DT-9481","description":"\u003cp\u003eThe \u003cstrong\u003eCEM DT-9481\u003c\/strong\u003e is a rugged 1500 V solar PV clamp meter for safe current, voltage and electrical measurements during PV installation and maintenance.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePV voltage measurement up to 1500 V class\u003c\/li\u003e\n\u003cli\u003eAC\/DC clamp-current measurement up to 1000 A class\u003c\/li\u003e\n\u003cli\u003eTrue-RMS measurement\u003c\/li\u003e\n\u003cli\u003eLow-pass filter for inverter \/ VFD signals\u003c\/li\u003e\n\u003cli\u003eInrush-current measurement\u003c\/li\u003e\n\u003cli\u003eResistance, capacitance, frequency, temperature and duty-cycle functions\u003c\/li\u003e\n\u003cli\u003eOptional flexible current probe extends AC-current capability to 3000 A\u003c\/li\u003e\n\u003cli\u003eWireless PC \/ smartphone connectivity\u003c\/li\u003e\n\u003cli\u003eData logging and reporting support\u003c\/li\u003e\n\u003cli\u003eIP67 protection and 3 m drop rating\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V \/ CAT III 1000 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e CEM DT-9481\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 20px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003ePV voltage\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eUp to 1500 V class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eAC\/DC current\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eUp to 1000 A class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eMeasurement\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eTrue RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eFunctions\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eLPF\/VFD, inrush, resistance, capacitance, frequency, temperature, duty cycle, continuity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eData logging\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eWireless PC\/App\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eOptional flexible clamp\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eUp to 3000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eIngress protection\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eDrop rating\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eSafety rating\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eCAT IV 600 V \/ CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIndustrial electrical maintenance\u003c\/li\u003e\n\u003cli\u003eCurrent and load measurements without circuit interruption\u003c\/li\u003e\n\u003cli\u003eMotor, drive and distribution-panel troubleshooting\u003c\/li\u003e\n\u003cli\u003eSolar PV and high-voltage DC measurements where specified\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDatasheet\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/CEM-DT-9481-datasheet.PDF?v=1789871377\" target=\"_blank\" rel=\"noopener\"\u003eDownload the DT-9481 datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"CEM","offers":[{"title":"Default Title","offer_id":68073830088933,"sku":"CEM-DT-9481","price":1390.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/cem-dt-9481_ec909767-e09c-4070-b4ac-9144af44081c.jpg?v=1794269900"}],"url":"https:\/\/inspectec.co.nz\/collections\/electrical-and-electronic-testing.oembed","provider":"Inspectec","version":"1.0","type":"link"}