{"title":"Flow Measurement","description":"","products":[{"product_id":"portable-flow-meter","title":"Portable Flow Meter FM-210V5","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003cbr\u003eThe FM-210V5 Portable Flow Meter is a versatile, high-precision instrument ideal for use in various settings such as hydrological stations, industrial plants, environmental monitoring stations, farmland irrigation, drainage systems, and hydrogeological surveys. It accurately measures flow velocity in open channels, even in challenging environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for testing in sewage environments\u003c\/li\u003e\n\u003cli\u003eSimple, lightweight, and portable structure\u003c\/li\u003e\n\u003cli\u003eLow power consumption with comprehensive functionality\u003c\/li\u003e\n\u003cli\u003eHigh automation level; stable and reliable performance\u003c\/li\u003e\n\u003cli\u003eComplies with national standards for high-temperature rotary slurry\u003c\/li\u003e\n\u003cli\u003eInnovative design for efficient flow velocity measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003e\u003cstrong\u003eProduct Specifications\u003c\/strong\u003e\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eK: 0.0500, C: 0.0100\u003c\/li\u003e\n\u003cli\u003eMeasurement formula: V = ------- + C (m\/s) (automatic calculation)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpeed Range\u003c\/strong\u003e: 0.01 - 5.00 m\/s (FM-210V5)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Error\u003c\/strong\u003e: ≤ 1.5%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range\u003c\/strong\u003e: -10°C to 50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay\u003c\/strong\u003e: LCD liquid crystal display with LED backlight\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Method\u003c\/strong\u003e: Pole positioning measurement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHost Dimensions\u003c\/strong\u003e: 70mm x 140mm x 30mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply\u003c\/strong\u003e: Requires 4 x 7 batteries or external power supply (5V)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003eDownloads\u003c\/h6\u003e\n\u003cp\u003ePDF Specification Sheet - \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/Portable_flow_meter_FM-210V5_CA_.EN_compressed.pdf?v=1711770763\" rel=\"noopener\" target=\"_blank\"\u003eDownload Here\u003c\/a\u003e\u003c\/p\u003e","brand":"Tomlin Tools","offers":[{"title":"Default Title","offer_id":48426989256933,"sku":"FM-210V5","price":900.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/DSC08362.jpg?v=1771402900"},{"product_id":"pressure-gauge-pce-dpg-10","title":"Digital Manometer PCE-DPG","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eManometer PCE-DPG 3-ICA incl. ISO Calibration Certificate\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePressure sensor for water and gases \/ 1\/4\" NPT threaded connection \/ Adjustable backlight \/ PEAK function \/ Battery status indicator \/ Battery-operated\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv\u003eThe manometer of the PCE-DPG series is well suited for monitoring and displaying air pressure and water pressure. Thanks to its high measuring resolution and high accuracy, this manometer is versatile. The current pressure is displayed by the manometer as a value and at the same time as a bar graph. As an additional function, the manometer offers a peak function. This function shows the operator the maximum and minimum pressure measured on the manometer at the push of a button.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eThanks to the large display of 2.5\" almost all measured values ​​can be read directly. Possible adjustable units for the manometer would be Mpa, bar, Kpa, mH2o, kg \/ cm2, psi, mmH2o, in.WC and mbar. The response time of the manometer is \u0026lt; 50 ms. The connection of the manometer to the process is realized via a 1\/4\" NPT connection. Typical applications include suction control, leak testing or pressure monitoring.\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Measuring range up to 3\/ 6\/ 10\/ 100\/ 200 Bar (Depending on model)\u003cbr\u003e- Scaled bar graph\u003cbr\u003e- Battery powered 3 x 1.5V AAA\u003cbr\u003e- Large 2.5\" display\u003cbr\u003e- Adjustable backlight\u003cbr\u003e- 1.4\" NPT connection thread\u003cbr\u003e- incl. ISO Calibration Certificate\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e3\/ 6\/ 10\/ 100\/ 200 Bar (Depending on model)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.0145 psi, 0.001 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.25% FSO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure\u003c\/td\u003e\n\u003ctd\u003erelative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverpressure\u003c\/td\u003e\n\u003ctd\u003e1.5 times\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurable media\u003c\/td\u003e\n\u003ctd\u003egases, water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing material\u003c\/td\u003e\n\u003ctd\u003emetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement units\u003c\/td\u003e\n\u003ctd\u003eMpa, bar, Kpa, mH2o, kg \/ cm²,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003epsi, mmH2o, in.WC, mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIP56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiameter display\u003c\/td\u003e\n\u003ctd\u003e2.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (without sensor)   \u003c\/td\u003e\n\u003ctd\u003eØ80 x 50 mm \/ 3.1 x 2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure connection\u003c\/td\u003e\n\u003ctd\u003e1\/40\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e3 x 1.5V AAA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental conditions\u003c\/td\u003e\n\u003ctd\u003e-10 ... 60°C \/ 14 ... 140°F, \u0026lt; 80% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eapprox. 276 g \/ \u0026lt; 1 lb (without batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cp\u003e1 x Manometer PCE-DPG 3\/ 6\/ 10\/ 100\/ 200 Bar (Depending on model)\u003cbr\u003e3 x Batteries 1.5V AAA\u003cbr\u003e1 x Operating instructions\u003cbr\u003e1 x ISO Calibration Certificate (Optional)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding \/ PCE-DPG 3 Bar (43.5psi)","offer_id":48427056955621,"sku":"PCE-DPG 10","price":1110.0,"currency_code":"NZD","in_stock":true},{"title":"Excluding \/ PCE-DPG 6 Bar (87psi)","offer_id":48427056988389,"sku":null,"price":1110.0,"currency_code":"NZD","in_stock":true},{"title":"Excluding \/ PCE-DPG 10 Bar (145psi)","offer_id":48427057021157,"sku":null,"price":1110.0,"currency_code":"NZD","in_stock":true},{"title":"Excluding \/ PCE-DPG 100 Bar (1450psi)","offer_id":48427057053925,"sku":null,"price":1110.0,"currency_code":"NZD","in_stock":true},{"title":"Excluding \/ PCE-DPG 200 Bar (2900psi)","offer_id":48427057086693,"sku":null,"price":1110.0,"currency_code":"NZD","in_stock":true},{"title":"Including \/ PCE-DPG 3 Bar (43.5psi)","offer_id":48427057119461,"sku":null,"price":1730.0,"currency_code":"NZD","in_stock":true},{"title":"Including \/ PCE-DPG 6 Bar (87psi)","offer_id":48427057152229,"sku":null,"price":1730.0,"currency_code":"NZD","in_stock":true},{"title":"Including \/ PCE-DPG 10 Bar (145psi)","offer_id":48427057184997,"sku":null,"price":1730.0,"currency_code":"NZD","in_stock":true},{"title":"Including \/ PCE-DPG 100 Bar (1450psi)","offer_id":48427057217765,"sku":null,"price":1730.0,"currency_code":"NZD","in_stock":true},{"title":"Including \/ PCE-DPG 200 Bar (2900psi)","offer_id":48427057250533,"sku":null,"price":1730.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-pressure-gauge-pce-dpg-100-ica-incl.-iso-calibration-certificate-5953538_2730201_1.webp?v=1771404832"},{"product_id":"differential-pressure-gauge-pce-917","title":"Air \u0026 Gas Pressure Gauge PCE-917","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cp align=\"center\"\u003e\u003cstrong\u003ePCE-917 Differential Pressure Gauge incl. ISO calibration certificate\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePortable handheld manometer measures differential pressure from ± 5 to 7000 mbar (± 0.05 \/ 0.1 to 101.5 psi) \/ Optional PC software with RS-232 cable sold separately as a data transfer accessory\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003ePCE-917 is a portable handheld digital differential pressure gauge, meter or manometer used to measure differential pressure in pneumatic, compressor and pump installations, valves, tanks and heating, ventilation and air conditioning (HVAC) systems. The PCE-917 features a dust-proof, splash-resistant housing, allowing the meter to be used under adverse conditions.\u003c\/p\u003e\n\u003cp\u003eThe PCE-917 differential pressure manometer comes with 1 x 1 m \/ 3 ft long silicon tube, 2 x stainless steel tube adapters and 1 x 9V block battery. Optional PC software with RS-232 cable sold separately as a data transfer accessory. The software can be used to transmit the data to a computer for evaluating, documenting and storing pressure fluctuations. Simply connect the differential manometer via RS-232 to your computer for analysis. If your computer doesn't have an RS-232 interface, you may acquire an RS-232 to USB adapter (see accessories tab for details).\u003c\/p\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- ± 5 to 7000 mbar (± 0.05 \/ 0.1 to 101.5 psi) measuring range\u003cbr\u003e- 10 measurement units: psi, mbar, inH2O, mH2O, inHg, mmHg, Torr, Pa \/ kPa, atm, kg\/cm²\u003cbr\u003e- Designed to measure air, gas and non-corrosive liquid pressures\u003cbr\u003e- Min, max and data hold functions\u003cbr\u003e- RS-232 port \/ interface\u003cbr\u003e- 15 mm \/ 0.6 in LCD screen\u003cbr\u003e- Optional PC software with RS-232 cable sold separately as a data transfer accessory\u003cbr\u003e-\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eIncl. ISO calibration certificate\u003c\/strong\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable border=\"0\" bgcolor=\"#FFFFFF\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003embar\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eResolution: 5\u003cbr\u003eRange: ± 7000\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003epsi\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eResolution: 0.05 \/ 0.1\u003cbr\u003eRange: ± 101.5\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003einH2O\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eResolution: 2\u003cbr\u003eRange: ± 2800\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003emH2O\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eResolution: 0.05\u003cbr\u003eRange: ± 70.00\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003einHg\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eResolution: 0.1\u003cbr\u003eRange: ± 206.0\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003emmHg\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eResolution: 5\u003cbr\u003eRange: ± 5250\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eTorr\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eResolution: -\u003cbr\u003eRange: -\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePa \/ kPa\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eResolution: -\u003cbr\u003eRange: -\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eatm\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eResolution: 0.005\u003cbr\u003eRange: ± 6.905\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ekg\/cm²\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eResolution: 0.005\u003cbr\u003eRange: ± 7.000\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e± 2% (full range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eReproducibility\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e± 1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResponse time\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.8 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eInterface\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eRS-232 port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePower supply\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 x 9V block battery\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eHousing material\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003ePlastic\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eHousing dimensions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eApprox. 180 x 72 x 32 mm \/ 7.09 x 2.84 x 1.26 in\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eApprox. 210 g \/ \u0026lt; 1 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eWarning:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e***Exceeding the maximum pressure range will destroy the sensor***\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e1 x PCE-917 differential pressure gauge\u003cbr\u003e1 x 9V block battery\u003cbr\u003e2 x Stainless steel tube adapters\u003cbr\u003e1 x 1 m \/ 3 ft long silicon tube\u003cbr\u003e1 x User manual\u003c\/div\u003e\n\u003cstrong\u003e1 x ISO calibration certificate\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding ISO Calibration","offer_id":48427057512677,"sku":"PCE-917","price":970.0,"currency_code":"NZD","in_stock":true},{"title":"Including ISO Calibration","offer_id":48427057545445,"sku":"PCE-917-ICA","price":1590.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-differential-pressure-gauge-pce-917-ica-incl.-iso-calibration-certificate-5886058_1235526_1.webp?v=1771404848"},{"product_id":"differential-pressure-meter-pressure-gauge-pce-p01","title":"Digital Differential Pressure Meter PCE-P01","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eDifferential Pressure\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003eGauge PCE-P01-ICA incl. ISO Calibration Certificate\u003cbr\u003eDifferential manometer for the measuring range from -140 to +140 mbar, including software\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\nThe differential pressure gauge PCE-P01 is a robust, compact and comprehensive differential pressure gauge for measuring pressure in 11 adjustable units. The PCE-P01 is particularly suitable for the complete documentation of your measuring tasks. The minimum, maximum and average values of your measurement can be viewed in parallel to the current measured value on the large display of the PCE-P01 differential meter. For example, if you want to determine and document pressure fluctuations, you can use the enclosed software, with the help of which it is possible, for example, to transfer the measured values to the computer every second and display them graphically and in tabular form.\u003cbr\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Easiest operation\u003cbr\u003e- Measurement of differential pressure and static pressure in 11 selectable units: mbar, bar, psi, kPa, ...\u003cbr\u003e- Measuring range from -140 to +140 mbar\u003cbr\u003e- Min \/ max and average value display\u003cbr\u003e- \"Hold\" function\u003cbr\u003e- Backlight can be switched on \/ off\u003cbr\u003e- For long-term measurements including power supply\u003cbr\u003e- Software with USB cable included\u003cbr\u003e- Battery level indicator\u003cbr\u003e- Auto-off function that can be switched off\u003cbr\u003e- Zero point adjustment possible at any time\u003cbr\u003e-\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eincl. ISO Calibration Certificate\u003c\/strong\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003e\u003cstrong\u003eMeasuring range \u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e (\u003c\/span\u003e\u003cspan\u003e±)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003einH2O \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003epsi \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003embar \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ekPa \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003einHg \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003emmHg \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eozin² \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eftH2O \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ecmH2O \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ekgcm² \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ebar\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e55.40 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e2.000 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e137.8 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e13.79 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e4.072 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e103.4 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e32.00 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e4.612 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e140.6 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.140 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.137\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003e\u003cstrong\u003eResolution  \u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003einH2O \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003epsi \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003embar \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ekPa \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003einHg \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003emmHg \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eozin² \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eftH2O \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ecmH2O \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ekgcm² \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ebar\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e0.01 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.001 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.1 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.01 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.001 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.1 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.01 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.001 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.1 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.001 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.001\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy (at +25 °C \/ +77 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e± 0.3%\u003c\/span\u003e\u003cspan\u003e of measuring range\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinearity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e± 0.2%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResponse time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 0.5 sec.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax. pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e689 mbar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 ... 50°C \/ 32 ... 122°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 ... 60°C \/ 14 ... 140°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMedia\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAir and non-explosive gases\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eReal-time data-logging interval    \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 sec. to 24 h adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual LCD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e210 x 75 x 50 mm \/ 8.27 x 2.95 x 1.97 in (H x W x D)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight (without batteries)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e650 g \/ 1.44 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eBattery: 1 x 9V block \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eAC adapter: 9V DC \/ 500-mA \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cp\u003e1 x Pressure Gauge PCE-P01\u003cbr\u003e4 x 30cm \/ 11.8\" silicone hose\u003cbr\u003e1 x Software including USB cable\u003cbr\u003e1 x 9V block battery\u003cbr\u003e1 x 9V DC power supply\u003cbr\u003e1 x Plastic case\u003cbr\u003e1 x User manual\u003cbr\u003e1 x ISO Calibration Certificate\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding ISO Calibration","offer_id":48427057610981,"sku":"PCE-P01","price":630.0,"currency_code":"NZD","in_stock":true},{"title":"Including ISO Calibration","offer_id":48427057643749,"sku":"PCE-P01-ICA","price":1160.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-pressure-gauge-pce-p01-ica-incl.-iso-calibration-certificate-5953752_1585827.webp?v=1771404862"},{"product_id":"differential-pressure-meter-pressure-gauge-pce-p05","title":"Digital Differential Pressure Meter PCE-P05","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cp align=\"center\"\u003e\u003cstrong\u003ePCE-P05 Differential Pressure Meter incl. ISO calibration certificate\u003cbr\u003ePortable handheld manometer measures differential pressure from \u003c\/strong\u003e\u003cspan\u003e-\u003c\/span\u003e\u003cspan\u003e0.344 to 0.344 bar (-5.000 to 5.000 psi)\u003c\/span\u003e\u003cstrong\u003e \/ Features real-time data-logging capabilities using the included PC software and USB cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003ePCE-P05 is a portable handheld digital differential pressure meter or manometer used to measure differential pressure in pneumatic, compressor and pump installations, valves, tanks and heating, ventilation and air conditioning (HVAC) systems. The PCE-P05 displays min \/ max \/ average values right on the meter's screen for comparison against current measurement values.\u003c\/p\u003e\n\u003cp\u003eIn addition, the PCE-P05 differential pressure manometer features real-time data-logging capabilities with an adjustable interval from 1 second to 24 hours. The device comes with 4 x 30 cm \/ 11.81 in silicon tubes, 1 x 9V block battery and 1 x AC power adapter. Also included in the delivery contents are PC-compatible software and a USB cable. The software can be used to detect and document pressure fluctuations, and to display the data graphically or in a table. For real-time data recording, simply connect the differential manometer via USB to your computer, and save the measured values ​​according to your selected time interval. You can then calculate average values ​​directly in the software or export the saved data to Microsoft Excel.\u003c\/p\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Easiest operation\u003cbr\u003e- 11 selectable units: mbar, bar, psi, kPa, ...\u003cbr\u003e- Measuring range from -344 ... +344 mbar \/ -5.000 to +5.000 psi\u003cbr\u003e- Min \/ max and average value display\u003cbr\u003e- \"Hold\" function\u003cbr\u003e- Backlight can be switched on \/ off\u003cbr\u003e- For long-term measurements including power supply\u003cbr\u003e- Software with USB cable included\u003cbr\u003e- Battery level indicator\u003cbr\u003e- Auto-off function that can be switched off\u003cbr\u003e- Zero point adjustment possible at any time\u003cbr\u003e-\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eincl. ISO Calibration Certificate\u003c\/strong\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003e\u003cstrong\u003eMeasuring range\u003c\/strong\u003e \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003einH2O \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003epsi \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003embar \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ekPa \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003einHg \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003emmHg \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eozin² \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eftH2O \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ecmH2O \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ekgcm² \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ebar\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e (±)\u003cbr\u003e138.30 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e5.000 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e344.7 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e34.47 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1.018 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e258.5 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e80.00 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e11.53 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e351.5 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.351 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.344\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003eResolution  \u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003einH2O \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003epsi \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003embar \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ekPa \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003einHg \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003emmHg \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eozin² \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eftH2O \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ecmH2O \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ekgcm² \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ebar\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e\u003cbr\u003e\u003cbr\u003e0.1 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.001 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.1 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.01 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.001 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.1 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.01 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.001 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.1 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.001 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.001\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy (at +25 °C \/ +77 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e± 0.3%\u003c\/span\u003e\u003cspan\u003e of measuring range\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinearity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e± 0.2%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResponse time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 0.5 sec.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax. pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1378 mbar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 ... 50°C \/ 32 ... 122°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 ... 60°C \/ 14 ... 140°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMedia\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAir and non-explosive gases\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eReal-time data-logging interval    \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 sec. to 24 h adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual LCD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e210 x 75 x 50 mm \/ 8.27 x 2.95 x 1.97 in (H x W x D)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight (without batteries)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e650 g \/ 1.44 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eBattery: 1 x 9V block \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eAC adapter: 9V DC \/ 500-mA \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\u003cbr\u003eSee user manual for complete technical specifications.\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cp\u003e1 x Differential Pressure Meter PCE-P05\u003cbr\u003e4 x 30cm \/ 11.8\" silicone hose\u003cbr\u003e1 x Software including USB cable\u003cbr\u003e1 x 9V block battery\u003cbr\u003e1 x 9V DC power supply\u003cbr\u003e1 x Plastic case\u003cbr\u003e1 x User manual\u003cbr\u003e1 x ISO Calibration Certificate\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding ISO Calibration","offer_id":48427057709285,"sku":"PCE-P05","price":700.0,"currency_code":"NZD","in_stock":true},{"title":"Including ISO Calibration","offer_id":48427057742053,"sku":"PCE-P05-ICA","price":1210.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-pressure-gauge-pce-p01-ica-incl.-iso-calibration-certificate-5953752_1585827_6512263a-5f90-4443-b99d-4befc20d537a.webp?v=1771404874"},{"product_id":"differential-pressure-meter-pressure-gauge-pce-p30","title":"Digital Differential Pressure Meter PCE-P30","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\u003cstrong\u003eHVAC Meter PCE-P30-ICA with RS232 interface and software, for overpressure, underpressure, differential pressure, suitable for air and gases \/ incl. ISO calibration certificate\u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003eHere you can see a professional differential pressure HVAC meter with the highest accuracy and best performance. With this differential manometer you can not only measure. The pressure readings can easily be transferred online to a PC or laptop. The differential pressure gauge is ideal for use in industry, in service and in the laboratory. The device is particularly suitable for measuring non-corrosive media. The overload protection is twice the measuring range. The 9 units that can be shown on the display make this differential manometer universally applicable for the practitioner on site and saves laborious conversion of the measurement results (conversion table of the pressure units).\u003cbr\u003e \u003cbr\u003eIf you want to transfer the measurement data from the differential manometer to the computer, you need the optional software and the RS-232 interface cable. The software runs in conjunction with the Windows® versions `95,` 98, `2000 and ME \/ XP (short info: pressure measuring device with interface). The principle of absolute and differential pressure measurement is explained if you follow the link below: Principle of absolute and differential pressure measurement. DIN ISO 9000 calibration certificates for the pressure gauges and corresponding accessories are also available.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThe software for data transfer and the interface cable can optionally be ordered as a package. The differential manometer is connected to the PC with the RS-232 cable. The software is installed from the CD. The pictures below give you an optical impression of the software. The differential manometer transmits the respective measured values ​​online to the PC.\u003cbr\u003e\u003cbr\u003eThe values ​​determined on the differential manometer are plotted directly on the y-axis. The differential pressure values ​​are indicated with \"-\" in a field below the graphic (visible on the top left picture (in the red circle)). The measuring units can be changed to the desired unit both on the differential manometer and in the software. All measured values ​​are written in a data file and can be saved under any name on the hard disk of the computer. Many customers also transfer the values ​​to e.g. MS Excel for further analysis.\u003cbr\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- 9 selectable units\u003cbr\u003e- Digital display of over, under (vacuum) or differential pressure\u003cbr\u003e- Min \/ Max memory\u003cbr\u003e- Data hold function\u003cbr\u003e- Backlit LCD display\u003cbr\u003e- Impact-resistant ABS housing\u003cbr\u003e- Auto-power-off function\u003cbr\u003e-\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIncl. ISO calibration certificate\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFurther areas of application\u003c\/strong\u003e\u003cbr\u003eThe applications of the differential manometer are diverse.\u003cbr\u003eFor example, it is used in:\u003cbr\u003e\u003cbr\u003e- Pneumatic area, on compressors and pumping systems\u003cbr\u003e- Chemical area for process control, measurements on pressure tanks\u003cbr\u003e- Manufacturing area, for compressed air press processes e.g. in the plastics industry\u003cbr\u003e- Checking valve controls (before- after- loss of compressed air)\u003cbr\u003e- Research and development area\u003cbr\u003e- In general for optimization and testing in the process\u003cbr\u003e- Authorization area for heating and air conditioning systems\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Meter \u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003ePCE-P30\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Pressure\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003epositive\/ negative\u003cbr\u003eor overpressure \/ vacuum \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e60 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePSI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003embar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003einH\u003c\/strong\u003e\u003csub\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/sub\u003e\u003cstrong\u003e0\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±830\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003einHg\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emmHg\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ekPa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003ecmH\u003c\/strong\u003e\u003csub\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/sub\u003e\u003cstrong\u003e0\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±2100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKg\/cm²\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±2.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eData format\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eBaud rate: 2400 baud,1 stop bit, 8 data bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.3 % (full range, @ +25°C \/ +77°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.2 % (max. ±0.5 % of full scale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eDuration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.3 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eOperating temperature max\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+50 °C \/ +122 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eBattery\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 x 9 V - block battery PP3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eDimensions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e182 x 72 x 30 mm \/ 7.1 x 2.8 x 1.1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e150 g \/ 5.3 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x HVAC Meter PCE-P30-ICA Differential Pressure\u003cbr\u003e1 x Carrying case\u003cbr\u003e1 x Battery\u003cbr\u003e1 x PVC hose (1 m \/ 39\")\u003cbr\u003e1 x Instruction manual\u003cbr\u003e1 x Protective cover\u003cbr\u003e1 x\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eISO calibration certificate\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eWarning\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eOverloading destroys the sensor in the PCE-P30 pressure measuring device\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding ISO Calibration","offer_id":48427057807589,"sku":"PCE-P30","price":870.0,"currency_code":"NZD","in_stock":true},{"title":"Including ISO Calibration","offer_id":48427057840357,"sku":"PCE-P30-ICA","price":1370.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-hvac-meter-pce-p30-differential-pressure-incl.-iso-calibration-certificate-5886124_1235932_55d5cc9f-6e4f-45aa-b79f-430f388f3110.webp?v=1771404885"},{"product_id":"differential-pressure-meter-pressure-gauge-pce-p50","title":"Digital Differential Pressure Meter PCE-P50","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\u003cstrong\u003eDifferential Pressure Meter PCE-P50-ICA with RS232 interface and software, for overpressure, underpressure, differential pressure, suitable for air and gases \/ incl. ISO calibration certificate\u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003eHere you can see a professional differential pressure meter with the highest accuracy and best performance. With this differential manometer you can not only measure. The pressure readings can easily be transferred online to a PC or laptop. The differential pressure gauge is ideal for use in industry, in service and in the laboratory. The device is particularly suitable for measuring non-corrosive media. The overload protection is twice the measuring range. The 9 units that can be shown on the display make this differential manometer universally applicable for the practitioner on site and saves laborious conversion of the measurement results (conversion table of the pressure units).\u003cbr\u003e \u003cbr\u003eIf you want to transfer the measurement data from the differential manometer to the computer, you need the optional software and the RS-232 interface cable. The software runs in conjunction with the Windows® versions `95,` 98, `2000 and ME \/ XP (short info: pressure measuring device with interface). The principle of absolute and differential pressure measurement is explained if you follow the link below: Principle of absolute and differential pressure measurement. DIN ISO 9000 calibration certificates for the pressure gauges and corresponding accessories are also available.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThe software for data transfer and the interface cable can optionally be ordered as a package. The differential manometer is connected to the PC with the RS-232 cable. The software is installed from the CD. The pictures below give you an optical impression of the software. The differential manometer transmits the respective measured values ​​online to the PC.\u003cbr\u003e\u003cbr\u003eThe values ​​determined on the differential manometer are plotted directly on the y-axis. The differential pressure values ​​are indicated with \"-\" in a field below the graphic (visible on the top left picture (in the red circle)). The measuring units can be changed to the desired unit both on the differential manometer and in the software. All measured values ​​are written in a data file and can be saved under any name on the hard disk of the computer. Many customers also transfer the values ​​to e.g. MS Excel for further analysis.\u003cbr\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- 9 selectable units\u003cbr\u003e- Digital display of over, under (vacuum) or differential pressure\u003cbr\u003e- Min \/ Max memory\u003cbr\u003e- Data hold function\u003cbr\u003e- Backlit LCD display\u003cbr\u003e- Impact-resistant ABS housing\u003cbr\u003e- Auto-power-off function\u003cbr\u003e-\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIncl. ISO calibration certificate\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFurther areas of application\u003c\/strong\u003e\u003cbr\u003eThe applications of the differential manometer are diverse.\u003cbr\u003eFor example, it is used in:\u003cbr\u003e\u003cbr\u003e- Pneumatic area, on compressors and pumping systems\u003cbr\u003e- Chemical area for process control, measurements on pressure tanks\u003cbr\u003e- Manufacturing area, for compressed air press processes e.g. in the plastics industry\u003cbr\u003e- Checking valve controls (before- after- loss of compressed air)\u003cbr\u003e- Research and development area\u003cbr\u003e- In general for optimization and testing in the process\u003cbr\u003e- Authorization area for heating and air conditioning systems\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Meter \u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003ePCE-P50\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Pressure\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003epositive\/ negative\u003cbr\u003eor overpressure \/ vacuum \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e150 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePSI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003embar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±6900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003einH\u003c\/strong\u003e\u003csub\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/sub\u003e\u003cstrong\u003e0\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±2750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003einHg\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emmHg\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±5200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ekPa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±690\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003ecmH\u003c\/strong\u003e\u003csub\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/sub\u003e\u003cstrong\u003e0\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±7000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKg\/cm²\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eData format\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eBaud rate: 2400 baud,1 stop bit, 8 data bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.3 % (full range, @ +25°C \/ +77°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.2 % (max. ±0.5 % of full scale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eDuration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.3 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eOperating temperature max\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+50 °C \/ +122 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003ePower supply\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003e9 V DC \/ power converter (optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003e1 x 9 V - block battery PP3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eDimensions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e182 x 72 x 30 mm \/ 7.1 x 2.8 x 1.1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e150 g \/ 5.3 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Differential Pressure Meter PCE-P50-ICA\u003cbr\u003e1 x Carrying case\u003cbr\u003e1 x Battery\u003cbr\u003e1 x PVC hose (1 m \/ 39\")\u003cbr\u003e1 x Instruction manual\u003cbr\u003e1 x\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eISO calibration certificate\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding ISO Calibration","offer_id":48427057905893,"sku":"PCE-P50","price":970.0,"currency_code":"NZD","in_stock":true},{"title":"Including ISO Calibration","offer_id":48427057938661,"sku":"PCE-P50-ICA","price":1480.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-hvac-meter-pce-p30-differential-pressure-incl.-iso-calibration-certificate-5886124_1235932_9d3c6f67-a572-43e3-88b7-04feda0ac8fd.webp?v=1771404898"},{"product_id":"differential-pressure-meter-pressure-gauge-pce-p15","title":"Digital Differential Pressure Meter PCE-P15","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\u003cstrong\u003eDifferential Pressure Meter PCE-P15-ICA with RS232 interface and software, for overpressure, underpressure, differential pressure, suitable for air and gases, incl. ISO calibration certificate\u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003eHere you can see a professional differential pressure meter with the highest accuracy and best performance. With this differential manometer you can not only measure. The pressure readings can easily be transferred online to a PC or laptop. The differential pressure gauge is ideal for use in industry, in service and in the laboratory. The device is particularly suitable for measuring non-corrosive media. The overload protection is twice the measuring range. The 9 units that can be shown on the display make this differential manometer universally applicable for the practitioner on site and saves laborious conversion of the measurement results (conversion table of the pressure units).\u003cbr\u003e \u003cbr\u003eIf you want to transfer the measurement data from the differential manometer to the computer, you need the optional software and the RS-232 interface cable. The software runs in conjunction with the Windows® versions `95,` 98, `2000 and ME \/ XP (short info: pressure measuring device with interface). The principle of absolute and differential pressure measurement is explained if you follow the link below: Principle of absolute and differential pressure measurement. DIN ISO 9000 calibration certificates for the pressure gauges and corresponding accessories are also available.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThe software for data transfer and the interface cable can optionally be ordered as a package. The differential manometer is connected to the PC with the RS-232 cable. The software is installed from the CD. The pictures below give you an optical impression of the software. The differential manometer transmits the respective measured values ​​online to the PC.\u003cbr\u003e\u003cbr\u003eThe values ​​determined on the differential manometer are plotted directly on the y-axis. The differential pressure values ​​are indicated with \"-\" in a field below the graphic (visible on the top left picture (in the red circle)). The measuring units can be changed to the desired unit both on the differential manometer and in the software. All measured values ​​are written in a data file and can be saved under any name on the hard disk of the computer. Many customers also transfer the values ​​to e.g. MS Excel for further analysis.\u003cbr\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- 9 selectable units\u003cbr\u003e- Digital display of over, under (vacuum) or differential pressure\u003cbr\u003e- Min \/ Max memory\u003cbr\u003e- Data hold function\u003cbr\u003e- Backlit LCD display\u003cbr\u003e- Impact-resistant ABS housing\u003cbr\u003e- Auto-power-off function\u003cbr\u003e-\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eIncl. ISO calibration certificate\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFurther areas of application\u003c\/strong\u003e\u003cbr\u003eThe applications of the differential manometer are diverse.\u003cbr\u003eFor example, it is used in:\u003cbr\u003e\u003cbr\u003e- Pneumatic area, on compressors and pumping systems\u003cbr\u003e- Chemical area for process control, measurements on pressure tanks\u003cbr\u003e- Manufacturing area, for compressed air press processes e.g. in the plastics industry\u003cbr\u003e- Checking valve controls (before- after- loss of compressed air)\u003cbr\u003e- Research and development area\u003cbr\u003e- In general for optimization and testing in the process\u003cbr\u003e- Authorization area for heating and air conditioning systems\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Meter \u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003ePCE-P15\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Pressure\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003epositive\/ negative\u003cbr\u003eor overpressure \/ vacuum \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e30 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePSI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003embar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003einH\u003c\/strong\u003e\u003csub\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/sub\u003e\u003cstrong\u003e0\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±415\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003einHg\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±30.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emmHg\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ekPa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003ecmH\u003c\/strong\u003e\u003csub\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/sub\u003e\u003cstrong\u003e0\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±1050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKg\/cm²\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±1.05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eData format\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eBaud rate: 2400 baud,1 stop bit, 8 data bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.3 % (full range, @ +25°C \/ +77°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.2 % (max. ±0.5 % of full scale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eDuration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.3 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eOperating temperature max\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+50 °C \/ +122 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eBattery\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 x 9 V - block battery PP3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eDimensions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e182 x 72 x 30 mm \/ 7.1 x 2.8 x 1.1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e150 g \/ 5.3 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Differential Pressure Meter PCE-P15-ICA\u003cbr\u003e1 x Carrying case\u003cbr\u003e1 x Battery\u003cbr\u003e1 x PVC hose (1 m \/ 39\")\u003cbr\u003e1 x Instruction manual\u003cbr\u003e1 x Protective cover\u003cbr\u003e1 x\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eISO calibration certificate\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding ISO Calibration","offer_id":48427058069733,"sku":"PCE-P15","price":870.0,"currency_code":"NZD","in_stock":true},{"title":"Including ISO Calibration","offer_id":48427058102501,"sku":"PCE-P15-ICA","price":1370.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-hvac-meter-pce-p30-differential-pressure-incl.-iso-calibration-certificate-5886124_1235932.webp?v=1771404913"},{"product_id":"ultrasonic-flow-meter-pce-ufm-26","title":"Ultrasonic Flow Meter PCE-UFM Series","description":"\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch2 class=\"headline\"\u003eDescription\u003c\/h2\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003cstrong\u003eUltrasonic Flow Meter\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e \/ Measurement of Flow and Volume Flow via Ultrasonic \/ Compatible with Various Pipe Materials and Fluids \/ Analog Output 4 ... 20mA \/ RS485 Interface\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cbr\u003eOur ultrasonic flow meter offers the capability to measure flow rates from ±0.1 m\/s to ±5 m\/s using ultrasonic technology. This flow meter is suitable for small pipes with a diameter of DN4 \/ 1\/8\", DN8 \/ 1\/4\", DN10 \/ 3\/8\", DN15 \/ 1\/2\", DN20 \/ 3\/4\", DN25 \/ 1\" and is compatible with various pipe materials such as steel, copper, aluminum, and plastics. Due to its compact design, it can be quickly and easily mounted on the pipe.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eThe flow meter's display provides information on flow velocity, date, and time. In another view, it also displays the volume flow rate for the day, month, and year. Additionally, the flow meter can output the measurement value as an analog signal (4 ... 20mA) and digitally via an RS485 interface.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eWith a power supply range of 9 ... 36 V DC, the ultrasonic flow meter is highly versatile and can be used in a wide range of applications. It comes with a 2m connection cable and coupling pads for improved signal transmission.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eThis flow meter can be used in various applications, including heating systems, cooling water systems, and industrial processes where flow monitoring and control are necessary.\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch3 class=\"headline\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e- Measurement Range ±0.1 m\/s ... ±5 m\/s\u003c\/div\u003e\n\u003cdiv\u003e- Display of Flow, Volume Flow\u003c\/div\u003e\n\u003cdiv\u003e- Pipe Size: DN4 \/ 1\/8\", DN8 \/ 1\/4\", DN10 \/ 3\/8\", DN15 \/ 1\/2\", DN20 \/ 3\/4\", DN25 \/ 1\"\u003c\/div\u003e\n\u003cdiv\u003e- Suitable for Various Pipe Materials and Media\u003c\/div\u003e\n\u003cdiv\u003e- Analog Output: 4 ... 20mA\u003c\/div\u003e\n\u003cdiv\u003e- Interface: RS485\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch3 class=\"headline\"\u003eSpecification\u003c\/h3\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable border=\"0\" bgcolor=\"#FFFFFF\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eVelocity m\/s\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 ... 5 m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.001 m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePipe Size\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eDN25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eGeneral Technical Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDisplay Type\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eOLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAnalog Output\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e4 ... 20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eData Interface\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eVoltage Supply\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e9 ... 36 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMaterials\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003ePVC, Steel, Stainless Steel, Copper, PVDF (Polyvinylidenfluorid), PFA (Perfluoralkoxy-Polymere), PTFE (Polytetrafluorethylen), PU (Polyurethane), Aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring Medium\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eWater, Seawater, Oil, User-defined (manual input of sound velocity for the medium)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMenu Language\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eEnglish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e515 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDevice Weight with Accessories\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e652 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDevice Weight with Accessories and Packaging\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e892 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e110 x 58 x 67 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions including Packaging (L x W x H)\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e210 x 153 x 104 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating Conditions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0 ... 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating Condition r.H.\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u0026lt; 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage Conditions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0 ... 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage Conditions r.H.\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u0026lt; 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ctable\u003e\n\u003cthead data-start=\"55\" data-end=\"87\"\u003e\n\u003ctr data-start=\"55\" data-end=\"87\"\u003e\n\u003cth data-start=\"55\" data-end=\"70\"\u003eModel\u003c\/th\u003e\n\u003cth data-start=\"70\" data-end=\"87\"\u003ePipe Size\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr data-start=\"122\" data-end=\"155\"\u003e\n\u003ctd\u003ePCE-UFM 4\u003c\/td\u003e\n\u003ctd\u003eDN4 \/ 1\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr data-start=\"156\" data-end=\"189\"\u003e\n\u003ctd\u003ePCE-UFM 8\u003c\/td\u003e\n\u003ctd\u003eDN8 \/ 1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr data-start=\"190\" data-end=\"223\"\u003e\n\u003ctd\u003ePCE-UFM 10\u003c\/td\u003e\n\u003ctd\u003eDN10 \/ 3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr data-start=\"224\" data-end=\"257\"\u003e\n\u003ctd\u003ePCE-UFM 15\u003c\/td\u003e\n\u003ctd\u003eDN15 \/ 1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr data-start=\"258\" data-end=\"291\"\u003e\n\u003ctd\u003ePCE-UFM 20\u003c\/td\u003e\n\u003ctd\u003eDN20 \/ 3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable style=\"width: 100.096%;\"\u003e\n\u003ctbody\u003e\n\u003ctr data-start=\"292\" data-end=\"325\" data-is-last-node=\"\"\u003e\n\u003ctd style=\"width: 50.22%;\"\u003ePCE-UFM 25\u003c\/td\u003e\n\u003ctd style=\"width: 49.4405%;\"\u003eDN25 \/ 1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"headline\"\u003eDelivery Scope\u003c\/h3\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e1 x Ultrasonic Flow Meter and Selected Sensor\u003c\/div\u003e\n\u003cdiv\u003e1 x 2m Connection Cable\u003c\/div\u003e\n\u003cdiv\u003e4 x Coupling Pads\u003c\/div\u003e\n\u003cdiv\u003e1 x User Manual\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-files\"\u003e\n\u003ch3 class=\"headline\"\u003eDownloads\u003c\/h3\u003e\n\u003cdiv class=\"pkdownloads\"\u003e\n\u003cdiv style=\"display: flex; gap: 20px;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/man-durchflussmesser-zum-festeinbau-pce-ufm-cu-pvc-series-de_eca5e15b-7b7c-4502-9894-dea5d4b88da3.pdf?v=1734157535\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_manual.webp?v=1733642254\" alt=\"\"\u003e \u003cspan\u003eManual\u003c\/span\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/datasheet-pce-ufm-25.pdf?v=1734157534\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_datasheet.webp?v=1733642254\" alt=\"\"\u003e \u003cspan\u003eDatasheet\u003c\/span\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"PCE","offers":[{"title":"DN4 \/ 1\/8\"","offer_id":48427340071141,"sku":"PCE-UFM 25","price":2710.0,"currency_code":"NZD","in_stock":true},{"title":"DN8 \/ 1\/4\"","offer_id":48427340103909,"sku":"PCE-UFM 26","price":2710.0,"currency_code":"NZD","in_stock":true},{"title":"DN10 \/ 3\/8\"","offer_id":48427340136677,"sku":"PCE-UFM 27","price":2710.0,"currency_code":"NZD","in_stock":true},{"title":"DN15 \/ 1\/2\"","offer_id":48427340169445,"sku":"PCE-UFM 28","price":2710.0,"currency_code":"NZD","in_stock":true},{"title":"DN20 \/ 3\/4\"","offer_id":48427340202213,"sku":"PCE-UFM 29","price":2710.0,"currency_code":"NZD","in_stock":true},{"title":"DN25 \/ 1\"","offer_id":48427340234981,"sku":"PCE-UFM 30","price":2710.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-ultrasonic-flow-meter-pce-ufm-10-6185001_3280781_30e63b8d-516e-4e17-b692-05d2ce5eb830.webp?v=1771407298"},{"product_id":"ultrasonic-flow-meter-pce-tds-100h","title":"Ultrasonic Flow Meter PCE-TDS 100H","description":"\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch2 class=\"headline\"\u003eDescription\u003c\/h2\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cp align=\"center\"\u003e\u003cstrong\u003ePCE-TDS 100H Ultrasonic Flow Meter\u003cbr\u003eMeasures liquid flow velocity in pipes and tubes with a diameter of 57 … 720 mm \/ ≈ 2 ... 28 in\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003eThis is a portable handheld clamp-on ultrasonic flow meter used for non-invasive, unobstructed and highly accurate measurements of the flow velocity of liquids in metal, plastic and rubber pipes and tubes with a diameter of 57 … 720 mm \/ approx. 2 ... 28 in. Ideal for use in oil and gas, water and wastewater, chemical, food and beverage, pharmaceutical, metals and mining, pulp and paper, power and heating, ventilation, air conditioning and refrigeration (HVACR) industries, this ultrasonic flow meter features user-friendly velcro-strap clamps that allow for quick and easy repositioning of the electroacoustic transducers.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eMeasurable liquids include: acetate, acetone, alcohol, ammonia, aniline, benzene, butyrate, chloroform, ethanol, ethyl alcohol, ethyl ether, ethylene glycol, freon R 12, petrol, glycerin, glycol, isobutanol, isobutane, isopentane, kerosene, linseed oil, methanol, methyl alcohol, engine oil, diesel oil, olive oil, peanut oil, paraffin oil, pentane, petroleum, 1-propanol, coolant, lubricating oil, silicone oil, transformer oil, trichlorethylene, 1, 1, 1 - trichloroethane, turpentine, distilled water and sea water.\u003c\/div\u003e\n\u003cbr\u003eCalculation of flow velocity according to the transit-time principle follows the equation:\u003cbr\u003e\n\u003cp align=\"center\"\u003e\u003cimg src=\"http:\/\/www.industrial-needs.com\/technical-data\/images\/ultrasonic-flow-meter-pce-tds-100h-calculation.jpg\" width=\"190\" height=\"45\" border=\"0\"\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003ev = measured velocity\u003cbr\u003eT1 = run time of the ultrasonic signal in the flow direction\u003cbr\u003eT2 = run time of the ultrasonic signal against the flow direction\u003cbr\u003eL = length of the ultrasonic wave\u003cbr\u003eα = ultrasonic signal angle to the flow\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003eThe transit-time principle requires pipes to be full and have no bubbles and no particles.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNote: To transfer data to a computer, SOFT-PCE-TDS software is required. This software is sold separately - see accessories for details.\u003c\/p\u003e\n\u003cp\u003eEach PCE-TDS series meter is assembled by PCE Instruments in Germany and and factory-calibrated (without any documentation). The reference display of the in-house test stand used by PCE for calibration has a valid DAkkS calibration certificate. This ensures traceability to the Physikalisch-Technische Bundesanstalt (PTB) German national standard. Please note that the meter's measured values depend on the pipe geometry, material and coating; the medium type, temperature and speed; and the sensor type and measuring method.\u003c\/p\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch3 class=\"headline\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"usertext\"\u003e- ideal for retrofitting\u003cbr\u003e- installation without process interruption \u003cbr\u003e- easy assembly \u003cbr\u003e- accurate and reliable\u003cbr\u003e- no pressure loss\u003cbr\u003e- maintenance-free, no moving parts\u003cbr\u003e- wear-free\u003cbr\u003e- portable devices for control measurements \u003cbr\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch3 class=\"headline\"\u003eSpecification\u003c\/h3\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eHandheld measuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-32 ... +32 m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.0001 m\/s, 0.00033 ft\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy for DN ≥ 50 mm:\u003cbr\u003efor DN \u0026lt; 50 mm:\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±1.5 % of measured value\u003cbr\u003e±3.5 % of measured value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eReproducibility\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±1.0 % of measured value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMedia\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003eAll liquids with an impurity \u0026lt;5% and a flow \u0026gt;0.03 m³\/h\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eFlow units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003eCubic meter [m³]\u003cbr\u003eLiter [l]\u003cbr\u003eGallon (USA) [gal]\u003cbr\u003eImperial gallon (UK) [igl]\u003cbr\u003eMillion USA gallon [mgl]\u003cbr\u003eCubic foot [cf]\u003cbr\u003eBarrel (USA) [bal]\u003cbr\u003eImperial barrel (UK) [ib]\u003cbr\u003eOil barrel [ob]\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eTime settings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003eper day [\/d]\u003cbr\u003eper hour [\/h]\u003cbr\u003eper minute [\/m]\u003cbr\u003eand per second [\/s]\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eData logger\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e60,000 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eInterface\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eUSB (for online measurement and reading of the internal memory)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eProtection\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIP 52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePower supply\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e3 x AA NiMH rechargeable battery \/ 2100 mAh (at full charge 12h running time)\u003cbr\u003e100 … 240 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e214 x 104 x 40 mm \/ 8.4 x 4.1 x 1.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e450 g \/ 15 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eSensor (only PCE-TDS 100 H)            \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003enominal width  DN 50 … 700, 57 … 720 mm \/ approx. 2 ... 28\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eTemperature of liquid\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-30 … 160 °C \/ -22 ... 320 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e50 x 45 x 45 mm \/ 1.9 x 1.7 x 1.7\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e260 g \/ 9oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch3 class=\"headline\"\u003eDelivery Scope\u003c\/h3\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Ultrasonic flow meter PCE-TDS 100H \u003cbr\u003e2 x Sensor TDS-M1 (PCE-TDS 100H)\u003cbr\u003e2 x 5 m \/ 16.4 ft transducer connection cables\u003cbr\u003e2 x Velcro cable ties\u003cbr\u003e1 x Power adapter\u003cbr\u003e1 x Ultrasound contact gel\u003cbr\u003e1 x PCE tape measure\u003cbr\u003e1 x Plastic case\u003cbr\u003e1 x User manual \u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-files\"\u003e\n\u003ch3 class=\"headline\"\u003e\n\u003cbr\u003eDownloads\u003c\/h3\u003e\n\u003cdiv class=\"pkdownloads\"\u003e\n    \u003cdiv style=\"display:flex; gap:20px;\"\u003e\n      \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/man-flow-meter-pce-tds-100h-hs-de-en.pdf?v=1734157770\"\u003e    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_manual.webp?v=1733642254\" alt=\"\"\u003e\n        \u003cspan\u003eManual\u003c\/span\u003e\n        \u003c\/a\u003e \n\n      \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/datasheet-pce-tds-100h.pdf?v=1734157769\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_datasheet.webp?v=1733642254\" alt=\" \"\u003e\n      \u003cspan\u003eDatasheet\u003c\/span\u003e\n      \u003c\/a\u003e\n\n      \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/man-software-pce-tds-100-h-hs-de-en.pdf?v=1734157769\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_manual_p1.gif?v=1733897432\" alt=\"\"\u003e\n  \u003cspan\u003eManual P1\u003c\/span\u003e\n  \u003c\/a\u003e \n\u003ca class=\"iframe-large\" href=\"https:\/\/www.youtube-nocookie.com\/embed\/tHxWMlsZtnQ?autoplay=1\u0026amp;rel=0\u0026amp;showinfo=0\u0026amp;\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_video.webp?v=1733723112\" alt=\"\"\u003e  \u003cspan\u003eVideo Quick Start\u003c\/span\u003e\u003c\/a\u003e\n\n  \u003ca class=\"iframe-large\" href=\"https:\/\/www.youtube-nocookie.com\/embed\/xIzCejPfsD0?autoplay=1\u0026amp;rel=0\u0026amp;showinfo=0\u0026amp;\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_video.webp?v=1733723112\" alt=\"\"\u003e  \u003cspan\u003eVideo\u003c\/span\u003e\u003c\/a\u003e\n\n     \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-files\"\u003e\n\u003cdiv class=\"pkdownloads\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"PCE","offers":[{"title":"Excluding Calibration Certificate","offer_id":48427340595429,"sku":"PCE-TDS 100H","price":3960.0,"currency_code":"NZD","in_stock":true},{"title":"Including Calibration Certificate","offer_id":48427340628197,"sku":"PCE-TDS 100H-ICA","price":4670.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-ultrasonic-flow-meter-pce-tds-100h-6161333_3081377.webp?v=1771407307"},{"product_id":"ultrasonic-flow-meter-kit-pce-tds-100hsh","title":"Ultrasonic Flow Meter Kit PCE-TDS 100HSH","description":"\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch2 class=\"headline\"\u003eDescription\u003c\/h2\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cp align=\"center\"\u003e\u003cstrong\u003ePCE-TDS 100HSH Ultrasonic Flow Meter Kit\u003cbr\u003eMeasures liquid flow velocity in pipes and tubes with a diameter of 20 … 720 mm (approx. 3\/4\" ... 28\")\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003ePCE-TDS 100HSH is a portable handheld clamp-on ultrasonic flow meter kit used for non-invasive, unobstructed and highly accurate measurements of the flow velocity of liquids in metal, plastic and rubber pipes and tubes with a diameter of 20 … 720 mm \/ approx. 3\/4\" ... 28\". Ideal for use in oil and gas, water and wastewater, chemical, food and beverage, pharmaceutical, metals and mining, pulp and paper, power and heating, ventilation, air conditioning and refrigeration (HVACR) industries, this ultrasonic flow meter kit features user-friendly velcro-strap clamps that allow for quick and easy repositioning of the electroacoustic transducers.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eMeasurable liquids include: acetate, acetone, alcohol, ammonia, aniline, benzene, butyrate, chloroform, ethanol, ethyl alcohol, ethyl ether, ethylene glycol, freon R 12, petrol, glycerin, glycol, isobutanol, isobutane, isopentane, kerosene, linseed oil, methanol, methyl alcohol, engine oil, diesel oil, olive oil, peanut oil, paraffin oil, pentane, petroleum, 1-propanol, coolant, lubricating oil, silicone oil, transformer oil, trichlorethylene, 1, 1, 1 - trichloroethane, turpentine, distilled water and sea water.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eCalculation of flow velocity according to the transit-time principle follows the equation:\u003c\/div\u003e\n\u003cp align=\"center\"\u003e\u003cimg src=\"http:\/\/www.industrial-needs.com\/technical-data\/images\/ultrasonic-flow-meter-pce-tds-100h-calculation.jpg\" width=\"190\" height=\"45\" border=\"0\"\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003ev = measured velocity\u003cbr\u003eT1 = run time of the ultrasonic signal in the flow direction\u003cbr\u003eT2 = run time of the ultrasonic signal against the flow direction\u003cbr\u003eL = length of the ultrasonic wave\u003cbr\u003eα = ultrasonic signal angle to the flow\u003c\/p\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003eThe transit-time principle requires pipes to be full and have no bubbles and no particles.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNote: To transfer data to a computer, SOFT-PCE-TDS software is required. SOFT-PCE-TDS software sold separately - see accessories for details.\u003c\/p\u003e\n\u003cp\u003eEach PCE-TDS series meter is assembled by PCE Instruments in Germany and and factory-calibrated (without any documentation). The reference display of the in-house test stand used by PCE for calibration has a valid DAkkS calibration certificate. This ensures traceability to the Physikalisch-Technische Bundesanstalt (PTB) German national standard. Please note that the meter's measured values depend on the pipe geometry, material and coating; the medium type, temperature and speed; and the sensor type and measuring method.\u003c\/p\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch3 class=\"headline\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"usertext\"\u003e- 0.5% linearity\u003cbr\u003e- 0.2% repeatability\u003cbr\u003e- Bi-directional flow measurement\u003cbr\u003e- Quick and adjustable response time\u003cbr\u003e- Eliminates interfering frequencies\u003cbr\u003e- Includes data logger functionality\u003cbr\u003e- Stores up to 2000 measurement values\u003cbr\u003e- Auto power-off battery-saving function (can be disabled)\u003cbr\u003e- Saves time- and date-stamped measurement data to internal memory\u003cbr\u003e- Rechargeable, battery-operated flow measuring device\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e Note\u003c\/strong\u003e: To transfer data to a computer, SOFT-PCE-TDS software is required. SOFT-PCE-TDS software sold separately - see accessories for details. \u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch3 class=\"headline\"\u003e\n\u003cbr\u003eSpecification\u003c\/h3\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e-32 ... 32 m\/s, -105 ... 105 ft\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.0001 m\/s, 0.00033 ft\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy for DN ≥ 50 mm:\u003c\/td\u003e\n\u003ctd\u003e± 1.5% of measured value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003efor DN \u0026lt; 50 mm:\u003c\/td\u003e\n\u003ctd\u003e± 3.5% of measured value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReproducibility\u003c\/td\u003e\n\u003ctd\u003e± 1.0% of measured value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits\u003c\/td\u003e\n\u003ctd\u003eMeters, feet, cubic meters, liters, cubic feet, gallon, oil barrel, liquid barrel, million gallon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time\u003c\/td\u003e\n\u003ctd\u003e0 ... 999 seconds, freely configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDN 15 ... 700, 20 … 720 mm \/ approx. 3\/4\" ... 28\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring media\u003c\/td\u003e\n\u003ctd\u003eAll liquids with an impurity \u0026lt;5% and a flow \u0026gt;0.03 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeads\u003c\/td\u003e\n\u003ctd\u003eType M1 and S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable length\u003c\/td\u003e\n\u003ctd\u003eApprox. 5 m \/ 16.4 ft each (x 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e4 x 16 LCD, 7 digits for net flow, positive and negative flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e3 x  AAA Ni-H rechargeable batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003eApprox. 10 hours continuous use at full charge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery charger\u003c\/td\u003e\n\u003ctd\u003e100 .. 240V \/ AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eRS-232C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eStores up to 60,000 values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing material\u003c\/td\u003e\n\u003ctd\u003eABS plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eDevice:\u003cbr\u003e100 x 66 x 20 mm \/ 3.93 x 2.60 x 0.79 in\u003cbr\u003eTransducers:\u003cbr\u003e2 x M1 each 60 x 45 x 45 mm \/ 2.36 x 1.77 x 1.77 in\u003cbr\u003e2 x S1 each 90 x 85 x 24 mm \/ 3.54 x 3.35 x 0.95 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temp.\u003c\/td\u003e\n\u003ctd\u003e0 ... 70ºC \/ 32 ... 158ºF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e514 g \/ 1.14 lb (with batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch3 class=\"headline\"\u003eDelivery Scope\u003c\/h3\u003e\n\u003cdiv class=\"usertext\"\u003e1 x PCE-TDS 100H Ultrasonic flow meter\u003cbr\u003e2 x Sensors TDS-M1\u003cbr\u003e2 x Sensors TDS-S1\u003cbr\u003e2 x 5 m \/ 16.4 ft transducer connection cables\u003cbr\u003e4 x Velcro-strap clamps\u003cbr\u003e3 x AAA Ni-H rechargeable batteries\u003cbr\u003e1 x Battery charger\u003cbr\u003e1 x Container of coupling gel\u003cbr\u003e1 x Measuring tape\u003cbr\u003e1 x Carrying case\u003cbr\u003e1 x User manual\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eNote\u003c\/strong\u003e: To transfer data to a computer, SOFT-PCE-TDS software is required. SOFT-PCE-TDS software sold separately - see accessories for details. \u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-files\"\u003e\n\u003ch3 class=\"headline\"\u003e\n\u003cbr\u003eDownloads\u003c\/h3\u003e\n\u003cdiv class=\"pkdownloads\"\u003e\n    \u003cdiv style=\"display:flex; gap:20px;\"\u003e\n      \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/man-flow-meter-pce-tds-100h-hs-de-en_e1f5442b-a78a-4da3-8de6-b68103807753.pdf?v=1734158505\"\u003e    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_manual.webp?v=1733642254\" alt=\"\"\u003e\n        \u003cspan\u003eManual\u003c\/span\u003e\n        \u003c\/a\u003e \n\n      \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/datasheet-pce-tds-100hsh.pdf?v=1734158504\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_datasheet.webp?v=1733642254\" alt=\" \"\u003e\n      \u003cspan\u003eDatasheet\u003c\/span\u003e\n      \u003c\/a\u003e\n\n      \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/man-flow-meter-pce-tds-100-software-de-en-1049710.pdf?v=1734158504\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_manual_p1.gif?v=1733897432\" alt=\"\"\u003e\n  \u003cspan\u003eManual P1\u003c\/span\u003e\n  \u003c\/a\u003e \n\n  \u003ca class=\"iframe-large\" href=\"https:\/\/www.youtube-nocookie.com\/embed\/tHxWMlsZtnQ?autoplay=1\u0026amp;rel=0\u0026amp;showinfo=0\u0026amp;\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_video.webp?v=1733723112\" alt=\"\"\u003e  \u003cspan\u003eVideo Quick Start\u003c\/span\u003e\u003c\/a\u003e\n\n      \u003ca class=\"iframe-large\" href=\"https:\/\/www.youtube-nocookie.com\/embed\/xIzCejPfsD0?autoplay=1\u0026amp;rel=0\u0026amp;showinfo=0\u0026amp;\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_video.webp?v=1733723112\" alt=\"\"\u003e  \u003cspan\u003eVideo\u003c\/span\u003e\u003c\/a\u003e\n     \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-files\" class=\"tab-pane clear fade in\"\u003e\n\u003cdiv class=\"pkdownloads\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"PCE","offers":[{"title":"Excluding Calibration Certificate","offer_id":48427340988645,"sku":"PCE-TDS 100HSH","price":4980.0,"currency_code":"NZD","in_stock":true},{"title":"Including Calibration Certificate","offer_id":48427341021413,"sku":"PCE-TDS 100HSH-ICA","price":5690.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-ultrasonic-flow-meter-pce-tds-100h-6161333_3081355_3f7fbdcb-abb5-4594-a82f-cebfd3243c9b.webp?v=1771407314"},{"product_id":"flow-meter-pce-tds-100hmhs","title":"Ultrasonic Flow Meter PCE-TDS 100HMHS","description":"\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch2 class=\"headline\"\u003eDescription\u003c\/h2\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eFlow Meter PCE-TDS 100HMHS\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAccording to the transit time difference method \/ To determine flow velocity and flow rate \/ Measuring method for liquids as homogeneous as possible\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eThe flow meter is required as part of a control measurement or to quickly determine the flow in a pipeline and is therefore a portable \/ easy-to-install measuring system. The flow meter works according to the transit time difference method. The measuring principle of the flow meter is quite simple. Measuring a pipe at an angle with the flow takes less time than measuring against the flow.\u003cbr\u003e\u003cbr\u003eThe stronger the current gets, the longer you need against it and the faster you get with it. The difference between the flow times with the flow or against it therefore depends directly on the flow speed of the river. The flow meter uses this effect to determine flow velocity and flow. Electro-acoustic transducers (\"Piëzo effect\") send and receive short ultrasonic pulses through the medium flowing in the pipe.\u003cbr\u003e\u003cbr\u003eThe transducers are offset in the longitudinal direction on both sides of the measuring pipe. The non-destructive working sensors are placed on the pipe and fastened e.g. by means of a cable tie. The display shows the flow rate within a short time. The flow meter can be used for measurements on metallic pipes, plastic pipes or rubber pipes.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eMeasurable liquids include\u003c\/strong\u003e: acetate, acetone, alcohol, ammonia, aniline, benzene, butyrate, chloroform, ethanol, ethyl alcohol, ethyl ether, ethylene glycol, freon R 12, petrol, glycerin, glycol, isobutanol, isobutane, isopentane, kerosene, linseed oil, methanol, methyl alcohol, engine oil, diesel oil, olive oil, peanut oil, paraffin oil, pentane, petroleum, 1-propanol, coolant, lubricating oil, silicone oil, transformer oil, trichlorethylene, 1, 1, 1 - trichloroethane, turpentine, distilled water and sea water.\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch3 class=\"headline\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"usertext\"\u003e- Ideal for retrofitting\u003cbr\u003e- Installation without process interruption\u003cbr\u003e- Easy construction\u003cbr\u003e- Accurate and reliable\u003cbr\u003e- No pressure loss\u003cbr\u003e- Maintenance-free, no moving parts\u003cbr\u003e- Wear-free\u003cbr\u003e- Portable devices for control measurements\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e Note\u003c\/strong\u003e: To transfer data to a computer, SOFT-PCE-TDS software is required. SOFT-PCE-TDS software sold separately - see accessories for details. \u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch3 class=\"headline\"\u003e\n\u003cbr\u003eSpecification\u003c\/h3\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eHand-held device measuring range  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-32 ... +32 m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.0001 m\/s, 0.00033 ft\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy for DN ≥ 50 mm:\u003cbr\u003efor DN \u0026lt; 50 mm: \u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±1.5% of the measured value\u003cbr\u003e±3.5% of the measured value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eReproducibility\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±1.0% of the measured value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMedia\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003eAll liquids with an impurity \u0026lt; 5% and a flow rate \u0026gt;0.03 m³\/h\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eUnits of flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003eCubic meter [m³]\u003cbr\u003eLiter [l]\u003cbr\u003eGallon (USA) [gal]\u003cbr\u003eImperial Gallon (UK) [igl]\u003cbr\u003eMillion USA Gallons [mgl]\u003cbr\u003eCubic feet [cf]\u003cbr\u003eBarrel (USA) [bal]\u003cbr\u003eImperial Barrel (UK) [ib]\u003cbr\u003eOil Barrel [ob]\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eTime setting\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003eper day [\/d]\u003cbr\u003eper hour [\/h]\u003cbr\u003eper minute [\/m]\u003cbr\u003eand per second [\/s]\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eData logger\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e60,000 measuring points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eInterface\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eUSB (for online measurement and readout of the internal memory)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eProtection class\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIP 52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePower supply\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e3 x AA NiMH batteries\/ 2100 mAh (12 h running time when fully charged)\u003cbr\u003e100 … 240 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e214 x 104 x 40 mm \/ 8.4 x 4.1 x 1.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e450 g \/ 15.9 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eSensor             \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003enominal width DN 20 ... 108, 50 ... 720 mm \/ 0.8 ... 4.2, 1.9 ... 28.3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eLiquid temperature\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-30 … 160 °C \/ -22 … 320 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e50 x 45 x 45 mm \/ 1.97 x 1.77 x 1.77\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e260 g \/ 9.2 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch3 class=\"headline\"\u003eDelivery Scope\u003c\/h3\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Flow Meter PCE-TDS 100HMHS\u003cbr\u003e1 x TDS-HM on-rail sensor set (50 ... 720 mm \/  0.8 ... 4.2\" pipe diameter)\u003cbr\u003e1 x TDS-HS on-rail sensor set (20 ... 108 mm \/ 1.9 ... 28.3\" pipe diameter)\u003cbr\u003e2 x 5 m \/ 16.4 ft connection cables\u003cbr\u003e2 x Velcro cable ties\u003cbr\u003e1 x Mains power adapter\u003cbr\u003e1 x Ultrasonic contact gel\u003cbr\u003e1 x PCE tape measure\u003cbr\u003e1 x Plastic case\u003cbr\u003e1 x Instruction manual\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eNote\u003c\/strong\u003e: To transfer data to a computer, SOFT-PCE-TDS software is required. SOFT-PCE-TDS software sold separately - see accessories for details. \u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-files\"\u003e\n\u003ch3 class=\"headline\"\u003e\n\u003cbr\u003eDownloads\u003c\/h3\u003e\n\u003cdiv class=\"pkdownloads\"\u003e\n    \u003cdiv style=\"display:flex; gap:20px;\"\u003e\n      \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/man-flow-meter-pce-tds-100h-hs-de-en_4d683872-fb87-4200-8d3c-50b9e0636dc5.pdf?v=1734159069\"\u003e    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_manual.webp?v=1733642254\" alt=\"\"\u003e\n        \u003cspan\u003eManual\u003c\/span\u003e\n        \u003c\/a\u003e \n\n      \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/datasheet-pce-tds-100hmhs.pdf?v=1734159069\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_datasheet.webp?v=1733642254\" alt=\" \"\u003e\n      \u003cspan\u003eDatasheet\u003c\/span\u003e\n      \u003c\/a\u003e\n\n      \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/man-flow-meter-pce-tds-100-software-de-en-1049710_72c1a037-a936-4970-ba43-00975da10478.pdf?v=1734159068\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_manual_p1.gif?v=1733897432\" alt=\"\"\u003e\n  \u003cspan\u003eManual P1\u003c\/span\u003e\n  \u003c\/a\u003e \n\n      \u003ca class=\"iframe-large\" href=\"https:\/\/www.youtube-nocookie.com\/embed\/tHxWMlsZtnQ?autoplay=1\u0026amp;rel=0\u0026amp;showinfo=0\u0026amp;\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_video.webp?v=1733723112\" alt=\"\"\u003e  \u003cspan\u003eVideo Quick Start\u003c\/span\u003e\u003c\/a\u003e\n\n  \u003ca class=\"iframe-large\" href=\"https:\/\/www.youtube-nocookie.com\/embed\/xIzCejPfsD0?autoplay=1\u0026amp;rel=0\u0026amp;showinfo=0\u0026amp;\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_video.webp?v=1733723112\" alt=\"\"\u003e  \u003cspan\u003eVideo\u003c\/span\u003e\u003c\/a\u003e\n     \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"PCE","offers":[{"title":"Excluding Calibration Certificate","offer_id":48427341218021,"sku":"PCE-TDS 100HMHS","price":6450.0,"currency_code":"NZD","in_stock":true},{"title":"Including Calibration Certificate","offer_id":48427341250789,"sku":"PCE-TDS 100HMHS-ICA","price":7150.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-flow-meter-pce-tds-100hmhs-6175837_3192859.webp?v=1771407324"},{"product_id":"flow-meter-pce-ufm-80pvc","title":"Ultrasonic Flow Meter PCE-UFM PVC \/ CU","description":"\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDescription\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-12 text-center\"\u003e\u003cstrong\u003eUltrasonic Flow Meter \/ PoE and sensor with 9 m Ethernet cable \/ measurement of flow rate and volume flow via ultrasound \/ simple operation via 4 keys\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-12 text-justify\"\u003e\n\u003cp\u003eOur Ultrasonic Flow Meter enables the measurement of flow velocity from 0.03 to 5 m\/s. It can be used for measurements on copper pipes with a diameter between 21 mm and 91mm. The Ultrasonic Flow Meter of the PCE-UFM-CU or PVC series uses the ultrasonic transit time method to determine velocity and flow volume. The flow meter has a separate external clamping device for easy installation without having to touch the liquid medium or stop the production. Special coupling pads ensure that this ultrasonic clamp-on system can also be used without contact gel.\u003cbr\u003e\u003cbr\u003eThe Ultrasonic Flow Meter is equipped with a 360° rotatable display that can be pointed in four directions (0°, 90°, 180°, 270°). The LCD colour display shows the flow velocity, date, time, signal quality, network connection status, instantaneous velocity and cumulative flow, among other parameters. The flow unit can be selected between m³, l and gal.\u003cbr\u003e\u003cbr\u003eThe Ultrasonic Flow Meter uses Power over Ethernet (PoE) for power supply and Ethernet communication to save data to the cloud. This allows users to access, manage and analyse their measurement data at any time and from any location via mobile devices or computers without interrupting production processes. In water and wastewater management, drinking water treatment or in industry, flow meters are used in processes where water is used as a coolant, cleaning agent or component of production processes. They help to optimise water consumption and control the process flow.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHighlights\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e- measurement range 0.03 ... 5 m\/s\u003c\/div\u003e\n\u003cdiv\u003e- display of flow velocity, volume flow\u003c\/div\u003e\n\u003cdiv\u003e- pipe size: See model table below\u003c\/div\u003e\n\u003cdiv\u003e- pipe material: copper or PVC. Depending on model selected\u003c\/div\u003e\n\u003cdiv\u003e- interface: Ethernet\u003c\/div\u003e\n\u003cdiv\u003e- incl. reusable coupling pads\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSpecification\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable border=\"0\" bgcolor=\"#fff\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eSpeed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasurement range up to  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0,03 ... 5 m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±2 % of Rd (0.3 ... 5 m\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eSpeed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasurement range up to  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0,1 ... 16 ft\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 ft\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±2 % of Rd (1.0 ... 16 ft\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eVolume flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasurement range up to  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0,35 ... 60 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0,01 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±2 % of Rd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eGeneral technical data\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDisplay type  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eLC colour display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDisplay size  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1,44 Inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDisplay resolution  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e128 x 128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eInterface  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eEthernet, PoE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMaterials  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasured medium  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eWater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eRepeatability  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0,2 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eCommunication  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eHTTP, MQTT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMenu language  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eEnglish, Chinese, English (GB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eProtection class (device)  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePower supply  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003ePoE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eConnector type  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1256 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating conditions  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-10 ... 50 °C , 0 ... 99 % RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage conditions  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-10 ... 50 °C , 0 ... 99 % RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"attribute\"\u003e\n\u003ctd valign=\"top\"\u003eDimensions ( L x W x D )  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e65 x 111 x 43 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ctable\u003e\n\u003cthead data-start=\"44\" data-end=\"114\"\u003e\n\u003ctr data-start=\"44\" data-end=\"114\"\u003e\n\u003cth data-start=\"44\" data-end=\"60\"\u003e\u003cstrong data-start=\"46\" data-end=\"55\"\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"60\" data-end=\"87\"\u003e\u003cstrong data-start=\"62\" data-end=\"79\"\u003ePVC Pipe Size\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"87\" data-end=\"114\"\u003e\u003cstrong data-start=\"89\" data-end=\"105\"\u003eCU Pipe Size\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr data-start=\"188\" data-end=\"260\"\u003e\n\u003ctd\u003ePCE-UFM 40\u003c\/td\u003e\n\u003ctd\u003eDN40 (46 ... 54 mm)\u003c\/td\u003e\n\u003ctd\u003eDN40 (35 ... 43 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr data-start=\"261\" data-end=\"333\"\u003e\n\u003ctd\u003ePCE-UFM 80\u003c\/td\u003e\n\u003ctd\u003eDN80 (83 ... 91 mm)\u003c\/td\u003e\n\u003ctd\u003eDN80 (72 ... 80 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr data-start=\"334\" data-end=\"406\"\u003e\n\u003ctd\u003ePCE-UFM 65\u003c\/td\u003e\n\u003ctd\u003eDN65 (72 ... 80 mm)\u003c\/td\u003e\n\u003ctd\u003eDN65 (59 ... 67 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr data-start=\"407\" data-end=\"479\"\u003e\n\u003ctd\u003ePCE-UFM 50\u003c\/td\u003e\n\u003ctd\u003eDN50 (59 ... 67 mm)\u003c\/td\u003e\n\u003ctd\u003eDN50 (46 ... 54 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr data-start=\"480\" data-end=\"552\"\u003e\n\u003ctd\u003ePCE-UFM 32\u003c\/td\u003e\n\u003ctd\u003eDN32 (35 ... 43 mm)\u003c\/td\u003e\n\u003ctd\u003eDN32 (28 ... 36 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr data-start=\"553\" data-end=\"625\"\u003e\n\u003ctd\u003ePCE-UFM 25\u003c\/td\u003e\n\u003ctd\u003eDN25 (28 ... 36 mm)\u003c\/td\u003e\n\u003ctd\u003eDN25 (21 ... 29 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr data-start=\"626\" data-end=\"698\" data-is-last-node=\"\"\u003e\n\u003ctd\u003ePCE-UFM 20\u003c\/td\u003e\n\u003ctd\u003eDN20 (21 ... 29 mm)\u003c\/td\u003e\n\u003ctd\u003eDN40 (35 ... 43 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1 class=\"headline\"\u003eDelivery Scope\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e1 x Ultrasonic Flow Meter PCE-UFM 65CU\u003c\/div\u003e\n\u003cdiv\u003e1 x sensor with Ethernet cable 9 m\u003c\/div\u003e\n\u003cdiv\u003e1 x PoE network cable 2 m\u003c\/div\u003e\n\u003cdiv\u003e1 x ultrasonic contact gel\u003c\/div\u003e\n\u003cdiv\u003e1 x silicone seal 1 m\u003c\/div\u003e\n\u003cdiv\u003e4 x coupling pad\u003c\/div\u003e\n\u003cdiv\u003e1 x Allen key\u003c\/div\u003e\n\u003cdiv\u003e1 x user manual\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eNote: The Android app \"dial Meter Tube\" can only be downloaded from our shop,\u003c\/div\u003e\n\u003cdiv\u003eunder Downloads!\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-files\"\u003e\n\u003ch1 class=\"headline\"\u003eDownloads\u003c\/h1\u003e\n\u003cdiv class=\"pkdownloads\"\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/www.pce-instruments.com\/english\/api\/getartfile?_fnr=3510341\u0026amp;_dsp=inline\" target=\"_blank\"\u003e\u003cbr\u003e\u003cspan class=\"mimetitle mimetitlet_custom_manual mimetitlel_EN\"\u003eManual\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.pce-instruments.com\/english\/api\/getartfile?_fnr=3425633\u0026amp;_dsp=inline\" target=\"_blank\"\u003e\u003cbr\u003e\u003cspan class=\"mimetitle mimetitlet_custom_datasheet mimetitlel_EN\"\u003eDatasheet\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.pce-instruments.com\/english\/api\/getartfile?_fnr=3425635\u0026amp;_dsp=inline\" target=\"_blank\"\u003e\u003cbr\u003e\u003cspan class=\"mimetitle mimetitlet_custom_certificate_ce mimetitlel_EN\"\u003eCE Certificate\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.pce-instruments.com\/english\/api\/getartfile?_fnr=3425637\u0026amp;_dsp=inline\" target=\"_blank\"\u003e\u003cbr\u003e\u003cspan class=\"mimetitle mimetitlet_custom_software mimetitlel_EN\"\u003eSoftware Manual\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"PCE","offers":[{"title":"PVC DN20 (21 ... 29 mm)","offer_id":48427344396517,"sku":"PCE-UFM 80PVC-1","price":3060.0,"currency_code":"NZD","in_stock":true},{"title":"PVC DN25 (28 ... 36 mm)","offer_id":48427344429285,"sku":"PCE-UFM 80PVC-2","price":3280.0,"currency_code":"NZD","in_stock":true},{"title":"PVC DN32 (35 ... 43 mm)","offer_id":48427344462053,"sku":"PCE-UFM 80PVC-3","price":3570.0,"currency_code":"NZD","in_stock":true},{"title":"PVC DN40 (46 ... 54 mm)","offer_id":48427344494821,"sku":"PCE-UFM 80PVC-4","price":3770.0,"currency_code":"NZD","in_stock":true},{"title":"PVC DN50 (59 ... 67 mm)","offer_id":48427344527589,"sku":"PCE-UFM 80PVC-5","price":4060.0,"currency_code":"NZD","in_stock":true},{"title":"PVC DN65 (72 ... 80 mm)","offer_id":48427344560357,"sku":"PCE-UFM 80PVC-6","price":4320.0,"currency_code":"NZD","in_stock":true},{"title":"PVC DN80 (83 ... 91 mm)","offer_id":48427344593125,"sku":"PCE-UFM 80PVC-7","price":4720.0,"currency_code":"NZD","in_stock":true},{"title":"Copper DN20 \/ 3\/4\"","offer_id":48427344625893,"sku":"PCE-UFM 80PVC-8","price":3060.0,"currency_code":"NZD","in_stock":true},{"title":"Copper DN25 (21 ... 29 mm)","offer_id":48427344658661,"sku":"PCE-UFM 80PVC-9","price":3280.0,"currency_code":"NZD","in_stock":true},{"title":"Copper DN32 (28 ... 36 mm)","offer_id":48427344691429,"sku":"PCE-UFM 80PVC-10","price":3570.0,"currency_code":"NZD","in_stock":true},{"title":"Copper DN40 (35 ... 43 mm)","offer_id":48427344724197,"sku":"PCE-UFM 80PVC-11","price":3770.0,"currency_code":"NZD","in_stock":true},{"title":"Copper DN50 (46 ... 54 mm)","offer_id":48427344756965,"sku":"PCE-UFM 80PVC-12","price":4060.0,"currency_code":"NZD","in_stock":true},{"title":"Copper DN65 (59 ... 67 mm)","offer_id":48427344789733,"sku":"PCE-UFM 80PVC-13","price":4320.0,"currency_code":"NZD","in_stock":true},{"title":"Copper DN80 (72 ... 80 mm)","offer_id":48427344822501,"sku":"PCE-UFM 80PVC-14","price":4720.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-flow-meter-pce-ufm-80cu-6214779_3427435_d5933987-b5d5-409c-b35b-cd03cea2366a.webp?v=1771407414"},{"product_id":"ultrasonic-flow-meter-pce-tds-75","title":"Ultrasonic Flow Meter PCE-TDS 75","description":"\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch2 class=\"headline\"\u003eDescription\u003c\/h2\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e\u003cstrong\u003eUltrasonic Flow Meter PCE-TDS 75\u003cbr\u003eFlow meter for fixed installation \/ Various process connection options \/ Measurement accuracy of 1% \/ Up to a pipe diameter of 1200 mm (47.2 in) \/ Flow rate determination\u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv\u003eThe flow measuring device is a measuring device for fixed installation. The flow rate of liquids in pipes can be determined with this flow meter. The sensors from the flow meter can be mounted directly on the pipes to be measured without having to cut them open. This enables the flow meter to be installed even during operation. \u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eAnother special feature of the flow meter are the different outputs. It is possible to get the flow rate converted by the flow meter into an analog 4… 20-mA signal. Any other measurement value can be transmitted via the pulse output (OCT) from the flow meter. It is also possible to receive the measured values ​​directly via the Modbus outputs RS232 and RS485. This allows the flow meter to be integrated directly into the process control. \u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch3 class=\"headline\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"usertext\"\u003e- Flow meter for fixed installation\u003cbr\u003e- Different outputs for process connection\u003cbr\u003e- For fixed installation\u003cbr\u003e- For pipe diameters 25 ... 1200 mm \/ 1 in ... 47.2 in \u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch3 class=\"headline\"\u003e\n\u003cbr\u003eSpecification\u003c\/h3\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv class=\"tab-pane fade in  active\" id=\"tab-customdata3\"\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable cellspacing=\"0\" border=\"0\" bgcolor=\"#FFFFFF\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable cellspacing=\"0\" border=\"0\" bgcolor=\"#FFFFFF\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eMeasuring range           \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± 0.03 ... ± 5 m \/ s (± 0.09 ... ± 16 ft \/ s)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eMeasurement accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± 1% of the measured value\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eRepeatability   \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0.2%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003ePipe diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e25 ... 1200 mm (1 ... 48 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eAnalog output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0\/4 ... 20 mA (maximum load 750 Ω)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003ePulse output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0 ... 9999 Hz OCT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e(Frequency limits are adjustable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eRelay output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e1 A at 125V AC, 2 A at 30V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eMaximum frequency 1 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eCommunication interface                \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eRS232 \u0026amp; RS485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003ePower supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e10 ... 36V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003ePower consumption   \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e1 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eLCD, 256 x 128 pixels, with backlight\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eAmbient conditions base                              \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cspan\u003e-40 ... 60°C \/ -40 ... 140°F\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0 ... 99% RH non-condensing\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eAmbient conditions sensor \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cspan\u003e-40 ... 80°C \/ -40 ... 176° F\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0 ... 99% RH non-condensing\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eHousing material base\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003ePC \/ ABS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eProtection class base  \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eIP 65\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eProtection class sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eIP 68\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eCable length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e9 m \/ 30 ft\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e16 x 23 x 28 cm \/ 6.3 x 9.1 x 11\"\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e3.2 kg \/ 7.1 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch3 class=\"headline\"\u003eDelivery Scope\u003c\/h3\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Ultrasonic flow meter PCE-TDS 75\u003cbr\u003e2 x Flow sensors\u003cbr\u003e1 x Wall mounting set\u003cbr\u003e2 x Hose clamps\u003cbr\u003e1 x Instruction manual \u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-files\"\u003e\n\u003ch3 class=\"headline\"\u003e\n\u003cbr\u003eDownloads\u003c\/h3\u003e\n\u003cdiv class=\"pkdownloads\"\u003e\n\u003cdiv style=\"display: flex; gap: 20px;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/man-ultrasonic-flow-meter-pce-tds-75-en.pdf?v=1734167693\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_manual.webp?v=1733642254\" alt=\"\"\u003e \u003cspan\u003eManual\u003c\/span\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/datasheet-pce-tds-75.pdf?v=1734167693\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_datasheet.webp?v=1733642254\" alt=\"\"\u003e \u003cspan\u003eDatasheet\u003c\/span\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"PCE","offers":[{"title":"Excluding Calibration Certificate","offer_id":48427345150181,"sku":"PCE-TDS 75","price":4410.0,"currency_code":"NZD","in_stock":true},{"title":"Including Calibration Certificate","offer_id":48427345182949,"sku":"PCE-TDS 75-ICA","price":5340.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-ultrasonic-flow-meter-pce-tds-75-6172443_3161679.webp?v=1771407422"},{"product_id":"doppler-portable-ultrasonic-flow-meter-duf901-ep-01-ep-copy","title":"Ultrasonic Doppler Flow Meter DUF901-EC","description":"\u003ch3 data-start=\"421\" data-end=\"451\"\u003e\u003cstrong data-start=\"425\" data-end=\"449\"\u003eProduct Description:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"452\" data-end=\"985\"\u003eThe \u003cstrong data-start=\"456\" data-end=\"511\"\u003eDUF901-EC Doppler Wall-Mounted Ultrasonic Flowmeter\u003c\/strong\u003e is engineered for non-intrusive, accurate flow measurement in full pipes carrying dirty or aerated liquids. Designed with a clamp-on sensor, it allows for easy installation without disrupting flow. Ideal for industrial environments, the DUF901-EC supports a wide pipe diameter range (40–4000 mm) and measures flow rates from 0.05 to 12 m\/s. Its wall-mounted enclosure and user-friendly configuration make it a reliable solution for continuous and demanding flow monitoring.\u003c\/p\u003e\n\u003cp data-start=\"987\" data-end=\"1184\"\u003eWhether you're working with raw sewage, chemical slurries, or mining recirculation systems, this Doppler ultrasonic flowmeter delivers precise and stable readings using advanced Doppler technology.\u003c\/p\u003e\n\u003chr data-start=\"1186\" data-end=\"1189\"\u003e\n\u003ch3 data-start=\"1191\" data-end=\"1214\"\u003e\u003cstrong data-start=\"1195\" data-end=\"1212\"\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1215\" data-end=\"1973\"\u003e\n\u003cli data-start=\"1215\" data-end=\"1289\"\u003e\n\u003cp data-start=\"1217\" data-end=\"1289\"\u003e\u003cstrong data-start=\"1217\" data-end=\"1245\"\u003eWide Pipe Compatibility:\u003c\/strong\u003e Supports pipe sizes from 40 mm to 4000 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1290\" data-end=\"1388\"\u003e\n\u003cp data-start=\"1292\" data-end=\"1388\"\u003e\u003cstrong data-start=\"1292\" data-end=\"1322\"\u003eNon-Invasive Installation:\u003c\/strong\u003e Clamp-on transducer – no pipe cutting or system shutdown needed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1389\" data-end=\"1476\"\u003e\n\u003cp data-start=\"1391\" data-end=\"1476\"\u003e\u003cstrong data-start=\"1391\" data-end=\"1422\"\u003eDirty Liquid Compatibility:\u003c\/strong\u003e Handles fluids with air bubbles or suspended solids\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1477\" data-end=\"1566\"\u003e\n\u003cp data-start=\"1479\" data-end=\"1566\"\u003e\u003cstrong data-start=\"1479\" data-end=\"1510\"\u003eHigh-Temperature Tolerance:\u003c\/strong\u003e Operates with liquid temperatures from -35°C to 200°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1567\" data-end=\"1639\"\u003e\n\u003cp data-start=\"1569\" data-end=\"1639\"\u003e\u003cstrong data-start=\"1569\" data-end=\"1604\"\u003eExcellent Low-Flow Sensitivity:\u003c\/strong\u003e Accurate from as low as 0.05 m\/s\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1640\" data-end=\"1701\"\u003e\n\u003cp data-start=\"1642\" data-end=\"1701\"\u003e\u003cstrong data-start=\"1642\" data-end=\"1665\"\u003eFast Response Time:\u003c\/strong\u003e Configurable between 2–60 seconds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1702\" data-end=\"1776\"\u003e\n\u003cp data-start=\"1704\" data-end=\"1776\"\u003e\u003cstrong data-start=\"1704\" data-end=\"1722\"\u003eDurable Build:\u003c\/strong\u003e IP66 wall-mount transmitter with fiberglass housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1777\" data-end=\"1833\"\u003e\n\u003cp data-start=\"1779\" data-end=\"1833\"\u003e\u003cstrong data-start=\"1779\" data-end=\"1800\"\u003eFlexible Outputs:\u003c\/strong\u003e 4-20mA, Relay, and OCT outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1834\" data-end=\"1911\"\u003e\n\u003cp data-start=\"1836\" data-end=\"1911\"\u003e\u003cstrong data-start=\"1836\" data-end=\"1853\"\u003eSimple Setup:\u003c\/strong\u003e LCD display with 4-button keypad for easy configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1912\" data-end=\"1973\"\u003e\n\u003cp data-start=\"1914\" data-end=\"1973\"\u003e\u003cstrong data-start=\"1914\" data-end=\"1939\"\u003eAccurate Measurement:\u003c\/strong\u003e Up to ±2.0% full-scale accuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1975\" data-end=\"1978\"\u003e\n\u003ch3 data-start=\"1980\" data-end=\"2005\"\u003e\u003cstrong data-start=\"1984\" data-end=\"2003\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"2007\" data-end=\"2025\"\u003e\u003cstrong data-start=\"2007\" data-end=\"2023\"\u003eTransmitter:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2026\" data-end=\"2565\"\u003e\n\u003cli data-start=\"2026\" data-end=\"2075\"\u003e\n\u003cp data-start=\"2028\" data-end=\"2075\"\u003e\u003cstrong data-start=\"2028\" data-end=\"2054\"\u003eMeasurement Principle:\u003c\/strong\u003e Doppler Ultrasonic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2076\" data-end=\"2110\"\u003e\n\u003cp data-start=\"2078\" data-end=\"2110\"\u003e\u003cstrong data-start=\"2078\" data-end=\"2093\"\u003eFlow Range:\u003c\/strong\u003e 0.05 to 12 m\/s\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2111\" data-end=\"2145\"\u003e\n\u003cp data-start=\"2113\" data-end=\"2145\"\u003e\u003cstrong data-start=\"2113\" data-end=\"2126\"\u003eAccuracy:\u003c\/strong\u003e ±2.0% Full Scale\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2146\" data-end=\"2184\"\u003e\n\u003cp data-start=\"2148\" data-end=\"2184\"\u003e\u003cstrong data-start=\"2148\" data-end=\"2166\"\u003eRepeatability:\u003c\/strong\u003e 0.2% of reading\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2185\" data-end=\"2214\"\u003e\n\u003cp data-start=\"2187\" data-end=\"2214\"\u003e\u003cstrong data-start=\"2187\" data-end=\"2202\"\u003eResolution:\u003c\/strong\u003e 0.25 mm\/s\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2215\" data-end=\"2265\"\u003e\n\u003cp data-start=\"2217\" data-end=\"2265\"\u003e\u003cstrong data-start=\"2217\" data-end=\"2235\"\u003eResponse Time:\u003c\/strong\u003e 2–60 seconds (configurable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2266\" data-end=\"2328\"\u003e\n\u003cp data-start=\"2268\" data-end=\"2328\"\u003e\u003cstrong data-start=\"2268\" data-end=\"2280\"\u003eDisplay:\u003c\/strong\u003e LCD 2-line x 8 characters, rate\/total display\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2329\" data-end=\"2369\"\u003e\n\u003cp data-start=\"2331\" data-end=\"2369\"\u003e\u003cstrong data-start=\"2331\" data-end=\"2352\"\u003eEnclosure Rating:\u003c\/strong\u003e IP66 (EN60529)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2370\" data-end=\"2412\"\u003e\n\u003cp data-start=\"2372\" data-end=\"2412\"\u003e\u003cstrong data-start=\"2372\" data-end=\"2389\"\u003ePower Supply:\u003c\/strong\u003e 85–265V AC or 24V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2413\" data-end=\"2455\"\u003e\n\u003cp data-start=\"2415\" data-end=\"2455\"\u003e\u003cstrong data-start=\"2415\" data-end=\"2434\"\u003eOutput Signals:\u003c\/strong\u003e 4-20mA, Relay, OCT\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2456\" data-end=\"2494\"\u003e\n\u003cp data-start=\"2458\" data-end=\"2494\"\u003e\u003cstrong data-start=\"2458\" data-end=\"2477\"\u003eOperating Temp:\u003c\/strong\u003e -20°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2495\" data-end=\"2542\"\u003e\n\u003cp data-start=\"2497\" data-end=\"2542\"\u003e\u003cstrong data-start=\"2497\" data-end=\"2512\"\u003eDimensions:\u003c\/strong\u003e 244(H) x 196(W) x 114(D) mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2543\" data-end=\"2565\"\u003e\n\u003cp data-start=\"2545\" data-end=\"2565\"\u003e\u003cstrong data-start=\"2545\" data-end=\"2556\"\u003eWeight:\u003c\/strong\u003e 2.4 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2567\" data-end=\"2584\"\u003e\u003cstrong data-start=\"2567\" data-end=\"2582\"\u003eTransducer:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2585\" data-end=\"2953\"\u003e\n\u003cli data-start=\"2585\" data-end=\"2607\"\u003e\n\u003cp data-start=\"2587\" data-end=\"2607\"\u003e\u003cstrong data-start=\"2587\" data-end=\"2596\"\u003eType:\u003c\/strong\u003e Clamp-on\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2608\" data-end=\"2664\"\u003e\n\u003cp data-start=\"2610\" data-end=\"2664\"\u003e\u003cstrong data-start=\"2610\" data-end=\"2623\"\u003eMaterial:\u003c\/strong\u003e Aluminum (standard) \/ PEEK (high temp)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2665\" data-end=\"2803\"\u003e\n\u003cp data-start=\"2667\" data-end=\"2691\"\u003e\u003cstrong data-start=\"2667\" data-end=\"2689\"\u003eLiquid Temp Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2694\" data-end=\"2803\"\u003e\n\u003cli data-start=\"2694\" data-end=\"2746\"\u003e\n\u003cp data-start=\"2696\" data-end=\"2746\"\u003eStandard: -35°C to 85°C (short-term up to 120°C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2749\" data-end=\"2803\"\u003e\n\u003cp data-start=\"2751\" data-end=\"2803\"\u003eHigh Temp: -35°C to 200°C (short-term up to 250°C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2804\" data-end=\"2850\"\u003e\n\u003cp data-start=\"2806\" data-end=\"2850\"\u003e\u003cstrong data-start=\"2806\" data-end=\"2829\"\u003eIngress Protection:\u003c\/strong\u003e IP65 \/ IP67 \/ IP68\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2851\" data-end=\"2908\"\u003e\n\u003cp data-start=\"2853\" data-end=\"2908\"\u003e\u003cstrong data-start=\"2853\" data-end=\"2870\"\u003eCable Length:\u003c\/strong\u003e 10 m standard (extendable to 300 m)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2909\" data-end=\"2953\"\u003e\n\u003cp data-start=\"2911\" data-end=\"2953\"\u003e\u003cstrong data-start=\"2911\" data-end=\"2935\"\u003ePipe Diameter Range:\u003c\/strong\u003e 40 mm – 4000 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2955\" data-end=\"2958\"\u003e\n\u003ch3 data-start=\"2960\" data-end=\"2986\"\u003e\u003cstrong data-start=\"2964\" data-end=\"2984\"\u003eWhat’s Included:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2987\" data-end=\"3264\"\u003e\n\u003cli data-start=\"2987\" data-end=\"3054\"\u003e\n\u003cp data-start=\"2989\" data-end=\"3054\"\u003eWall-mounted DUF901-EC Doppler Ultrasonic Flowmeter transmitter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3055\" data-end=\"3126\"\u003e\n\u003cp data-start=\"3057\" data-end=\"3126\"\u003eClamp-on ultrasonic transducers (standard or high-temp as selected)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3127\" data-end=\"3167\"\u003e\n\u003cp data-start=\"3129\" data-end=\"3167\"\u003e10-meter transducer cable (standard)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3168\" data-end=\"3193\"\u003e\n\u003cp data-start=\"3170\" data-end=\"3193\"\u003eS-S belt for mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3194\" data-end=\"3210\"\u003e\n\u003cp data-start=\"3196\" data-end=\"3210\"\u003eCouplant gel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3211\" data-end=\"3226\"\u003e\n\u003cp data-start=\"3213\" data-end=\"3226\"\u003eUser manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3227\" data-end=\"3264\"\u003e\n\u003cp data-start=\"3229\" data-end=\"3264\"\u003eConfiguration keypad (integrated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3266\" data-end=\"3269\"\u003e\n\u003ch3 data-start=\"3271\" data-end=\"3307\"\u003e\u003cstrong data-start=\"3275\" data-end=\"3305\"\u003eIndustries \u0026amp; Applications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3308\" data-end=\"3672\"\u003e\n\u003cli data-start=\"3308\" data-end=\"3366\"\u003e\n\u003cp data-start=\"3310\" data-end=\"3366\"\u003e\u003cstrong data-start=\"3310\" data-end=\"3335\"\u003eWastewater Treatment:\u003c\/strong\u003e Raw sewage, activated sludge\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3367\" data-end=\"3420\"\u003e\n\u003cp data-start=\"3369\" data-end=\"3420\"\u003e\u003cstrong data-start=\"3369\" data-end=\"3391\"\u003eMining \u0026amp; Minerals:\u003c\/strong\u003e Mining recirculation water\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3421\" data-end=\"3469\"\u003e\n\u003cp data-start=\"3423\" data-end=\"3469\"\u003e\u003cstrong data-start=\"3423\" data-end=\"3440\"\u003ePulp \u0026amp; Paper:\u003c\/strong\u003e Slurries and fibrous flows\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3470\" data-end=\"3542\"\u003e\n\u003cp data-start=\"3472\" data-end=\"3542\"\u003e\u003cstrong data-start=\"3472\" data-end=\"3496\"\u003eChemical Processing:\u003c\/strong\u003e Chemical slurries, industrial waste streams\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3543\" data-end=\"3609\"\u003e\n\u003cp data-start=\"3545\" data-end=\"3609\"\u003e\u003cstrong data-start=\"3545\" data-end=\"3574\"\u003eEnvironmental Monitoring:\u003c\/strong\u003e Groundwater and drainage systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3610\" data-end=\"3672\"\u003e\n\u003cp data-start=\"3612\" data-end=\"3672\"\u003e\u003cstrong data-start=\"3612\" data-end=\"3643\"\u003eUtilities \u0026amp; Infrastructure:\u003c\/strong\u003e Non-potable water networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"_tableContainer_16hzy_1\"\u003e\n\u003cdiv class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"sticky end-(--thread-content-margin) h-0 self-end select-none\"\u003e\n\u003cdiv class=\"absolute end-0 flex items-end\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003eDownloads\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"absolute end-0 flex items-end\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003eData Sheet \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/DUF901-EC_Doppler_wall-mounted_ultrasonic_flowmeter.pdf?v=1762153832\" target=\"_blank\" rel=\"noopener\"\u003eLink\u003c\/a\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Flo Instru","offers":[{"title":"DUF901-EC","offer_id":48427369562341,"sku":"DUF901-EC","price":10270.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pl148381437-duf901_ec_dedicated_clmap_on_doppler_ultrasonic_flow_meters_with_oct_ouput.webp?v=1771408622"},{"product_id":"lc-series-oval-gear-flowmeter-high-precision-positive-displacement-flow-meter","title":"Oval Gear Flow Meter LC Series","description":"\u003ch2 data-start=\"550\" data-end=\"630\"\u003e\u003cstrong data-start=\"556\" data-end=\"628\"\u003eProduct Description:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"631\" data-end=\"931\"\u003eHigh-accuracy LC Series Oval Gear Flowmeter designed for measuring the flow of viscous, corrosive, and high-temperature liquids. Available in cast iron, cast steel, and stainless steel with analog, pulse, and digital output options. Ideal for petroleum, chemical, food, and pharmaceutical industries.\u003c\/p\u003e\n\u003chr data-start=\"933\" data-end=\"936\"\u003e\n\u003ch2 data-start=\"938\" data-end=\"967\"\u003e\u003cstrong data-start=\"944\" data-end=\"967\"\u003eProduct Highlights:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"969\" data-end=\"1469\"\u003e\n\u003cli data-start=\"969\" data-end=\"1031\"\u003e\n\u003cp data-start=\"971\" data-end=\"1031\"\u003e\u003cstrong data-start=\"971\" data-end=\"986\"\u003eFlow Range:\u003c\/strong\u003e 0.03–340 m³\/h (based on model \u0026amp; viscosity)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1032\" data-end=\"1064\"\u003e\n\u003cp data-start=\"1034\" data-end=\"1064\"\u003e\u003cstrong data-start=\"1034\" data-end=\"1047\"\u003eAccuracy:\u003c\/strong\u003e ±0.2% or ±0.5%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1065\" data-end=\"1109\"\u003e\n\u003cp data-start=\"1067\" data-end=\"1109\"\u003e\u003cstrong data-start=\"1067\" data-end=\"1086\"\u003eOutput Signals:\u003c\/strong\u003e Pulse, 4–20mA, RS485\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1110\" data-end=\"1178\"\u003e\n\u003cp data-start=\"1112\" data-end=\"1178\"\u003e\u003cstrong data-start=\"1112\" data-end=\"1126\"\u003eMaterials:\u003c\/strong\u003e Iron casting, cast steel, 304\/316 stainless steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1179\" data-end=\"1223\"\u003e\n\u003cp data-start=\"1181\" data-end=\"1223\"\u003e\u003cstrong data-start=\"1181\" data-end=\"1204\"\u003eViscosity Handling:\u003c\/strong\u003e Up to 2000 mPa·s\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1224\" data-end=\"1266\"\u003e\n\u003cp data-start=\"1226\" data-end=\"1266\"\u003e\u003cstrong data-start=\"1226\" data-end=\"1248\"\u003eTemperature Range:\u003c\/strong\u003e -20°C to +200°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1267\" data-end=\"1306\"\u003e\n\u003cp data-start=\"1269\" data-end=\"1306\"\u003e\u003cstrong data-start=\"1269\" data-end=\"1290\"\u003ePressure Ratings:\u003c\/strong\u003e Up to 6.3 MPa\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1307\" data-end=\"1363\"\u003e\n\u003cp data-start=\"1309\" data-end=\"1363\"\u003e\u003cstrong data-start=\"1309\" data-end=\"1327\"\u003eDisplay Types:\u003c\/strong\u003e Pointer, LCD, explosion-proof LCD\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1364\" data-end=\"1469\"\u003e\n\u003cp data-start=\"1366\" data-end=\"1469\"\u003e\u003cstrong data-start=\"1366\" data-end=\"1383\"\u003eApplications:\u003c\/strong\u003e Petroleum, chemicals, food \u0026amp; beverage, pharmaceuticals, commerce, and health sectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1471\" data-end=\"1474\"\u003e\n\u003ch2 data-start=\"1476\" data-end=\"1499\"\u003e\u003cstrong data-start=\"1482\" data-end=\"1499\"\u003eKey Features:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1501\" data-end=\"2348\"\u003e\n\u003cli data-start=\"1501\" data-end=\"1615\"\u003e\n\u003cp data-start=\"1503\" data-end=\"1615\"\u003e\u003cstrong data-start=\"1503\" data-end=\"1534\"\u003eHigh Precision Measurement:\u003c\/strong\u003e\u003cbr data-start=\"1534\" data-end=\"1537\"\u003eVolumetric positive displacement design ensures stable, repeatable readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1617\" data-end=\"1747\"\u003e\n\u003cp data-start=\"1619\" data-end=\"1747\"\u003e\u003cstrong data-start=\"1619\" data-end=\"1651\"\u003eWide Viscosity Adaptability:\u003c\/strong\u003e\u003cbr data-start=\"1651\" data-end=\"1654\"\u003eHandles liquids from 0.6 to 2000 mPa·s, including oils, acids, bases, and organic solvents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1749\" data-end=\"1875\"\u003e\n\u003cp data-start=\"1751\" data-end=\"1875\"\u003e\u003cstrong data-start=\"1751\" data-end=\"1791\"\u003eMultiple Materials \u0026amp; Configurations:\u003c\/strong\u003e\u003cbr data-start=\"1791\" data-end=\"1794\"\u003eChoose between iron, cast steel, or stainless steel bodies to suit your medium.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1877\" data-end=\"2018\"\u003e\n\u003cp data-start=\"1879\" data-end=\"2018\"\u003e\u003cstrong data-start=\"1879\" data-end=\"1902\"\u003eOutput Flexibility:\u003c\/strong\u003e\u003cbr data-start=\"1902\" data-end=\"1905\"\u003eSupports on-site mechanical reading or remote data transmission via analog (4–20mA), pulse, or RS485 protocols.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2020\" data-end=\"2131\"\u003e\n\u003cp data-start=\"2022\" data-end=\"2131\"\u003e\u003cstrong data-start=\"2022\" data-end=\"2050\"\u003eExplosion-Proof Options:\u003c\/strong\u003e\u003cbr data-start=\"2050\" data-end=\"2053\"\u003eAvailable in certified explosion-proof LCD types for hazardous environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2133\" data-end=\"2243\"\u003e\n\u003cp data-start=\"2135\" data-end=\"2243\"\u003e\u003cstrong data-start=\"2135\" data-end=\"2162\"\u003eHigh-Temperature Ready:\u003c\/strong\u003e\u003cbr data-start=\"2162\" data-end=\"2165\"\u003eSpecialized models with heat-jacket and radiator structures for up to 200°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2245\" data-end=\"2348\"\u003e\n\u003cp data-start=\"2247\" data-end=\"2348\"\u003e\u003cstrong data-start=\"2247\" data-end=\"2287\"\u003eVarious Mounting Sizes (DN10–DN200):\u003c\/strong\u003e\u003cbr data-start=\"2287\" data-end=\"2290\"\u003eAccommodates small-scale to industrial-scale operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2350\" data-end=\"2353\"\u003e\n\u003ch2 data-start=\"2355\" data-end=\"2390\"\u003e\u003cstrong data-start=\"2361\" data-end=\"2390\"\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2392\" data-end=\"2846\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2392\" data-end=\"2482\"\u003e\n\u003ctr data-start=\"2392\" data-end=\"2482\"\u003e\n\u003cth data-start=\"2392\" data-end=\"2411\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2394\" data-end=\"2410\"\u003eCaliber (mm)\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"2411\" data-end=\"2441\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2413\" data-end=\"2432\"\u003eViscosity Range\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"2441\" data-end=\"2482\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2443\" data-end=\"2464\"\u003eFlow Range (m³\/h)\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2574\" data-end=\"2846\"\u003e\n\u003ctr data-start=\"2574\" data-end=\"2664\"\u003e\n\u003ctd data-start=\"2574\" data-end=\"2593\" data-col-size=\"sm\"\u003eDN10–DN25\u003c\/td\u003e\n\u003ctd data-start=\"2593\" data-end=\"2623\" data-col-size=\"sm\"\u003e0.6–2 mPa·s \/ 2–2000 mPa·s\u003c\/td\u003e\n\u003ctd data-start=\"2623\" data-end=\"2664\" data-col-size=\"sm\"\u003e0.03–6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2665\" data-end=\"2755\"\u003e\n\u003ctd data-start=\"2665\" data-end=\"2684\" data-col-size=\"sm\"\u003eDN40–DN100\u003c\/td\u003e\n\u003ctd data-start=\"2684\" data-end=\"2714\" data-col-size=\"sm\"\u003e0.6–2 mPa·s \/ 2–2000 mPa·s\u003c\/td\u003e\n\u003ctd data-start=\"2714\" data-end=\"2755\" data-col-size=\"sm\"\u003e3–100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2756\" data-end=\"2846\"\u003e\n\u003ctd data-start=\"2756\" data-end=\"2775\" data-col-size=\"sm\"\u003eDN150–DN200\u003c\/td\u003e\n\u003ctd data-start=\"2775\" data-end=\"2805\" data-col-size=\"sm\"\u003e0.6–2 mPa·s \/ 2–2000 mPa·s\u003c\/td\u003e\n\u003ctd data-start=\"2805\" data-end=\"2846\" data-col-size=\"sm\"\u003e45–340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul data-start=\"2848\" data-end=\"3179\"\u003e\n\u003cli data-start=\"2848\" data-end=\"2899\"\u003e\n\u003cp data-start=\"2850\" data-end=\"2899\"\u003e\u003cstrong data-start=\"2850\" data-end=\"2871\"\u003eWorking Pressure:\u003c\/strong\u003e 1.6, 2.5, 4.0, or 6.3 MPa\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2900\" data-end=\"2961\"\u003e\n\u003cp data-start=\"2902\" data-end=\"2961\"\u003e\u003cstrong data-start=\"2902\" data-end=\"2928\"\u003eTemperature Tolerance:\u003c\/strong\u003e Up to 200°C (high-temp models)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2962\" data-end=\"3029\"\u003e\n\u003cp data-start=\"2964\" data-end=\"2979\"\u003e\u003cstrong data-start=\"2964\" data-end=\"2977\"\u003eAccuracy:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2982\" data-end=\"3029\"\u003e\n\u003cli data-start=\"2982\" data-end=\"3001\"\u003e\n\u003cp data-start=\"2984\" data-end=\"3001\"\u003eStandard: ±0.5%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3004\" data-end=\"3029\"\u003e\n\u003cp data-start=\"3006\" data-end=\"3029\"\u003eHigh Precision: ±0.2%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3030\" data-end=\"3179\"\u003e\n\u003cp data-start=\"3032\" data-end=\"3060\"\u003e\u003cstrong data-start=\"3032\" data-end=\"3058\"\u003eSignal Output Options:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3063\" data-end=\"3179\"\u003e\n\u003cli data-start=\"3063\" data-end=\"3093\"\u003e\n\u003cp data-start=\"3065\" data-end=\"3093\"\u003eGF-I \/ GF-II: Pulse output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3096\" data-end=\"3136\"\u003e\n\u003cp data-start=\"3098\" data-end=\"3136\"\u003eMF: 4–20mA output (2-wire or 3-wire)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3139\" data-end=\"3179\"\u003e\n\u003cp data-start=\"3141\" data-end=\"3179\"\u003eELZ: LCD display with optional RS485\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3181\" data-end=\"3184\"\u003e\n\u003ch2 data-start=\"3186\" data-end=\"3213\"\u003e\u003cstrong data-start=\"3192\" data-end=\"3213\"\u003eAvailable Models:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3215\" data-end=\"3833\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3215\" data-end=\"3276\"\u003e\n\u003ctr data-start=\"3215\" data-end=\"3276\"\u003e\n\u003cth data-start=\"3215\" data-end=\"3227\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3217\" data-end=\"3226\"\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"3227\" data-end=\"3276\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"3229\" data-end=\"3244\"\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3339\" data-end=\"3833\"\u003e\n\u003ctr data-start=\"3339\" data-end=\"3399\"\u003e\n\u003ctd data-start=\"3339\" data-end=\"3351\" data-col-size=\"sm\"\u003eLC-A\u003c\/td\u003e\n\u003ctd data-start=\"3351\" data-end=\"3399\" data-col-size=\"md\"\u003eStandard iron casting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3400\" data-end=\"3461\"\u003e\n\u003ctd data-start=\"3400\" data-end=\"3412\" data-col-size=\"sm\"\u003eLC-B\u003c\/td\u003e\n\u003ctd data-start=\"3412\" data-end=\"3461\" data-col-size=\"md\"\u003eStainless steel (304)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3462\" data-end=\"3523\"\u003e\n\u003ctd data-start=\"3462\" data-end=\"3474\" data-col-size=\"sm\"\u003eLC-C\u003c\/td\u003e\n\u003ctd data-start=\"3474\" data-end=\"3523\" data-col-size=\"md\"\u003eStainless steel (316)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3524\" data-end=\"3585\"\u003e\n\u003ctd data-start=\"3524\" data-end=\"3536\" data-col-size=\"sm\"\u003eLC-E\u003c\/td\u003e\n\u003ctd data-start=\"3536\" data-end=\"3585\" data-col-size=\"md\"\u003eCast steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3586\" data-end=\"3647\"\u003e\n\u003ctd data-start=\"3586\" data-end=\"3600\" data-col-size=\"sm\"\u003eLC-NA\/NE\/NB\u003c\/td\u003e\n\u003ctd data-start=\"3600\" data-end=\"3647\" data-col-size=\"md\"\u003eHigh-viscosity type (iron\/cast\/stainless)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3648\" data-end=\"3709\"\u003e\n\u003ctd data-start=\"3648\" data-end=\"3660\" data-col-size=\"sm\"\u003eLC-TA\/TE\u003c\/td\u003e\n\u003ctd data-start=\"3660\" data-end=\"3709\" data-col-size=\"md\"\u003eHigh-temperature type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3710\" data-end=\"3771\"\u003e\n\u003ctd data-start=\"3710\" data-end=\"3722\" data-col-size=\"sm\"\u003eLC-U\u003c\/td\u003e\n\u003ctd data-start=\"3722\" data-end=\"3771\" data-col-size=\"md\"\u003eJacketed heating type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3772\" data-end=\"3833\"\u003e\n\u003ctd data-start=\"3772\" data-end=\"3784\" data-col-size=\"sm\"\u003eLC-13\u003c\/td\u003e\n\u003ctd data-start=\"3784\" data-end=\"3833\" data-col-size=\"md\"\u003eTransmitter only (Pulse\/Analog Output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDownloads\u003c\/p\u003e\n\u003cp\u003eData Sheet \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/Oval_Gear_Flow_Meter_Manual_1.pdf?v=1762318036\"\u003eLink\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Sino-Inst","offers":[{"title":"Default Title","offer_id":48427369758949,"sku":"meter","price":9330.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/SI-3603-High-Viscosity-Oval-Gear-Flow-Meter-1.jpg?v=1771408634"},{"product_id":"ultrasonic-flow-meter-pce-tds-200-sm-dn15-100-dn50-700","title":"Ultrasonic Flow Meter PCE-TDS 200","description":"\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cp data-pm-slice=\"1 3 []\"\u003e\u003cspan\u003e\u003cstrong\u003eULTRASONIC FLOW METER PCE-TDS 200 SERIES\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFlow velocity \/ volume flow and volume \/ heat quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe flow meter has a measuring range of ±32 m\/s. With an accuracy of ±1.5 % f.s. for a pipe diameter of DN ≥50, ±3.5 % f.s. for a pipe diameter of DN \u0026lt;50 and a reproducibility of ±0.5 % f.s., the flow meter is a particularly precise measuring device. The installation aid graphically displays the signal quality from the flow meter. In addition, it is graphically displayed whether the sensors of the flow meter are positioned at the correct distance from each other. To carry out flow measurement with the flow meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMeasuring range: ±32 m\/s\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReproducibility of ±0.5 % of the measured value\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVarious ultrasonic probes available\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeat quantity measurement (only PCE-TDS 200+ series)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eData memory for 10 million measuring points (32 GB)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndividually adjustable alarm limits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUSB-C interface for data transfer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOptional: Software and calibration certificate ISO or DAkkS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTECHNICAL SPECIFICATIONS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFlow Measurement\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMeasuring range: ±32 m\/s\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResolution: 0.001 m\/s\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccuracy DN ≥ 50 mm: ±1.5 % f.s. (velocity \u0026gt;0.3 m\/s)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccuracy DN \u0026lt; 50 mm: ±3.5 % f. Mw. (speed \u0026gt;0.3 m\/s)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRepeatability: ±0.5 % f. Mw\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTemperature resistance: –30 … +160 ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMeasuring method: N \/ V \/ W \/ Z\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMedium\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePetrol, Diesel, Ethanol, Sea water, Methanol, Oil, Petroleum, Crude oil, Water\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUser defined (manual input of sound velocity from the medium)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable for all liquids with an impurity of less than 5%.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePipe Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCopper CU, Steel FE, Stainless steel VA, Aluminium AL, Brass ME, Cast iron CI, Iron FE, Nickel NI, Titanium TI, Zinc ZI\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAcrylic AC, Polyethylene PE, Polypropylene PP, Polyvinyl chloride PVC, Nylon NY\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUser defined (manual input of the sound velocity of the pipe material)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInner Pipe Lining\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNo lining, Epoxy resin, Rubber, Mortar, Polystyrene PS, Polyethylene PE, Polytetrafluoroethylene PTFE, Polyurethane PU, Polypropylene PP\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUser defined (manual input of the longitudinal sound velocity of the inner lining of the pipe)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTemperature (only PCE-TDS 200+)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMeasuring Range:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType B: 600 … 1800 ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType E: –100 … 900 ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType J: –100 … 1150 ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType K: –100 … 1370 ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType N: –100 … 1150 ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType R: 0 … 1700 ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType S: 0 … 1500 ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType T: –100 … +400 ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResolution: 0.1 ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccuracy:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType B: ±(0.5 % + 3 ºC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType E, J, K, N, T: ±(0.4 % + 1 ºC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType R, S: ±(0.5 % + 3 ºC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePCE-TDS 200 Measuring Parameters\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlow velocity, Volume flow, Volume\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePCE-TDS 200+ Measuring Parameters\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlow velocity, Volume flow, Volume, Temperature, Heat output, Heat quantity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eUnits:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLinear dimension: mm \/ in\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlow velocity: m\/s \/ ft\/s\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlow rate: m³ \/ l \/ gal \/ igl \/ mgl \/ cf \/ bal \/ ib \/ ob\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVolume: m³ \/ l \/ gal \/ igl \/ mgl \/ cf \/ bal \/ ib \/ ob\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTemperature: °C \/ °F\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeat quantity: K \/ kJ \/ MJ \/ Wh \/ kWh \/ MWh \/ Btu \/ kBtu \/ MBtu\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeat output: W \/ kW \/ MW \/ J\/h \/ kJ\/h \/ MJ\/h \/ Btu\/h \/ kBtu\/h \/ MBtu\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCost display: €, £, $, TL, Zł, ¥\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDate\/Time:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e second \/ minute \/ hour \/ day \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eDisplay:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e LCD of 2.8\" \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eUnits:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Metric \/ Imperial \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eMemory:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e 10 million values (32 GB) \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eMenu Languages:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e German, Chinese, Danish, English, Turkish, French, Italian, Japanese, Dutch, Polish, Portuguese, Russian, Spanish\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Conditions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTemperature: –20 ... +65 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHumidity: 10 … 95 % r.h., non-condensing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInterface: USB-C (for online measurement, memory readout, and battery charging)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProtection Class: IP52\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBattery: LiPo 3.7 V \/ 2500 mAh\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCharger: USB 5 V DC \/ 500 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOperating Time: approx. 10 hours\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDimensions: 165 × 85 × 32 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWeight: 255 g\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSensor Order Numbers \u0026amp; Details\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSensor\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eNominal Diameter (DN)\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eTemperature Range\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eRail Mount\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePCE-TDS 200 L SENSOR\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDN 300 … 6000\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e70 × 40 × 37 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–30 … +160 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePCE-TDS 200 M SENSOR\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDN 50 … 700\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e70 × 40 × 37 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–30 … +160 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePCE-TDS 200 MR SENSOR\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDN 50 … 700\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e280 × 60 × 40 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–30 … +160 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePCE-TDS 200 S SENSOR\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDN 15 … 100\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45 × 30 × 30 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–30 … +160 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePCE-TDS 200 SR SENSOR\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDN 15 … 100\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e198 × 45 × 25 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–30 … +160 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \u0026amp; Included Sensors\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003ePCE-TDS 200 (Standard Version)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eL: L SENSOR\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eM: M SENSOR\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eML: M + L SENSORS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMR: MR SENSOR\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eS: S SENSOR\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSL: S + L SENSORS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSM: S + M SENSORS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSML: S + M + L SENSORS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSR: SR SENSOR\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePCE-TDS 200+ (Version with Temperature Sensors)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eL: L SENSOR\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eM: M SENSOR\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eML: M + L SENSORS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMR: MR SENSOR\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eS: S SENSOR\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSL: S + L SENSORS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSM: S + M SENSORS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSML: S + M + L SENSORS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSR: SR SENSOR\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDelivery Scope\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × PCE-TDS 200 Ultrasonic Flow Meter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × Flow sensor(s) (based on selected model)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e2 × Temperature sensors TF-RA330 (only for 200+ versions)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e2 × 5 m connection cables\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e2 × Detachable cable ties\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × Power supply unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × USB-C cable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × Ultrasonic contact gel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × PCE measuring tape\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × Plastic transport case\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × Instruction manual\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCAL-PCE-TDS-ISO: ISO Calibration Certificate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCAL-PCE-TDS-DAkkS: DAkkS Calibration Certificate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCAL-T2: Calibration certificate for 2-channel thermometer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePCE-TDS 200 case: Spare transport case\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePCE-TDS 200 SW: Software\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTF-RA330: Temperature Contact Sensor Type T, 1 m\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTF-RA330-3: Temperature Contact Sensor Type T, 3 m\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTF-RA330-5: Temperature Contact Sensor Type T, 5 m\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTT-GEL: Ultrasonic Contact Gel (100 ml)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eK-Gel: High Temperature Coupling Gel (100 ml)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 class=\"headline\"\u003eDownloads\u003c\/h1\u003e\n\u003cdiv class=\"pkdownloads\"\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/www.pce-instruments.com\/english\/api\/getartfile?_fnr=3652189\u0026amp;_dsp=inline\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.pce-instruments.com\/english\/api\/getartfile?_fnr=3652195\u0026amp;_dsp=inline\" target=\"_blank\"\u003e\u003cspan class=\"mimetitle mimetitlet_custom_booklet mimetitlel_EN\"\u003eBrochure\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"PCE","offers":[{"title":"PCE-TDS 200 L (DN300…6000) \/ Without Calibration Ceriticate","offer_id":48427450269925,"sku":"PCE-TDS 200 L (DN300…6000)","price":5670.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200 L (DN300…6000) \/ With Calibration Certificate","offer_id":48427450302693,"sku":null,"price":6200.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200 M (DN50…700) \/ Without Calibration Ceriticate","offer_id":48427450335461,"sku":null,"price":5670.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200 M (DN50…700) \/ With Calibration Certificate","offer_id":48427450368229,"sku":null,"price":5920.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200 ML (DN50…700 \/ DN300…6000) \/ Without Calibration Ceriticate","offer_id":48427450400997,"sku":null,"price":6400.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200 ML (DN50…700 \/ DN300…6000) \/ With Calibration Certificate","offer_id":48427450433765,"sku":null,"price":7570.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200 S (DN15…100) \/ Without Calibration Ceriticate","offer_id":48427450466533,"sku":null,"price":5400.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200 S (DN15…100) \/ With Calibration Certificate","offer_id":48427450499301,"sku":null,"price":5920.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200 SL (DN15…100 \/ DN300…6000) \/ Without Calibration Ceriticate","offer_id":48427450532069,"sku":null,"price":6400.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200 SL (DN15…100 \/ DN300…6000) \/ With Calibration Certificate","offer_id":48427450564837,"sku":null,"price":7570.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200 SM (DN15…100 \/ DN50…700) \/ Without Calibration Ceriticate","offer_id":48427450597605,"sku":null,"price":6030.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200 SM (DN15…100 \/ DN50…700) \/ With Calibration Certificate","offer_id":48427450630373,"sku":null,"price":7250.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200 SML (DN15…100 \/ DN50…700 \/ DN300…6000) \/ Without Calibration Ceriticate","offer_id":48427450663141,"sku":null,"price":7880.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200 SML (DN15…100 \/ DN50…700 \/ DN300…6000) \/ With Calibration Certificate","offer_id":48427450695909,"sku":null,"price":8950.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200+ L (DN300…6000) \/ Without Calibration Ceriticate","offer_id":48427450728677,"sku":null,"price":8110.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200+ L (DN300…6000) \/ With Calibration Certificate","offer_id":48427450761445,"sku":null,"price":8530.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200+ M (DN50…700) \/ Without Calibration Ceriticate","offer_id":48427450794213,"sku":null,"price":7850.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200+ M (DN50…700) \/ With Calibration Certificate","offer_id":48427450826981,"sku":null,"price":8280.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200+ ML (DN50…700 \/ DN300…6000) \/ Without Calibration Ceriticate","offer_id":48427450859749,"sku":null,"price":8820.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200+ ML (DN50…700 \/ DN300…6000) \/ With Calibration Certificate","offer_id":48427450892517,"sku":null,"price":10090.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200+ S (DN15…100) \/ Without Calibration Ceriticate","offer_id":48427450925285,"sku":null,"price":7850.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200+ S (DN15…100) \/ With Calibration Certificate","offer_id":48427450958053,"sku":null,"price":8280.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200+ SL (DN15…100 \/ DN300…6000) \/ Without Calibration Ceriticate","offer_id":48427450990821,"sku":null,"price":8820.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200+ SL (DN15…100 \/ DN300…6000) \/ With Calibration Certificate","offer_id":48427451023589,"sku":null,"price":10090.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200+ SM (DN15…100 \/ DN50…700) \/ Without Calibration Ceriticate","offer_id":48427451056357,"sku":null,"price":8450.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200+ SM (DN15…100 \/ DN50…700) \/ With Calibration Certificate","offer_id":48427451089125,"sku":null,"price":9740.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200+ SML (DN15…100 \/ DN50…700 \/ DN300…6000) \/ Without Calibration Ceriticate","offer_id":48427451121893,"sku":null,"price":10310.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200+ SML (DN15…100 \/ DN50…700 \/ DN300…6000) \/ With Calibration Certificate","offer_id":48427451154661,"sku":null,"price":11890.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-portable-ultrasonic-flow-meter-pce-tds-200-sml-6109649_2695187_bdf3dbf6-1126-49d3-9dbc-3489cc75e6c4.webp?v=1771409667"},{"product_id":"ultrasonic-flow-meter-pce-tds-200-sm-dn15-100-dn50-700-dn300-6000-copy","title":"Ultrasonic Flow Meter PCE-TDS 200 Rail","description":"\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cp data-pm-slice=\"1 3 []\"\u003e\u003cspan\u003e\u003cstrong\u003eULTRASONIC FLOW METER PCE-TDS 200 SERIES RAIL MOUNT\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFlow velocity \/ volume flow and volume \/ heat quantity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe flow meter has a measuring range of ±32 m\/s. With an accuracy of ±1.5 % f.s. for a pipe diameter of DN ≥50, ±3.5 % f.s. for a pipe diameter of DN \u0026lt;50 and a reproducibility of ±0.5 % f.s., the flow meter is a particularly precise measuring device. The installation aid graphically displays the signal quality from the flow meter. In addition, it is graphically displayed whether the sensors of the flow meter are positioned at the correct distance from each other. To carry out flow measurement with the flow meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMeasuring range: ±32 m\/s\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReproducibility of ±0.5 % of the measured value\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVarious ultrasonic probes available\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeat quantity measurement (only PCE-TDS 200+ series)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eData memory for 10 million measuring points (32 GB)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndividually adjustable alarm limits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUSB-C interface for data transfer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOptional: Software and calibration certificate ISO or DAkkS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTECHNICAL SPECIFICATIONS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFlow Measurement\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMeasuring range: ±32 m\/s\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResolution: 0.001 m\/s\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccuracy DN ≥ 50 mm: ±1.5 % f.s. (velocity \u0026gt;0.3 m\/s)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccuracy DN \u0026lt; 50 mm: ±3.5 % f. Mw. (speed \u0026gt;0.3 m\/s)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRepeatability: ±0.5 % f. Mw\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTemperature resistance: –30 … +160 ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMeasuring method: N \/ V \/ W \/ Z\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMedium\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePetrol, Diesel, Ethanol, Sea water, Methanol, Oil, Petroleum, Crude oil, Water\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUser defined (manual input of sound velocity from the medium)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable for all liquids with an impurity of less than 5%.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePipe Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCopper CU, Steel FE, Stainless steel VA, Aluminium AL, Brass ME, Cast iron CI, Iron FE, Nickel NI, Titanium TI, Zinc ZI\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAcrylic AC, Polyethylene PE, Polypropylene PP, Polyvinyl chloride PVC, Nylon NY\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUser defined (manual input of the sound velocity of the pipe material)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInner Pipe Lining\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNo lining, Epoxy resin, Rubber, Mortar, Polystyrene PS, Polyethylene PE, Polytetrafluoroethylene PTFE, Polyurethane PU, Polypropylene PP\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUser defined (manual input of the longitudinal sound velocity of the inner lining of the pipe)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTemperature (only PCE-TDS 200+)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMeasuring Range:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType B: 600 … 1800 ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType E: –100 … 900 ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType J: –100 … 1150 ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType K: –100 … 1370 ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType N: –100 … 1150 ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType R: 0 … 1700 ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType S: 0 … 1500 ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType T: –100 … +400 ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResolution: 0.1 ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccuracy:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType B: ±(0.5 % + 3 ºC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType E, J, K, N, T: ±(0.4 % + 1 ºC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eType R, S: ±(0.5 % + 3 ºC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePCE-TDS 200 Measuring Parameters\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlow velocity, Volume flow, Volume\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePCE-TDS 200+ Measuring Parameters\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlow velocity, Volume flow, Volume, Temperature, Heat output, Heat quantity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eUnits:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLinear dimension: mm \/ in\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlow velocity: m\/s \/ ft\/s\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlow rate: m³ \/ l \/ gal \/ igl \/ mgl \/ cf \/ bal \/ ib \/ ob\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVolume: m³ \/ l \/ gal \/ igl \/ mgl \/ cf \/ bal \/ ib \/ ob\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTemperature: °C \/ °F\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeat quantity: K \/ kJ \/ MJ \/ Wh \/ kWh \/ MWh \/ Btu \/ kBtu \/ MBtu\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeat output: W \/ kW \/ MW \/ J\/h \/ kJ\/h \/ MJ\/h \/ Btu\/h \/ kBtu\/h \/ MBtu\/h\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCost display: €, £, $, TL, Zł, ¥\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDate\/Time:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e second \/ minute \/ hour \/ day \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eDisplay:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e LCD of 2.8\" \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eUnits:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Metric \/ Imperial \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eMemory:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e 10 million values (32 GB) \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eMenu Languages:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e German, Chinese, Danish, English, Turkish, French, Italian, Japanese, Dutch, Polish, Portuguese, Russian, Spanish\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Conditions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTemperature: –20 ... +65 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHumidity: 10 … 95 % r.h., non-condensing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInterface: USB-C (for online measurement, memory readout, and battery charging)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProtection Class: IP52\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBattery: LiPo 3.7 V \/ 2500 mAh\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCharger: USB 5 V DC \/ 500 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOperating Time: approx. 10 hours\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDimensions: 165 × 85 × 32 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWeight: 255 g\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSensor Order Numbers \u0026amp; Details\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSensor\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eNominal Diameter (DN)\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eTemperature Range\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eRail Mount\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePCE-TDS 200 L SENSOR\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDN 300 … 6000\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e70 × 40 × 37 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–30 … +160 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePCE-TDS 200 M SENSOR\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDN 50 … 700\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e70 × 40 × 37 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–30 … +160 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePCE-TDS 200 MR SENSOR\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDN 50 … 700\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e280 × 60 × 40 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–30 … +160 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePCE-TDS 200 S SENSOR\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDN 15 … 100\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45 × 30 × 30 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–30 … +160 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePCE-TDS 200 SR SENSOR\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDN 15 … 100\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e198 × 45 × 25 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–30 … +160 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \u0026amp; Included Sensors\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003ePCE-TDS 200 (Standard Version)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eL: L SENSOR\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eM: M SENSOR\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eML: M + L SENSORS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMR: MR SENSOR\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eS: S SENSOR\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSL: S + L SENSORS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSM: S + M SENSORS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSML: S + M + L SENSORS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSR: SR SENSOR\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePCE-TDS 200+ (Version with Temperature Sensors)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eL: L SENSOR\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eM: M SENSOR\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eML: M + L SENSORS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMR: MR SENSOR\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eS: S SENSOR\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSL: S + L SENSORS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSM: S + M SENSORS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSML: S + M + L SENSORS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSR: SR SENSOR\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDelivery Scope\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × PCE-TDS 200 Ultrasonic Flow Meter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × Flow sensor(s) (based on selected model)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e2 × Temperature sensors TF-RA330 (only for 200+ versions)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e2 × 5 m connection cables\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e2 × Detachable cable ties\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × Power supply unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × USB-C cable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × Ultrasonic contact gel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × PCE measuring tape\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × Plastic transport case\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × Instruction manual\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCAL-PCE-TDS-ISO: ISO Calibration Certificate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCAL-PCE-TDS-DAkkS: DAkkS Calibration Certificate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCAL-T2: Calibration certificate for 2-channel thermometer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePCE-TDS 200 case: Spare transport case\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePCE-TDS 200 SW: Software\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTF-RA330: Temperature Contact Sensor Type T, 1 m\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTF-RA330-3: Temperature Contact Sensor Type T, 3 m\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTF-RA330-5: Temperature Contact Sensor Type T, 5 m\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTT-GEL: Ultrasonic Contact Gel (100 ml)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eK-Gel: High Temperature Coupling Gel (100 ml)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 class=\"headline\"\u003eDownloads\u003c\/h1\u003e\n\u003cdiv class=\"pkdownloads\"\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/www.pce-instruments.com\/english\/api\/getartfile?_fnr=3652189\u0026amp;_dsp=inline\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.pce-instruments.com\/english\/api\/getartfile?_fnr=3652195\u0026amp;_dsp=inline\" target=\"_blank\"\u003e\u003cspan class=\"mimetitle mimetitlet_custom_booklet mimetitlel_EN\"\u003eBrochure\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"PCE","offers":[{"title":"PCE-TDS 200 MR (DN50…700) \/ Without Calibration Certificate","offer_id":48427452563685,"sku":"PCE-TDS 200 MR (DN50…700)","price":6250.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200 MR (DN50…700) \/ With Calibration Certificate","offer_id":48427452596453,"sku":null,"price":6740.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200 SR (DN15…100) \/ Without Calibration Certificate","offer_id":48427452629221,"sku":null,"price":5910.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200 SR (DN15…100) \/ With Calibration Certificate","offer_id":48427452661989,"sku":null,"price":6380.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200+ MR (DN50…700) \/ Without Calibration Certificate","offer_id":48427452694757,"sku":null,"price":6400.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200+ MR (DN50…700) \/ With Calibration Certificate","offer_id":48427452727525,"sku":null,"price":9090.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200+ SR (DN15…100) \/ Without Calibration Certificate","offer_id":48427452760293,"sku":null,"price":8330.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-TDS 200+ SR (DN15…100) \/ With Calibration Certificate","offer_id":48427452793061,"sku":null,"price":8750.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-ultrasonic-flow-meter-pce-tds-200-mr-6105336_2625308_1.webp?v=1771409733"},{"product_id":"doppler-portable-ultrasonic-flow-meter-duf901-ep-01-ep","title":"Doppler Ultrasonic Flow Meter DUF901-EP","description":"\u003ch3 data-start=\"350\" data-end=\"375\" class=\"\"\u003eDescription:\u003c\/h3\u003e\n\u003cp data-start=\"376\" data-end=\"615\" class=\"\"\u003eMeasure flow in pipes from 40 to 4000mm with the DUF901-EP Doppler Ultrasonic Flow Meter. Non-invasive, portable, and ideal for dirty liquids with air bubbles or solids. Clamp-on installation, high accuracy, and up to 50-hour battery life.\u003c\/p\u003e\n\u003chr data-start=\"617\" data-end=\"620\" class=\"\"\u003e\n\u003ch2 data-start=\"622\" data-end=\"673\" class=\"\"\u003eDUF901-EP Doppler Portable Ultrasonic Flow Meter\u003c\/h2\u003e\n\u003cp data-start=\"675\" data-end=\"739\" class=\"\"\u003e\u003cstrong data-start=\"675\" data-end=\"739\"\u003ePortable. Non-Invasive. Designed for Dirty \u0026amp; Slurry Liquids.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"741\" data-end=\"1072\" class=\"\"\u003eThe \u003cstrong data-start=\"745\" data-end=\"797\"\u003eDUF901-EP Doppler Portable Ultrasonic Flow Meter\u003c\/strong\u003e is engineered for accurate and reliable volumetric flow measurement in full pipelines containing dirty liquids with suspended solids or air bubbles. The clamp-on transducer allows easy installation without disrupting the flow, making it ideal for a wide range of industries.\u003c\/p\u003e\n\u003cp data-start=\"1074\" data-end=\"1268\" class=\"\"\u003eIt features a clear LCD display, 4-20mA, and OCT outputs, along with a rechargeable battery for up to \u003cstrong data-start=\"1176\" data-end=\"1212\"\u003e50 hours of continuous operation\u003c\/strong\u003e, ensuring both flexibility and efficiency in the field.\u003c\/p\u003e\n\u003chr data-start=\"1270\" data-end=\"1273\" class=\"\"\u003e\n\u003ch3 data-start=\"1275\" data-end=\"1291\" class=\"\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-start=\"1293\" data-end=\"1329\" class=\"\"\u003e✅ \u003cstrong data-start=\"1295\" data-end=\"1327\"\u003eWide Pipe Size Compatibility\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1330\" data-end=\"1384\"\u003e\n\u003cli data-start=\"1330\" data-end=\"1384\" class=\"\"\u003e\n\u003cp data-start=\"1332\" data-end=\"1384\" class=\"\"\u003eSuitable for pipe diameters from \u003cstrong data-start=\"1365\" data-end=\"1383\"\u003e40mm to 4000mm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1386\" data-end=\"1426\" class=\"\"\u003e✅ \u003cstrong data-start=\"1388\" data-end=\"1424\"\u003eIdeal for Dirty \u0026amp; Slurry Liquids\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1427\" data-end=\"1539\"\u003e\n\u003cli data-start=\"1427\" data-end=\"1539\" class=\"\"\u003e\n\u003cp data-start=\"1429\" data-end=\"1539\" class=\"\"\u003eWorks with liquids containing at least \u003cstrong data-start=\"1468\" data-end=\"1490\"\u003e100 ppm reflectors\u003c\/strong\u003e, with \u003cstrong data-start=\"1497\" data-end=\"1538\"\u003e20% particles larger than 100 microns\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1541\" data-end=\"1587\" class=\"\"\u003e✅ \u003cstrong data-start=\"1543\" data-end=\"1585\"\u003eLow \u0026amp; High Flow Measurement Capability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1588\" data-end=\"1689\"\u003e\n\u003cli data-start=\"1588\" data-end=\"1689\" class=\"\"\u003e\n\u003cp data-start=\"1590\" data-end=\"1689\" class=\"\"\u003eMeasures flow velocities from \u003cstrong data-start=\"1620\" data-end=\"1645\"\u003e0.05 m\/s up to 12 m\/s\u003c\/strong\u003e, ensuring exceptional low flow sensitivity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1691\" data-end=\"1726\" class=\"\"\u003e✅ \u003cstrong data-start=\"1693\" data-end=\"1724\"\u003eHigh-Temperature Capability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1727\" data-end=\"1860\"\u003e\n\u003cli data-start=\"1727\" data-end=\"1793\" class=\"\"\u003e\n\u003cp data-start=\"1729\" data-end=\"1793\" class=\"\"\u003eStandard transducer: up to \u003cstrong data-start=\"1756\" data-end=\"1764\"\u003e85°C\u003c\/strong\u003e (short-term to \u003cstrong data-start=\"1780\" data-end=\"1789\"\u003e120°C\u003c\/strong\u003e).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1794\" data-end=\"1860\" class=\"\"\u003e\n\u003cp data-start=\"1796\" data-end=\"1860\" class=\"\"\u003eHigh-temp transducer: up to \u003cstrong data-start=\"1824\" data-end=\"1833\"\u003e200°C\u003c\/strong\u003e (short-term to \u003cstrong data-start=\"1849\" data-end=\"1858\"\u003e250°C\u003c\/strong\u003e).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1862\" data-end=\"1895\" class=\"\"\u003e✅ \u003cstrong data-start=\"1864\" data-end=\"1893\"\u003eNon-Invasive Installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1896\" data-end=\"1977\"\u003e\n\u003cli data-start=\"1896\" data-end=\"1977\" class=\"\"\u003e\n\u003cp data-start=\"1898\" data-end=\"1977\" class=\"\"\u003e\u003cstrong data-start=\"1898\" data-end=\"1922\"\u003eClamp-on transducers\u003c\/strong\u003e—no need to shut down the pipeline during installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1979\" data-end=\"2010\" class=\"\"\u003e✅ \u003cstrong data-start=\"1981\" data-end=\"2008\"\u003eUser-Friendly Operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2011\" data-end=\"2084\"\u003e\n\u003cli data-start=\"2011\" data-end=\"2084\" class=\"\"\u003e\n\u003cp data-start=\"2013\" data-end=\"2084\" class=\"\"\u003eIntuitive interface with \u003cstrong data-start=\"2038\" data-end=\"2057\"\u003e6-button keypad\u003c\/strong\u003e and clear \u003cstrong data-start=\"2068\" data-end=\"2083\"\u003eLCD display\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2086\" data-end=\"2126\" class=\"\"\u003e✅ \u003cstrong data-start=\"2088\" data-end=\"2124\"\u003eFlexible Outputs \u0026amp; Communication\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2127\" data-end=\"2199\"\u003e\n\u003cli data-start=\"2127\" data-end=\"2199\" class=\"\"\u003e\n\u003cp data-start=\"2129\" data-end=\"2199\" class=\"\"\u003eSupports \u003cstrong data-start=\"2138\" data-end=\"2148\"\u003e4-20mA\u003c\/strong\u003e analog and \u003cstrong data-start=\"2160\" data-end=\"2175\"\u003eOCT outputs\u003c\/strong\u003e for system integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2201\" data-end=\"2234\" class=\"\"\u003e✅ \u003cstrong data-start=\"2203\" data-end=\"2232\"\u003ePortable \u0026amp; Durable Design\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2235\" data-end=\"2328\"\u003e\n\u003cli data-start=\"2235\" data-end=\"2328\" class=\"\"\u003e\n\u003cp data-start=\"2237\" data-end=\"2328\" class=\"\"\u003eLightweight \u003cstrong data-start=\"2249\" data-end=\"2268\"\u003e3kg ABS housing\u003c\/strong\u003e with \u003cstrong data-start=\"2274\" data-end=\"2293\"\u003eIP65 protection\u003c\/strong\u003e, built for demanding environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2330\" data-end=\"2359\" class=\"\"\u003e✅ \u003cstrong data-start=\"2332\" data-end=\"2357\"\u003eExtended Battery Life\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2360\" data-end=\"2447\"\u003e\n\u003cli data-start=\"2360\" data-end=\"2447\" class=\"\"\u003e\n\u003cp data-start=\"2362\" data-end=\"2447\" class=\"\"\u003eBuilt-in \u003cstrong data-start=\"2371\" data-end=\"2416\"\u003erechargeable battery lasts up to 50 hours\u003c\/strong\u003e, ensuring long-term fieldwork.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2449\" data-end=\"2452\" class=\"\"\u003e\n\u003ch3 data-start=\"2454\" data-end=\"2478\" class=\"\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cul data-start=\"2480\" data-end=\"2688\"\u003e\n\u003cli data-start=\"2480\" data-end=\"2517\" class=\"\"\u003e\n\u003cp data-start=\"2482\" data-end=\"2517\" class=\"\"\u003eRaw sewage \u0026amp; wastewater treatment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2518\" data-end=\"2546\" class=\"\"\u003e\n\u003cp data-start=\"2520\" data-end=\"2546\" class=\"\"\u003eActivated sludge systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2547\" data-end=\"2578\" class=\"\"\u003e\n\u003cp data-start=\"2549\" data-end=\"2578\" class=\"\"\u003eGroundwater flow monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2579\" data-end=\"2606\" class=\"\"\u003e\n\u003cp data-start=\"2581\" data-end=\"2606\" class=\"\"\u003ePulp and paper slurries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2607\" data-end=\"2636\" class=\"\"\u003e\n\u003cp data-start=\"2609\" data-end=\"2636\" class=\"\"\u003eChemical process slurries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2637\" data-end=\"2657\" class=\"\"\u003e\n\u003cp data-start=\"2639\" data-end=\"2657\" class=\"\"\u003eDrainage systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2658\" data-end=\"2688\" class=\"\"\u003e\n\u003cp data-start=\"2660\" data-end=\"2688\" class=\"\"\u003eMining recirculation water\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2690\" data-end=\"2693\" class=\"\"\u003e\n\u003ch3 data-start=\"2695\" data-end=\"2723\" class=\"\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_16hzy_1\"\u003e\n\u003cdiv class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2725\" data-end=\"3980\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2725\" data-end=\"2797\"\u003e\n\u003ctr data-start=\"2725\" data-end=\"2797\"\u003e\n\u003cth data-start=\"2725\" data-end=\"2753\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2727\" data-end=\"2742\"\u003eTransmitter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"2753\" data-end=\"2797\" data-col-size=\"sm\"\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2871\" data-end=\"3980\"\u003e\n\u003ctr data-start=\"2871\" data-end=\"2944\"\u003e\n\u003ctd data-start=\"2871\" data-end=\"2900\" data-col-size=\"sm\"\u003eMeasurement Principle\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2900\" data-end=\"2944\"\u003eDoppler Ultrasonic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2945\" data-end=\"3018\"\u003e\n\u003ctd data-start=\"2945\" data-end=\"2974\" data-col-size=\"sm\"\u003eFlow Velocity Range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2974\" data-end=\"3018\"\u003e0.05 - 12 m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3019\" data-end=\"3092\"\u003e\n\u003ctd data-start=\"3019\" data-end=\"3048\" data-col-size=\"sm\"\u003eResolution\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3048\" data-end=\"3092\"\u003e0.25 mm\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3093\" data-end=\"3165\"\u003e\n\u003ctd data-start=\"3093\" data-end=\"3122\" data-col-size=\"sm\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd data-start=\"3122\" data-end=\"3165\" data-col-size=\"sm\"\u003e0.5% - 2.0% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3166\" data-end=\"3239\"\u003e\n\u003ctd data-start=\"3166\" data-end=\"3195\" data-col-size=\"sm\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd data-start=\"3195\" data-end=\"3239\" data-col-size=\"sm\"\u003e0.2% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3240\" data-end=\"3313\"\u003e\n\u003ctd data-start=\"3240\" data-end=\"3269\" data-col-size=\"sm\"\u003eResponse Time\u003c\/td\u003e\n\u003ctd data-start=\"3269\" data-end=\"3313\" data-col-size=\"sm\"\u003e2-60s (configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3314\" data-end=\"3387\"\u003e\n\u003ctd data-start=\"3314\" data-end=\"3343\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3343\" data-end=\"3387\"\u003e2-line LCD (8-digit rate or total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3388\" data-end=\"3462\"\u003e\n\u003ctd data-start=\"3388\" data-end=\"3417\" data-col-size=\"sm\"\u003eOutputs\u003c\/td\u003e\n\u003ctd data-start=\"3417\" data-end=\"3462\" data-col-size=\"sm\"\u003e4-20mA, OCT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3463\" data-end=\"3536\"\u003e\n\u003ctd data-start=\"3463\" data-end=\"3492\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3492\" data-end=\"3536\" data-col-size=\"sm\"\u003eAC 85-265V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3537\" data-end=\"3610\"\u003e\n\u003ctd data-start=\"3537\" data-end=\"3566\" data-col-size=\"sm\"\u003eBattery\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3566\" data-end=\"3610\"\u003eRechargeable, up to 50 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3611\" data-end=\"3684\"\u003e\n\u003ctd data-start=\"3611\" data-end=\"3640\" data-col-size=\"sm\"\u003eHousing Material\u003c\/td\u003e\n\u003ctd data-start=\"3640\" data-end=\"3684\" data-col-size=\"sm\"\u003eABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3685\" data-end=\"3758\"\u003e\n\u003ctd data-start=\"3685\" data-end=\"3714\" data-col-size=\"sm\"\u003eProtection Rating\u003c\/td\u003e\n\u003ctd data-start=\"3714\" data-end=\"3758\" data-col-size=\"sm\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3759\" data-end=\"3832\"\u003e\n\u003ctd data-start=\"3759\" data-end=\"3788\" data-col-size=\"sm\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3788\" data-end=\"3832\"\u003e-20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3833\" data-end=\"3906\"\u003e\n\u003ctd data-start=\"3833\" data-end=\"3862\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3862\" data-end=\"3906\"\u003e270 × 125 × 175 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3907\" data-end=\"3980\"\u003e\n\u003ctd data-start=\"3907\" data-end=\"3936\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"3936\" data-end=\"3980\" data-col-size=\"sm\"\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"sticky end-(--thread-content-margin) h-0 self-end select-none\"\u003e\n\u003cdiv class=\"absolute end-0 flex items-end\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cbutton class=\"bg-token-bg-primary hover:bg-token-bg-tertiary text-token-text-secondary my-1 rounded-sm p-1 transition-opacity group-[:not(:hover):not(:focus-within)]:pointer-events-none group-[:not(:hover):not(:focus-within)]:opacity-0\"\u003e\u003csvg width=\"24\" height=\"24\" viewbox=\"0 0 24 24\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"icon-md-heavy\"\u003e\u003cpath fill-rule=\"evenodd\" clip-rule=\"evenodd\" d=\"M7 5C7 3.34315 8.34315 2 10 2H19C20.6569 2 22 3.34315 22 5V14C22 15.6569 20.6569 17 19 17H17V19C17 20.6569 15.6569 22 14 22H5C3.34315 22 2 20.6569 2 19V10C2 8.34315 3.34315 7 5 7H7V5ZM9 7H14C15.6569 7 17 8.34315 17 10V15H19C19.5523 15 20 14.5523 20 14V5C20 4.44772 19.5523 4 19 4H10C9.44772 4 9 4.44772 9 5V7ZM5 9C4.44772 9 4 9.44772 4 10V19C4 19.5523 4.44772 20 5 20H14C14.5523 20 15 19.5523 15 19V10C15 9.44772 14.5523 9 14 9H5Z\" fill=\"currentColor\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/button\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"_tableContainer_16hzy_1\"\u003e\n\u003cdiv class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3982\" data-end=\"4696\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3982\" data-end=\"4055\"\u003e\n\u003ctr data-start=\"3982\" data-end=\"4055\"\u003e\n\u003cth data-start=\"3982\" data-end=\"4011\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3984\" data-end=\"3998\"\u003eTransducer\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"4011\" data-end=\"4055\" data-col-size=\"md\"\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"4129\" data-end=\"4696\"\u003e\n\u003ctr data-start=\"4129\" data-end=\"4202\"\u003e\n\u003ctd data-start=\"4129\" data-end=\"4158\" data-col-size=\"sm\"\u003eType\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4158\" data-end=\"4202\"\u003eClamp-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4203\" data-end=\"4276\"\u003e\n\u003ctd data-start=\"4203\" data-end=\"4232\" data-col-size=\"sm\"\u003eProtection Rating\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4232\" data-end=\"4276\"\u003eIP65 \/ IP67 \/ IP68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4277\" data-end=\"4400\"\u003e\n\u003ctd data-start=\"4277\" data-end=\"4306\" data-col-size=\"sm\"\u003eLiquid Temp Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4306\" data-end=\"4400\"\u003eStandard: -35°C to 85°C (120°C short-term)\u003cbr\u003eHigh Temp: -35°C to 200°C (250°C short-term)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4401\" data-end=\"4474\"\u003e\n\u003ctd data-start=\"4401\" data-end=\"4430\" data-col-size=\"sm\"\u003ePipe Diameter Range\u003c\/td\u003e\n\u003ctd data-start=\"4430\" data-end=\"4474\" data-col-size=\"md\"\u003e40 - 4000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4475\" data-end=\"4548\"\u003e\n\u003ctd data-start=\"4475\" data-end=\"4504\" data-col-size=\"sm\"\u003eTransducer Size\u003c\/td\u003e\n\u003ctd data-start=\"4504\" data-end=\"4548\" data-col-size=\"md\"\u003e60 × 34 × 33 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4549\" data-end=\"4622\"\u003e\n\u003ctd data-start=\"4549\" data-end=\"4578\" data-col-size=\"sm\"\u003eMaterial\u003c\/td\u003e\n\u003ctd data-start=\"4578\" data-end=\"4622\" data-col-size=\"md\"\u003eAluminum (Standard), PEEK (High Temp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4623\" data-end=\"4696\"\u003e\n\u003ctd data-start=\"4623\" data-end=\"4652\" data-col-size=\"sm\"\u003eCable Length\u003c\/td\u003e\n\u003ctd data-start=\"4652\" data-end=\"4696\" data-col-size=\"md\"\u003eStandard 5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"sticky end-(--thread-content-margin) h-0 self-end select-none\"\u003e\n\u003cdiv class=\"absolute end-0 flex items-end\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cbutton class=\"bg-token-bg-primary hover:bg-token-bg-tertiary text-token-text-secondary my-1 rounded-sm p-1 transition-opacity group-[:not(:hover):not(:focus-within)]:pointer-events-none group-[:not(:hover):not(:focus-within)]:opacity-0\"\u003e\u003csvg width=\"24\" height=\"24\" viewbox=\"0 0 24 24\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"icon-md-heavy\"\u003e\u003cpath fill-rule=\"evenodd\" clip-rule=\"evenodd\" d=\"M7 5C7 3.34315 8.34315 2 10 2H19C20.6569 2 22 3.34315 22 5V14C22 15.6569 20.6569 17 19 17H17V19C17 20.6569 15.6569 22 14 22H5C3.34315 22 2 20.6569 2 19V10C2 8.34315 3.34315 7 5 7H7V5ZM9 7H14C15.6569 7 17 8.34315 17 10V15H19C19.5523 15 20 14.5523 20 14V5C20 4.44772 19.5523 4 19 4H10C9.44772 4 9 4.44772 9 5V7ZM5 9C4.44772 9 4 9.44772 4 10V19C4 19.5523 4.44772 20 5 20H14C14.5523 20 15 19.5523 15 19V10C15 9.44772 14.5523 9 14 9H5Z\" fill=\"currentColor\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/button\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"absolute end-0 flex items-end\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"absolute end-0 flex items-end\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003eDownloads\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"absolute end-0 flex items-end\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003eData Sheet \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/pl148429548-duf901_ep_doppler_portable_ultrasonic_flow_meter_for_waste_water_treatment_plant.webp?v=1747126490\" target=\"_blank\" rel=\"noopener\"\u003eLink\u003c\/a\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Inspection Tool Specialists","offers":[{"title":"Default Title","offer_id":48427456987365,"sku":"DUF901-EP","price":16230.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pl148429547-duf901_ep_doppler_portable_ultrasonic_flow_meter_for_waste_water_treatment_plant.webp?v=1771409900"},{"product_id":"insertion-type-ultrasonic-flowmeter-st501","title":"Insertion Ultrasonic Flow Meter ST501","description":"\u003ch3 data-start=\"738\" data-end=\"766\"\u003e\u003cstrong data-start=\"742\" data-end=\"766\"\u003eProduct Description:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"768\" data-end=\"1168\"\u003e\u003cstrong data-start=\"768\" data-end=\"809\"\u003eAccurate. Reliable. Industrial-Grade.\u003c\/strong\u003e\u003cbr data-start=\"809\" data-end=\"812\"\u003eThe \u003cstrong data-start=\"816\" data-end=\"861\"\u003eST501 Insertion Type Ultrasonic Flowmeter\u003c\/strong\u003e leverages advanced \u003cstrong data-start=\"881\" data-end=\"914\"\u003eTransit-Time (TVT) technology\u003c\/strong\u003e to deliver precise flow measurement across a wide range of liquids and pipe sizes (1\"–48\"). Designed for easy installation and long-term reliability, this flowmeter is ideal for industrial environments requiring real-time, non-intrusive flow monitoring.\u003c\/p\u003e\n\u003cp data-start=\"1170\" data-end=\"1431\"\u003eCrafted with high-grade materials and housed in a robust metal case, the ST501 is built for \u003cstrong data-start=\"1262\" data-end=\"1284\"\u003eharsh environments\u003c\/strong\u003e. Its \u003cstrong data-start=\"1290\" data-end=\"1315\"\u003eIP68-rated transducer\u003c\/strong\u003e can withstand immersion and high humidity conditions, making it an excellent choice for rugged industrial settings.\u003c\/p\u003e\n\u003chr data-start=\"1433\" data-end=\"1436\"\u003e\n\u003ch3 data-start=\"1438\" data-end=\"1470\"\u003e\u003cstrong data-start=\"1442\" data-end=\"1470\"\u003eKey Features \u0026amp; Benefits:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1472\" data-end=\"2442\"\u003e\n\u003cli data-start=\"1472\" data-end=\"1632\"\u003e\n\u003cp data-start=\"1474\" data-end=\"1632\"\u003e\u003cstrong data-start=\"1474\" data-end=\"1504\"\u003eHigh Accuracy Measurement:\u003c\/strong\u003e\u003cbr data-start=\"1504\" data-end=\"1507\"\u003eTransit-Time and TVT technology ensure consistent and precise flow readings, even in turbulent or variable flow conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1634\" data-end=\"1768\"\u003e\n\u003cp data-start=\"1636\" data-end=\"1768\"\u003e\u003cstrong data-start=\"1636\" data-end=\"1667\"\u003eNon-Intrusive Installation:\u003c\/strong\u003e\u003cbr data-start=\"1667\" data-end=\"1670\"\u003eInsertion-style transducer minimizes pressure loss by preserving the integrity of the pipe wall.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1770\" data-end=\"1908\"\u003e\n\u003cp data-start=\"1772\" data-end=\"1908\"\u003e\u003cstrong data-start=\"1772\" data-end=\"1798\"\u003eVersatile Application:\u003c\/strong\u003e\u003cbr data-start=\"1798\" data-end=\"1801\"\u003eSuitable for conductive liquids, slurries, and highly corrosive fluids such as acids, alkalis, and salts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1910\" data-end=\"2079\"\u003e\n\u003cp data-start=\"1912\" data-end=\"2079\"\u003e\u003cstrong data-start=\"1912\" data-end=\"1940\"\u003eUser-Friendly Interface:\u003c\/strong\u003e\u003cbr data-start=\"1940\" data-end=\"1943\"\u003eBuilt-in keypad, intuitive menu navigation, and a clear LCD screen with alarm functionality make setup and monitoring straightforward.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2081\" data-end=\"2199\"\u003e\n\u003cp data-start=\"2083\" data-end=\"2199\"\u003e\u003cstrong data-start=\"2083\" data-end=\"2109\"\u003eAdvanced Data Logging:\u003c\/strong\u003e\u003cbr data-start=\"2109\" data-end=\"2112\"\u003eStore and analyze historical flow data to optimize system performance and efficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2201\" data-end=\"2328\"\u003e\n\u003cp data-start=\"2203\" data-end=\"2328\"\u003e\u003cstrong data-start=\"2203\" data-end=\"2231\"\u003eWide Pipe Compatibility:\u003c\/strong\u003e\u003cbr data-start=\"2231\" data-end=\"2234\"\u003eWorks with pipe diameters from 1\" (25mm) up to 48\" (1200mm), covering most industrial needs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2330\" data-end=\"2442\"\u003e\n\u003cp data-start=\"2332\" data-end=\"2442\"\u003e\u003cstrong data-start=\"2332\" data-end=\"2353\"\u003eRugged \u0026amp; Durable:\u003c\/strong\u003e\u003cbr data-start=\"2353\" data-end=\"2356\"\u003eIndustrial-grade components ensure long-lasting performance in demanding conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2444\" data-end=\"2447\"\u003e\n\u003ch3 data-start=\"2449\" data-end=\"2477\"\u003e\u003cstrong data-start=\"2453\" data-end=\"2477\"\u003eTechnology Overview:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"2479\" data-end=\"2756\"\u003e\u003cstrong data-start=\"2479\" data-end=\"2519\"\u003eTVT (Transit-Time Vortex) Technology\u003c\/strong\u003e\u003cbr data-start=\"2519\" data-end=\"2522\"\u003eThis innovative hybrid approach combines transit-time ultrasonic methods with vortex shedding detection to enhance measurement accuracy across various flow regimes—especially useful in applications with fluctuating or turbulent flows.\u003c\/p\u003e\n\u003chr data-start=\"2758\" data-end=\"2761\"\u003e\n\u003ch3 data-start=\"2763\" data-end=\"2788\"\u003e\u003cstrong data-start=\"2767\" data-end=\"2788\"\u003eIdeal For Use In:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2790\" data-end=\"3013\"\u003e\n\u003cli data-start=\"2790\" data-end=\"2831\"\u003e\n\u003cp data-start=\"2792\" data-end=\"2831\"\u003eChemical and Petrochemical Industries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2832\" data-end=\"2875\"\u003e\n\u003cp data-start=\"2834\" data-end=\"2875\"\u003eWater Treatment and Municipal Utilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2876\" data-end=\"2904\"\u003e\n\u003cp data-start=\"2878\" data-end=\"2904\"\u003eEnvironmental Monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2905\" data-end=\"2937\"\u003e\n\u003cp data-start=\"2907\" data-end=\"2937\"\u003eFood and Beverage Processing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2938\" data-end=\"2979\"\u003e\n\u003cp data-start=\"2940\" data-end=\"2979\"\u003ePharmaceutical and Textile Industries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2980\" data-end=\"3013\"\u003e\n\u003cp data-start=\"2982\" data-end=\"3013\"\u003eMetallurgy and Paper Production\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003ePerformance specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVelocity range\u003c\/td\u003e\n\u003ctd\u003e0 ~ ±16ft\/s (0 ~ ±5m\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe size\u003c\/td\u003e\n\u003ctd\u003eClamp-on: 1’’~48’’ (25mm~1200mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluid\u003c\/td\u003e\n\u003ctd\u003eWater, Sea water, Oil, Alcohol...\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe material\u003c\/td\u003e\n\u003ctd\u003ePVC, Carbon Steel, Stainless Steel...\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eFunction specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eOptional Outputs\u003c\/td\u003e\n\u003ctd\u003eOCT Pulse output: 0~5000Hz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog output: 4~20mA, max load 750Ω.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication interface\u003c\/td\u003e\n\u003ctd\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e24V DC\/1A@ max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003ctd\u003e16(4×4) key with tactile action\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e20×2 lattice alphanumeric, back lit LCD.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eTransmitter: 32℉~140℉ (0℃~60℃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer: -40℉~176℉ (-40℃~80℃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003eUp to 99% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003ePhysical specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter\u003c\/td\u003e\n\u003ctd\u003eAluminum alloy, IP65.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eEncapsulated design, IP68.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer cable\u003c\/td\u003e\n\u003ctd\u003eStandard cable length: 33ft (10m).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTransmitter: approximately 0.7kg;\u003c\/p\u003e\n\u003cp\u003eTransducer: approximately 0.4kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch6\u003eDownloads\u003c\/h6\u003e\n\u003cp\u003eData Sheet \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/ST501_Ultrasonic_Flow_Meter_Technical_Datasheet.pdf?v=1770109657\"\u003eLink\u003c\/a\u003e\u003c\/p\u003e","brand":"Flo Instru","offers":[{"title":"Default Title","offer_id":48427457216741,"sku":"ST501","price":3460.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pl171438150-st501_adaptive_signal_processing_best_insertion_ultrasonic_flow_meter.webp?v=1771409934"},{"product_id":"clamp-on-ultrasonic-flowmeter-st502","title":"Clamp-On Ultrasonic Flow Meter ST502","description":"\u003ch3 data-start=\"734\" data-end=\"762\"\u003e\u003cstrong data-start=\"738\" data-end=\"762\"\u003eProduct Description:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"764\" data-end=\"1204\"\u003e\u003cstrong data-start=\"764\" data-end=\"821\"\u003eNon-Invasive. High-Accuracy. Industrially Engineered.\u003c\/strong\u003e\u003cbr data-start=\"821\" data-end=\"824\"\u003eThe \u003cstrong data-start=\"828\" data-end=\"867\"\u003eST502 Clamp-On Ultrasonic Flowmeter\u003c\/strong\u003e offers precision flow measurement using cutting-edge \u003cstrong data-start=\"921\" data-end=\"961\"\u003eTransit-Time Vortex (TVT) technology\u003c\/strong\u003e, designed for a wide range of pipe sizes and liquid types. With a \u003cstrong data-start=\"1028\" data-end=\"1051\"\u003eclamp-on transducer\u003c\/strong\u003e that requires no pipe modification or contact with the liquid, this flowmeter ensures zero contamination, no pressure loss, and simplified installation.\u003c\/p\u003e\n\u003cp data-start=\"1206\" data-end=\"1574\"\u003eManufactured with durable \u003cstrong data-start=\"1232\" data-end=\"1250\"\u003ealuminum alloy\u003c\/strong\u003e and \u003cstrong data-start=\"1255\" data-end=\"1283\"\u003eCNC precision processing\u003c\/strong\u003e, the ST502 also features a \u003cstrong data-start=\"1311\" data-end=\"1351\"\u003escrewless magnetic open-cover design\u003c\/strong\u003e for effortless access—ideal for technicians looking to minimize setup time. With an IP68-rated sensor and a wide diameter compatibility (1\"–200\"), it’s the go-to solution for versatile, clean, and accurate flow monitoring.\u003c\/p\u003e\n\u003chr data-start=\"1576\" data-end=\"1579\"\u003e\n\u003ch3 data-start=\"1581\" data-end=\"1613\"\u003e\u003cstrong data-start=\"1585\" data-end=\"1613\"\u003eKey Features \u0026amp; Benefits:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1615\" data-end=\"2616\"\u003e\n\u003cli data-start=\"1615\" data-end=\"1745\"\u003e\n\u003cp data-start=\"1617\" data-end=\"1745\"\u003e\u003cstrong data-start=\"1617\" data-end=\"1637\"\u003eClamp-On Design:\u003c\/strong\u003e\u003cbr data-start=\"1637\" data-end=\"1640\"\u003eNo need to cut pipes or disrupt flow. Installs externally—ideal for retrofit or hard-to-access systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1747\" data-end=\"1889\"\u003e\n\u003cp data-start=\"1749\" data-end=\"1889\"\u003e\u003cstrong data-start=\"1749\" data-end=\"1777\"\u003eAdvanced TVT Technology:\u003c\/strong\u003e\u003cbr data-start=\"1777\" data-end=\"1780\"\u003eCombines transit-time and vortex shedding for ultra-precise measurement, even in turbulent flow conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1891\" data-end=\"2008\"\u003e\n\u003cp data-start=\"1893\" data-end=\"2008\"\u003e\u003cstrong data-start=\"1893\" data-end=\"1914\"\u003eNo Fluid Contact:\u003c\/strong\u003e\u003cbr data-start=\"1914\" data-end=\"1917\"\u003ePrevents contamination, corrosion, or leakage—perfect for sensitive or hazardous liquids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2010\" data-end=\"2131\"\u003e\n\u003cp data-start=\"2012\" data-end=\"2131\"\u003e\u003cstrong data-start=\"2012\" data-end=\"2039\"\u003eIndustrial-Grade Build:\u003c\/strong\u003e\u003cbr data-start=\"2039\" data-end=\"2042\"\u003eMade from high-strength aluminum alloy with CNC machining for durability and precision.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2133\" data-end=\"2249\"\u003e\n\u003cp data-start=\"2135\" data-end=\"2249\"\u003e\u003cstrong data-start=\"2135\" data-end=\"2161\"\u003eMagnetic Cover System:\u003c\/strong\u003e\u003cbr data-start=\"2161\" data-end=\"2164\"\u003ePatented screwless, side-opening design allows one-second access—no tools required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2251\" data-end=\"2382\"\u003e\n\u003cp data-start=\"2253\" data-end=\"2382\"\u003e\u003cstrong data-start=\"2253\" data-end=\"2274\"\u003eEasy Programming:\u003c\/strong\u003e\u003cbr data-start=\"2274\" data-end=\"2277\"\u003eBuilt-in keypad with intuitive menu for setting pipe size, material, fluid type, and measurement units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2384\" data-end=\"2516\"\u003e\n\u003cp data-start=\"2386\" data-end=\"2516\"\u003e\u003cstrong data-start=\"2386\" data-end=\"2412\"\u003eBuilt-In Data Logging:\u003c\/strong\u003e\u003cbr data-start=\"2412\" data-end=\"2415\"\u003eIntegrated 2G SD card allows for flow data storage and historical analysis for system optimization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2518\" data-end=\"2616\"\u003e\n\u003cp data-start=\"2520\" data-end=\"2616\"\u003e\u003cstrong data-start=\"2520\" data-end=\"2548\"\u003eWide Pipe Compatibility:\u003c\/strong\u003e\u003cbr data-start=\"2548\" data-end=\"2551\"\u003eFits pipes ranging from 1\" (25mm) to 200\" (5000mm) in diameter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2618\" data-end=\"2621\"\u003e\n\u003ch3 data-start=\"2623\" data-end=\"2651\"\u003e\u003cstrong data-start=\"2627\" data-end=\"2651\"\u003eTechnology Overview:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"2653\" data-end=\"2903\"\u003e\u003cstrong data-start=\"2653\" data-end=\"2693\"\u003eTVT (Transit-Time Vortex) Technology\u003c\/strong\u003e\u003cbr data-start=\"2693\" data-end=\"2696\"\u003eTVT integrates transit-time ultrasonic methods with vortex shedding analysis to significantly improve accuracy across varying flow conditions—especially when transitioning between laminar and turbulent flow.\u003c\/p\u003e\n\u003chr data-start=\"2905\" data-end=\"2908\"\u003e\n\u003ch3 data-start=\"2910\" data-end=\"2935\"\u003e\u003cstrong data-start=\"2914\" data-end=\"2935\"\u003eIdeal For Use In:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2937\" data-end=\"3131\"\u003e\n\u003cli data-start=\"2937\" data-end=\"2977\"\u003e\n\u003cp data-start=\"2939\" data-end=\"2977\"\u003eIndustrial \u0026amp; Municipal Water Systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2978\" data-end=\"3008\"\u003e\n\u003cp data-start=\"2980\" data-end=\"3008\"\u003eFood \u0026amp; Beverage Processing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3009\" data-end=\"3047\"\u003e\n\u003cp data-start=\"3011\" data-end=\"3047\"\u003eChemical and Pharmaceutical Plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3048\" data-end=\"3090\"\u003e\n\u003cp data-start=\"3050\" data-end=\"3090\"\u003eOil \u0026amp; Gas and Petrochemical Industries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3091\" data-end=\"3131\"\u003e\n\u003cp data-start=\"3093\" data-end=\"3131\"\u003eEnvironmental Monitoring and Utilities\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp align=\"justify\"\u003ePERFORMANCE SPECIFICATIONS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eVelocity range\u003c\/td\u003e\n\u003ctd\u003e±0.1 ~\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" name=\"OLE_LINK2\" target=\"_blank\"\u003e\u003c\/a\u003e±40ft\/s (±0.03 ~ ±12m\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5% of measured value (for ±1.5ft\/s~±40ft\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e0.15% of measured value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003ePipe size\u003c\/td\u003e\n\u003ctd\u003e1\" to 200\" (25mm to 5000mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eFUNCTION SPECIFICATIONS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp align=\"justify\"\u003eAnalog output: 4~20mA, maximum 750Ω.\u003c\/p\u003e\n\u003cp align=\"justify\"\u003ePulse output: 0~9999Hz, OCT output, (adjustable)\u003c\/p\u003e\n\u003cp align=\"justify\"\u003eRelay output: the highest 1Hz, (1A@125VAC or 2A@30VDC)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRS485 Communication Interface, Support Modbus Protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD Card\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMax record: 2GB, working more than 1000 days (sample frequency 5 second )\u003cspan\u003e \u003c\/span\u003e\u003ca rel=\"nofollow\" name=\"OLE_LINK1\" target=\"_blank\"\u003e\u003c\/a\u003eStorage time interval: 1~86400s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e16 light tactile keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e40 character, 2 line (20×2) lattice alphanumeric, backlit LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTransmitter: -40℉~140℉ (-40℃~60℃)\u003cbr\u003eTransducer: -40℉~248℉ (-40℃~120℃) Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUp to 99% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003ePHYSICAL SPECIFICATIONS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDie-cast aluminum, IP65, CNC machined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp align=\"justify\"\u003e\u003ca rel=\"nofollow\" name=\"OLE_LINK4\" target=\"_blank\"\u003e\u003c\/a\u003eEncapsulated design, protection grade IP68\u003c\/p\u003e\n\u003cp align=\"justify\"\u003eThe standard length of cable: 10m\u003c\/p\u003e\n\u003cp align=\"justify\"\u003eMaterial: Aluminium alloy+PEI\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTransmitter: 1kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/ST502_Ultrasonic_Flow_Meter_Technical_Datasheet.pdf?v=1770109657\"\u003eDownloads\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eData Sheet \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/ST502_Ultrasonic_Flow_Meter_Technical_Datasheet.pdf?v=1770109657\"\u003eLink\u003c\/a\u003e\u003c\/p\u003e","brand":"Flo Instru","offers":[{"title":"Default Title","offer_id":48427457282277,"sku":"ST502","price":7110.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pl169573308-st502_4_20ma_output_ultrasonic_flowmeter.webp?v=1771409939"},{"product_id":"multi-path-ultrasonic-flowmeter-mu801-plus","title":"Multi-Path Ultrasonic Flow Meter MU801 Plus","description":"\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMU801 Plus Multi-Path Ultrasonic Flowmeter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eYour reliable high precision flow measurement solutions!\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe MU801 Plus ultrasonic flowmeter is a high-precision instrument with ultra-high accuracy, linearity, and repeatability, which meets strict measurement requirements.\u003c\/p\u003e\n\u003cp\u003eIts measurement accuracy is high, and it is almost free from the influence of various parameters and the interference of the measuring medium. It is an ideal solution for flow measurement of strong corrosive, non-conductive, radiant and flammable and explosive media.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMain Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupport multi-path\u003c\/li\u003e\n\u003cli\u003eHigh Accuracy: ±0.5%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eVirtually all commonly used liquids. Liquids with small amounts of small particles can also be measured. Examples are hot\/cold water, sea water, waste water, chemical liquids, oil, crude oil, alcohol, beer, etc.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003ePERFORMANCE SPECIFICATIONS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eVelocity range\u003c\/td\u003e\n\u003ctd\u003e0.01~12m\/s (0.03~40ft\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5% of measured value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.1%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003ePipe size\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e25mm~5000mm (1\"~200\")\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eInsertion type:100mm~5000mm(4\"~200\")\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eFUNCTION SPECIFICATIONS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eAnalog output: 4-20mA \u0026amp; Analog input, max load: 600Ω\u003c\/p\u003e\n\u003cp\u003ePulse output: 0~9999Hz, OCT output (adjustable)\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e\u003ca rel=\"nofollow\" name=\"OLE_LINK2\" target=\"_blank\"\u003e\u003c\/a\u003eRelay output:\u003cspan\u003e \u003c\/span\u003eSPST, max 1Hz, (1A@125V AC or 2A@30V DC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication:\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRS485, support Modbus communication protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e24~36V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFour Touch keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3.5\" TFT LCD 480*320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eTransmitter: -40℃~60℃ (-40℉~+140℉)\u003c\/p\u003e\n\u003cp\u003eClamp-on transducer: -40℃~+120℃ (-40℉~+248℉)\u003c\/p\u003e\n\u003cp\u003eInsertion transducer: -40℃~+80℃ (-40℉~+176℉)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUp to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApply to water quality\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eTurbidity range: 0~12000NTU\u003c\/p\u003e\n\u003cp\u003ePH range: 6~9\u003c\/p\u003e\n\u003cp\u003eSuitable for with bubbles and no bubbles\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelf-detective function and Error indications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eSeparately displays instantaneous and totalizer flow rates, unit of the measurement is 8-digit display.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003ePHYSICAL SPECIFICATIONS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDie-cast aluminum, IP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eEncapsulated design, double-shielded transducer cable.\u003c\/p\u003e\n\u003cp\u003eThe standard length of cable: 33ft (10m); Protection grade: IP68\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eTransmitter: approximately 3.3 lb (1.5KG)\u003c\/p\u003e\n\u003cp\u003eTransducer: approximately 3.3 lb (1.5KG)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Flo Instru","offers":[{"title":"Default Title","offer_id":48427457315045,"sku":"MU801 Plus","price":13290.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pl145145533-mu801_plus_ultrasonic_flowmeter_for_multi_path_measurement.webp?v=1771409945"},{"product_id":"portable-ultrasonic-flow-meter-ph301","title":"Portable Ultrasonic Flow Meter PH301","description":"\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePH301 Portable Ultrasonic Flow Meters\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFlo-Instruments' PH301 is a highly accurate and non-invasive portable ultrasonic flow meter for liquid flow measurement. PH301uses the most reliable digital signal processing technology, transmitting flow measurement for a wide range of liquid and pipe size with high accuracy and reliability.\u003c\/p\u003e\n\u003cp\u003ePH301 is the ideal tool for testing and validating flow. The battery operated portable meter utilizes clamp-on transducers to measure flow through the pipe wall. One transducer sets are provided for optimal performance with pipes ranging from 1” to 200” in diameter, and it works with most commonly-used and other special pipe materials.\u003c\/p\u003e\n\u003cp\u003eClean and big screen makes users easier to enter the pipe diameter, wall thickness and pipe material in the meter. PH301 can be powered for up to 12 hours using the built-in and rechargeable battery. Monitoring flow over time is made easy with the built-in data logger. The 2G SD card can max 512 files with intervals ranging from 1 seconds to 86400s apart. These data can be downloaded to your PC via a USB flash drive.\u003c\/p\u003e\n\u003cp\u003ePH301 is provided with high protection level for IP65 transmitter and IP68 transducer and supports samely bidirectional measurement with totalizing function. In addition, it's optional magnetic guide rail or mounting accessory by pipe straps.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for Monitoring \u0026amp; Measuring Flow\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eClamp-on transducers allow for quick installation with no shutdown, no drilling and no pressure drop. Each meter is provided with a built-in SD card making it an ideal solution for monitoring flow over time. Fully equipped carrying case includes a set of complete measurement tools and the rechargeable internal battery makes it the ideal go-anywhere flowmeter.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWorks with Multi Pipe Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is designed to work with many different pipe materials including PVC, carbon steel, stainless steel, copper, PE, HDPE, ductile iron, aluminum, asbestos and fiber glass-epoxy.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimple to Set Up and Use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePH301 is easily configured through 4.3 inch TFT colorful screen and 22 touch keys. Enter a few key parameters and the display screen will display the correct transducer separation distance.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAlphanumeric and Flow Curve Display Completes the Picture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA large, multifunction LCD presents measured data in both alphanumeric and graphic forms. Standard alphanumeric functions include flow velocity, flow, and totalized flow in either English (U.S.) or metric units. In graphic mode, the LCD shows both real time and logged data, which is very useful for reviewing data and observing trends while on the site.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePrinciple\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIntroduction to TVT\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTVT(Transit-Time Vortex) technology represents a cutting-edge approach to ultrasonic flow measurement, combining the principles of transit-time ultrasonics with the capability to harness the vortex shedding phenomenon, delivering unparalleled accuracy and versatility in ultrasonic flow meters. This innovative integration technology enhances the accuracy, versatility, and performance of ultrasonic flow meters, making them well-suited for a wide range of applications across various industries and is a valuable solution for industries requiring precise flow measurements in varying flow conditions.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnhanced Accuracy in Turbulent Flows:\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTVT technology excels in applications where fluid flow conditions vary between laminar and turbulent. The incorporation of vortex shedding data enhances accuracy in challenging flow environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVersatility in Fluid Types:\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTVT technology is versatile and suitable for a wide range of fluid types, including liquids with varying viscosities and densities.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"PH301 Handheld Ultrasonic Flow Meter For Subsurface Water Measurement 0\" src=\"https:\/\/www.flo-instruments.com\/photo\/flo-instruments\/editor\/20240408105527_69680.png\" class=\"lazyi\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable align=\"left\" border=\"1\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003ePERFORMANCE SPECIFICATIONS\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eVelocity range\u003c\/td\u003e\n\u003ctd\u003e±0.03 ~ ±40 ft\/s (±0.01 ~ ±12 m\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5% of measured value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e0.15%.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e±0.5%.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003ePipe Size\u003c\/td\u003e\n\u003ctd\u003e1ʺ ~ 200ʺ (25mm~5000mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eFUNCTION SPECIFICATIONS\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAnalog output: 4~20mA, Max 750 Ω.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD card\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eStorage: 2GB;\u003cbr\u003eMax: 512 files;\u003cbr\u003eInterval: 1~86400s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRechargeable Lithium Battery Power\u003cbr\u003e(continuous operation of main battery 12 hours ).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e22 touch keys.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e4.3 inch TFT screen, backlight LCD.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTransmitter: 32℉~140℉ (0℃~60℃)\u003cbr\u003eTransducer: -40℉~248℉ (-40℃~120℃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 99% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003ePHYSICAL SPECIFICATIONS\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTransmitter\u003c\/td\u003e\n\u003ctd\u003eNEMA13 (IP54)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eEncapsulated design, IP68;\u003cbr\u003eStandard cable length: 5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eTransmitter: approximately 1.0kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Flo Instru","offers":[{"title":"Default Title","offer_id":48427457380581,"sku":"PH301","price":9840.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pl169314404-ph301_handheld_ultrasonic_flow_meter_for_subsurface_water_measurement.webp?v=1771409952"},{"product_id":"ultrasonic-flowmeter-clamp-on-tm601","title":"Ultrasonic Flow Meter TM601","description":"\u003ch3 data-start=\"696\" data-end=\"724\"\u003e\u003cstrong data-start=\"700\" data-end=\"724\"\u003eProduct Description:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"726\" data-end=\"1157\"\u003e\u003cstrong data-start=\"726\" data-end=\"795\"\u003eUltrafast Installation. Zero Downtime. Precision Flow Monitoring.\u003c\/strong\u003e\u003cbr data-start=\"795\" data-end=\"798\"\u003eThe \u003cstrong data-start=\"802\" data-end=\"841\"\u003eTM601 Clamp-On Ultrasonic Flowmeter\u003c\/strong\u003e is purpose-built for the \u003cstrong data-start=\"867\" data-end=\"899\"\u003eultrasonic cleaning industry\u003c\/strong\u003e, delivering \u003cstrong data-start=\"912\" data-end=\"947\"\u003ehigh-precision flow measurement\u003c\/strong\u003e with \u003cstrong data-start=\"953\" data-end=\"986\"\u003eno interruption to production\u003c\/strong\u003e. With a compact, lightweight design and simple clamp-on mounting, installation is completed in just \u003cstrong data-start=\"1087\" data-end=\"1101\"\u003eone minute\u003c\/strong\u003e, without modifying your pipeline or halting operations.\u003c\/p\u003e\n\u003cp data-start=\"1159\" data-end=\"1382\"\u003eThe TM601 features a bright \u003cstrong data-start=\"1187\" data-end=\"1215\"\u003eOLED display (128×64 px)\u003c\/strong\u003e for easy readability even in low-light conditions, and is compatible with a broad range of pipe materials—including stainless steel, carbon steel, PVC, PPR, and more.\u003c\/p\u003e\n\u003chr data-start=\"1384\" data-end=\"1387\"\u003e\n\u003ch3 data-start=\"1389\" data-end=\"1421\"\u003e\u003cstrong data-start=\"1393\" data-end=\"1421\"\u003eKey Features \u0026amp; Benefits:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1423\" data-end=\"2199\"\u003e\n\u003cli data-start=\"1423\" data-end=\"1549\"\u003e\n\u003cp data-start=\"1425\" data-end=\"1549\"\u003e\u003cstrong data-start=\"1425\" data-end=\"1451\"\u003e1-Minute Installation:\u003c\/strong\u003e\u003cbr data-start=\"1451\" data-end=\"1454\"\u003eGet up and running fast—no system shutdowns, pipe cutting, or process interruptions required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1551\" data-end=\"1670\"\u003e\n\u003cp data-start=\"1553\" data-end=\"1670\"\u003e\u003cstrong data-start=\"1553\" data-end=\"1579\"\u003eNo Pipe Modifications:\u003c\/strong\u003e\u003cbr data-start=\"1579\" data-end=\"1582\"\u003eClamp-on design enables external installation with zero pressure loss or leakage risk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1672\" data-end=\"1796\"\u003e\n\u003cp data-start=\"1674\" data-end=\"1796\"\u003e\u003cstrong data-start=\"1674\" data-end=\"1699\"\u003eTool-Free Simplicity:\u003c\/strong\u003e\u003cbr data-start=\"1699\" data-end=\"1702\"\u003eOnly a Phillips-head screwdriver is needed—no special tools or technical expertise required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1798\" data-end=\"1900\"\u003e\n\u003cp data-start=\"1800\" data-end=\"1900\"\u003e\u003cstrong data-start=\"1800\" data-end=\"1817\"\u003eOLED Display:\u003c\/strong\u003e\u003cbr data-start=\"1817\" data-end=\"1820\"\u003eHigh-contrast screen ensures clear readings in dark or dimly lit environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1902\" data-end=\"2023\"\u003e\n\u003cp data-start=\"1904\" data-end=\"2023\"\u003e\u003cstrong data-start=\"1904\" data-end=\"1932\"\u003eWide Pipe Compatibility:\u003c\/strong\u003e\u003cbr data-start=\"1932\" data-end=\"1935\"\u003eWorks with stainless steel, carbon steel, copper, PVC, PVDF, HDPE, PPR, PPH, and more.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2025\" data-end=\"2199\"\u003e\n\u003cp data-start=\"2027\" data-end=\"2199\"\u003e\u003cstrong data-start=\"2027\" data-end=\"2061\"\u003eHigh Accuracy \u0026amp; Fast Response:\u003c\/strong\u003e\u003cbr data-start=\"2061\" data-end=\"2064\"\u003eAccurate flow detection with a response speed of up to \u003cstrong data-start=\"2121\" data-end=\"2133\"\u003e0.03 m\/s\u003c\/strong\u003e—suitable for both standard and precision monitoring applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2201\" data-end=\"2204\"\u003e\n\u003ch3 data-start=\"2206\" data-end=\"2231\"\u003e\u003cstrong data-start=\"2210\" data-end=\"2231\"\u003eIdeal For Use In:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2233\" data-end=\"2425\"\u003e\n\u003cli data-start=\"2233\" data-end=\"2265\"\u003e\n\u003cp data-start=\"2235\" data-end=\"2265\"\u003eUltrasonic Cleaning Machines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2266\" data-end=\"2304\"\u003e\n\u003cp data-start=\"2268\" data-end=\"2304\"\u003eManufacturing Equipment Monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2305\" data-end=\"2335\"\u003e\n\u003cp data-start=\"2307\" data-end=\"2335\"\u003eIndustrial Washing Systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2336\" data-end=\"2370\"\u003e\n\u003cp data-start=\"2338\" data-end=\"2370\"\u003eCompact Flow Monitoring Setups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2371\" data-end=\"2425\"\u003e\n\u003cp data-start=\"2373\" data-end=\"2425\"\u003eEnvironments Requiring Fast Setup \u0026amp; Minimal Downtime\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" height=\"420\" width=\"602\"\u003e\n\u003ccolgroup\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003eVelocity Rate\u003c\/td\u003e\n\u003ctd\u003e0.328 ft\/s～±16ft\/s(0.1m\/s～±5m\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±2.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"40\" rowspan=\"2\"\u003ePipe Size\u003c\/td\u003e\n\u003ctd\u003eDN4 DN8 DN10 DN15 DN20 DN25 DN32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd\u003eDN40 DN50 DN65 DN80 DN100 DN125 DN200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003eLiquid\u003c\/td\u003e\n\u003ctd\u003eRegular water,sea water,cooling\/hot water,alcohol..\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003ePipe Material\u003c\/td\u003e\n\u003ctd\u003ePVC,stainless steel,carbon steel,copper.…\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e9～36V DC,maximum 500mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eSupport MODBUS protocol,RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003eAnalog Output\u003c\/td\u003e\n\u003ctd\u003e4-20mA,Maximum 750Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003eAlarm Output\u003c\/td\u003e\n\u003ctd\u003eOCT upper and lower limit alarm function (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eOLED 128*64 dot-matrix display screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003eKey Panel\u003c\/td\u003e\n\u003ctd\u003eFour touch buttons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003eFlow Unit\u003c\/td\u003e\n\u003ctd\u003eSupport metric unit selection,Cubic Meters(m³),Liters(l),USA Gallons(gal).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"40\" rowspan=\"2\"\u003eTime Unit\u003c\/td\u003e\n\u003ctd\u003e\/hour,\/min,The factory default unit is cubic meters per hour.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd\u003eDaily,Monthly,and Annual Flow Totalizer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"40\" rowspan=\"2\"\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eAmbient:14F～+122F(-10℃～+50℃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd\u003eLiquid:14F～+122F(-10℃～+50℃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003eAmbient Humidity\u003c\/td\u003e\n\u003ctd\u003eRH 0～95%,No condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eAluminum alloy,CNC machined processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003eProtection Rate\u003c\/td\u003e\n\u003ctd\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e6.6ft (2m)standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eThe Pipe Size Range and Flow Range Reference Table\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" height=\"1500\" width=\"1014\"\u003e\n\u003ccolgroup\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"100\"\u003e\n\u003ctd height=\"100\"\u003e\u003cspan\u003e\u003cstrong\u003eDN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOD\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOD Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eInch\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFlow Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd height=\"100\" rowspan=\"3\"\u003eDN4\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003eOD9.53\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e95mm-10.5mm\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e0.003～0.142 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e0.047～2.374 I\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e0.013～0.627 gal\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd height=\"100\" rowspan=\"3\"\u003eDN8\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003eOD12.7\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e12.4mm-13.1mm\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e0.011～0.570 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e0.190～9.496 I\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e0.050～2.509 gal\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd height=\"100\" rowspan=\"3\"\u003eDN10\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003eOD15\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e14.5mm-15.4mm\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e0.026～1.282 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e0.427～21.366 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e0.113～5.644 gal\/mir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd height=\"100\" rowspan=\"3\"\u003eDN15\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003eOD20\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e16.5mm-23.0mm\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e1\/2\"\u003c\/td\u003e\n\u003ctd\u003e0.046～2.279 m\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e0.760～37.984 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e0.201～10.034 gal\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd height=\"100\" rowspan=\"3\"\u003eDN20\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003eOD25\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e25.0mm-30.0mm\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e3\/4\"\u003c\/td\u003e\n\u003ctd\u003e0.103～5.128 m\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e1.709～85.464 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e0.452～22.577 gal\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd height=\"100\" rowspan=\"3\"\u003eDN25\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003eOD32\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e32.0mm-35.0mm\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e0.182～9.116 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e3.039～151.935 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e0.803～40.137 gal\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd height=\"100\" rowspan=\"3\"\u003eDN32\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003eOD40\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e38.0mm-45.0mm\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e1-1\/4\"\u003c\/td\u003e\n\u003ctd\u003e0.285～14.244 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e4.748～237.399 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e1.254～62.714 gal\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd height=\"100\" rowspan=\"3\"\u003eDN40\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003eOD50\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e48.0mm-54.0mm\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e1-1\/2\"\u003c\/td\u003e\n\u003ctd\u003e0.410～20.511 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e6.837～341.854 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e1.806～90.309 gal\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd height=\"100\" rowspan=\"3\"\u003eDN50\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003eOD63\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e58.0mm-64.0mm\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e2\"\u003c\/td\u003e\n\u003ctd\u003e0.729～36.464 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e12.155～607.741 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e3.211～160549 gal\/mir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd height=\"100\" rowspan=\"3\"\u003eDN65\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003eOD75\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e72.0mm-78.0mm\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e2-1\/2\"\u003c\/td\u003e\n\u003ctd\u003e1.140～56.976 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e18.992～949.595 I\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e5.017～250.857 gal\/mir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd height=\"100\" rowspan=\"3\"\u003eDN80\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003eOD90\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e80.0mm-92.0mm\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e1.641～82.045 m\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e27.348～1367.417 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e7.225～361.234 gal\/mir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd height=\"100\" rowspan=\"3\"\u003eDN100\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003eOD110\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e108.0mm-116.0mm\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e4\"\u003c\/td\u003e\n\u003ctd\u003e2.917～145.858 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e48.619～2430.963 I\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e12.844～642.194 gal\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd height=\"100\" rowspan=\"3\"\u003eDN125\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003eOD140\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e132.0mm-142.0mm\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e5\"\u003c\/td\u003e\n\u003ctd\u003e4.558～227.903 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e75.968～3798.380 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e20.069～1003429 gal\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd height=\"100\" rowspan=\"3\"\u003eDN200\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003eOD220\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e218.0mm-228.0mm\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e8\"\u003c\/td\u003e\n\u003ctd\u003e11.669～583.431 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e194.477～9723.852 I\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e51.376～2568.778 gal\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Flo Instru","offers":[{"title":"DN4 (1\/8\" \/ 9.5mm ~ 10.5mm)","offer_id":48427457413349,"sku":"TM601 Plus","price":2280.0,"currency_code":"NZD","in_stock":true},{"title":"DN8 (1\/4\" \/ 12.4mm ~ 13.1mm)","offer_id":48427457446117,"sku":null,"price":2280.0,"currency_code":"NZD","in_stock":true},{"title":"DN10 (3\/8\" \/ 14.5mm ~ 15.4mm)","offer_id":48427457478885,"sku":null,"price":2280.0,"currency_code":"NZD","in_stock":true},{"title":"DN15 (1\/2\" \/ 16.5mm ~ 23.0mm)","offer_id":48427457511653,"sku":null,"price":2280.0,"currency_code":"NZD","in_stock":true},{"title":"DN20 (3\/4\" \/ 25.0mm ~ 30.0mm)","offer_id":48427457544421,"sku":null,"price":2280.0,"currency_code":"NZD","in_stock":true},{"title":"DN25 (1\" \/ 32.0mm ~ 35.0mm)","offer_id":48427457577189,"sku":null,"price":2280.0,"currency_code":"NZD","in_stock":true},{"title":"DN32 (1-1\/4\" \/ 38.0mm ~ 45.0mm)","offer_id":48427457609957,"sku":null,"price":2370.0,"currency_code":"NZD","in_stock":true},{"title":"DN40 (1-1\/2\" \/ 48.0mm ~ 54.0mm)","offer_id":48427457642725,"sku":null,"price":2760.0,"currency_code":"NZD","in_stock":true},{"title":"DN50 (2\" \/ 58.0mm ~ 64.0mm)","offer_id":48427457675493,"sku":null,"price":2930.0,"currency_code":"NZD","in_stock":true},{"title":"DN65 (2-1\/2\" \/ 72.0mm ~ 78.0mm)","offer_id":48427457708261,"sku":null,"price":2950.0,"currency_code":"NZD","in_stock":true},{"title":"DN80 (3\" \/ 80.0mm ~ 92.0mm)","offer_id":48427457741029,"sku":null,"price":3870.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pl169298836-tm601_digital_ultrasonic_flowmeter_for_water_cooling_system_monitoring.webp?v=1771409962"},{"product_id":"ultrasonic-flowmeter-clamp-on-for-large-pipe-tm601-plus","title":"Ultrasonic Flow Meter TM601 Plus","description":"\u003ch3 data-start=\"690\" data-end=\"718\"\u003e\u003cstrong data-start=\"694\" data-end=\"718\"\u003eProduct Description:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"720\" data-end=\"1153\"\u003e\u003cstrong data-start=\"720\" data-end=\"794\"\u003eSnap-On Simplicity. Precision Measurement. Optimized for Larger Pipes.\u003c\/strong\u003e\u003cbr data-start=\"794\" data-end=\"797\"\u003eThe \u003cstrong data-start=\"801\" data-end=\"845\"\u003eTM601 Plus Clamp-On Ultrasonic Flowmeter\u003c\/strong\u003e is engineered specifically for \u003cstrong data-start=\"877\" data-end=\"908\"\u003eultrasonic cleaning systems\u003c\/strong\u003e that involve \u003cstrong data-start=\"922\" data-end=\"947\"\u003elarger pipe diameters\u003c\/strong\u003e. Featuring a \u003cstrong data-start=\"961\" data-end=\"982\"\u003esnap-on main unit\u003c\/strong\u003e and a \u003cstrong data-start=\"989\" data-end=\"1029\"\u003enon-intrusive clamp-on sensor design\u003c\/strong\u003e, the TM601 Plus enables \u003cstrong data-start=\"1054\" data-end=\"1098\"\u003etool-free installation in under 1 minute\u003c\/strong\u003e, without halting production or modifying the pipeline.\u003c\/p\u003e\n\u003cp data-start=\"1155\" data-end=\"1495\"\u003eIts enhanced design allows precise flow measurement across a wide variety of \u003cstrong data-start=\"1232\" data-end=\"1250\"\u003epipe materials\u003c\/strong\u003e, including stainless steel, carbon steel, copper, PVC, PVDF, PPR, PPH, and HDPE. With an \u003cstrong data-start=\"1340\" data-end=\"1368\"\u003eOLED display (128×64 px)\u003c\/strong\u003e for clear readings even in low-light environments, the TM601 Plus delivers performance and convenience in one compact package.\u003c\/p\u003e\n\u003chr data-start=\"1497\" data-end=\"1500\"\u003e\n\u003ch3 data-start=\"1502\" data-end=\"1534\"\u003e\u003cstrong data-start=\"1506\" data-end=\"1534\"\u003eKey Features \u0026amp; Benefits:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1536\" data-end=\"2399\"\u003e\n\u003cli data-start=\"1536\" data-end=\"1675\"\u003e\n\u003cp data-start=\"1538\" data-end=\"1675\"\u003e\u003cstrong data-start=\"1538\" data-end=\"1572\"\u003eClamp-On, Non-Invasive Design:\u003c\/strong\u003e\u003cbr data-start=\"1572\" data-end=\"1575\"\u003eNo pipe cutting, no pressure loss, and no production downtime—installation is completely external.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1677\" data-end=\"1833\"\u003e\n\u003cp data-start=\"1679\" data-end=\"1833\"\u003e\u003cstrong data-start=\"1679\" data-end=\"1712\"\u003eSnap-On Display Installation:\u003c\/strong\u003e\u003cbr data-start=\"1712\" data-end=\"1715\"\u003eThe main display unit features a built-in buckle system that clamps easily onto the bracket without tools or screws.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1835\" data-end=\"2012\"\u003e\n\u003cp data-start=\"1837\" data-end=\"2012\"\u003e\u003cstrong data-start=\"1837\" data-end=\"1864\"\u003eBuilt for Bigger Pipes:\u003c\/strong\u003e\u003cbr data-start=\"1864\" data-end=\"1867\"\u003eIncludes an enlarged pipe clamp and bracket system designed to accommodate larger diameters with sensors positioned for optimal flow detection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2014\" data-end=\"2116\"\u003e\n\u003cp data-start=\"2016\" data-end=\"2116\"\u003e\u003cstrong data-start=\"2016\" data-end=\"2037\"\u003eUltra-Fast Setup:\u003c\/strong\u003e\u003cbr data-start=\"2037\" data-end=\"2040\"\u003eGet started in just \u003cstrong data-start=\"2062\" data-end=\"2074\"\u003e1 minute\u003c\/strong\u003e—perfect for time-sensitive installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2118\" data-end=\"2239\"\u003e\n\u003cp data-start=\"2120\" data-end=\"2239\"\u003e\u003cstrong data-start=\"2120\" data-end=\"2144\"\u003eOLED Display Screen:\u003c\/strong\u003e\u003cbr data-start=\"2144\" data-end=\"2147\"\u003eHigh-contrast 128×64 pixel screen ensures visibility in both bright and dark environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2241\" data-end=\"2399\"\u003e\n\u003cp data-start=\"2243\" data-end=\"2399\"\u003e\u003cstrong data-start=\"2243\" data-end=\"2276\"\u003eVersatile Pipe Compatibility:\u003c\/strong\u003e\u003cbr data-start=\"2276\" data-end=\"2279\"\u003eSuitable for a range of pipe materials including stainless steel, carbon steel, copper, PVC, PVDF, PPR, PPH, and HDPE.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2401\" data-end=\"2404\"\u003e\n\u003ch3 data-start=\"2406\" data-end=\"2431\"\u003e\u003cstrong data-start=\"2410\" data-end=\"2431\"\u003eIdeal For Use In:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2433\" data-end=\"2630\"\u003e\n\u003cli data-start=\"2433\" data-end=\"2479\"\u003e\n\u003cp data-start=\"2435\" data-end=\"2479\"\u003eUltrasonic Cleaning Machines (Large Scale)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2480\" data-end=\"2522\"\u003e\n\u003cp data-start=\"2482\" data-end=\"2522\"\u003eIndustrial Washing \u0026amp; Rinsing Equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2523\" data-end=\"2568\"\u003e\n\u003cp data-start=\"2525\" data-end=\"2568\"\u003eProcess Equipment in Manufacturing Plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2569\" data-end=\"2630\"\u003e\n\u003cp data-start=\"2571\" data-end=\"2630\"\u003eEnvironments Requiring Fast, Non-Disruptive Installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" height=\"420\" width=\"602\"\u003e\n\u003ccolgroup\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003eVelocity Rate\u003c\/td\u003e\n\u003ctd\u003e0.328 ft\/s～±16ft\/s(0.1m\/s～±5m\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±2.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"40\"\u003ePipe Size\u003c\/td\u003e\n\u003ctd\u003eDN100 DN125 DN160 DN200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003eLiquid\u003c\/td\u003e\n\u003ctd\u003eRegular water,sea water,cooling\/hot water,alcohol..\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003ePipe Material\u003c\/td\u003e\n\u003ctd\u003ePVC,stainless steel,carbon steel,copper.…\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e9～36V DC,maximum 500mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eSupport MODBUS protocol,RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003eAnalog Output\u003c\/td\u003e\n\u003ctd\u003e4-20mA,Maximum 750Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003eAlarm Output\u003c\/td\u003e\n\u003ctd\u003eOCT upper and lower limit alarm function (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eOLED 128*64 dot-matrix display screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003eKey Panel\u003c\/td\u003e\n\u003ctd\u003eFour touch buttons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003eFlow Unit\u003c\/td\u003e\n\u003ctd\u003eSupport metric unit selection,Cubic Meters(m³),Liters(l),USA Gallons(gal).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"40\" rowspan=\"2\"\u003eTime Unit\u003c\/td\u003e\n\u003ctd\u003e\/hour,\/min,The factory default unit is cubic meters per hour.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd\u003eDaily,Monthly,and Annual Flow Totalizer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"40\" rowspan=\"2\"\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eAmbient:14F～+122F(-10℃～+50℃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd\u003eLiquid:14F～+122F(-10℃～+50℃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003eAmbient Humidity\u003c\/td\u003e\n\u003ctd\u003eRH 0～95%,No condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eAluminum alloy,CNC machined processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003eProtection Rate\u003c\/td\u003e\n\u003ctd\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd height=\"20\"\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e6.6ft (2m)standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eThe Pipe Size Range and Flow Range Reference Table\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" height=\"1500\" width=\"1014\"\u003e\n\u003ccolgroup\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"100\"\u003e\n\u003ctd height=\"100\"\u003e\u003cspan\u003e\u003cstrong\u003eDN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOD\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOD Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eInch\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFlow Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd height=\"100\" rowspan=\"3\"\u003eDN100\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003eOD110\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e108mm-116mm\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e4\"\u003c\/td\u003e\n\u003ctd\u003e2.917～145.858 m\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e48.619～2430.963 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e12.844～642.194 gal\/mir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd height=\"100\" rowspan=\"3\"\u003eDN125\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003eOD140\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e132mm-142mm\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e5\"\u003c\/td\u003e\n\u003ctd\u003e4.558～227.903 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e75.968～3798.380 I\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e20.069～1003.429 gal\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd height=\"100\" rowspan=\"3\"\u003eDN150\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003eOD160\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e158mm-168mm\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e6\"\u003c\/td\u003e\n\u003ctd\u003e6.564～328.180 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e109.393～5469.666 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e28.889～1444.938 gal\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd height=\"100\" rowspan=\"3\"\u003eDN220\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003eOD220\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e218mm-228mm\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e8\"\u003c\/td\u003e\n\u003ctd\u003e11.669～583.431 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e194.477～9723.852 I\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\"\u003e\n\u003ctd\u003e51.376～2568.778 gal\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Flo Instru","offers":[{"title":"DN100 (4\" \/ 108.0mm ~ 116.0mm)","offer_id":48427457806565,"sku":"TM601 Plus","price":4860.0,"currency_code":"NZD","in_stock":true},{"title":"DN125 (5\" \/ 115.0mm ~ 142.0mm)","offer_id":48427457839333,"sku":null,"price":5670.0,"currency_code":"NZD","in_stock":true},{"title":"DN150 (6\" \/ 142.0mm ~ 169.0mm)","offer_id":48427457872101,"sku":null,"price":6490.0,"currency_code":"NZD","in_stock":true},{"title":"DN175 (7\" \/ 169.0mm ~ 196.0mm)","offer_id":48427457904869,"sku":null,"price":7300.0,"currency_code":"NZD","in_stock":true},{"title":"DN200 (8\" \/ 196.0mm ~ 223.0mm)","offer_id":48427457937637,"sku":null,"price":8120.0,"currency_code":"NZD","in_stock":true},{"title":"DN225 (9\" \/ 223.0mm ~ 250.0mm)","offer_id":48427457970405,"sku":null,"price":8940.0,"currency_code":"NZD","in_stock":true},{"title":"DN250 (10\" \/ 250.0mm ~ 277.0mm)","offer_id":48427458003173,"sku":null,"price":9750.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pl179460653-tm601_plus_ultrasonic_flowmeter_no_special_tools_required_for_hvac_building_management.webp?v=1771409973"},{"product_id":"ultrasonic-energy-meter-clamp-on-se509","title":"Ultrasonic Energy Meter SE509","description":"\u003ch3 data-start=\"690\" data-end=\"718\"\u003e\u003cstrong data-start=\"694\" data-end=\"718\"\u003eProduct Description:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"720\" data-end=\"1200\"\u003e\u003cstrong data-start=\"720\" data-end=\"802\"\u003ePrecision Energy Monitoring. Non-Invasive Installation. Built for Performance.\u003c\/strong\u003e\u003cbr data-start=\"802\" data-end=\"805\"\u003eThe \u003cstrong data-start=\"809\" data-end=\"851\"\u003eSE509 Clamp-On Ultrasonic Energy Meter\u003c\/strong\u003e is a compact and accurate solution for monitoring \u003cstrong data-start=\"902\" data-end=\"932\"\u003ethermal energy consumption\u003c\/strong\u003e in \u003cstrong data-start=\"936\" data-end=\"980\"\u003eliquid-based heating and cooling systems\u003c\/strong\u003e. Equipped with \u003cstrong data-start=\"996\" data-end=\"1026\"\u003ePT1000 temperature sensors\u003c\/strong\u003e and advanced \u003cstrong data-start=\"1040\" data-end=\"1080\"\u003eTVT (Transit-Time Vortex) technology\u003c\/strong\u003e, this system accurately calculates energy usage using data from \u003cstrong data-start=\"1145\" data-end=\"1171\"\u003etwo temperature inputs\u003c\/strong\u003e and an ultrasonic flowmeter.\u003c\/p\u003e\n\u003cp data-start=\"1202\" data-end=\"1511\"\u003eThe \u003cstrong data-start=\"1206\" data-end=\"1230\"\u003eclamp-on transducers\u003c\/strong\u003e ensure \u003cstrong data-start=\"1238\" data-end=\"1257\"\u003eno pipe cutting\u003c\/strong\u003e, \u003cstrong data-start=\"1259\" data-end=\"1274\"\u003eno downtime\u003c\/strong\u003e, and \u003cstrong data-start=\"1280\" data-end=\"1300\"\u003eno pressure loss\u003c\/strong\u003e, making the SE509 ideal for retrofit projects and ongoing operations. It’s designed to handle pipe sizes from \u003cstrong data-start=\"1411\" data-end=\"1440\"\u003e1\" (25mm) to 80\" (2000mm)\u003c\/strong\u003e and includes \u003cstrong data-start=\"1454\" data-end=\"1480\"\u003eIP68-rated transducers\u003c\/strong\u003e for use in harsh environments.\u003c\/p\u003e\n\u003chr data-start=\"1513\" data-end=\"1516\"\u003e\n\u003ch3 data-start=\"1518\" data-end=\"1550\"\u003e\u003cstrong data-start=\"1522\" data-end=\"1550\"\u003eKey Features \u0026amp; Benefits:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1552\" data-end=\"2641\"\u003e\n\u003cli data-start=\"1552\" data-end=\"1745\"\u003e\n\u003cp data-start=\"1554\" data-end=\"1745\"\u003e\u003cstrong data-start=\"1554\" data-end=\"1604\"\u003eThermal Energy Monitoring with PT1000 Sensors:\u003c\/strong\u003e\u003cbr data-start=\"1604\" data-end=\"1607\"\u003eMeasures the energy transfer in both heating and cooling applications by capturing temperature differentials in supply and return lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1747\" data-end=\"1931\"\u003e\n\u003cp data-start=\"1749\" data-end=\"1931\"\u003e\u003cstrong data-start=\"1749\" data-end=\"1790\"\u003eTVT (Transit-Time Vortex) Technology:\u003c\/strong\u003e\u003cbr data-start=\"1790\" data-end=\"1793\"\u003eAdvanced measurement method combining time-of-flight and vortex detection to maintain high accuracy in both laminar and turbulent flows.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1933\" data-end=\"2090\"\u003e\n\u003cp data-start=\"1935\" data-end=\"2090\"\u003e\u003cstrong data-start=\"1935\" data-end=\"1969\"\u003eClamp-On, Non-Invasive Design:\u003c\/strong\u003e\u003cbr data-start=\"1969\" data-end=\"1972\"\u003eInstalls externally—no need to cut into pipes or interrupt operations. Ideal for system retrofits and energy audits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2092\" data-end=\"2228\"\u003e\n\u003cp data-start=\"2094\" data-end=\"2228\"\u003e\u003cstrong data-start=\"2094\" data-end=\"2121\"\u003eIndustrial-Grade Build:\u003c\/strong\u003e\u003cbr data-start=\"2121\" data-end=\"2124\"\u003eHoused in a rugged metal enclosure with high-grade materials for durability and long-term performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2230\" data-end=\"2377\"\u003e\n\u003cp data-start=\"2232\" data-end=\"2377\"\u003e\u003cstrong data-start=\"2232\" data-end=\"2260\"\u003eWide Pipe Compatibility:\u003c\/strong\u003e\u003cbr data-start=\"2260\" data-end=\"2263\"\u003eSupports pipe diameters from 1\" (25mm) up to 80\" (2000mm), covering most commercial and industrial applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2379\" data-end=\"2505\"\u003e\n\u003cp data-start=\"2381\" data-end=\"2505\"\u003e\u003cstrong data-start=\"2381\" data-end=\"2402\"\u003eIP68 Transducers:\u003c\/strong\u003e\u003cbr data-start=\"2402\" data-end=\"2405\"\u003eDesigned for submersion and tough environments, ensuring reliable data in humid or wet conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2507\" data-end=\"2641\"\u003e\n\u003cp data-start=\"2509\" data-end=\"2641\"\u003e\u003cstrong data-start=\"2509\" data-end=\"2540\"\u003eClear, Intuitive Interface:\u003c\/strong\u003e\u003cbr data-start=\"2540\" data-end=\"2543\"\u003eSimple setup with an easy-to-read display and user-friendly menu system for quick configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2643\" data-end=\"2646\"\u003e\n\u003ch3 data-start=\"2648\" data-end=\"2675\"\u003e\u003cstrong data-start=\"2652\" data-end=\"2675\"\u003eIdeal Applications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2677\" data-end=\"2883\"\u003e\n\u003cli data-start=\"2677\" data-end=\"2713\"\u003e\n\u003cp data-start=\"2679\" data-end=\"2713\"\u003eHVAC Systems (Heating \u0026amp; Cooling)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2714\" data-end=\"2757\"\u003e\n\u003cp data-start=\"2716\" data-end=\"2757\"\u003eChilled Water and Condenser Water Loops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2758\" data-end=\"2788\"\u003e\n\u003cp data-start=\"2760\" data-end=\"2788\"\u003eDistrict Energy Monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2789\" data-end=\"2826\"\u003e\n\u003cp data-start=\"2791\" data-end=\"2826\"\u003eBuilding Management Systems (BMS)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2827\" data-end=\"2883\"\u003e\n\u003cp data-start=\"2829\" data-end=\"2883\"\u003eEnergy Audits for Commercial \u0026amp; Industrial Facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable align=\"left\" border=\"1\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003ePerformance Index\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Range\u003c\/td\u003e\n\u003ctd\u003e0m\/s ~ 12m\/s(0ft\/s ~ 40ft\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eValued ±1.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e2.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp align=\"justify\"\u003ePipe Diameter\u003c\/p\u003e\n\u003cp align=\"justify\"\u003eRange(Optional)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eDN25~DN2000 (1’’ ~ 80’’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Medium\u003c\/td\u003e\n\u003ctd\u003ewater, sea water, oil,alcohol...\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe Material(Optional)\u003c\/td\u003e\n\u003ctd\u003ePVC, stainless steel, carbon steel, copper...\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eFunction Index\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eModBus RS485, 4～20mA, Maximum load: 750Ω, OCT upper and lower limit alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeyboard\u003c\/td\u003e\n\u003ctd\u003e4 touch keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e2.2\" TFT LCD 320*240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eTransmitter ambient temperature: -40℉~140℉(-40℃~60℃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer measurement medium: -40℉~176℉(-40℃~80℃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePT1000 Temp. Sensor: 35.6℉~221℉(2℃~105℃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003eRH 0~95% RH,non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP\u003c\/td\u003e\n\u003ctd\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Unit\u003c\/td\u003e\n\u003ctd\u003eSupport metric unit selection,Cubic Meters(m3), Liters(l),USA Gallons(gal).\u003cbr\u003e\/hour, \/min, The factory default unit is m3 per hour.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Unit\u003c\/td\u003e\n\u003ctd\u003eGiga Joule (GJ), Kilocalorie (Kc), KWh, BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003ePhysical Characteristics\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter\u003c\/td\u003e\n\u003ctd\u003eAluminum alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor\u003c\/td\u003e\n\u003ctd\u003eClamp-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003eStandard length: 10m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan\u003ePT1000 Reference Table\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" height=\"312\" width=\"792\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"82\"\u003e\n\u003ccol span=\"10\" width=\"71\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"24\"\u003e\n\u003ctd class=\"et2\" height=\"24\" width=\"82\"\u003eTemperature\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"71\"\u003e0\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"71\"\u003e1\u003c\/td\u003e\n\u003ctd class=\"et4\" width=\"71\"\u003e2\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"71\"\u003e3\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"71\"\u003e4\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"71\"\u003e5\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"71\"\u003e6\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"71\"\u003e7\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"71\"\u003e8\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"71\"\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"24\"\u003e\n\u003ctd class=\"et5\" height=\"24\" width=\"82\"\u003e\n\u003cspan class=\"font3\"\u003e(\u003c\/span\u003e\u003cspan class=\"font5\"\u003e℃\u003c\/span\u003e\u003cspan class=\"font3\"\u003e)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd class=\"et6\" colspan=\"10\" width=\"710\"\u003eResistance value (Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"24\"\u003e\n\u003ctd class=\"et8\" height=\"24\" width=\"82\"\u003e0\u003c\/td\u003e\n\u003ctd class=\"et9\" width=\"71\"\u003e1000.0\u003c\/td\u003e\n\u003ctd class=\"et10\" width=\"71\"\u003e1003.9\u003c\/td\u003e\n\u003ctd class=\"et11\" width=\"71\"\u003e1007.8\u003c\/td\u003e\n\u003ctd class=\"et9\" width=\"71\"\u003e1011.7\u003c\/td\u003e\n\u003ctd class=\"et10\" width=\"71\"\u003e1015.6\u003c\/td\u003e\n\u003ctd class=\"et11\" width=\"71\"\u003e1019.5\u003c\/td\u003e\n\u003ctd class=\"et11\" width=\"71\"\u003e1023.4\u003c\/td\u003e\n\u003ctd class=\"et9\" width=\"71\"\u003e1027.3\u003c\/td\u003e\n\u003ctd class=\"et11\" width=\"71\"\u003e1031.2\u003c\/td\u003e\n\u003ctd class=\"et9\" width=\"71\"\u003e1035.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"24\"\u003e\n\u003ctd class=\"et12\" height=\"24\" width=\"82\"\u003e10\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1039.0\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1042.9\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1046.8\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1050.7\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1054.6\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1058.5\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1062.4\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1066.3\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1070.2\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1074.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"24\"\u003e\n\u003ctd class=\"et14\" height=\"24\" width=\"82\"\u003e20\u003c\/td\u003e\n\u003ctd class=\"et9\" width=\"71\"\u003e1077.9\u003c\/td\u003e\n\u003ctd class=\"et9\" width=\"71\"\u003e1081.8\u003c\/td\u003e\n\u003ctd class=\"et9\" width=\"71\"\u003e1085.7\u003c\/td\u003e\n\u003ctd class=\"et9\" width=\"71\"\u003e1089.6\u003c\/td\u003e\n\u003ctd class=\"et15\" width=\"71\"\u003e1093.5\u003c\/td\u003e\n\u003ctd class=\"et9\" width=\"71\"\u003e1097.3\u003c\/td\u003e\n\u003ctd class=\"et9\" width=\"71\"\u003e1101.2\u003c\/td\u003e\n\u003ctd class=\"et9\" width=\"71\"\u003e1105.1\u003c\/td\u003e\n\u003ctd class=\"et9\" width=\"71\"\u003e1109.0\u003c\/td\u003e\n\u003ctd class=\"et20\" width=\"71\"\u003e1112.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"24\"\u003e\n\u003ctd class=\"et12\" height=\"24\" width=\"82\"\u003e30\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1116.7\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1120.6\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1124.5\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1128.3\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1132.2\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1136.1\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1139.9\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1143.8\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1117.7\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1151.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"24\"\u003e\n\u003ctd class=\"et8\" height=\"24\" width=\"82\"\u003e40\u003c\/td\u003e\n\u003ctd class=\"et9\" width=\"71\"\u003e1155.4\u003c\/td\u003e\n\u003ctd class=\"et16\" width=\"71\"\u003e1159.3\u003c\/td\u003e\n\u003ctd class=\"et9\" width=\"71\"\u003e1163.1\u003c\/td\u003e\n\u003ctd class=\"et16\" width=\"71\"\u003e1167.0\u003c\/td\u003e\n\u003ctd class=\"et15\" width=\"71\"\u003e1170.8\u003c\/td\u003e\n\u003ctd class=\"et9\" width=\"71\"\u003e1174.7\u003c\/td\u003e\n\u003ctd class=\"et9\" width=\"71\"\u003e1178.5\u003c\/td\u003e\n\u003ctd class=\"et21\" width=\"71\"\u003e1182.4\u003c\/td\u003e\n\u003ctd class=\"et10\" width=\"71\"\u003e1186.2\u003c\/td\u003e\n\u003ctd class=\"et16\" width=\"71\"\u003e1190.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"24\"\u003e\n\u003ctd class=\"et12\" height=\"24\" width=\"82\"\u003e50\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1194.0\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1197.8\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1201.6\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1205.5\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1209.3\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1213.2\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1217.0\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1220.9\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1224.7\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1228.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"24\"\u003e\n\u003ctd class=\"et17\" height=\"24\" width=\"82\"\u003e60\u003c\/td\u003e\n\u003ctd class=\"et9\" width=\"71\"\u003e1232.4\u003c\/td\u003e\n\u003ctd class=\"et10\" width=\"71\"\u003e1236.2\u003c\/td\u003e\n\u003ctd class=\"et9\" width=\"71\"\u003e1240.1\u003c\/td\u003e\n\u003ctd class=\"et16\" width=\"71\"\u003e1243.9\u003c\/td\u003e\n\u003ctd class=\"et15\" width=\"71\"\u003e1247.7\u003c\/td\u003e\n\u003ctd class=\"et9\" width=\"71\"\u003e1251.6\u003c\/td\u003e\n\u003ctd class=\"et9\" width=\"71\"\u003e1255.4\u003c\/td\u003e\n\u003ctd class=\"et10\" width=\"71\"\u003e1259.2\u003c\/td\u003e\n\u003ctd class=\"et10\" width=\"71\"\u003e1263.1\u003c\/td\u003e\n\u003ctd class=\"et16\" width=\"71\"\u003e1226.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"24\"\u003e\n\u003ctd class=\"et12\" height=\"24\" width=\"82\"\u003e70\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1270.7\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1274.5\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1278.4\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1282.2\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1286.0\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1280.8\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1293.7\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1297.5\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1301.3\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1305.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"24\"\u003e\n\u003ctd class=\"et14\" height=\"24\" width=\"82\"\u003e80\u003c\/td\u003e\n\u003ctd class=\"et9\" width=\"71\"\u003e1308.9\u003c\/td\u003e\n\u003ctd class=\"et10\" width=\"71\"\u003e1302.7\u003c\/td\u003e\n\u003ctd class=\"et9\" width=\"71\"\u003e1316.6\u003c\/td\u003e\n\u003ctd class=\"et16\" width=\"71\"\u003e1320.4\u003c\/td\u003e\n\u003ctd class=\"et15\" width=\"71\"\u003e1324.2\u003c\/td\u003e\n\u003ctd class=\"et16\" width=\"71\"\u003e1320.8\u003c\/td\u003e\n\u003ctd class=\"et16\" width=\"71\"\u003e1331.8\u003c\/td\u003e\n\u003ctd class=\"et15\" width=\"71\"\u003e1335.6\u003c\/td\u003e\n\u003ctd class=\"et16\" width=\"71\"\u003e1339.4\u003c\/td\u003e\n\u003ctd class=\"et16\" width=\"71\"\u003e1343.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"24\"\u003e\n\u003ctd class=\"et12\" height=\"24\" width=\"82\"\u003e90\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1347.0\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1350.8\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1354.6\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1358.4\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1362.2\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1366.0\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1369.8\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1373.6\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1377.4\u003c\/td\u003e\n\u003ctd class=\"et13\" width=\"71\"\u003e1381.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"24\"\u003e\n\u003ctd class=\"et18\" height=\"24\" width=\"82\"\u003e100\u003c\/td\u003e\n\u003ctd class=\"et9\" width=\"71\"\u003e1385.0\u003c\/td\u003e\n\u003ctd class=\"et10\" width=\"71\"\u003e1388.8\u003c\/td\u003e\n\u003ctd class=\"et9\" width=\"71\"\u003e1392.6\u003c\/td\u003e\n\u003ctd class=\"et16\" width=\"71\"\u003e1396.4\u003c\/td\u003e\n\u003ctd class=\"et15\" width=\"71\"\u003e1400.2\u003c\/td\u003e\n\u003ctd class=\"et16\" width=\"71\"\u003e1403.9\u003c\/td\u003e\n\u003ctd class=\"et9\" width=\"71\"\u003e1407.7\u003c\/td\u003e\n\u003ctd class=\"et16\" width=\"71\"\u003e1411.5\u003c\/td\u003e\n\u003ctd class=\"et16\" width=\"71\"\u003e1415.3\u003c\/td\u003e\n\u003ctd class=\"et16\" width=\"71\"\u003e1419.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Flo Instru","offers":[{"title":"Default Title","offer_id":48427458068709,"sku":"SE509","price":5480.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pl170085911-se509_separate_ultrasonic_energy_flowmeter_for_power_plant.webp?v=1771409994"}],"url":"https:\/\/inspectec.co.nz\/collections\/flow-measurement.oembed?page=2","provider":"Inspectec","version":"1.0","type":"link"}