{"title":"insulation-resistance-testers","description":null,"products":[{"product_id":"1000v-digital-insulation-resistance-tester-cem-dt-5505","title":"1000 V Digital Insulation Resistance Tester – DT-5505","description":"\u003cp\u003eThe \u003cstrong\u003eCEM DT-5505\u003c\/strong\u003e is a compact professional insulation resistance tester for commissioning, troubleshooting and preventative maintenance on motors, generators, cables, switchgear and other electrical equipment.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation test voltages: 125 V, 250 V, 500 V and 1000 V\u003c\/li\u003e\n\u003cli\u003eInsulation resistance measurement up to 4000 MΩ\u003c\/li\u003e\n\u003cli\u003e1 mA nominal insulation test current at rated voltage\u003c\/li\u003e\n\u003cli\u003eLow-resistance and continuity testing\u003c\/li\u003e\n\u003cli\u003eAC and DC voltage measurement\u003c\/li\u003e\n\u003cli\u003eAutomatic discharge of capacitive voltage after testing\u003c\/li\u003e\n\u003cli\u003eLive-circuit detection inhibits insulation testing when voltage above 30 V is detected\u003c\/li\u003e\n\u003cli\u003eData Hold and Min\/Max functions\u003c\/li\u003e\n\u003cli\u003eBacklit dual display with analogue bargraph\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V \/ CAT III 1000 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMotors and generators\u003c\/li\u003e\n\u003cli\u003ePower and control cables\u003c\/li\u003e\n\u003cli\u003eSwitchgear and distribution equipment\u003c\/li\u003e\n\u003cli\u003eElectrical installation maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e CEM DT-5505\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 20px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eInsulation test voltages\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e125 V \/ 250 V \/ 500 V \/ 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eUp to 4000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eLow resistance\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eContinuity test\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eVoltage measurement\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eAC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eSafety features\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eAuto-discharge and live-circuit detection above 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eLarge backlit LCD with analogue bar graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eSafety rating\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eIEC 61010-1, CAT IV 600 V \/ CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eDatasheet\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/DT-5505-1.pdf?v=1789871377\" target=\"_blank\" rel=\"noopener\"\u003eView the CEM DT-5505 datasheet \/ technical document\u003c\/a\u003e\u003c\/p\u003e","brand":"CEM","offers":[{"title":"Default Title","offer_id":68073824125157,"sku":"CEM-DT-5505","price":770.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/63783846.jpg?v=1794269839"},{"product_id":"5kv-high-voltage-insulation-tester-cem-dt-6605","title":"5 kV High Voltage Insulation Tester – DT-6605","description":"\u003cp\u003eThe \u003cstrong\u003eCEM DT-6605\u003c\/strong\u003e is a professional 5 kV high-voltage insulation resistance tester for motors, generators, cables, switchgear and other industrial electrical assets. Its wide test-voltage range and diagnostic functions make it suited to commissioning and preventative maintenance.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation test voltages: 500 V, 1000 V, 2500 V and 5000 V\u003c\/li\u003e\n\u003cli\u003eInsulation resistance measurement up to 60 GΩ\u003c\/li\u003e\n\u003cli\u003ePolarisation Index (PI) measurement\u003c\/li\u003e\n\u003cli\u003eAutomatic ranging and timed testing\u003c\/li\u003e\n\u003cli\u003eOutput-voltage and discharge-voltage indication\u003c\/li\u003e\n\u003cli\u003eAutomatic discharge after insulation testing\u003c\/li\u003e\n\u003cli\u003eVoltage-output warning function\u003c\/li\u003e\n\u003cli\u003e6000-count backlit digital display with bargraph\u003c\/li\u003e\n\u003cli\u003eAC\/DC voltage measurement and continuity function\u003c\/li\u003e\n\u003cli\u003eIEC 61010-1 CAT IV 600 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial motors and generators\u003c\/li\u003e\n\u003cli\u003ePower cables and switchgear\u003c\/li\u003e\n\u003cli\u003eElectrical plant maintenance\u003c\/li\u003e\n\u003cli\u003eHigh-voltage insulation condition checks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e CEM DT-6605\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 20px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eInsulation test voltages\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e500 V \/ 1000 V \/ 2500 V \/ 5000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eUp to 60 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e±5% rdg ±3 dgt; ±20% above 6 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eShort-circuit current\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eApprox. 1.3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eRated test current\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eApprox. 1 mA to 1.2 mA at specified load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eAC\/DC voltage\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e0 to 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eResistance \/ continuity\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e0 to 6000 Ω; buzzer at approx. 50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e6000 counts, backlit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eFunctions\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003ePI, auto-ranging, timer, auto-discharge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eSafety rating\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eIEC 61010-1, CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eDatasheet\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/DT-6605-1.pdf?v=1789871377\" target=\"_blank\" rel=\"noopener\"\u003eView the CEM DT-6605 datasheet \/ technical document\u003c\/a\u003e\u003c\/p\u003e","brand":"CEM","offers":[{"title":"Default Title","offer_id":68073824157925,"sku":"CEM-DT-6605","price":1120.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/f090e64f93b016c78f2187f4ee6e505f.jpg?v=1794269845"},{"product_id":"thermal-imaging-insulation-tester-and-multimeter-cem-dt-6509","title":"Thermal Imaging Insulation Tester \u0026 Multimeter – DT-6509","description":"\u003cp\u003eThe \u003cstrong\u003eCEM DT-6509\u003c\/strong\u003e is a multifunction professional tester integrating insulation resistance testing, a True-RMS digital multimeter and thermal imaging. It is designed for advanced electrical maintenance, EV and hybrid systems, HVAC equipment, motors, switchgear and renewable-energy applications.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation test voltages: 125 V, 250 V, 500 V and 1000 V\u003c\/li\u003e\n\u003cli\u003eInsulation resistance measurement up to 5000 MΩ on the current CEM specification\u003c\/li\u003e\n\u003cli\u003ePolarisation Index (PI) and Dielectric Absorption Ratio (DAR)\u003c\/li\u003e\n\u003cli\u003eIntegrated thermal imager for rapid hot-spot identification\u003c\/li\u003e\n\u003cli\u003eTrue-RMS AC\/DC voltage and current measurement\u003c\/li\u003e\n\u003cli\u003eResistance, capacitance and continuity functions\u003c\/li\u003e\n\u003cli\u003eHigh-resolution low-ohm measurement\u003c\/li\u003e\n\u003cli\u003eLow-pass filter for VFD applications\u003c\/li\u003e\n\u003cli\u003eBluetooth \/ USB data transfer and logging\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V \/ CAT III 1000 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEV and hybrid high-voltage systems\u003c\/li\u003e\n\u003cli\u003eMotors, transformers and switchgear\u003c\/li\u003e\n\u003cli\u003eHVAC compressor and winding diagnostics\u003c\/li\u003e\n\u003cli\u003eSolar PV insulation testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e CEM DT-6509\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 20px 0;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:10px 12px;border:1px solid #dddddd;text-align:left;background:#f4f4f4;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eInstrument type\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e3-in-1 insulation tester, True-RMS multimeter and thermal imager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eInsulation test voltages\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003e125 V \/ 250 V \/ 500 V \/ 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eUp to 5000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eInsulation functions\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003ePI \/ DAR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eMultimeter\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eTrue RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eThermal imaging\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eIntegrated thermal imager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eConnectivity\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eBluetooth and USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;font-weight:600;vertical-align:top;width:38%;\"\u003eSafety rating\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border:1px solid #dddddd;vertical-align:top;\"\u003eCAT IV 600 V \/ CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eDatasheet\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/CEM-DT-6509-datasheet.pdf?v=1789871165\" target=\"_blank\" rel=\"noopener\"\u003eDownload the CEM DT-6509 datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"CEM","offers":[{"title":"Default Title","offer_id":68073824190693,"sku":"CEM-DT-6509","price":4360.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/01_x4qtr9.jpg?v=1794269850"}],"url":"https:\/\/inspectec.co.nz\/collections\/insulation-resistance-testers.oembed","provider":"Inspectec","version":"1.0","type":"link"}