{"title":"PCE Brand","description":"\u003ch1 class=\"main-title main-heading\"\u003eTools and Equipment for Measuring, Weighing and Control Systems\u003c\/h1\u003e\n\u003cdiv class=\"text\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-12 text-justify\"\u003e\n\u003cp\u003ePCE Instruments (PCE) is an international supplier of test instruments, tools and equipment for measuring, weighing and control systems. Founded by German engineers nearly two decades ago, PCE offers more than 500 test instruments with applications in industrial engineering and process control, manufacturing quality assurance, scientific research, trade industries and beyond. PCE’s large test instrument portfolio includes handheld, desktop, portable or fixed-installation sensors, meters, gauges, scales, analyzers, detectors, data loggers and inspection cameras branded by PCE and other first-class manufacturers from around the globe.\u003c\/p\u003e\n\u003cp\u003eIn addition, PCE can provide custom test instruments on demand. The DIN EN ISO 9001-certified PCE Product and Development Company GmbH produces test instruments tailored to meet unique customer needs. PCE serves customers from government,\u003cspan\u003e \u003c\/span\u003e\u003cimg src=\"https:\/\/www.pce-instruments.com\/g\/custom\/category-pictures\/test-instruments-pce-instruments.jpg\" alt=\"Test Instruments\" class=\"img-responsive img-right\"\u003eindustry and academia in diverse fields such as acoustical engineering, aerospace, agriculture, archaeology, architecture, automotive, aviation, bioengineering, building inspection, chemistry, civil engineering, computer science, construction, data acquisition, education, electrical engineering, energy, environmental science, food processing, forensics, forestry, geology, government, horticulture, HVAC, hydrology, industrial hygiene, law enforcement, library science, logistics, machining, maintenance, manufacturing, materials science, mechanical engineering, metal working, meteorology, military, mining, nondestructive testing (NDT), occupational health and safety, oil and gas, pharmaceuticals, property management, pulp and paper, physics, robotics, structural engineering, supply chain, transportation, tribology, veterinary science, water treatment, welding, woodworking and more. By capitalizing on the expert knowledge and extensive experience of PCE’s engineers and technicians to create custom-built test instruments, customers in almost any field can obtain professional tools and equipment designed specifically for their applications.\u003c\/p\u003e\n\u003cp\u003ePCE’s mix of stock and custom test instruments ensures the company remains a trusted partner for professional tools and equipment used in measuring, weighing and control systems.\u003c\/p\u003e\n\u003cp\u003eTest instruments can be found in research laboratories as well as in places like automobile repair shops, construction job sites and manufacturing facilities. Test instruments are used in trade industries for troubleshooting as well as for routine inspections of systems and equipment. Companies big and small need accurate, affordable test instruments for use in product research and development (R\u0026amp;D), quality control, condition monitoring, workplace safety, and more. From accelerometer devices used to measure vibrations and oscillations in machinery to wood moisture meter products designed to determine the humidity of lumber, PCE Instruments’ breadth of test instrument product offerings covers a full range of practical applications. Everyday consumers also need accurate, affordable test instruments for evaluating home energy efficiency, monitoring wind conditions for outdoor recreational activities, checking soil moisture levels in the garden, and more. For these types of applications, PCE Instruments offers a number of easy-to-use test instruments — no expert knowledge required.\u003c\/p\u003e\n\u003cp\u003ePCE's devices are of the highest industry standards, and are used for quality control and product testing in industrial settings, scientific research facilities, commercial businesses, government institutions, professional sports and recreation venues, and military operations. In addition, PCE's test instruments\u003cspan\u003e \u003c\/span\u003e\u003cimg src=\"https:\/\/www.pce-instruments.com\/g\/custom\/category-pictures\/test-instruments-solar-power-test-instruments.jpg\" alt=\"Solar panel test instrument\" class=\"img-responsive img-left\"\u003emay be used in education for classroom demonstrations and laboratory tests. Electricians use PCE test instruments for assessing electrical installations in their daily work. Test instruments are used in the testing, adjusting and balancing (TAB) of heating, ventilation and air conditioning (HVAC) systems, and since energy saving is of pivotal importance on the global level, it is a must to use the latest and most progressive equipment in this sphere. Even solar panel installers use PCE test instruments during the installation and testing of solar panels. Regardless of the intended application, all PCE test instruments are delivered manufacturer calibrated. Plus, PCE Instruments stands by the quality of its test instruments by offering a warranty against manufacturer defects.\u003c\/p\u003e\n\u003cp\u003eThe wide range of test instruments supplied by PCE ensures that no matter the customer need, PCE has a solution — from portable handheld devices for testing in the field to fixed-installation test instruments permanently mounted for continuous monitoring in a facility or at a job site. Let PCE Instruments be your partner for virtually any measuring, weighing or control systems equipment.\u003ca name=\"calibration\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003ePCE Instruments is also a consultancy company, providing services for custom test instrument design, installation, calibration, maintenance and on\/off site monitoring. One of our associates can supply you with the support you need to tackle that large project or installation. With more than 20 years in the industry as a company, and with the hundreds of combined years of experience shared between our knowledgeable associates, PCE Instruments can help solve almost any measuring problem, large or small. We are interested not only in test instrument sales, but also in the development of new measuring solutions to benefit our customers. Our associates attend training courses regularly to keep up with the latest technical innovations and upgrade the capabilities of our test instruments accordingly. Ultimately, PCE strives to provide customers with products and solutions that make measuring tasks quick and easy while maintaining a high level of accuracy, so we embrace new technologies that help accomplish these objectives.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-12\"\u003e\n\u003cdiv class=\"line-horiz\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-12 text-center\"\u003e\n\u003ch2\u003eCALIBRATION OF TEST INSTRUMENTS\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-12 text-justify\"\u003e\n\u003ch2\u003e\u003cimg src=\"https:\/\/www.pce-instruments.com\/g\/custom\/category-pictures\/test-instruments-iso.jpg\" alt=\"Sample ISO Calibration Certificate for Test Instruments\" class=\"img-responsive img-right\" style=\"margin-bottom: 0px; font-size: 0.875rem;\"\u003e\u003c\/h2\u003e\n\u003cp\u003eA\u003cspan style=\"font-size: 0.875rem;\"\u003ell PCE test instruments, tools and equipment for measuring, weighing and control systems are factory or manufacturer calibrated. Should you company require ISO (or DAkkS) calibration,\u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eISO (or DAkkS) calibration certificates can be acquired as an optional accessory at additional cost to most test instruments. While we do not offer NIST calibration, ISO calibration is accepted as an NIST equivalent in the United States, as ISO calibration is respected worldwide.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eAn ISO calibration certificate should list all measured values obtained during testing and calibration to confirm the device meets the applicable ISO standard(s). Each ISO calibration certificate is personalized for the customer; therefore, ISO calibration certificates are exempt from the right of return.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.pce-instruments.com\/f\/english\/media\/test-instruments-dakks-certificate-2016-11-22.pdf\" style=\"font-size: 0.875rem;\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/www.pce-instruments.com\/g\/custom\/category-pictures\/test-instruments-dakks.jpg\" alt=\"Sample DAkkS Calibration Certificate for Test Instruments\" class=\"img-responsive img-left\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eFo\u003cspan style=\"font-size: 0.875rem;\"\u003er e\u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003exampl\u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003ee, if a customer orders a digital dew point thermometer with an ISO calibration certificate, the thermometer is calibrated at two temperature points (e.g., -10°C \/ +14°F and +60°C \/ +140°F) according to the applicable ISO\u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003estandard. The calibration procedure is documented, and the customer receives a special test report including his\/her company name and address as well as a reference to the specific instrument used during testing and calibration.\u003ca name=\"locations\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eSome test instruments, such as scales and balances, are verified as legal for trade. If a scale or balance is verified as legal for trade, this important feature will be noted in the product description. The legal-for-trade designation applies mainly to commercial use when goods are valued and sold based on weight. The legal-for-trade verification must be renewed after a certain time period. Also, if the scale or balance ever needs repair, a re-verification must be performed on the instrument to ensure the proper level of accuracy is maintained.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","products":[{"product_id":"co2-analyzer-pce-aqd-10","title":"CO2 Air Quality Meter PCE-AQD 10","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003cstrong\u003eAir Quality\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e Meter\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003eCO2 datalogger for air quality testing \/ Adjustable storage rate \/  Backlit LCD \/ Storage on SD card \/ Storage as XLS\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv\u003eThe air quality meter is used to measure air quality. The air quality meter measures carbon dioxide, temperature and humidity. The CO2 sensor from the air quality meter is separated from the main unit with a connection cable. The measured values ​​are displayed on the large display of the air quality meter. The air quality meter data is stored on an SD card. The air quality meter can set the measured data in adjustable intervals of 1 ... 600 seconds.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eThe air quality meter is used to monitor indoor air quality in lounges, offices, schools, etc. Through the SD memory, the CO2 measurement data can be monitored over a long period of time to initiate further measures to improve the room air quality.\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Memory on SD card\u003cbr\u003e- 3 parameters of air quality\u003cbr\u003e- CO2, air temperature and humidity\u003cbr\u003e- Mains operation, A\/C power adapter\u003cbr\u003e- Save as XLS file\u003cbr\u003e- Large display with lighting\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasured variable CO2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0 ... 4000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e± 70 ppm (\u0026lt;1000 ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±5% of measured value (\u0026lt;3000ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±250 ppm (\u0026gt;3000 ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasured variable humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e10 ... 90 % RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 % RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(4% of measured value + 1 % RH) (\u0026gt;70% RH )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±4% RH (\u0026lt;70 % RH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasured variable temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0 ... 50 °C \/ 32 ... 122 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C \/ 0.18 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e± 0.8 °C \/ 1.4 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage rate\u003c\/td\u003e\n\u003ctd\u003e1, 2, 5, 10, 30, 60, 120, 300, 600 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eSD card up to 16 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD with lighting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefresh rate display\u003c\/td\u003e\n\u003ctd\u003e1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eplug-in power supply 9 V \/ 800 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating conditions\u003c\/td\u003e\n\u003ctd\u003e0 ... 50 °C \/ 32 ... 122 °F \/ \u0026lt; 85 % RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003emain unit: 132 x 80 x 32 mm \/ 5.2 x 3.1 x 1.3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCO2 sensor: 132 x 38 x 32 mm \/ 5.2 x 1.5 x 1.3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eca. 390 g \/ 13.7 oz (total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Air Quality Meter PCE-AQD 10\u003cbr\u003e1 x CO2 sensor\u003cbr\u003e1 x Mains power adapter\u003cbr\u003e1 x SD memory card\u003cbr\u003e2 x Wall holder\u003cbr\u003e1 x Adhesive pad\u003cbr\u003e1 x User manual\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding ISO Calibration","offer_id":48427048599781,"sku":"PCE-AQD 10","price":2260.0,"currency_code":"NZD","in_stock":true},{"title":"Including ISO Calibration","offer_id":48427048632549,"sku":"PCE-AQD 10-ICA","price":2480.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-air-quality-meter-pce-aqd-10-5999582_2807127.webp?v=1788142810"},{"product_id":"carbon-monoxide-meter-pce-wmm-50","title":"Carbon Monoxide Gas Detector PCE-WMM 50","description":"\u003cp\u003eThe PCE-WMM 50 consists of two parts: a sensor unit placed within the monitored area and a remote display unit positioned outside the exposure zone for safe monitoring. This system is commonly used in industries such as food processing, metalworking, chemical manufacturing, and waste management to protect workers from the harmful effects of CO\u003csub\u003e2\u003c\/sub\u003e, a colorless and odorless gas.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCO\u003csub\u003e2\u003c\/sub\u003e gas measurement range:\u003c\/strong\u003e 0 ... 50,000 ppm (5%)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature measurement range:\u003c\/strong\u003e 0 ... +45 ºC \/ +32 ... +113 ºF\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIP54-rated enclosure:\u003c\/strong\u003e Water-splash proof for both the sensor and remote display units\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTwo adjustable alarm thresholds:\u003c\/strong\u003e Ensures safe monitoring and response\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e3- to 4-digit remote display:\u003c\/strong\u003e Shows gas concentrations and temperature readings\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAlarm-activated potential-free contact:\u003c\/strong\u003e Automatically triggers external devices to control CO\u003csub\u003e2\u003c\/sub\u003e levels\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAudible and visual alarms:\u003c\/strong\u003e Ensures immediate awareness of high CO\u003csub\u003e2\u003c\/sub\u003e levels\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch6\u003eSpecifications\u003c\/h6\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCO\u003csub\u003e2\u003c\/sub\u003e Measurement Range:\u003c\/strong\u003e 0 ... 50,000 ppm (5%)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e 0 ... +45 ºC \/ +32 ... +113 ºF\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 100 ... 240 V AC, 50 \/ 60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e IP54-rated, splash-proof synthetic material\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 168 x 125 x 47 mm (6.62 x 4.93 x 1.85 inches) for the sensor unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery Scope:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x PCE-WMM 50 CO\u003csub\u003e2\u003c\/sub\u003e gas detector (sensor unit and remote display unit)\u003c\/li\u003e\n  \u003cli\u003e1 x User manual\u003c\/li\u003e\n\u003c\/ul\u003e\"\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":48427048861925,"sku":"PCE-WMM 50","price":1520.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-gas-detector-pce-wmm-50-517285_1179426.webp?v=1788142808"},{"product_id":"dust-measuring-device-pce-pqc-10-eu","title":"Particle Counter with ISO Calibration PCE-PQC 10 EU","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eDust Measuring Device PCE-PQC 1xEU series incl. calibration certificate\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eMeasurement of particle sizes up to 25 μm \/ Up to 6 parallel measuring channels \/ Internal memory \/ Reporting according to ISO 14644-1, EU GMP Annex I, FS 209E \/ Extrapolation of the mass concentration in μg \/ m³ \/ Ethernet, USB or (optional) Wifi connection\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv\u003eThe particle counters of the PCE-PQC 1xEU series measure the concentration of particles such as dust, soot, pollens and many other aerosols in the air. To accurately determine the degree of pollution of the air, the particle counters were developed. Pollution is mainly generated by combustion, material processing, manufacturing, power generation, vehicle engine emissions and the construction industry. With the help of the PCE-PQC 1xEU series particle counters the exact amount of dirt particles in the air can be measured.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003eOf greater importance is the degree of pollution of the air with pathogenic particles such as soot, which are released by the industry and especially by diesel vehicles without special filtering in the air. Such dispersion particles are responsible inter alia for reduced visibility, the inhalation of toxic substances and thus reduced labor productivity. It has also been known for some time that the particles also make a not inconsiderable contribution to many medical diseases such as asthma, bronchitis, skin and lung diseases. The particle counters are designed for easy and quick use. The particle counters of the PCE-PQC 1xEU series operate in different modes (real-time, cumulative, differential, mass concentration, ...) and display the results on the display.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Internal memory\u003cbr\u003e- Particle sizes up to 25 μm\u003cbr\u003e- Color display\u003cbr\u003e- Handy\u003cbr\u003e- 6 measuring channels\u003cbr\u003e- ISO 14644-1, EU GMP Annex I, FS 209E\u003cbr\u003e- Mass concentration\u003cbr\u003e- Ethernet, USB\u003cbr\u003e-\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIncl. temperature and humidity sensor\u003c\/strong\u003e\u003cbr\u003e- \u003cstrong\u003eIncl. calibration certificate traceable to NIST ISO 21501-4 and JIS B9921\u003c\/strong\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable cellspacing=\"0\" border=\"0\" bgcolor=\"#FFFFFF\"\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eMeasuring range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e\u003cspan\u003e0.3 ... 25 \u003c\/span\u003e\u003cspan\u003eμm\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eMeasuring channel sizes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eFactory calibrated at \u003cstrong\u003e0.3, 0.5, 1.0, 2.5, 5.0, 10.0 μm\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eCounting efficiency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e\u003cstrong\u003e50% at 0.3 μm 100% at \u0026gt; 0.45 μm\u003c\/strong\u003e according to JIS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eFlow\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e2.83 l \/ min (0.1 ft\u003csup\u003e3\u003c\/sup\u003e \/ min)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eRandom loss\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e5% at 4,000,000 particles \/ ft³\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eBattery\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e10 h\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eLight source\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eLong-life laser diode\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eZero count\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e\u0026lt; 1 count \/ 5 min (\u0026lt; 2 particles \/ ft³)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eAccording to ISO 21501-4 and JIS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eCounting modes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eAutomatic, manual, real-time, cumulative \/\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eDifferential, mass concentration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eAlarms\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e1 ... 9999999 counts, adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eCalibration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eTraceable to NIST\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e4.3\" WQVGA color touch display, 480x272 px\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003ePrinter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eExternal thermal printer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eAspiration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eInternal pump with automatic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eFlow control\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eAir outlet\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eInternal HEPA filter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eBattery pack\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eReplaceable Li-Ion battery\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eCharging time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eAbout 4 hours\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eReports\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eISO 14644-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eEU GMP Annex 1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eFS 209E\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eConfiguration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eMemory for 50 custom configurations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eStandards\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eISO 21501-4 and JIS B9921\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e25.4 x 12.9 x 11.4 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e1.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eStorage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e45000 data sets (ring memory) consisting of\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eParticle count, temp and humidity, locations and times\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eSample locations\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eUp to 1000 locations can be stored\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eSamples duration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e1 s ... 99 h adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003ePower supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e110 ... 240V AC 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eOperating conditions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cspan\u003e5 ... 40°C \/ 41 ... 104\u003c\/span\u003e°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eUp to 95% RH not condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eStorage conditions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cspan\u003e0 ... 50°C \/ 32 ... 122\u003c\/span\u003e°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eUp to 98% RH not condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" valign=\"top\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"1\" valign=\"top\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" valign=\"top\"\u003eTemp.-\/ Humidity sensor\u003c\/td\u003e\n\u003ctd rowspan=\"1\" valign=\"top\"\u003e0 ... +50 °C (32 ... +122 °F), 15 ... 90 % r.H.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" valign=\"top\"\u003eInternal\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" valign=\"top\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd rowspan=\"1\" valign=\"top\"\u003e0.5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd rowspan=\"1\" valign=\"top\"\u003e±0.5 °C (±1 °F), ±2 % r.H.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eInterface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e\u003cspan\u003eEthernet, USB\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eOptional interfaces\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eWiFi 802.11 b\/g, RS485 or RS232\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eNumber of measuring channels          \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e6\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Dust Measuring Device PCE-PQC 10EU\u003cbr\u003e\u003cstrong\u003e1 x Temperature and humidity sensor\u003c\/strong\u003e\u003cbr\u003e1 x Isokinetic probe\u003cbr\u003e1 x Cleaning filter\u003cbr\u003e\n\u003cdiv\u003e1 x Li-Ion rechargeable battery\u003cbr\u003e1 x Software for data download\u003cbr\u003e1 x USB cable\u003cbr\u003e1 x Power supply \/ battery charger\u003cbr\u003e1 x User manual\u003cbr\u003e\u003cstrong\u003e1 x Calibration certificate according to NIST\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":48427048960229,"sku":"PCE-PQC 10EU","price":9500.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-dust-measuring-device-pce-pqc-10eu-incl.-calibration-certificate-5946579_1503145_1.webp?v=1788142807"},{"product_id":"dust-measuring-device-pce-pqc-22-eu","title":"Particle Counter with ISO Calibration PCE-PQC 22 EU","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eDust Measuring Device PCE-PQC 2xEU series incl. calibration certificate\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eIncl. CO2 sensor \/ Large measuring range \/ PID sensor \/ 6 measuring channels \/ Factory calibrated \/ 2 models available\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv\u003eThe air quality monitor of the PCE-PQC 2xEU series measures particle sizes from 0.3 μm to 25 μm with mass concentration and additionally stores the parameters temperature, relative humidity, CO2 and TVOC (PCE-PQC 23EU only). This meter is the most versatile air quality monitor available with advanced power management and the industry's first sleep mode, enabling battery operation for periods that can exceed one month with a single charge. The PCE-PQC 2xEU series can be used as a stand-alone, battery-powered instrument or simply integrated into a building automation and plant monitoring system via Ethernet, USB. \u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eThe air quality monitor PCE-PQC 2xEU series can measure not only the measurement of particle sizes and mass concentrations but also the carbon dioxide content in the air. Furthermore, the air temperature and the relative humidity are measured. The air quality monitor PCE-PQC 23EU also has a photoionization detector (PID), which can be used for the measurement of volatile hydrocarbons (VOC's).\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- CO2 Sensor\u003cbr\u003e- Temperature and humidity measurement\u003cbr\u003e- Ethernet\u003cbr\u003e- USB\u003cbr\u003e- Wifi (optional)\u003cbr\u003e- \u003cstrong\u003eIncl. calibration certificate traceable to NIST ISO 21501-4 and JIS B9921\u003c\/strong\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable cellspacing=\"0\" border=\"0\" bgcolor=\"#FFFFFF\"\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eMeasuring range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0.3 ... 25 μm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eMeasuring channel sizes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eFactory calibrated at 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 μm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eCounting efficiency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e50% at 0.3 μm, 100% at \u0026gt; 0.45 μm according to JIS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eParticle mass display\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003ePM0.5, PM1.0, PM2.5, PM5.0, PM10 and TPM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eFlow\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e2.83 l \/ min (0.1 ft\u003csup\u003e3\u003c\/sup\u003e \/ min)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eRandom loss\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e5% at 4,000,000 particles \/ ft³\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eBattery\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e10 h\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eLight source\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eLong-life laser diode\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eZero count\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e\u0026lt;1 count \/ 5 min (\u0026lt;2 particles \/ ft3) according to ISO 21501-4 and JIS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eCounting modes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eAutomatic, manual, real-time, cumulative \/\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003edifferential, mass concentration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eAlarms\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e1 ... 9999999 counts, adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eCalibration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eTraceable to NIST\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e4.3\" WQVGA color touch display, 480x272 px\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003ePrinter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eExternal thermal printer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eAspiration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eInternal pump with automatic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eflow control\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eAir outlet\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eInternal HEPA filter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eBattery pack\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eReplaceable Li-Ion battery\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eCharging time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eAbout 4 hours\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eReports\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eISO 14644-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eEU GMP Annex 1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eFS 209E\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eConfiguration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eMemory for 50 custom configurations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eStandards\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eISO 21501-4 and JIS B9921\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e13.3 x 10.5 x 21 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e1.8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eStorage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e45000 data sets (ring memory) consisting of\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eParticle counting, temp. and humidity, CO2, (PID),\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eSample locations\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003ePlaces and times up to 1000 places can be deposited\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eSamples duration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e1 s ... 99 h adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003ePower supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e110 ... 240V AC 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eOperating conditions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e5 ... 40°C \/ 41 ... 104°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eUp to 95% RH not condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eStorage conditions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0 ... 50°C \/ 32 ... 122°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eUp to 98% RH not condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eCO2 sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eMeasuring range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0 ... 5000 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± 1% of measuring range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eTemp. \/ Humidity sensor intern  \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0 ... 50°C (32 ... 122°F), 15 ... 90% rh\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cspan\u003e0.5°C\u003c\/span\u003e \/ ± 0.9°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± 0.5°C \/ ± 0.9°F,  ± 2% RH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eInterface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eEthernet, USB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eOptional interfaces\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eWifi 802.11 b \/ g, RS485 or RS232\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eNumber of measuring channels       \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Dust Measuring Device PCE-PQC 22EU\u003cbr\u003e1 x Isokinetic probe\u003cbr\u003e1 x Temperature and humidity sensor\u003cbr\u003e1 x Cleaning filter\u003cbr\u003e1 x Li-Ion rechargeable battery\u003cbr\u003e1 x Software for data download\u003cbr\u003e1 x USB cable\u003cbr\u003e1 x Power supply \/ battery charger\u003cbr\u003e1 x User manual\u003cbr\u003e\u003cstrong\u003e1 x Calibration certificate according to NIST\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":48427049124069,"sku":"PCE-PQC 22EU","price":14230.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-dust-measuring-device-pce-pqc-22eu-incl.-calibration-certificate-5946611_1503310_9398edc2-f0ff-48f6-bce5-043469419d78.webp?v=1788142805"},{"product_id":"dew-point-thermometer-pce-320","title":"Dew Point Thermometer | Temperature \u0026 Humidity Measurement Device PCE-320","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eDew Point Thermometer \u003c\/span\u003e\u003cstrong\u003ePCE-320\u003cbr\u003eHumidity \/ Temperature \/ Dew point \/ Wet bulb globe temperature \/ Surface temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003eWith the dew point thermometer it is possible to measure climate conditions such as temperature and relative humidity, as well as determining surface temperature of objects simultaneously by using the included external temperature sensor or using an infrared measurement. The dew point thermometer offers features such as average value, maximum, minimum, and hold functions. The dew point thermometer provides additional information relating to dew point temperature and the global humidity temperature. Measurement values can be directly seen on the device's LCD display, and maximum and minimum values can be registered or transferred to a PC or portable computer for further analysis.\u003c\/p\u003e\n\u003cp align=\"justify\"\u003eThe dew point thermometer helps prevent damage to products, such as allowing for the elimination of fungus in food when being stored and during transportation. The dew point thermometer is also very useful in the construction industry, industrial sector, or in product development. Customers frequently complain about not having a tool available that can measure ambient conditions and surface temperature of a wall both inside and outside. The device can be sent away to be calibrated by an accredited DIN ISO laboratory. We offer the possibility of ISO calibration from factory (when the device is ordered or as an annual recalibration).\u003c\/p\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Backlit LCD\u003cbr\u003e- Measures ambient humidity and temperature using an internal sensor\u003cbr\u003e- Measures surface temperature using an optional external sensor\u003cbr\u003e- Infrared measurement of a material temperature\u003cbr\u003e- Display shows temperature and humidity simultaneously\u003cbr\u003e- Determines dew point and global humidity temperature\u003cbr\u003e- Average value, Maximum, Minimum and Hold functions\u003cbr\u003e- Auto shut-off to protect battery life\u003cbr\u003e- Software for data transmission included\u003cbr\u003e- Optional ISO calibration certificate available\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable cellpadding=\"1\" cellspacing=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e\u003cstrong\u003eInternal probe\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eTemperature\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e-20º... 60°C \/ -4 ... 140°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eRelative humidity\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e10 ... 90% H.r.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eTemperature of global\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e-21.6 ... 60°C \/ -6.8 ... 140°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eHumidity\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e-68 ... 60°C \/ -90.4 ... 140°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eDew point temperature\u003c\/td\u003e\n\u003ctd align=\"center\"\u003edepending on the sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e\u003cstrong\u003eExternal\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eTemperature\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e-50 ... 500°C \/ -58 ... 932°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e\u003cstrong\u003eInfrared\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eTemperature resolution\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0.1°C \/ 0.18°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eRelative humidity resolution\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e\u003cstrong\u003eAccuracy (Internal)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eTemperature\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e± 1.0°C \/ 1.8°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eRelative humidity\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e± 3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eWet bulb temperature\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e± 1.0°C \/ 1.8°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eDew point temperature\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e± 1.0°C \/ 1.8°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e\u003cstrong\u003eAccuracy (External)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eTemperature\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e± 1% ± 1.0° C \/ 1.8°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e\u003cstrong\u003eInfrared\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003e-50 ... -20ºC \/ -58 ... -4ºF\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e± 5.0°C \/ 9°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003e-20 ... 500ºC \/ -4 ... 932ºF\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e± 2.0°C \/ 33.6°F  o ± 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eResponse time\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u0026lt; 4 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eHumidity sensor type\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eResistance sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eSoftware\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eFrom Windows 98\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eMemory\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eMaximum and minimum value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eExternal temperature sensor\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e1 m \/ (3.3 ft) long hot wire sensor and many other available to order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eDisplay\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eMultiple LCD for diplaying a variety of different readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003ePower\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e9V battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eOperating conditions\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e-20 ... 60°C \/ -4 ... 140°F\u003cbr\u003e0 ... 90% H.r.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eDimensions\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e257 x 76 x 53 mm \/ 10.1 x 2.9 x 2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eWeight\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e355 g \/ \u0026lt; 1 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cp align=\"justify\"\u003e1 x Dew Point Thermometer PCE-320\u003cbr\u003e1 x External temperature sensor\u003cbr\u003e1 x Software and data cable\u003cbr\u003e1 x 9V battery\u003cbr\u003e1 x User's manual\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding ISO Calibration","offer_id":48427049287909,"sku":"PCE-320","price":1090.0,"currency_code":"NZD","in_stock":true},{"title":"Including ISO Calibration","offer_id":48427049320677,"sku":"PCE-320-ICA","price":1620.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-dew-point-thermometer-pce-320-ica-incl.-iso-calibration-certificate-6046924_2271347.webp?v=1788142804"},{"product_id":"dew-point-thermometer-pce-thb-38","title":"Dew Point Meter PCE-THB 38","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eMulti-function PCE-THB 38 D\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003eew point thermometer\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e incl. ISO calibration certificate\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e(\u003cstrong\u003eThermometer, Humidity Meter and Hygrometer all in one device)\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe PCE-THB 38 dew point thermometer is ideal for detecting and digitally displaying humidity, temperature and barometric pressure. Temperature is measured by an RTD sensor and air humidity is measured by a highly repeatable, capacitive sensor. The dew point thermometer also calculates dew point and atmospheric pressure in a range of 10 to 1100 hPa. With all of these features, it is a complete climatological device. It is shipped from the manufacturer already calibrated. Otherwise, a laboratory calibration and certificate can be ordered which meets ISO calibration standards.\u003c\/p\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e- Measures temperature, humidity and barometric pressure\u003cbr\u003e- Calculates dew point\u003cbr\u003e- Selectable pressure units: hPa, (mbar), mmHg and inHg\u003cbr\u003e- Battery level indicator\u003cbr\u003e- Minimum, maximum and hold functions\u003cbr\u003e- Protected internal sensor\u003cbr\u003e- Good price\u003cbr\u003e- Light weight\u003cbr\u003e- Easy to use\u003cbr\u003e- Durable enclosure\u003cbr\u003e- Highly accurate measurements\u003cbr\u003e-\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eIncl. ISO calibration certificate\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e     \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"209\"\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement ranges\u003c\/strong\u003e\u003cbr\u003e-Temperature\u003cbr\u003e-Relative air humidity\u003cbr\u003e-Barrometric pressure\u003cbr\u003e-Dew point temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\" align=\"center\"\u003e\n\u003cdiv align=\"left\"\u003e\n\u003cbr\u003e0 ... 50°C \/ 32 ... 122°F\u003cbr\u003e10 ... 95% r.h.\u003cbr\u003e10 ... 1100 hPa (mbar)\u003cbr\u003e-25 ... 49°C \/ -20.2 ... 120.2°F\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"209\"\u003e\n\u003cp\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003cbr\u003e-Temperature\u003cbr\u003e-Relative air humidity\u003cbr\u003e-Barrometric pressure\u003cbr\u003e-Dew point temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\" align=\"center\"\u003e\n\u003cdiv align=\"left\"\u003e\n\u003cbr\u003e0.1ºC \/ 0.18ºF\u003cbr\u003e0.1% r.h.\u003cbr\u003e0.1 hPa ... 1000 hPa (but 1 hPa)\u003cbr\u003e0.01ºC \/ 0.018ºF\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"209\"\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003cbr\u003e-Temperature\u003cbr\u003e-Relative air humidity\u003cbr\u003e\u003cbr\u003e-Barrometric pressure\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\" align=\"center\"\u003e\n\u003cdiv align=\"left\"\u003e\n\u003cbr\u003e± 0.8°C \/ ± 1.4°F\u003cbr\u003e± 3% of reading or ± 1%\u003cbr\u003e(\u0026lt;70% r.h., but ± 3% r.h.)\u003cbr\u003e± 1.5 hPa to 1000 hPa, but ± 2 hPa\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"209\"\u003e\n\u003cp\u003eOperating temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"384\" align=\"center\"\u003e\n\u003cdiv align=\"left\"\u003e0 ... 50ºC \/ 32 ... 122°F\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"209\"\u003ePower\u003c\/td\u003e\n\u003ctd width=\"384\" align=\"center\"\u003e\n\u003cdiv align=\"left\"\u003e4 AAA batteries\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"209\"\u003eDimensions\u003c\/td\u003e\n\u003ctd width=\"384\" align=\"center\"\u003e\n\u003cdiv align=\"left\"\u003e120 x 40 mm \/ 4.7 x 1.5 in\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"209\"\u003eWeight (with batteries)\u003c\/td\u003e\n\u003ctd width=\"384\" align=\"center\"\u003e\n\u003cdiv align=\"left\"\u003e160 g \/ \u0026lt; 1 lb\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e1 x PCE-THB 38 \u003cspan\u003edew point thermometer\u003c\/span\u003e\u003cbr\u003e4 x Batteries\u003cbr\u003e1 x User's manual\u003cbr\u003e\u003cstrong\u003e1 x ISO calibration certificate\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding ISO Calibration","offer_id":48427049746661,"sku":"PCE-THB 38","price":690.0,"currency_code":"NZD","in_stock":true},{"title":"Including ISO Calibration","offer_id":48427049779429,"sku":"PCE-THB 38-ICA","price":1130.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-dew-point-thermometer-pce-thb-38-ica-incl.-iso-calibration-certificate-5886231_1236891.webp?v=1788142802"},{"product_id":"digital-thermometer-pce-thb-40","title":"Indoor Climate Thermo-Hygrometer PCE-THB 40","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eHVAC Meter with SD memory card\u003c\/strong\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u0026amp; ISO Calibration Certificate\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(max. 16 GB SDHC) \/ large LCD display \/ different units can be selected \/ battery or\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003emains operation (optional) possible\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\nThe HVAC meter records the air temperature as well as the relative humidity and the barometric pressure and saves them internally on an SD card. The compact device with a large memory (up to max. 16 GB SDHC card) is primarily used for long-term registration in the food sector (refrigerated counters in department stores, refrigerated transports, warehouses) and for measurement and recording in industry (heating and cooling processes, machine temperatures, product storage). The current measured value is shown directly on the LCD display and is also stored in the data memory so that the value can either be read off directly or the values ​​stored on the SD card can be transferred to a PC or laptop as desired and evaluated graphically as a progression curve.\u003cbr\u003e\u003cbr\u003eThe values ​​recorded in the data logger function can of course also be transferred back to the PC and evaluated (.xls file on the SD card). You can also check the columns of numbers for outliers and, in the case of the food industry, quickly see whether and, if so, how long the cold chain was interrupted. The internal real-time clock with date allows the user to precisely assign the events. The measuring rate is freely adjustable. The electronics of the data logger are protected against impacts and robust handling in industry.\u003cbr\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Measures temperature, humidity, barometric pressure\u003cbr\u003e- Flexible internal real-time data storage via SD memory card (1 ... 16GB)\u003cbr\u003e- The saved data is saved directly as an Excel file on the SD card\u003cbr\u003e- Selectable pressure unit: hPa, mmHg and inHg\u003cbr\u003e- Low battery display\u003cbr\u003e- Large LCD display\u003cbr\u003e- Adjustable measuring rate\u003cbr\u003e- Easy to use\u003cbr\u003e- Robust housing\u003cbr\u003e- Optional software kit for online transfer to a PC or laptop (no software is required to evaluate the stored data)\u003cbr\u003e-\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eincl. ISO Calibration Certificate\u003c\/strong\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0 ... 50°C \/ 32 ... 122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity in air    \u003c\/td\u003e\n\u003ctd\u003e10 ... 90% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometric pressure\u003c\/td\u003e\n\u003ctd\u003e10 ... 1100 hPa \/ 7.5 ... 825 mmHg \/ 0.29 ... 32.48 inHg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.18°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity in air\u003c\/td\u003e\n\u003ctd\u003e0.1% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometric pressure\u003c\/td\u003e\n\u003ctd\u003e0.1 hPa: 10 ... 1000 hPa, 1 hPa: 1001 ... 1100 hPa \/ 0.1 mmHg \/ 0.01 inHg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e± 0.8°C \/ ± 1.4°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity in air\u003c\/td\u003e\n\u003ctd\u003e± 4% RH: \u0026lt; 70% RH\u003cbr\u003e± ( 4% reading + 1% RH): ≥ 70% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometric pressure\u003c\/td\u003e\n\u003ctd\u003e± 2 hPa: 10 ... 1000 hPa, ± 3 hPa: 1001 ... 1100 hPa \/ ± 1.5 mmHg \/ ± 0.1 inHg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling interval\u003c\/td\u003e\n\u003ctd\u003e5,10, 30, 60, 120, 300 or 600 seconds, or automatic (it stores data when there is an alteration of the value of ± 1º, ±1 % RH or ± 1 hPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eSD card memory up to 16 GB (an SD card is included in the delivery contents)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0 ... 50ºC \/ 32 ... 122ºF\u003cbr\u003e\u0026lt; 90% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e6 x 1.5V AAA batteries or\u003cbr\u003e1 x 9V electric power supply (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e132 mm x 80 mm x 32 mm \/ 5.1 in x 3.1 in x 1.3 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (with batteries)\u003c\/td\u003e\n\u003ctd\u003e285 g \/ \u0026lt; 1 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cp\u003e1 x HVAC Meter PCE-THB 40-ICA\u003cbr\u003e1 x SD card\u003cbr\u003e1 x Wall mounting kit\u003cbr\u003e6 x Batteries\u003cbr\u003e1 x User manual\u003cbr\u003e1 x ISO calibration certificate\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding ISO Calibration","offer_id":48427050074341,"sku":"PCE-THB 40","price":900.0,"currency_code":"NZD","in_stock":true},{"title":"Including ISO Calibration","offer_id":48427050107109,"sku":"PCE-THB 40-ICA","price":1360.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-hvac-meter-pce-thb-40-ica-incl.-iso-calibration-certificate-5953695_1585362.webp?v=1788142801"},{"product_id":"infrared-thermometer-pce-ir-90","title":"Infrared Thermometer PCE-IR 90","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eFood Infrared Thermometer with Bluetooth interface \/ Measuring range -40 ... 300°C (-40 ... 572\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e°F\u003c\/strong\u003e)\u003c\/span\u003e\u003cstrong\u003e \/ Charging station \/ penetration temperature probe for checking the core temperature \/ Background lighting \/ Temperature indicator display \/ Stop watch \/ Emissivity 0.95\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv\u003eThe food infrared thermometer is used to check the temperature of food. In addition to the surface temperature via the infrared sensor, the thermometer can also be used to determine the core temperature via the fold-out resistance temperature sensor. Both temperature sensors on the thermometer have a measuring range of -40 ... 300°C \/ -40 ... 572°F.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eIn addition to the normal measured value display, the thermometer has a temperature display. This display on the thermometer signals whether the temperature of the food being measured is optimal. If the temperature is between 4 … 65°C \/ 39.2 ... 149°F, this is indicated by a red LED. If the temperature is colder than 4°C \/ 39.2°F or warmer than 65°C \/ 149°F, this is indicated by a green LED. This function in the thermometer is particularly important in order to monitor the respective temperature chain. Therefore, the thermometer is used especially in the food industry.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eThe Bluetooth interface enables communication between the thermometer and a mobile Android and iOS device. With the free app for the thermometer, the measured values ​​can be recorded with a mobile device and exported for later analysis. To charge the measuring device, the thermometer can be plugged into the charging station provided. If necessary, the thermometer can also be charged via a 5 V micro USB interface.\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Measuring range -40 ... 300°C \/ -40 ... 572°F\u003cbr\u003e- Infrared and penetration temperature sensor\u003cbr\u003e- Timer and stopwatch function\u003cbr\u003e- Charging station with micro USB cable\u003cbr\u003e-\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBluetooth interface\u003c\/strong\u003e\u003cbr\u003e- Mobile temperature measuring device\u003cbr\u003e- Easy handling\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable border=\"0\" bgcolor=\"#FFFFFF\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eInfrared measurement\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eMeasuring range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e-40 ... 300°C, -40 ... 572°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0.1°C, °F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eMeasurement accuracy        \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± 1°C, ± 1.8°F at 0 ... 65°C, 32 ... 150°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± 2.5°C, ± 4.5°F at \u0026lt; 0°C, \u0026lt; 32 ° F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± 1.5% at \u0026gt; 65°C, 150°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eSpot ratio\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e2: 1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eReaction time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e\u0026lt; 500 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003ePenetration probe\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eMeasuring range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e-40 ... 300°C, -40 ... 572°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0.1° C,°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eMeasurement accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± 1°C, ± 1.8°F at -40 ... 200°C, -40 ... 392°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± 1.5°C, ± 4.5°F at \u0026gt; 200°C, \u0026gt; 392°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eSensor type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eResistance temperature sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eProbe length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e100 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eFurther specifications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eEmission value\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0.95 fixed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eInterfaces\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eBluetooth (data transfer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eMicro USB (for charging)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eAdditional functions      \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eTimer and stopwatch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003ePower supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e4.2V 1300-mAh battery,\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e5V DC \/ 1 A fixed voltage supply via\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eMicro USB interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eOperating conditions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0 ... 50°C, \u0026lt; 85% RH, non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e176 x 55 x 40 mm \/ 6.9 x 2.2 x 1.6 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e185 g \/ \u0026lt; 1 lb\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Food infrared thermometer PCE-IR 90-ICA\u003cbr\u003e1 x Micro USB charging cable\u003cbr\u003e1 x Charging station\u003cbr\u003e1 x Transport bag\u003cbr\u003e1 x Operating instructions\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding ISO Calibration","offer_id":48427050139877,"sku":"PCE-IR 90","price":510.0,"currency_code":"NZD","in_stock":true},{"title":"Including ISO Calibration","offer_id":48427050172645,"sku":"PCE-IR 90-ICA","price":770.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-food-infrared-thermometer-pce-ir-90-ica-incl.-iso-calibration-certificate-6115379_2794259_c60cc4f9-554c-46c0-bdf1-7e8fc9d569e5.webp?v=1788142799"},{"product_id":"contact-thermometer-pce-t390","title":"Digital Contact Thermometer PCE-T 390","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003eContact Thermometer PCE-T390\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eType-K, J and PT100 temperature sensor inputs \/ Data logger function (xls format) \/ SD card slot\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003elarge LC display \/ Power supply via batteries or mains adaptor \/ \u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eThe PCE-T390 Contact Thermometer is a digital device with four input channels for type K and type J temperature sensors and two input channels for PT100 temperature sensors. The PCE-T390 Contact Thermometer has a SD card slot (from 1 ... 16 GB) for storing the measured data. The data is stored in xls format on the SD card of the contact thermometer so that no additional software is needed for further analysis. However, there is an optional software kit available for the PCE-T390 Contact Thermometer, which comes with a RS-232 cable and enables you to transfer the data to a PC and analyse it in real-time without having to remove the SD card. The sampling intervals of the data logger function can be set freely in the settings of the contact thermometer. The display of the PCE-T390 contact thermometer shows the temperatures of all four channels simultaneously (when there are sensors connected). The PCE-T390 contact thermometer can be used as a handheld device in situ or as a data logger for monitoring temperature fluctuations over a certain period of time. The contact thermometer can be used for a large variety of applications, for example in the field of maintenance, conservation, machine diagnostics and quality control. The device is also available with an optional ISO calibration certificate.\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e- 4 input channels for type-K, J temperature sensors\u003cbr\u003e- 2 input channels for Pt100 temperature sensors\u003cbr\u003e- 2 x type-K temperature sensors are included in the package\u003cbr\u003e- SD card memory (1 ... 16 GB)\u003c\/div\u003e\n\u003cdiv\u003e- Data logger function\u003cbr\u003e- Backlit LCD\u003cbr\u003e- Auto power-off function\u003cbr\u003e- Display shows data from 4 channels simultaneously\u003cbr\u003e- RS-232 interface for data transfer\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range meter\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eType K: -100 ... 1370°C \/ -148 ... 2498°F\u003cbr\u003eType J: -100 ... 1150°C \/ -148 ... 2102°F\u003cbr\u003ePt100: -200 ... 850°C \/ -328 ... 1562°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTFype K: 0.1°C \/ 0.18°F (-100 ... 1000°C \/ -148 ... 1832°F); 1°C \/ 1.8°F  (1000 ... 1370°C \/ 1832 ... 2498°F )\u003cbr\u003eType J: 0.1°C \/ 0.18°F (-100 ... 1000°C \/ -148 ... 1832°F); 1°C \/ 1.8°F (1000 ... 1150°C \/ 1832°F ... 2102°F)\u003cbr\u003ePt100: 0.1°C \/ 0.18°F (-200 ... 850°C \/ -328 ... 1562°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (at 23°C \/ 73.4°F, ±5°C \/ 41°F)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(0.4% + 1°C \/ 1.8°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling interval\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 ... 3600 seconds (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor inputs\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e4 x type K\/J sensor inputs, 2 x Pt100 sensor inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eSD card memory (1 ... 16 GB SD cards are supported)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC software requirements (optional)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWindows 95 or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e52 x 38 mm \/ 2 x 1.5 in LCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6 x 1.5V AA batteries\u003cbr\u003e9V mains adaptor (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto power-off function\u003c\/td\u003e\n\u003ctd\u003eAfter 30 min of idle time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental conditions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 ... 50°C \/ 32 ... 122°F, \u0026lt; 85% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e177 x 68 x 45 mm \/ 7 x 2.7 x 1.8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e278 g \/ \u0026lt; 1 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e1 x Contact thermometer PCE-T390 \u003c\/div\u003e\n\u003cdiv\u003e2 x Type-K sensors TF-500 \u003cbr\u003e6 x 1.5V AA batteries \u003cbr\u003e1 x SD memory card\u003cbr\u003e1 x Instruction manual\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding ISO Calibration","offer_id":48427050893541,"sku":"PCE-T390","price":910.0,"currency_code":"NZD","in_stock":true},{"title":"Including ISO Calibration","offer_id":48427050926309,"sku":"PCE-T390-ICA","price":1060.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/cc_eaa2dc3d-d601-475f-b739-e8dad921e3c0.webp?v=1788142797"},{"product_id":"temperature-meter-pce-t312n","title":"Digital Temperature Indicator PCE-T312N","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eTemperature Meter incl. ISO Calibration Certificate\u003cbr\u003e2-channel digital temperature measuring device with dual input \/ Large temperature range \/ Readings in °C, °F or Kelvin \/ Automatic shutdown \/ One hand operation \/ Backlight \/ For thermocouples Type K and Type J\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003eThe temperature meter is a two-channel measuring instrument. The digital temperature measuring device offers possibilities for a multitude of measuring projects. Due to its compact dimensions and its power supply, the digital temperature measuring device can be used with a mobile battery, making it suitable for applications such as air conditioning, food production and food storage, agriculture, chemicals and industry. The large measuring range offers a wide range of application possibilities, since in addition to the electronic zero offset, a temperature measuring range of -210 ... 1372°C \/ -346 ... 2501°F is possible.\u003cbr\u003e\u003cbr\u003eThe digital temperature gauge offers different display functions. In addition to the temperature data, this also includes the extreme value functions (MAX and MIN), as well as the calculation of the average temperature. Indicated measuring units of the digital temperature measuring device are °C, °F and Kelvin. The user can switch between them as required. The digital temperature meter provides one-handed operation and provides backlighting for optimal reading.\u003cbr\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- K-type thermometer with dual input\u003cbr\u003e- Temperature range: -210 ... 1372°C \/ -346 ... 2501°F\u003cbr\u003e- Direct measurement \/ differential measurement (T1-T2)\u003cbr\u003e- Electronic zero offset\u003cbr\u003e- Readings in °C, °F or Kelvin (K)\u003cbr\u003e- Automatic switch-off after 20 minutes of inactivity\u003cbr\u003e-\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eincl. ISO Calibration Certificate\u003c\/strong\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"294\" valign=\"top\"\u003eThermocouple types\u003c\/td\u003e\n\u003ctd width=\"271\" valign=\"top\"\u003eType K and Type J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range thermocouple Type K\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-200 ... 1372 °C \/ -328 ... 2501 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range thermocouple Type J\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-210 ... 1100 °C \/ -346 ... 2012 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasurement units\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e°C \/ °F \/ K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDisplay\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eLarge, dual LCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDisplay functions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eT1, T2, T1-T2, MAX, MIN, AVG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePower supply\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e3 x 1.5V AAA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAutomatic shutdown\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eAfter 20 minutes of inactivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eTemperature accuracy over –100ºC (148ºF)\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e± [0.15% of reading +1 °C (1.8 °F)]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eTemperature accuracy under –100ºC (148ºF)\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e± [0.5% of reading +2 °C (3.6 °F)]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eTemperature accuracy T1-T2\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e± [0.5% of reading +1 °C (1.8 °F)]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0 ... 50 °C (4 ... 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e10 ... 50 °C (14 ... 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eOptional Accessories\u003c\/h1\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/Screenshot_2025-04-01_111525.png?v=1743459405\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch1 class=\"headline\"\u003e\u003cbr\u003e\u003c\/h1\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Temperature Meter PCE-T312N-ICA\u003cbr\u003e2 x TF-500 Thermo-wire sensor\u003cbr\u003e3 x 1.5V AAA batteries\u003cbr\u003e1 x User manual\u003cbr\u003e1 x ISO Calibration Certificate\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch6\u003eDownloads\u003c\/h6\u003e\n\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding ISO Calibration","offer_id":48427051417829,"sku":"PCE-T312N","price":490.0,"currency_code":"NZD","in_stock":true},{"title":"Including ISO Calibration","offer_id":48427051450597,"sku":"PCE-T312N-ICA","price":670.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-temperature-meter-pce-t312n-ica-incl.-iso-calibration-certificate-5955395_1604503_1.webp?v=1788142796"},{"product_id":"moisture-meter-pce-mmk-1","title":"Multifunction Material Moisture Meter PCE-MMK 1","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cp align=\"center\"\u003e\u003cstrong\u003eMultifunction Moisture Meter\u003cbr\u003eMeasures moisture content of wood, paper, textiles, concrete and other building materials - also measures ambient temperature and relative humidity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003ePCE-MMK 1 is a portable handheld digital moisture meter used to measure the moisture content of wood, paper, textiles, concrete and other building materials. This multifunction moisture meter also measures ambient temperature and ambient relative humidity.\u003c\/p\u003e\n\u003cp\u003eIdeal for quality control and incoming goods inspections, this multipurpose moisture analyzer comes with short and long insertion needles as well as 3 different external electrodes (ramming, penetrating, paper). Self-test or pre-set measuring modes based on material type are available from the user friendly navigation menu, as are temperature compensation, maximum \/ minimum value, LCD backlight and dry-moist-wet indicator settings. An easy-to-read display shows digital and bar graph values on screen. Moisture % displayed is material moisture with respect to dry mass (e.g., 100 % material moisture for 1 kg of wet wood = 500 g water).\u003c\/p\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Measures moisture content of wood, paper, textiles, concrete and other building materials\u003cbr\u003e- Also measures ambient temperature and ambient relative humidity\u003cbr\u003e- Measuring principle: Electrical resistance\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable border=\"0\" bgcolor=\"#FFFFFF\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring ranges\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eWood, paper, textiles: 1 ... 75% moisture\u003cbr\u003eConcrete, building materials: 0.1 ... 2.4% moisture\u003cbr\u003eAmbient temperature: -40 ... 70°C \/ -40 ... 158°F\u003cbr\u003eAmbient relative humidity (RH): 0 ... 100% RH\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eWood, paper, textiles: 1 ... 30% \/ ±1%, 31 ... 60% \/ ±2%, 61 ... 75% \/ ±4%\u003cbr\u003eConcrete, building materials: ±0.5%\u003cbr\u003eAmbient temperature: -40 ... -10°C and 40 ... 70 °C \/ ±2°C, -10 ... 40°C \/ ±1°C\u003cbr\u003eAmbient relative humidity (RH): 0 ... 20 % and 80 ... 100% \/ ±5%, 20 ... 80% \/ ±3.5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAutomatic power off\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eAfter 3 minutes of inactivity, meter powers off to save battery\u003cbr\u003eAfter 10 seconds of inactivity, LCD backlight powers off to save battery\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eImpact-resistant plastic housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eBattery\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e3 x Cr 2032, replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating conditions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0 ... 40°C \/ 32 ... 104°F, 0 ... 85% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e139 x 47 x 25 mm \/ 5.5 x 1.9 x 1.0 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e100 g \/ \u0026lt; 1 lb  (without electrodes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x PCE-MMK 1 multifunction moisture meter\u003cbr\u003e2 x 30 mm \/ 1.18 in insertion needles\u003cbr\u003e2 x 150 mm \/ 5.91 in insertion needles\u003cbr\u003e1 x Cap to connect external electrodes\u003cbr\u003e1 x Ramming electrode\u003cbr\u003e1 x Penetrating electrode\u003cbr\u003e1 x Paper electrode\u003cbr\u003e1 x Self-test probe\u003cbr\u003e2 x 300 mm \/ 11.81 in extensions\u003cbr\u003e1 x User manual\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":48427051778277,"sku":"PCE-MMK 1","price":1540.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-multifunction-moisture-meter-pce-mmk-1-270994_1057495_1.webp?v=1788142791"},{"product_id":"timber-moisture-meter-pce-wmh-3","title":"Wood Moisture Meter PCE-WMH 3","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cp align=\"center\"\u003e\u003cstrong\u003ePCE-WMH-3 Wood Moisture Analyzer\u003cbr\u003eFeatures preset characteristic curves for measuring 270 different wood types\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003ePCE-WMH-3 is a portable handheld digital moisture analyzer used to measure the moisture content of wood. This hammer-style wood moisture analyzer features preset characteristic curves for measuring moisture in 270 different wood types.\u003c\/p\u003e\n\u003cp\u003eA table of exotic wood type coefficient values is provided in the user manual to allow for proper calculation. The table lists coefficient values for exotic wood types including but not limited to Gonzales Alves, Pine, Brazilian-Rosewood, Chipboard, Cedar, Dogwood, European Aspen, Elm, Oak, Juniper, Maple, Ash, Quebracho Blanco and Colorado, Sandalwood, Mahagony, Olive, Umbrella, Pear, Persimmon, African Walnut, Teak, Willow and more.\u003c\/p\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Delivers moisture content measurements in seconds\u003cbr\u003e- Preset characteristic curves for 270 wood types\u003cbr\u003e- Automatic temperature compensation\u003cbr\u003e- Compact, handheld, portable\u003cbr\u003e- Easy-to-read LCD screen\u003cbr\u003e- No preparation required\u003cbr\u003e- Battery powered\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e6 ... 60 % moisture content\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % (within 6 ... 12 % range), ±2 % (13 ... 28 %), ±2 %(29 ... 60 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of different wood types\u003c\/td\u003e\n\u003ctd\u003e270\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWood temperature range\u003c\/td\u003e\n\u003ctd\u003e-10 ... +60 ºC \/ 14 ... 140 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode dimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 3.5 x 12 mm \/ 0.1 x 0.4\", 2.5 x 8 mm \/ 0.09 x 0.3\", 2 x 6 mm \/ 0.07 x 0.2\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e1 x 12V 23A battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003eApprox. 10000 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit dimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 180 x 80 x 42 mm \/ 7 x 3.1 x 1.6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit weight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.8 kg \/ 1.77 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x PCE-WMH-3 wood moisture analyzer\u003cbr\u003e1 x pair of electrodes\u003cbr\u003e1 x replacement pair of electrodes\u003cbr\u003e1 x battery\u003cbr\u003e1 x user manual\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":48427051876581,"sku":"PCE-WMH-3","price":1910.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-timber-moisture-meter-pce-wmh-3-313124_584246_1.webp?v=1788142790"},{"product_id":"timber-moisture-meter-pce-pmi-1bt","title":"Wood Moisture Meter PCE-PMI 1BT","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eDamp meter with Bluetooth interface \/ Measuring range 0.0 ... 100.0% \/\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eSmall and compact design \/ Data export in .csv, .pdf, .jpg \/ Battery operation \/\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eFor determining the moisture on various materials\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv align=\"justify\"\u003eThe damp meter has a measuring range of 0.0…. 100.0%. For a measurement, the ball head is positioned on the test object by the moisture meter. This guarantees a non-destructive measurement with the moisture meter. The moisture meter is therefore used, for example, for on-site inspections of buildings, wood and other surfaces.\u003cbr\u003e\u003cbr\u003eA connection can be established with the damp meter via the free app. As soon as a connection has been established, the current measured value is displayed by the moisture meter. The recorded data can be exported as .csv and .pdf after a measurement. This means that the data measured by the moisture meter can be processed further.\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- For moisture determination\u003cbr\u003e- Measuring range 0.0 ... 100.0%\u003cbr\u003e- Free Android and iOS app\u003cbr\u003e- Bluetooth interface\u003cbr\u003e- Small and compact design\u003cbr\u003e- Universally applicable\u003cbr\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.0 ... 100.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring rate\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e2 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring depth\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e20 ... 40 mm \/ 0.78 ... 1.57\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eInterface\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eBluetooth 4.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring principle\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003ecapacitive (electrical resistance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eSensor type\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003emetal spheroid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePower supply\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e2 x 1.5 V AAA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating conditions  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0 ... 50 °C \/ 32 ... 122 °F, \u0026lt;90% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e160 x 33 x 20 mm \/ 6.3 x 1.3 x 0.7\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e93 g \/ 3.2 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Damp Meter PCE-PMI 1BT\u003cbr\u003e2 x 1.5 V AAA batteries\u003cbr\u003e1 x Instruction manual\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe \u003cstrong\u003ePCE-PMI 1BT Timber Moisture Meter\u003c\/strong\u003e is designed for nondestructive moisture measurements in wood, timber, and other surfaces. With a Bluetooth interface and compact design, this moisture meter allows real-time data transmission via a free Android or iOS app.\u003c\/p\u003e\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasuring range: 0.0 ... 100.0%\u003c\/li\u003e\n\u003cli\u003eBluetooth interface for data transmission\u003c\/li\u003e\n\u003cli\u003eNon-invasive, nondestructive moisture measurement\u003c\/li\u003e\n\u003cli\u003eData export in .csv and .pdf formats\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003eSpecifications\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring Depth:\u003c\/strong\u003e 20 ... 40 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 2 x 1.5V AAA batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 160 x 33 x 20 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 93 g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDelivery Scope:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x PCE-PMI 1BT Timber Moisture Meter\u003c\/li\u003e\n\u003cli\u003e2 x 1.5V AAA Batteries\u003c\/li\u003e\n\u003cli\u003e1 x Instruction Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":48427052007653,"sku":"PCE-PMI 1BT","price":520.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-timber-moisture-meter-pce-pmi-1bt-5980479_1777487.webp?v=1788142788"},{"product_id":"wall-moisture-meter-pce-pmi-4","title":"Salt Water Pool pH \u0026 Chlorine Test Kit PCE-PH 16-TUM 20-CM 41-KIT","description":"\u003cp\u003eThe \u003cstrong\u003ePCE-PMI 4 Wall Moisture Meter\u003c\/strong\u003e is a nondestructive device designed for detecting moisture in walls, plaster, concrete, and other building materials. With a penetration depth of up to 50 mm, this meter ensures accurate moisture measurement without damaging the material.\u003c\/p\u003e\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNon-invasive moisture detection\u003c\/li\u003e\n\u003cli\u003ePenetration depth of up to 50 mm\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eSalt Water Swimming Pool pH Meter Kit PCE-PH 16-TUM 20-CM ​​41-KIT\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003epH meter \/ Turbidity meter \/ Conductivity meter \/ Easy operation of various parameters \u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv\u003eA neutral pH value is a basic requirement for good water quality in swimming pools and pools. If the pH value of the water is incorrect, this can lead to skin and eye irritation, among other things. Regular checks of the pool water for its pH value are therefore essential. This is particularly easy, precise and comfortable with the user-friendly pool pH meter from PCE Instruments, which is suitable for use in swimming pools and pools. With an accuracy of ± 0.1 pH and a resolution of 0.01 pH, exact measurements can be made with the Pool pH meter. Failure to regularly check the pH value with the pool pH meter can damage fittings and other metallic materials. An inadequate pH value also has an impaired effect of the pool chemicals.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003eUsing the pool pH meter makes determining the pH value particularly easy. In order to carry out a measurement with the pool pH meter, the protective cap of the electrode must first be removed.Pool pH meter in use.The electrode can be cleaned quickly and thoroughly. After cleaning the electrode with a pH-neutral liquid, the pool pH meter is immediately ready for use. The pool pH meter can be activated quickly and easily at the push of a button. Now the electrode can be immersed in the pool water. Within a few seconds, the display of the pool pH meter shows the measurement results clearly legible. The practical data hold function of the pool pH meter enables the measured values ​​to be saved. To freeze the measured value, a single push of the “Hold” button is sufficient. The manufacturer recommends cleaning the electrode of the pool pH meter with a pH-neutral liquid after each measurement. Alternative electrodes can also be connected to the pool pH meter using the BNC connector. Thanks to the ease of use, the pH meter can be easily adjusted to another electrode.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.pce-instruments.com\/english\/g\/custom\/product-pictures\/pool-ph-meter-pce-ph-16-application.jpg\" alt=\"Pool pH meter in use.\"\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eIn order to ensure long-term precise measurement results, the pool pH meter should be adjusted or calibrated at regular intervals. The pool pH meter can be adjusted manually at any time without great effort. It is sufficient to immerse the measuring electrode of the pool pH meter in a pH 7 solution. When the value has stabilized, the correct measured value can be set using the calibration screw on the top of the display using the screwdriver supplied. The user can check the result himself using other calibration solutions (e.g. pH 4 and pH 10).\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003eApplications pool pH meter\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003eThe pool pH meter is the ideal measuring instrument for every swimming pool owner who values ​​optimal water quality. The pool pH meter for monitoring swimming pool water.Unstable pH levels can unbalance pool water, cause skin and eye irritation, damage fittings and affect the way pool chemicals work. The pool pH meter from PCE Instruments combines ease of use and reliability with a compact design. The battery-operated pool pH meter is small, handy and robust and therefore ideally suited for mobile use. Thanks to its properties and easy handling, the pool pH meter is also suitable for inexperienced users. The pool pH meter guarantees maximum reliability and precise measurement results. \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.pce-instruments.com\/english\/g\/custom\/product-pictures\/pool-ph-meter-pce-ph-16-swimming-pool.jpg\" alt=\"The pool pH meter for monitoring swimming pool water.\"\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003eEquipment\u003c\/strong\u003e\u003c\/div\u003e\nSince pH electrodes can drift over time, measurement errors may occur. To ensure high measurement accuracy, the pool pH meter should be recalibrated regularly with the calibration solution available from PCE Instruments (pH 4.01 and pH 7.01). In addition to the pH meter, PCE Instruments offers the CAL-PCE-PH ISO calibration certificate for pH meters. Calibration certificates are issued specifically for customers; the annual recalibration can also be carried out at PCE Instruments. The measurement accuracy of the pH tester can be verified and documented with the calibration certificate. For optimal cleaning of the pool pH meter, the cleaning solution pepsin \/ hydrochloric acid PCE-GCS-500 (500ml) is also available from PCE Instruments. The electrode should be cleaned regularly with the cleaning solution, ideally after each use, in order to permanently avoid contamination and the measurement inaccuracies caused by it. \u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003ePortable turbidity meter according to ISO 7027 (with two automatically switching measuring ranges from 0 ... 50 NTU and 50 ... 1000 NTU)\u003c\/strong\u003e\u003c\/div\u003e\nThe PCE-TUM 20 turbidity meter is a handy meter with a large display that meets all the requirements for on-site turbidity measurement. The measuring range from 0… 1000 NTU is divided into two automatically changing ranges to increase the accuracy. The PCE-TUM 20 turbidity meter is very easy to use with the clearly laid out keyboard. An LED is used as the light source, which works with a wavelength of 830 nm in the infrared range of light and is therefore invisible to the human eye.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eSince the measurement is carried out in the non-visible area, any coloring of the sample plays only a very minor role in the measurement. By arranging the photodiodes at 180 ° and 90 ° angles, the transmitted light measurement is used for the high measuring range and the scattered light measurement is used for the low range. With the calibration standards of 0 NTU and 100 NTU included in the scope of delivery, you can calibrate and readjust the turbidity meter PCE-TUM 20 at any time. The PCE-TUM 20 turbidity meter meets all the standards required by EN 27027 \/ ISO 7027. \u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003eConductivity meter Tester for EC and TDS (sum of dissolved salts or solids)\u003c\/strong\u003e\u003c\/div\u003e\nThe conductivity tester PCE-CM 41 offers the possibility to measure the conductivity value, the sum of all dissolved solids or salts (TDS \/ Total Dissolved Solids) and the temperature. This conductivity tester can be easily carried in your pocket. The waterproof housing optimally protects the tester's electronics (also against dust). The EC u. TDS conductivity measurement is of course automatically temperature compensated. The field of application of the conductivity tester is wide-spread across all industries, fish farming, horticulture and many other areas.\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cstrong\u003ePCE-PH 16\u003c\/strong\u003e\u003cbr\u003e- Small and handy measuring device\u003cbr\u003e- Ideally suited for mobile use\u003cbr\u003e- Exchangeable electrode through BNC connection\u003cbr\u003e- 3 x 1.5V (LR44 AG-13 battery)\u003cbr\u003e- Accuracy of ± 0.1 pH\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003ePCE-TUM 20\u003c\/strong\u003e\u003cbr\u003e- Large LCD display 41 mm x 34 mm\u003cbr\u003e- Real time clock\u003cbr\u003e- High precision\u003cbr\u003e- ISO 7027 compliant\u003cbr\u003e- Infrared - turbidity measurement method\u003cbr\u003e- Scattered and transmitted light measurement\u003cbr\u003e- Data hold\u003cbr\u003e- Max and Min memory\u003cbr\u003e- 0 NTU and 100 NTU calibration\u003cbr\u003e- Compact, impact-resistant housing\u003cbr\u003e- Automatic shutdown (after 5 min)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003ePCE-CM 41\u003c\/strong\u003e\u003cbr\u003e- Two areas for high accuracy\u003cbr\u003e- Measures conductivity \/ TDS value and temperature (3 devices in one housing)\u003cbr\u003e- TDS factor can be selected\u003cbr\u003e- Automatic calibration: saves time and provides high accuracy\u003cbr\u003e- Automatic switch-off: saves batteries\u003cbr\u003e- Temperature display in °C \/ °F\u003cbr\u003e- Waterproof (IP 67)\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable cellspacing=\"0\" border=\"0\" bgcolor=\"#FFFFFF\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e\u003cspan\u003ePCE-PH 16\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eMeasuring range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0.00 ... 14.00 pH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eMeasurement accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± 0.1 pH (at 20°C \/ 68°F), ± 0.2 pH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0.01 pH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eAdjustment\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eManual one-point adjustment\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003ePower supply   \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e3 x 1.5V (LR44 AG-13 battery)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eWorking environment\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cspan\u003e0 ... 50°C \/ 32 ... 122\u003c\/span\u003e°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e175 x 51 x 25 mm \/ 6.9 x 2 x 1 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eApprox. 57 g \/ \u0026lt; 1 lb\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e\u003cspan\u003ePCE-TUM 20\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eMeasuring range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0.00 to 50.0 NTU and 50 to 1000 NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0.01 and 1 NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± 5% of meas. Measuring range or ± 0.5 NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eLight source\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eLED, infrared at 850 nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eLifespan\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eAlmost unlimited\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eLight detector\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003ePhotodiode\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eMeasurement time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e\u0026lt; 10 sec.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eBattery\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e6 x 1.5V AAA batteries\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eEnvironmental conditions      \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eMax. 50°C \/ 122°F, max. 85% RH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eDimensions (HxWxD)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e155 x 76 x 62 mm \/ 6.1 x 2.8 x 2.4 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e320 g \/ \u0026lt; 1 lb\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e\u003cspan\u003ePCE-CM 41\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eConductivity measuring range EC         \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0 ... 2000 µS \/ cm, 0 ... 20 mS \/ cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eResolution conductivity EC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e1 µS \/ cm, 0.01 mS \/ cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eAccuracy conductivity EC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± 1% of the measuring range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eMeasuring range for salinity TDS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0 ... 2000 mg \/ l (ppm), 20000 mg \/ l (ppm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eResolution salinity TDS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e1 ppm (\u0026lt; 1320 ppm), 10 ppm (\u0026gt; 1320 ppm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eAccuracy salinity TDS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± 3% of the measuring range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eMeasuring range temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cspan\u003e0 ... 60°C \/ 32 ... 140\u003c\/span\u003e°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eResolution temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cspan\u003e0.1°C \/ 0.18\u003c\/span\u003e°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eAccuracy temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cspan\u003e± 0.8°C \/ 1.5\u003c\/span\u003e°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eTDS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e1 ppm (\u0026lt; 1320 ppm) 10 ppm (\u0026gt; 1320 ppm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eCalibration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e1413 µS \/ cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eSurroundings\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0 ... 60°C \/ 32 ... 140°F, \u0026lt; 80% rh\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003ePower supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e4 x 1.5V batteries type AAA (incl.)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eDimension\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e186 x 40 mm \/ 7.3 x 1.6 in (HxW)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e130 g \/ \u0026lt; 1 lb\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x PCE-PH 16-TUM 20-CM ​​41-KIT\u003cbr\u003e1 x PCE-TUM 20 turbidity meter\u003cbr\u003e1 x PCE-CM 41 conductivity meter\u003cbr\u003e1 x Screwdriver\u003cbr\u003e1 x Calibration standard 0 NTU\u003cbr\u003e1 x Calibration standard 100 NTU\u003cbr\u003e2 x Measuring cuvettes\u003cbr\u003e1 x Cleaning solution\u003cbr\u003e1 x Cleaning cloth\u003cbr\u003e3 x 1.5V LR44 AG-13 batteries\u003cbr\u003e6 x 1.5V AAA batteries\u003cbr\u003e4 x 1.5V AAA batteries\u003cbr\u003e1 x Carrying case\u003cbr\u003e1 x Operating instructions\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003eCapacitive measuring principle for electrical resistance\u003c\/li\u003e\n\u003cli\u003eAlarm function when exceeding preset thresholds\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003eSpecifications\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring Range:\u003c\/strong\u003e 0 ... 200\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 0.1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePenetration Depth:\u003c\/strong\u003e 50 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 4 x 1.5V AAA batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDelivery Scope:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x PCE-PMI 4 Wall Moisture Meter\u003c\/li\u003e\n\u003cli\u003e4 x 1.5V AAA Batteries\u003c\/li\u003e\n\u003cli\u003e1 x User Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":48427052466405,"sku":"PCE-PH 16-TUM 20-CM 41-KIT","price":1700.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-salt-water-swimming-pool-ph-meter-kit-pce-ph-16-tum-20-cm-41-kit-5945993_1498274.webp?v=1788142786"},{"product_id":"thermo-hygrometer-pce-320","title":"Thermo-Hygrometer PCE-320","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDescription\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003eHygrometer \u003c\/span\u003e\u003cstrong\u003ePCE-320\u003cbr\u003eHumidity \/ Temperature \/ Dew point \/ Wet bulb globe temperature \/ Surface temperature\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003eWith the hygrometer it is possible to measure climate conditions such as temperature and relative humidity, as well as determining surface temperature of objects simultaneously by using the included external temperature sensor or using an infrared measurement. The hygrometer offers features such as average value, maximum, minimum, and hold functions. The hygrometer provides additional information relating to dew point temperature and the global humidity temperature. Measurement values can be directly seen on the device's LCD display, and maximum and minimum values can be registered or transferred to a PC or portable computer for further analysis.\u003c\/p\u003e\n\u003cp align=\"justify\"\u003eThe hygrometer helps prevent damage to products, such as allowing for the elimination of fungus in food when being stored and during transportation. The hygrometer is also very useful in the construction industry, industrial sector, or in product development. Customers frequently complain about not having a tool available that can measure ambient conditions and surface temperature of a wall both inside and outside. The device can be sent away to be calibrated by an accredited DIN ISO laboratory. We offer the possibility of ISO calibration from factory (when the device is ordered or as an annual recalibration).\u003c\/p\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHighlights\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Backlit LCD\u003cbr\u003e- Measures ambient humidity and temperature using an internal sensor\u003cbr\u003e- Measures surface temperature using an optional external sensor\u003cbr\u003e- Infrared measurement of a material temperature\u003cbr\u003e- Display shows temperature and humidity simultaneously\u003cbr\u003e- Determines dew point and global humidity temperature\u003cbr\u003e- Average value, Maximum, Minimum and Hold functions\u003cbr\u003e- Auto shut-off to protect battery life\u003cbr\u003e- Software for data transmission included\u003cbr\u003e- Optional ISO calibration certificate available\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSpecification\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable cellpadding=\"1\" cellspacing=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e\u003cstrong\u003eInternal probe\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eTemperature\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e-20º... 60°C \/ -4 ... 140°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eRelative humidity\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e10 ... 90% H.r.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eTemperature of global\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e-21.6 ... 60°C \/ -6.8 ... 140°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eHumidity\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e-68 ... 60°C \/ -90.4 ... 140°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eDew point temperature\u003c\/td\u003e\n\u003ctd align=\"center\"\u003edepending on the sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e\u003cstrong\u003eExternal\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eTemperature\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e-50 ... 500°C \/ -58 ... 932°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e\u003cstrong\u003eInfrared\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eTemperature resolution\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0.1°C \/ 0.18°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eRelative humidity resolution\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e\u003cstrong\u003eAccuracy (Internal)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eTemperature\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e± 1.0°C \/ 1.8°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eRelative humidity\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e± 3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eWet bulb temperature\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e± 1.0°C \/ 1.8°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eDew point temperature\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e± 1.0°C \/ 1.8°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e\u003cstrong\u003eAccuracy (External)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eTemperature\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e± 1% ± 1.0° C \/ 1.8°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e\u003cstrong\u003eInfrared\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003e-50 ... -20ºC \/ -58 ... -4ºF\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e± 5.0°C \/ 9°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003e-20 ... 500ºC \/ -4 ... 932ºF\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e± 2.0°C \/ 33.6°F  o ± 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eResponse time\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u0026lt; 4 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eHumidity sensor type\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eResistance sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eSoftware\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eFrom Windows 98\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eMemory\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eMaximum and minimum value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eExternal temperature sensor\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e1 m \/ (3.3 ft) long hot wire sensor and many other available to order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eDisplay\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eMultiple LCD for diplaying a variety of different readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003ePower\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e9V battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eOperating conditions\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e-20 ... 60°C \/ -4 ... 140°F\u003cbr\u003e0 ... 90% H.r.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eDimensions\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e257 x 76 x 53 mm \/ 10.1 x 2.9 x 2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"justify\"\u003eWeight\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e355 g \/ \u0026lt; 1 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDelivery Scope\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cp align=\"justify\"\u003e1 x Hygrometer PCE-320\u003cbr\u003e1 x External temperature sensor\u003cbr\u003e1 x Software and data cable\u003cbr\u003e1 x 9V battery\u003cbr\u003e1 x User's manual\u003c\/p\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-files\"\u003e\n\u003ch1 class=\"headline\"\u003eDownloads\u003c\/h1\u003e\n\u003cdiv class=\"pkdownloads\"\u003e\n\u003cdiv\u003e\n\u003ca class=\"\" href=\"https:\/\/www.pce-instruments.com\/english\/api\/getartfile?_fnr=1372556\u0026amp;_dsp=inline\" target=\"_blank\"\u003e\u003cbr\u003e\u003cspan class=\"mimetitle mimetitlet_custom_manual mimetitlel_EN\"\u003eManual\u003c\/span\u003e\u003c\/a\u003e\u003ca class=\"\" href=\"https:\/\/www.pce-instruments.com\/english\/api\/getartfile?_fnr=1374348\u0026amp;_dsp=inline\" target=\"_blank\"\u003e\u003cbr\u003e\u003cspan class=\"mimetitle mimetitlet_custom_datasheet mimetitlel_EN\"\u003eDatasheet\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"PCE","offers":[{"title":"Excluding ISO Calibration","offer_id":48427052826853,"sku":"PCE-320","price":1090.0,"currency_code":"NZD","in_stock":true},{"title":"Including ISO Calibration","offer_id":48427052859621,"sku":"PCE-320-ICA","price":1620.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-thermo-hygrometer-pce-320-ica-incl.-iso-calibration-certificate-6046934_2271467.webp?v=1788142784"},{"product_id":"belt-tension-meter-pce-btm-2000a","title":"Digital Belt Tension Meter PCE-BTM 2000A","description":"\u003cp\u003eThe \u003cstrong\u003ePCE-BTM 2000A Belt Tension Meter\u003c\/strong\u003e is a precision tool designed for measuring the tension of belts in drive systems. This meter helps ensure optimal belt tension, improving the performance and lifespan of belts in various industrial applications.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAccurate measurement of belt tension\u003c\/li\u003e\n  \u003cli\u003eIdeal for industrial applications\u003c\/li\u003e\n  \u003cli\u003eLightweight and portable design\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch6\u003eSpecifications\u003c\/h6\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMeasuring Range:\u003c\/strong\u003e Variable depending on belt size\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Rechargeable battery\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery Scope:\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x PCE-BTM 2000A Belt Tension Meter\u003c\/li\u003e\n  \u003cli\u003e1 x Carrying Case\u003c\/li\u003e\n  \u003cli\u003e1 x User Manual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding ISO Calibration","offer_id":48427053088997,"sku":"PCE-BTM 2000A","price":1740.0,"currency_code":"NZD","in_stock":true},{"title":"Including ISO Calibration","offer_id":48427053121765,"sku":"PCE-BTM 2000A-ICA","price":2060.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-belt-tension-meter-pce-btm-2000a-5991930_2773795.webp?v=1788142782"},{"product_id":"closing-force-measuring-device-original-bia-cl-1-for-bus-and-train-doors","title":"Bus \u0026 Train Door Force Tester BIA CL.1","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eClosing force measurement system for bus and train doors and sliding steps\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eClosing force measuring device \/ safety through closing force measurement\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv align=\"justify\"\u003eThe original BIA class 1 closing force measuring device is an electronic closing force measuring device for rail vehicle and bus doors. The elaborate design combines precision with practical robustness and ensures accurate measured values even after years of use in harsh environments.\u003cbr\u003e\u003cbr\u003eFor cyclic measurements on vehicles with multiple doors, a quick and easy implementation is of great importance. For this purpose, software was developed that drastically reduces the measurement process and the effort required for documentation. With just a few operating steps, the measurements for a complete vehicle can be taken over, printed out in tabular form and saved in a database.\u003cbr\u003e\u003cbr\u003eWe provide suitable interfaces (e.g. Microsoft® DLL or National Instruments® LabVIEW) for integration into an automated test procedure.\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Applicable standards –\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEN 14752:2005, VDV 111, 2001\/85\/EG\u003c\/strong\u003e\u003cbr\u003e- Precise measurements\u003cbr\u003e- Robust design\u003cbr\u003e- Easy to use\u003cbr\u003e- Operation with a single button or remotely via Microsoft® DLL interface or National\u003cbr\u003e    Instruments® LabView library\u003cbr\u003e- Complete scope of delivery - including high-quality transport case and software\u003cbr\u003e- Professional, comprehensive PC software – PinchPilot\u003cbr\u003e- Comprehensive user support – calibration service, standard change service\u003cbr\u003e- Support for the management of large fleets\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eOriginal BIA Class 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e25 ... 310 N\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e+\/– 3 N or 3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStiffness\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e10 N\/mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eGap width\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e115 mm \/ 4.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDiameter\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e100 mm \/ 3.9\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring principle\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eDMS transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAcquisition frequency \/ rate\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e250 Hz \/ 4 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePower supply\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003ebattery 9 V block, e.g. 6LR61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eBattery voltage monitoring\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating temperature range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-10 to +40 °C \/ 14 to 104 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage temperature range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-40 to +50 °C \/ -40 to 122 °F\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eHumidity\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003emax. 90% rel. h, non-condensing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e260 x 130 x 115 mm \/ 10.2 x 5.1 x 4.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e2.1 kg \/ 4.6 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eDisplay device SEB2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Data logger unit with LCD display and LED status indicators, control button, serial\u003cbr\u003e  interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Optional PC-controlled measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- 9 V battery supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Real time clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Memory for 100 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Sensor and PC interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Peak value display and effective power display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Rating display i. O.\/n. i. O.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e\u003cstrong\u003ePC evaluation software PinchPilot \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Multilingual (DE, EN, IT, FR, ES)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Graphic representation of the force curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Calculation of the standard-relevant characteristic values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Evaluation according to different guidelines possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Custom policy adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Log printout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Data export (Excel, CSV, PDF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Optional measuring point identification\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e- System requirements software PinchPilot (see tab Software\/App)\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Closing force measuring device BIA class 1 with 2.5 m connection cable\u003cbr\u003e1 x Display device SEB2 separate measured value acquisition module\u003cbr\u003e    with LCD and LED display membrane key and serial interface\u003cbr\u003e1 x 9V block battery\u003cbr\u003e1 x Transport case with foam insert for the complete scope of delivery\u003cbr\u003e1 x PC connection cable (USB)\u003cbr\u003e1 x USB data stick with PC evaluation software PinchPilot and documentation\u003cbr\u003e1 x Manual\u003cbr\u003e1 x ISO calibration certificate\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata5\"\u003e\n\u003ch1 class=\"headline\"\u003eSOFTWARE \/ APP\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eDescription of software \/ technical requirements\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv align=\"justify\"\u003eFor our measuring devices you need one of our software tools. Our software is used to evaluate the data obtained during closing force measurements. Depending on which measuring device or which evaluation device you have, you can download different software.\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e- PC\/Laptop Windows 7 or higher\u003cbr\u003e- USB serial port or Bluetooth interface\u003cbr\u003e- Measuring device\u003cbr\u003e- for the following measuring devices:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOriginal BIA Class 1, BIA 600, FM 100, FM 200, FM 202,\u003cbr\u003e    FM 205, FM 206, FM 207, FM 208, FM 300\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003ePC software PinchPilot\u003c\/strong\u003e\u003cbr\u003eOur \"PinchPilot\" software is used to evaluate the data obtained during closing force measurements. No additional software is required for daily work.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eData export\u003c\/strong\u003e\u003cbr\u003ePinchPilot provides all the functions required for routine measurements. Should the data nevertheless be processed further in another room, there are various types of export to choose from:\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eText export:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emeasured values as a series of numbers; can be imported e.g. into Microsoft Excel\u003cbr\u003e\u003cstrong\u003eImage export:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elog or single diagram in EMF format; can be imported, e.g. into Microsoft Word Measurement data can be exported as ppdx (XML format) and imported with our other software tools for further processing\u003cbr\u003e\u003cstrong\u003eSQL database:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA customer-specific SQL interface can be implemented on request\u003cbr\u003eNational Instruments DataPlugin (for import into Diadem or LabView)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eEvaluation according to PinchPilot guidelines\u003c\/strong\u003e\u003cbr\u003e\n\u003cdiv align=\"justify\"\u003eThe software evaluates the measurement results according to PinchPilot guidelines. These are created on the basis of applicable regulations (laws, standards, guidelines). They consist of a set of parameters that contain the permissible limit values. The measurement results obtained are evaluated accordingly. The permissible range is highlighted in color in the measurement diagram and allows a quick assessment of the measurement. We keep the PinchPilot guidelines up to date. Calibrations by us include an update of the software and thus also of the PinchPilot guidelines. With regular calibration, the user has the security of always checking according to the latest status. In addition to the assessment according to PinchPilot guidelines, the user has the option of creating their own guidelines.\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\u003cstrong\u003eResult documentation\u003c\/strong\u003e\u003cbr\u003e\n\u003cdiv align=\"justify\"\u003eThere are two options for documenting measurements in paper form: The measurement log is detailed graphic documentation for a measurement point. While the measurement report is documentation for several measurement points in tabular form. This allows all measurements on an object (door, wagon, etc.) to be documented.\u003cbr\u003eYou can set the user language yourself: German, English, French, Italian and Spanish. Software upgrade costs will apply if no license is available for the downloaded version.\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\u003cstrong\u003eThe following standards and guidelines can currently be evaluated:\u003c\/strong\u003e\u003cbr\u003eEN 81-1 2000-4-EG\u003cbr\u003eFMVSS118\u003cbr\u003eAPTA PR-M-S-18-10\u003cbr\u003eASME A17.1 2000\u003cbr\u003eEN 14752:2005\u003cbr\u003eEN 14752:2015\u003cbr\u003e2001-85-EG \/ ECE R. 107 §35 e Abs.5 StVZO\u003cbr\u003eEN14120 DIN 18650-1\u003cbr\u003eEN 12453\u003cbr\u003eEN 16005\u003cbr\u003eEN 60335-2-103\u003cbr\u003eASR A1.7\u003cbr\u003eECE R-21\u003cbr\u003eprEN 12650-1\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":48427053252837,"sku":"BIA CL. 1","price":9550.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-closing-force-measuring-device-original-bia-cl.-1-for-bus-and-train-doors-6056544_2438408.webp?v=1788142781"},{"product_id":"closing-force-measuring-device-fm208-for-sliding-roofs-automatic-windows-tailgates","title":"Sliding Roof \u0026 Tailgate Force Tester FM208","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eClosing Force Measuring Device\u003cbr\u003eClosing force measurement for sliding roofs, automatic window lifters and tailgates\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv align=\"justify\"\u003eThe closing force measuring device is an electronic measuring device for sliding roofs, automatic window lifters and tailgates in the automotive sector. Typical applications are manufacturing, development and production tests in the automotive industry. The closing force gauge with its low spring stiffness was developed to test soft elements that are clamped into a closing system. The device excels with easy handling for repetitive measurements. Its uncompromising design combines precision with practical robustness and ensures accurate readings even after years of use in harsh environments.\u003cbr\u003e\u003cbr\u003eFor measurement set-ups in testing and manufacturing, quick and easy execution is of great importance. For this purpose, software has been developed that drastically reduces the measurement procedure and the effort required for documentation. With just a few operating steps, the measurements can be transferred to a PC, evaluated, exported and documented. We provide suitable interfaces (e.g. Microsoft® DLL or National Instruments® LabVIEW) for integration into an automated test sequence.\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Support of relevant standards – 2000\/4 EG, US Standard FMVSS 118, ECE-R 21; additional measurement\u003cbr\u003e   with low spring stiffness: 2 N\/mm\u003cbr\u003e- Precise measurements - due to friction-free guidance and platform load cell\u003cbr\u003e- Robust design - durable aluminum ensures a long service life in tough use\u003cbr\u003e- Professional, extensive PC software - PinchPilot leaves nothing to be desired\u003cbr\u003e- Complete scope of supply - includes all necessary components for tailgates, windows and\u003cbr\u003e   Sunroofs packed in a high-quality transport case\u003cbr\u003e- Accessories for every application - spacers (200 mm), force introductions (clamp and platform),\u003cbr\u003e   Monopod, Bumper Support Block, Window Support Block, Sunroof Support Block,\u003cbr\u003e   sunroof spacer\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eFM208\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eApplication of force\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eon one side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e0 ... 200 N\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e+\/– 3 N (0-100 N) or +\/– 3 % (\u0026gt; 100 N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eSpring stiffness\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e2 N\/mm, +\/–(10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eGap width\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e30 mm \/ 1.1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eArea\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e20 x 20 mm \/ 0.7 x 0.7\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eForce sensor\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eDMS bridge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eca. 220 x 80 x 250 mm \/ 8.6 x 3.1 x 9.8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eca. 2.5 kg \/ 5.5 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eDisplay device SEB2.2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Display device SEB2.2 data logger unit with LCD display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e    and LED status indicators, control button, USB interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Optional PC-controlled measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Lithium polymer battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Real time clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Memory for 100 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Sensor and PC interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Peak value display and effective power display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Rating display i. O.\/n. i. O.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e\u003cstrong\u003ePC evaluation software PinchPilot\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Multilingual (DE, EN, IT, FR, ES)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Graphic representation of the force curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Calculation of the standard-relevant characteristic values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Evaluation according to different guidelines possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Custom policy adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Log printout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Data export (Excel, CSV, PDF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Optional measuring point identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e \u003cstrong\u003e- System requirements software Software PinchPilot (see tab Software\/App)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Closing force measuring device FM208\u003cbr\u003e1 x Display unit SEB2 separate with LCD display, LED status indicators, operating button and USB\u003cbr\u003e  interface\u003cbr\u003e1 x 9 V block battery\u003cbr\u003e1 x Accessory for each application: Spacer (200 mm), force inputs (clamp and platform),\u003cbr\u003e   monopod, bumper support block, window support block, sunroof support block,\u003cbr\u003e   sliding roof spacer\u003cbr\u003e1 x Transport case with foam insert for the complete scope of delivery\u003cbr\u003e1 x PC connection cable (USB)\u003cbr\u003e1 x USB stick with PC evaluation software PinchPilot\u003cbr\u003e1 x Manual\u003cbr\u003e\u003cstrong\u003e1 x ISO calibration certificate\u003c\/strong\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata5\"\u003e\n\u003ch1 class=\"headline\"\u003eSOFTWARE \/ APP\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eDescription of software \/ technical requirements\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv align=\"justify\"\u003eFor our measuring devices you need one of our software tools. Our software is used to evaluate the data obtained during closing force measurements. Depending on which measuring device or which evaluation device you have, you can download different software.\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e- PC\/Laptop Windows 7 or higher\u003cbr\u003e- USB serial port or Bluetooth interface\u003cbr\u003e- Measuring device\u003cbr\u003e- for the following measuring devices:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOriginal BIA Class 1, BIA 600, FM 100, FM 200, FM 202,\u003cbr\u003e    FM 205, FM 206, FM 207, FM 208, FM 300\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003ePC software PinchPilot\u003c\/strong\u003e\u003cbr\u003eOur \"PinchPilot\" software is used to evaluate the data obtained during closing force measurements. No additional software is required for daily work.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eData export\u003c\/strong\u003e\u003cbr\u003ePinchPilot provides all the functions required for routine measurements. Should the data nevertheless be processed further in another room, there are various types of export to choose from:\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eText export:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emeasured values as a series of numbers; can be imported e.g. into Microsoft Excel\u003cbr\u003e\u003cstrong\u003eImage export:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elog or single diagram in EMF format; can be imported, e.g. into Microsoft Word Measurement data can be exported as ppdx (XML format) and imported with our other software tools for further processing\u003cbr\u003e\u003cstrong\u003eSQL database:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA customer-specific SQL interface can be implemented on request\u003cbr\u003eNational Instruments DataPlugin (for import into Diadem or LabView)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eEvaluation according to PinchPilot guidelines\u003c\/strong\u003e\u003cbr\u003e\n\u003cdiv align=\"justify\"\u003eThe software evaluates the measurement results according to PinchPilot guidelines. These are created on the basis of applicable regulations (laws, standards, guidelines). They consist of a set of parameters that contain the permissible limit values. The measurement results obtained are evaluated accordingly. The permissible range is highlighted in color in the measurement diagram and allows a quick assessment of the measurement. We keep the PinchPilot guidelines up to date. Calibrations by us include an update of the software and thus also of the PinchPilot guidelines. With regular calibration, the user has the security of always checking according to the latest status. In addition to the assessment according to PinchPilot guidelines, the user has the option of creating their own guidelines.\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\u003cstrong\u003eResult documentation\u003c\/strong\u003e\u003cbr\u003e\n\u003cdiv align=\"justify\"\u003eThere are two options for documenting measurements in paper form: The measurement log is detailed graphic documentation for a measurement point. While the measurement report is documentation for several measurement points in tabular form. This allows all measurements on an object (door, wagon, etc.) to be documented.\u003cbr\u003eYou can set the user language yourself: German, English, French, Italian and Spanish. Software upgrade costs will apply if no license is available for the downloaded version.\u003cbr\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eThe following standards and guidelines can currently be evaluated:\u003c\/strong\u003e\u003cbr\u003eEN 81-1 2000-4-EG\u003cbr\u003eFMVSS118\u003cbr\u003eAPTA PR-M-S-18-10\u003cbr\u003eASME A17.1 2000\u003cbr\u003eEN 14752:2005\u003cbr\u003eEN 14752:2015\u003cbr\u003e2001-85-EG \/ ECE R. 107 §35 e Abs.5 StVZO\u003cbr\u003eEN14120 DIN 18650-1\u003cbr\u003eEN 12453\u003cbr\u003eEN 16005\u003cbr\u003eEN 60335-2-103\u003cbr\u003eASR A1.7\u003cbr\u003eECE R-21\u003cbr\u003eprEN 12650-1\u003c\/p\u003e\n\u003cp\u003e \u003cbr\u003eFor our measuring devices you need one of our software tools. Our software is used to evaluate the data obtained during clamping force measurements. Depending on which measuring device or which evaluation device you have, you can download different software.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":48427053678821,"sku":"FM208","price":11200.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-closing-force-measuring-device-fm208-sliding-roofs-automatic-windows-tailgates-6105.webp?v=1788142779"},{"product_id":"closing-force-measuring-device-bia-600-bt-for-rail-vehicle-doors-sliding-steps","title":"Rail Vehicle Door Force Tester BIA 600 BT","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eClosing force measuring device - Bluetooth\u003cbr\u003eWireless closing force measuring system for rail vehicle doors and sliding steps\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv align=\"justify\"\u003eThe closing force measuring device is a wireless, electronic measuring device for rail vehicle doors and sliding steps. The closing force measuring device is a further development of the well-established BIA600 closing force measuring device. It combines the well-known robust construction for years of use in harsh environments and lasting precision with the flexibility of a wireless application and a user-friendly app.\u003cbr\u003e\u003cbr\u003eThis results in many advantages for you in daily use, such as automatic measuring point identification via QR and barcodes, the immediate availability of the measured values and the direct creation of a PDF report.\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Support of relevant standards - user guidance and evaluation according to EN 14752:2015,\u003cbr\u003e   EN14752:2005 (optional)\u003cbr\u003e- Precise measurements - granted by friction-free guidance and platform load cell\u003cbr\u003e- Robust design - housing made of high-strength material for a long service life in tough applications\u003cbr\u003e   Wireless - no more annoying cables\u003cbr\u003e- Measuring point identification - via QR and barcodes (integrated solution)\u003cbr\u003e- Easy to use – implements experience from years of use\u003cbr\u003e- Extensive customer service - in-house calibration service and software updates ensure the\u003cbr\u003e   Use of current guidelines\u003cbr\u003e- Immediate evaluation - according to selected guidelines and standards\u003cbr\u003e- Process reliability - integrated test instructions ensure that the measurement is in line with the guidelines\u003cbr\u003e- Large temperature working range\u003cbr\u003e- Language selection - Available in DE\/ EN\/ ES\/ FR\/IT\/ CN\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eBIA600 BT\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eApplication of force\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eon both sides\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e0 ... 700 N\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e+\/– 3 N (0–100 N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e+\/– 3 % (\u0026gt;100 N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eSpring rate\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e10 N\/mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOpening width\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e90 mm \/ 3.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eArea\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e100 x 100 mm \/ 3.9 x 3.9\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eForce sensor\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eDMS bridge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e320 x 250 x 110 mm \/ 12.5 x 9.8 x 4.3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e3.0kg \/ 6.6 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eSpacers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Complete set for all opening widths according to EN 14752:2015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Automatic detection of the spacers used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Automatic limit value adjustment according to opening width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Easy to use, quick assembly without tools\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Robust design, low weight, POM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Together with BIA 600 sensor, SEB2 in a carrying case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e\u003cstrong\u003ePC evaluation software PinchPilot\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Multilingual (DE, EN, IT, FR, ES)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Graphic representation of the force curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Calculation of the standard-relevant characteristic values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Evaluation according to different guidelines possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Custom policy adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Log printout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Data export (Excel, CSV, PDF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Optional measuring point identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" valign=\"top\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e\u003cstrong\u003eForce Meter App downloadable from Google Play Store\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Force Meter – easy-to-use app with automatic guidelines and standards\u003cbr\u003e   updates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Time saving - immediate feedback on the measurement result including simpler\u003cbr\u003e   report generation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Paperless office - reduces paper and the associated costs and protects the\u003cbr\u003e   environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Can be used individually - integration of the customer's signature possible\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e- System requirements software PinchPilot and App (see tab Software\/App)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Closing force measuring device BIA-600 BT\u003cbr\u003e1 x Spacer (4 pieces) according to EN 14752:2015\u003cbr\u003e1 x App Force Meter available for download in the Google Play Store\u003cbr\u003e1 x Software PinchPilot (USB stick)\u003cbr\u003e1 x USB Cable\u003cbr\u003e1 x Manual\u003cbr\u003e1 x Transport case with foam insert\u003cbr\u003e1 x\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eISO calibration certificate\u003c\/strong\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata5\"\u003e\n\u003ch1 class=\"headline\"\u003eSOFTWARE \/ APP\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eDescription of software \/ technical requirements\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv align=\"justify\"\u003eFor our measuring devices you need one of our software tools. Our software is used to evaluate the data obtained during closing force measurements. Depending on which measuring device or which evaluation device you have, you can download different software.\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e- PC\/Laptop Windows 7 or higher\u003cbr\u003e- USB serial port or Bluetooth interface\u003cbr\u003e- Measuring device\u003cbr\u003e- for the following measuring devices:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOriginal BIA Class 1, BIA 600, FM 100, FM 200, FM 202,\u003cbr\u003e    FM 205, FM 206, FM 207, FM 208, FM 300\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003ePC software PinchPilot\u003c\/strong\u003e\u003cbr\u003eOur \"PinchPilot\" software is used to evaluate the data obtained during closing force measurements. No additional software is required for daily work.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eData export\u003c\/strong\u003e\u003cbr\u003ePinchPilot provides all the functions required for routine measurements. Should the data nevertheless be processed further in another room, there are various types of export to choose from:\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eText export:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emeasured values as a series of numbers; can be imported e.g. into Microsoft Excel\u003cbr\u003e\u003cstrong\u003eImage export:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elog or single diagram in EMF format; can be imported, e.g. into Microsoft Word Measurement data can be exported as ppdx (XML format) and imported with our other software tools for further processing\u003cbr\u003e\u003cstrong\u003eSQL database:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA customer-specific SQL interface can be implemented on request\u003cbr\u003eNational Instruments DataPlugin (for import into Diadem or LabView)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eEvaluation according to PinchPilot guidelines\u003c\/strong\u003e\u003cbr\u003e\n\u003cdiv align=\"justify\"\u003eThe software evaluates the measurement results according to PinchPilot guidelines. These are created on the basis of applicable regulations (laws, standards, guidelines). They consist of a set of parameters that contain the permissible limit values. The measurement results obtained are evaluated accordingly. The permissible range is highlighted in color in the measurement diagram and allows a quick assessment of the measurement. We keep the PinchPilot guidelines up to date. Calibrations by us include an update of the software and thus also of the PinchPilot guidelines. With regular calibration, the user has the security of always checking according to the latest status. In addition to the assessment according to PinchPilot guidelines, the user has the option of creating their own guidelines.\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\u003cstrong\u003eResult documentation\u003c\/strong\u003e\u003cbr\u003e\n\u003cdiv align=\"justify\"\u003eThere are two options for documenting measurements in paper form: The measurement log is detailed graphic documentation for a measurement point. While the measurement report is documentation for several measurement points in tabular form. This allows all measurements on an object (door, wagon, etc.) to be documented.\u003cbr\u003eYou can set the user language yourself: German, English, French, Italian and Spanish. Software upgrade costs will apply if no license is available for the downloaded version.\u003cbr\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eThe following standards and guidelines can currently be evaluated:\u003c\/strong\u003e\u003cbr\u003eEN 81-1 2000-4-EG\u003cbr\u003eFMVSS118\u003cbr\u003eAPTA PR-M-S-18-10\u003cbr\u003eASME A17.1 2000\u003cbr\u003eEN 14752:2005\u003cbr\u003eEN 14752:2015\u003cbr\u003e2001-85-EG \/ ECE R. 107 §35 e Abs.5 StVZO\u003cbr\u003eEN14120 DIN 18650-1\u003cbr\u003eEN 12453\u003cbr\u003eEN 16005\u003cbr\u003eEN 60335-2-103\u003cbr\u003eASR A1.7\u003cbr\u003eECE R-21\u003cbr\u003eprEN 12650-1\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003eForce Meter App \/ Description\u003c\/span\u003e\u003cbr\u003eFor our measuring devices you need one of our software tools. Our software is used to evaluate the data obtained during clamping force measurements. Depending on which measuring device or which evaluation device you have, you can download different software.\u003cbr\u003e   \u003cbr\u003e- Download App in Google Play Store\u003cbr\u003e- Android device\u003cbr\u003e- for the following measuring devices: BIA-1 BT, BIA-600 BT, FM-100 BT, FM-300 BT\u003cbr\u003e   \u003cbr\u003e\u003cstrong\u003eTechnical requirements\u003c\/strong\u003e\u003cbr\u003e- Mobile Android device (tablet\/ smartphone)\u003cbr\u003e- Android 5.0 or higher\u003cbr\u003e- Bluetooth interface\u003cbr\u003e- Bluetooth measuring device (wireless\/ wireless)\u003cbr\u003e   \u003cbr\u003e\u003cspan style=\"font-size: large;\"\u003eFeatures of the Force Meter App for Android\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAcquisition and visualization of measurement data\u003c\/strong\u003e\u003cbr\u003eThe app displays the data after the measurement in a graph. In addition, other parameters for the measurement are calculated and presented in tabular form. All data is stored in a local database on the device and can therefore be easily found again later.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eEvaluation according to the standard\u003c\/strong\u003e\u003cbr\u003eThe app evaluates measurements according to predefined evaluation criteria. These are created on the basis of applicable regulations (laws, directives, norms, standards). The permissible values are shown in the measurement diagram or in tabular form and thus allow a quick assessment of the measurement. We keep the evaluation criteria up to date and users can easily get updates from the Google Play Store.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eUser guidance through measurement process\u003c\/strong\u003e\u003cbr\u003eThe user is guided intuitively through the measurement process if a corresponding standard or guideline has been selected before the measurement. Depending on the point to be measured, the app provides information on how to carry out the measurement.\u003cbr\u003eAll measuring points are displayed in a list and are marked as completed after the measurement. In this way, the user always has an overview of the measurement to be carried out.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOwn measuring objects and measuring point identification\u003c\/strong\u003e\u003cbr\u003eThe user has the option of creating a measurement object and saving all relevant data such as designation, serial number, type or owner. In addition, a bar or QR code can be stored on the measurement object. Thanks to the device's integrated camera, measurement objects can be easily selected at a later point in time in order to carry out a new measurement. In the results window, these characteristic data can be filtered in order to obtain all measurements for a measurement object.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eReport creation and data export\u003c\/strong\u003e\u003cbr\u003eImmediately after the measurement, a PDF report is created for the measurement. The user has the option of forwarding this PDF directly via email or storing it in a storage location (device, cloud, etc.). If a printer is connected to the Android device, the report can also be printed immediately. The signature and comment functions are useful functions for creating reports for your customers. In addition, we offer a function for creating photos with the device's internal camera. These can be included in the report for documentation. In addition, there is the option of exporting the measurement data as ppdx (XML format). You can, for example, open and process these with our other software tools.\u003cbr\u003e\u003cbr\u003eYou can set the user language yourself: German, English, French, Italian and Spanish.\u003cbr\u003e   \u003cbr\u003e\u003cstrong\u003eThe following standards and guidelines can currently be evaluated:\u003c\/strong\u003e\u003cbr\u003eASR 1.7\u003cbr\u003eEN 12453:2017\u003cbr\u003eDHF-TS-011:2018\u003cbr\u003eEN 16005:2012\u003cbr\u003eEN 18650-1:2010\u003cbr\u003eEN 14752\u003cbr\u003e2000\/4 EC\u003cbr\u003eDIN EN 81-20\u003cbr\u003e \u003cbr\u003eFor our measuring devices you need one of our software tools. Our software is used to evaluate the data obtained during clamping force measurements. Depending on which measuring device or which evaluation device you have, you can download different software.\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":48427053744357,"sku":"BIA 600 BT","price":12100.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-closing-force-measuring-device-bia-600-bt-for-rail-vehicle-doors-sliding-_4.webp?v=1788142778"},{"product_id":"closing-force-measuring-device-fm205-5-for-automatic-window-regulators","title":"Automatic Window Force Gauge FM205\/5","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eClosing Force Measuring Device\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eClosing force measurement for automatic window regulators\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv align=\"justify\"\u003eThe closing force measuring device is an electronic closing force measuring device for power-operated windows in the automotive sector. Typical areas of application are testing and production in the automotive industry. For this purpose, we have developed a device that is easy to use for repetitive measurements. Due to the requirements of various common standards, we offer the device with different spring stiffnesses. It is also increasingly used by technical monitoring institutions. Its uncompromising design combines precision with practical robustness and ensures accurate measurements even after years of use in harsh environments.\u003cbr\u003e\u003cbr\u003eFor measurement set-ups in testing and production, quick and easy execution is of great importance. For this purpose, software has been developed that drastically reduces the measurement procedure and the effort required for documentation. With just a few operating steps, the measurements can be transferred to a PC, evaluated, exported and documented. We provide suitable interfaces (e.g. Microsoft® DLL or National Instruments® LabVIEW) for integration into an automated test sequence.\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Precise measurements - due to friction-free guidance and platform load cell\u003cbr\u003e- Robust design - high-strength aluminum and POM ensure a long service life in tough applications\u003cbr\u003e- Ease of use - single button operation or remote control via Microsoft® DLL -\u003cbr\u003e   Interface or National Instruments® LabVIEW library\u003cbr\u003e- Professional, extensive PC software - PinchPilot leaves nothing to be desired\u003cbr\u003e- Available in multiple spring rates - 2, 5, 10, 20, 65 N\/mm\u003cbr\u003e- Complete scope of delivery - including high-quality transport case\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eFM205\/5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eApplication of force\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eon one side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e0 ... 75 N\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e+\/– 3 N (0–100 N) or\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e+\/– 3 % (\u0026gt;100 N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eSpring stiffness\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e5 N\/mm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eGap width\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eFmax. 5 mm \/ 0.19\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eArea\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e5 x 80 mm \/ 0.19 x 3.1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eForce sensor\u003cbr\u003eCable length\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003estrain gauge bridge\u003cbr\u003e1.5 m \/ 4.9 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e175 x 75 x 57 mm \/ 6.8 x 2.9 x 2.2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eca. 400 g \/ 14 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eDisplay device SEB2.2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Display device SEB2.2 data logger unit with LCD display and LED status indicators,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e  Control button, USB interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Optional PC-controlled measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Lithium polymer battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Real time clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Memory for 100 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Sensor and PC interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Peak value display and effective power display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Rating display i. O.\/n. i. O.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eSpacers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Complete set for all opening widths according to EN 14752:2015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Automatic detection of the spacers used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Automatic limit value adjustment according to opening width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Easy to use, quick assembly without tools\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Robust design, low weight, POM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Together with BIA 600 sensor, SEB2 in a carrying case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e\u003cstrong\u003ePC evaluation software PinchPilot\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Multilingual (DE, EN, IT, FR, ES)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Graphic representation of the force curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Calculation of the standard-relevant characteristic values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Evaluation according to different guidelines possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Custom policy adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Log printout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Data export (Excel, CSV, PDF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Optional measuring point identification\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e- System requirements software PinchPilot (see tab Software\/App)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Closing force measuring device FM205\/5\u003cbr\u003e1 x Sensor 5N\/mm\u003cbr\u003e1 x SEB2.2 indicator\u003cbr\u003e1 x PinchPilot software\u003cbr\u003e\u003cstrong\u003e1 x ISO calibration certificate\u003c\/strong\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata5\"\u003e\n\u003ch1 class=\"headline\"\u003eSOFTWARE \/ APP\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eDescription of software \/ technical requirements\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv align=\"justify\"\u003eFor our measuring devices you need one of our software tools. Our software is used to evaluate the data obtained during closing force measurements. Depending on which measuring device or which evaluation device you have, you can download different software.\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e- PC\/Laptop Windows 7 or higher\u003cbr\u003e- USB serial port or Bluetooth interface\u003cbr\u003e- Measuring device\u003cbr\u003e- for the following measuring devices:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOriginal BIA Class 1, BIA 600, FM 100, FM 200, FM 202,\u003cbr\u003e    FM 205, FM 206, FM 207, FM 208, FM 300\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003ePC software PinchPilot\u003c\/strong\u003e\u003cbr\u003eOur \"PinchPilot\" software is used to evaluate the data obtained during closing force measurements. No additional software is required for daily work.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eData export\u003c\/strong\u003e\u003cbr\u003ePinchPilot provides all the functions required for routine measurements. Should the data nevertheless be processed further in another room, there are various types of export to choose from:\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eText export:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emeasured values as a series of numbers; can be imported e.g. into Microsoft Excel\u003cbr\u003e\u003cstrong\u003eImage export:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elog or single diagram in EMF format; can be imported, e.g. into Microsoft Word Measurement data can be exported as ppdx (XML format) and imported with our other software tools for further processing\u003cbr\u003e\u003cstrong\u003eSQL database:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA customer-specific SQL interface can be implemented on request\u003cbr\u003eNational Instruments DataPlugin (for import into Diadem or LabView)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eEvaluation according to PinchPilot guidelines\u003c\/strong\u003e\u003cbr\u003e\n\u003cdiv align=\"justify\"\u003eThe software evaluates the measurement results according to PinchPilot guidelines. These are created on the basis of applicable regulations (laws, standards, guidelines). They consist of a set of parameters that contain the permissible limit values. The measurement results obtained are evaluated accordingly. The permissible range is highlighted in color in the measurement diagram and allows a quick assessment of the measurement. We keep the PinchPilot guidelines up to date. Calibrations by us include an update of the software and thus also of the PinchPilot guidelines. With regular calibration, the user has the security of always checking according to the latest status. In addition to the assessment according to PinchPilot guidelines, the user has the option of creating their own guidelines.\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\u003cstrong\u003eResult documentation\u003c\/strong\u003e\u003cbr\u003e\n\u003cdiv align=\"justify\"\u003eThere are two options for documenting measurements in paper form: The measurement log is detailed graphic documentation for a measurement point. While the measurement report is documentation for several measurement points in tabular form. This allows all measurements on an object (door, wagon, etc.) to be documented.\u003cbr\u003eYou can set the user language yourself: German, English, French, Italian and Spanish. Software upgrade costs will apply if no license is available for the downloaded version.\u003cbr\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eThe following standards and guidelines can currently be evaluated:\u003c\/strong\u003e\u003cbr\u003eEN 81-1 2000-4-EG\u003cbr\u003eFMVSS118\u003cbr\u003eAPTA PR-M-S-18-10\u003cbr\u003eASME A17.1 2000\u003cbr\u003eEN 14752:2005\u003cbr\u003eEN 14752:2015\u003cbr\u003e2001-85-EG \/ ECE R. 107 §35 e Abs.5 StVZO\u003cbr\u003eEN14120 DIN 18650-1\u003cbr\u003eEN 12453\u003cbr\u003eEN 16005\u003cbr\u003eEN 60335-2-103\u003cbr\u003eASR A1.7\u003cbr\u003eECE R-21\u003cbr\u003eprEN 12650-1\u003c\/p\u003e\n\u003cp\u003e \u003cbr\u003eFor our measuring devices you need one of our software tools. Our software is used to evaluate the data obtained during clamping force measurements. Depending on which measuring device or which evaluation device you have, you can download different software.\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":48427053809893,"sku":"FM205\/5","price":9250.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-closing-force-measuring-device-fm205-5-for-automatic-window-regulators-610524.webp?v=1788142777"},{"product_id":"closing-force-measuring-device-fm205-20-for-automatic-window-regulators","title":"Automatic Window Force Gauge FM205\/20","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eClosing Force Measuring Device\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eClosing force measurement for automatic window regulators\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv align=\"justify\"\u003eThe closing force measuring device is an electronic closing force measuring device for power-operated windows in the automotive sector. Typical areas of application are testing and production in the automotive industry. For this purpose, we have developed a device that is easy to use for repetitive measurements. Due to the requirements of various common standards, we offer the device with different spring stiffnesses. It is also increasingly used by technical monitoring institutions. Its uncompromising design combines precision with practical robustness and ensures accurate measurements even after years of use in harsh environments.\u003cbr\u003e\u003cbr\u003eFor measurement set-ups in testing and production, quick and easy execution is of great importance. For this purpose, software has been developed that drastically reduces the measurement procedure and the effort required for documentation. With just a few operating steps, the measurements can be transferred to a PC, evaluated, exported and documented. We provide suitable interfaces (e.g. Microsoft® DLL or National Instruments® LabVIEW) for integration into an automated test sequence.\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Support of relevant standards – US Standard FMVSS 118\u003cbr\u003e- Precise measurements - due to friction-free guidance and platform load cell\u003cbr\u003e- Robust design - high-strength aluminum and POM ensure a long service life in tough applications\u003cbr\u003e- Ease of use - single button operation or remote control via Microsoft® DLL -\u003cbr\u003e   Interface or National Instruments® LabVIEW library\u003cbr\u003e- Professional, extensive PC software - PinchPilot leaves nothing to be desired\u003cbr\u003e- Available in multiple spring rates - 2, 5, 10, 20, 65 N\/mm\u003cbr\u003e- Complete scope of delivery - including high-quality transport case\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eFM205\/20\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eApplication of force\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eon one side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e0 ... 200 N\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e+\/– 3 N (0–100 N) or\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e+\/– 3 % (\u0026gt;100 N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eSpring stiffness\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e20 N\/mm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eGap width\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eFmax. 5 mm \/ 0.19\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eArea\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e5 x 80 mm \/ 0.19 x 3.1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eForce sensor\u003cbr\u003eCable length\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003estrain gauge bridge\u003cbr\u003e1.5 m \/ 4.9 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e175 x 75 x 57 mm \/ 6.8 x 2.9 x 2.2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eca. 400 g \/ 14 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eDisplay device SEB2.2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Display device SEB2.2 data logger unit with LCD display and LED status indicators,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e  Control button, USB interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Optional PC-controlled measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Lithium polymer battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Real time clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Memory for 100 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Sensor and PC interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Peak value display and effective power display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Rating display i. O.\/n. i. O.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eSpacers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Complete set for all opening widths according to EN 14752:2015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Automatic detection of the spacers used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Automatic limit value adjustment according to opening width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Easy to use, quick assembly without tools\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Robust design, low weight, POM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Together with BIA 600 sensor, SEB2 in a carrying case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e\u003cstrong\u003ePC evaluation software PinchPilot\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Multilingual (DE, EN, IT, FR, ES)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Graphic representation of the force curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Calculation of the standard-relevant characteristic values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Evaluation according to different guidelines possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Custom policy adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Log printout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Data export (Excel, CSV, PDF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e- Optional measuring point identification\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e- System requirements software PinchPilot (see tab Software\/App)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Closing force measuring device FM205\/20\u003cbr\u003e1 x Sensor 20N\/mm\u003cbr\u003e1 x SEB2.2 indicator\u003cbr\u003e1 x PinchPilot software\u003cbr\u003e\u003cstrong\u003e1 x ISO calibration certificate\u003c\/strong\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata5\"\u003e\n\u003ch1 class=\"headline\"\u003eSOFTWARE \/ APP\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eDescription of software \/ technical requirements\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv align=\"justify\"\u003eFor our measuring devices you need one of our software tools. Our software is used to evaluate the data obtained during closing force measurements. Depending on which measuring device or which evaluation device you have, you can download different software.\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e- PC\/Laptop Windows 7 or higher\u003cbr\u003e- USB serial port or Bluetooth interface\u003cbr\u003e- Measuring device\u003cbr\u003e- for the following measuring devices:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOriginal BIA Class 1, BIA 600, FM 100, FM 200, FM 202,\u003cbr\u003e    FM 205, FM 206, FM 207, FM 208, FM 300\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003ePC software PinchPilot\u003c\/strong\u003e\u003cbr\u003eOur \"PinchPilot\" software is used to evaluate the data obtained during closing force measurements. No additional software is required for daily work.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eData export\u003c\/strong\u003e\u003cbr\u003ePinchPilot provides all the functions required for routine measurements. Should the data nevertheless be processed further in another room, there are various types of export to choose from:\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eText export:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emeasured values as a series of numbers; can be imported e.g. into Microsoft Excel\u003cbr\u003e\u003cstrong\u003eImage export:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elog or single diagram in EMF format; can be imported, e.g. into Microsoft Word Measurement data can be exported as ppdx (XML format) and imported with our other software tools for further processing\u003cbr\u003e\u003cstrong\u003eSQL database:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA customer-specific SQL interface can be implemented on request\u003cbr\u003eNational Instruments DataPlugin (for import into Diadem or LabView)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eEvaluation according to PinchPilot guidelines\u003c\/strong\u003e\u003cbr\u003e\n\u003cdiv align=\"justify\"\u003eThe software evaluates the measurement results according to PinchPilot guidelines. These are created on the basis of applicable regulations (laws, standards, guidelines). They consist of a set of parameters that contain the permissible limit values. The measurement results obtained are evaluated accordingly. The permissible range is highlighted in color in the measurement diagram and allows a quick assessment of the measurement. We keep the PinchPilot guidelines up to date. Calibrations by us include an update of the software and thus also of the PinchPilot guidelines. With regular calibration, the user has the security of always checking according to the latest status. In addition to the assessment according to PinchPilot guidelines, the user has the option of creating their own guidelines.\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\u003cstrong\u003eResult documentation\u003c\/strong\u003e\u003cbr\u003e\n\u003cdiv align=\"justify\"\u003eThere are two options for documenting measurements in paper form: The measurement log is detailed graphic documentation for a measurement point. While the measurement report is documentation for several measurement points in tabular form. This allows all measurements on an object (door, wagon, etc.) to be documented.\u003cbr\u003eYou can set the user language yourself: German, English, French, Italian and Spanish. Software upgrade costs will apply if no license is available for the downloaded version.\u003cbr\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eThe following standards and guidelines can currently be evaluated:\u003c\/strong\u003e\u003cbr\u003eEN 81-1 2000-4-EG\u003cbr\u003eFMVSS118\u003cbr\u003eAPTA PR-M-S-18-10\u003cbr\u003eASME A17.1 2000\u003cbr\u003eEN 14752:2005\u003cbr\u003eEN 14752:2015\u003cbr\u003e2001-85-EG \/ ECE R. 107 §35 e Abs.5 StVZO\u003cbr\u003eEN14120 DIN 18650-1\u003cbr\u003eEN 12453\u003cbr\u003eEN 16005\u003cbr\u003eEN 60335-2-103\u003cbr\u003eASR A1.7\u003cbr\u003eECE R-21\u003cbr\u003eprEN 12650-1\u003c\/p\u003e\n\u003cp\u003e \u003cbr\u003eFor our measuring devices you need one of our software tools. Our software is used to evaluate the data obtained during clamping force measurements. Depending on which measuring device or which evaluation device you have, you can download different software.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":48427054366949,"sku":"FM205\/20","price":9250.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-closing-force-measuring-device-fm205-20-for-automatic-window-regulators-6105244_2_1.webp?v=1788142773"},{"product_id":"force-gauge-pce-fm-500n","title":"Digital Force Gauge PCE-FM Series","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eForce Gauge PCE-FM 50\/ 200\/ 500N\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eUSB interface and downloadable evaluation software for data transmission \/ Many measuring adapters\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eThe force gauge FM is a handheld device that measures up to 200 N. The force gauge can determine the units N, kg and lb. The scope of delivery of the PCE-FM 200 force gauge includes various adapters with different shapes. These can be screwed onto the device and thus offer the optimum solution for differently designed surfaces in the measurement of pressure and tension. In addition to the adapters, an extension rod is also supplied, which allows measurements in hard to reach places. This extension rod has a length of 65 millimeters. The scope of delivery of the PCE-FM 200 force gauge includes flat head adapter, hook adapter, ball head adapter, chisel head adapter and a notched head adapter, whereby the hook adapter is used for tensile force measurements. \u003c\/div\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eThe PCE-FM force gauge offers the option of mounting the force gauge on a test stand by means of threads on the rear of the device. Test stands are always used in a force gauge if reproducible measurement results are required during the force measurement. These test stands are ideal additions to a force gauge, because they are operated by a precise handwheel or a motor. In addition, both tensile and compressive force measurements can be performed on them. Experiments in the laboratory are thus possible with the force gauge as well as the inspection of incoming goods.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eAttention:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal load cell is maintenance-free, light and characterized by extremely long service life. For the production of this load cell only high quality materials are used, which guarantee maximum safety and longevity. The force gauge has an overload range. If you exceed this, you destroy the internal load cell. So if you select a force gauge for your application, then for safety's sake move to the next higher model at the measuring range.\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e- Differently shaped measuring adapters\u003c\/div\u003e\n\u003cdiv\u003e- Downloadable evaluation software\u003c\/div\u003e\n\u003cdiv\u003e- Device for mounting on test stands\u003c\/div\u003e\n\u003cdiv\u003e- Peak measurement\u003c\/div\u003e\n\u003cdiv\u003e- Power supply via charging adapter\u003c\/div\u003e\n\u003cdiv\u003e- Delivery includes extension rod\u003c\/div\u003e\n\u003cdiv\u003e- Evaluation via USB interface\u003c\/div\u003e\n\u003cdiv\u003e- Fast display of measured value\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"160\" valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd width=\"441\" valign=\"top\"\u003e\n\u003cp\u003e50\/ 200\/ 500N\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 N \/ 0.02 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePressure calibration\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 Mpa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eLoad cell\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIntegrated load cell with M6 connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 ... 100% of the full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasurement accuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eUnits\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003en, kg, lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDisplay\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e10 ... 30°C \/ 50 ... 86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eRelative humidity\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e15 ... 80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWorking conditions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eThe device must not be located near sources of vibration or corrosive substances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 kg \/ 2.2 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e1 x Force Gauge PCE-FM 50\/ 200\/ 500N\u003c\/div\u003e\n\u003cdiv\u003e1 x Downloadable evaluation software\u003c\/div\u003e\n\u003cdiv\u003e1 x Flathead adapter\u003c\/div\u003e\n\u003cdiv\u003e1 x Hook adapter\u003c\/div\u003e\n\u003cdiv\u003e1 x Ball head adapter\u003c\/div\u003e\n\u003cdiv\u003e1 x Chisel head adapter\u003c\/div\u003e\n\u003cdiv\u003e1 x Notch head adapter\u003c\/div\u003e\n\u003cdiv\u003e1 x Adapter for extension rod\u003c\/div\u003e\n\u003cdiv\u003e1 x Extension rod (65 mm \/ 2.55\")\u003c\/div\u003e\n\u003cdiv\u003e1 x USB cable\u003c\/div\u003e\n\u003cdiv\u003e1 x Charging adapter (240 V)\u003c\/div\u003e\n\u003cdiv\u003e1 x Equipment case\u003c\/div\u003e\n\u003cdiv\u003e1 x Operation manual\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding ISO Calibration","offer_id":48427054432485,"sku":"PCE-FM 50\/ 200\/ 500N","price":1210.0,"currency_code":"NZD","in_stock":true},{"title":"Including ISO Calibration","offer_id":48427054465253,"sku":"PCE-FM 50\/ 200\/ 500N-ICA","price":1650.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-force-gage-pce-fm-50n-ica-incl.-iso-calibration-certificate-5953284_2263531.webp?v=1788142771"},{"product_id":"force-gauge-pce-dfg-n-50k","title":"Digital Force Gauge PCE-DFG N Series","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eForce gauge PCE-DFG N 20K\/ 50K\/ 100K\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ewith external S load cell, USB interface and PC software\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003eThe force measuring device measures both tensile forces and compressive forces and this with a very high resolution. The tensile force or compressive force is often required in test laboratories, for example. The force gauge is supplied with an external measuring cell. The measuring cell is connected to the force measuring device by an approx. 6 m long sensor cable. The force measuring device or the force measuring cell has an M20 thread mount to initiate the tensile or compressive forces.\u003cbr\u003e\u003cbr\u003eThe force measuring device can work with a sampling rate of up to 1600 Hz. The scanned measured values ​​are displayed as instantaneous values ​​as well as in a graphical measurement curve directly in the force measuring device. The measurements can be stored in the internal memory or transferred as a live measurement via USB interface with the software included in the scope of delivery with a maximum of 800 Hz. The force measuring device has a graphic LCD that displays the measured values ​​numerically and graphically. Furthermore, the force measuring device is protected according to IP54 and can therefore also be used in harsh industrial environments.\u003cbr\u003e\u003cbr\u003eThe force measuring device offers the possibility of storing two limit values ​​that are continuously compared with the current value. If these limit values ​​are exceeded or not reached, a signal appears in the display of the force measuring device, as well as a reaction via external interfaces, e.g. this can be used to control a testing machine.\u003c\/p\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- USB interface\u003cbr\u003e- Graphic display\u003cbr\u003e- Fast response time\u003cbr\u003e- PC software incl.\u003cbr\u003e- Memory for 100 measurements\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e20K\/ 50K\/ 100K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.005 kN \/ 5 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±0.2% of the measuring range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasurement units\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003ekN, t, klb, MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDisplay\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e2.8\" TFT graphic display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAlarm modes\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eInside, Outside, Crack\/Overload, Shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eSampling rate\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e6 ... 1600 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMemory\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e100 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePower supply\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eNiMh battery, 6 V \/ 1600 mAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eBattery life\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eapprox. 10 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePower supply \/ charging adapter\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e12 V \/ 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOutputs\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003einterface: USB\u003cbr\u003eswitching output: 12 V \/ 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eProtection class handset\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIP 54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eProtection class load cell\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIP 67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating and storage conditions  \u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-10 ... 50 °C\u003cbr\u003e5 ... 95 % r.h. not condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions of load cell\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eL 76.2 mm \/ H 101.6 mm \/ W 27.2 mm \/ M20 x 1.5 thread \/ 2800 g\u003cbr\u003e(see technical drawing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eCable length load cell\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eca. 6 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions of handset\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e200 x 97 x 42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight of handset\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e540 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Force Gauge PCE-DFG N 20K 50K\/ 100K \u003cbr\u003e1 x Load cell (depending on model)\u003cbr\u003e1 x USB cable\u003cbr\u003e1 x Charger\u003cbr\u003e1 x PC software\u003cbr\u003e1 x User manual\u003cbr\u003e\u003cstrong\u003e(Eye bolts optional, see accessories)\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding \/ 20K","offer_id":48427054989541,"sku":"PCE-DFG N 50K","price":3380.0,"currency_code":"NZD","in_stock":true},{"title":"Excluding \/ 50K","offer_id":48427055022309,"sku":null,"price":3380.0,"currency_code":"NZD","in_stock":true},{"title":"Excluding \/ 100K","offer_id":48427055055077,"sku":null,"price":3380.0,"currency_code":"NZD","in_stock":true},{"title":"Including \/ 20K","offer_id":48427055087845,"sku":null,"price":4000.0,"currency_code":"NZD","in_stock":true},{"title":"Including \/ 50K","offer_id":48427055120613,"sku":null,"price":4000.0,"currency_code":"NZD","in_stock":true},{"title":"Including \/ 100K","offer_id":48427055153381,"sku":null,"price":4000.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-force-gage-pce-dfg-n-50k-ica-incl.-iso-calibration-certificate-5952114_1565675_ad816c2a-97d3-4a9d-9602-1e3046c2093e.webp?v=1788142767"},{"product_id":"force-gauge-pce-dfg-nf-0-5k","title":"Digital Force Gauge PCE-DFG NF Series","description":"\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eForce Gage\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003ePCE-DFG NF 0..50K\u003c\/strong\u003e\u003cspan\u003e\u003cbr\u003eW\u003c\/span\u003e\u003cstrong\u003eith external load cell, USB interface and PC software\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv\u003eThe force gage with an external load cell is designed for the measurement of compressive forces at hard-to-reach measuring points. The pressure cell is connected to the force gage by a sensor cable of approx. 3 m length and thanks to the small cell dimensions it ensures a versatile application. The force gage or the load cell has on the bottom of several threaded holes that allow a firm installation.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eThe force gage can operate at a sampling rate of up to 1600 Hz. The sampled measured values ​​are displayed as an instantaneous value, as well as in a graph trace directly in the force gage.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eThe measurements can be stored in the internal memory or transmitted via USB interface with the included software with a maximum of 800 Hz as a live measurement.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eThe PEAK Hold function allows freezing of the highest measured value in the force gage until this value is exceeded or cleared.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eThe force gage offers the option of storing two limit values, which are continuously compared with the instantaneous value. When exceeding or falling below these limits, a signal in the display of the force gage, as well as a reaction via external interfaces, which can be used for example for the control of a testing machine.\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-customdata2\" class=\"tab-pane clear fade in\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- USB interface\u003cbr\u003e- Graphic display\u003cbr\u003e- Fast response time\u003cbr\u003e- PC software\u003cbr\u003e- Memory for 100 measurements\u003cbr\u003e-\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIncl. ISO calibration certificate\u003c\/strong\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-customdata3\" class=\"tab-pane clear fade in\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e0 ... 50k\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 N \/ 0.22 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e± 0.5% of the measuring range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasurement units\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eN, kg, lb, kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDisplay\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e2.8\" TFT graphic display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAlarm Modes\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eInside, Outside, Crack, Shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eSampling rate\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e6 ... 1600 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e100 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePower supply\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eNiMH battery, 6V \/ 1600-mAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eBattery life\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eAbout 10 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePower adapter \/ charging adapter      \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e12V \/ 1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOutputs\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eInterface: USB switching output: 12V \/ 50-mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eProtection class\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIP 54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating and storage conditions   \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-10 ... 50°C \/ -14 ... 122°F\u003cbr\u003e5 ... 95% rh non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions pressure cell\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eØ 32 mm \/ H 16 mm \/ M5 thread\u003cbr\u003e(see technical drawing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eCable length pressure cell\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eAbout 3 m \/ 9.8 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e200 x 97 x 42 mm \/ 7.9 x 3.8 x 1.7 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e540 g \/ 1.2 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-customdata4\" class=\"tab-pane clear fade in\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x PCE-DFG NF Force Gage (depending on model)\u003cbr\u003e1 x Pressure cell (depending on model)\u003cbr\u003e1 x USB cable\u003cbr\u003e1 x Charger\u003cbr\u003e1 x PC software\u003cbr\u003e1 x User manual\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding \/ 0.5K","offer_id":48427055448293,"sku":"PCE-DFG NF 0.5K","price":3210.0,"currency_code":"NZD","in_stock":true},{"title":"Excluding \/ 1K","offer_id":48427055481061,"sku":null,"price":3210.0,"currency_code":"NZD","in_stock":true},{"title":"Excluding \/ 2K","offer_id":48427055513829,"sku":null,"price":3210.0,"currency_code":"NZD","in_stock":true},{"title":"Excluding \/ 5K","offer_id":48427055546597,"sku":null,"price":3210.0,"currency_code":"NZD","in_stock":true},{"title":"Excluding \/ 10K","offer_id":48427055579365,"sku":null,"price":4670.0,"currency_code":"NZD","in_stock":true},{"title":"Excluding \/ 20K","offer_id":48427055612133,"sku":null,"price":4670.0,"currency_code":"NZD","in_stock":true},{"title":"Excluding \/ 50K","offer_id":48427055644901,"sku":null,"price":4670.0,"currency_code":"NZD","in_stock":true},{"title":"Including \/ 0.5K","offer_id":48427055677669,"sku":null,"price":3760.0,"currency_code":"NZD","in_stock":true},{"title":"Including \/ 1K","offer_id":48427055710437,"sku":null,"price":3760.0,"currency_code":"NZD","in_stock":true},{"title":"Including \/ 2K","offer_id":48427055743205,"sku":null,"price":3760.0,"currency_code":"NZD","in_stock":true},{"title":"Including \/ 5K","offer_id":48427055775973,"sku":null,"price":3760.0,"currency_code":"NZD","in_stock":true},{"title":"Including \/ 10K","offer_id":48427055808741,"sku":null,"price":5200.0,"currency_code":"NZD","in_stock":true},{"title":"Including \/ 20K","offer_id":48427055841509,"sku":null,"price":5200.0,"currency_code":"NZD","in_stock":true},{"title":"Including \/ 50K","offer_id":48427055874277,"sku":null,"price":5200.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-force-gage-pce-dfg-nf-10k-ica-incl.-iso-calibration-certificate-5952148_1566532_1.webp?v=1788142765"},{"product_id":"torque-meter-pce-dfg-n-100tw","title":"Digital Torque Meter PCE-DFG","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cbr\u003e\n\u003cdiv\u003eThe torque wrench tester consists of a handheld measuring device and an external torque transducer. The torsion transducer is connected to the hand-held device via a 1.5 m \/ 4.9 ft long cable and thus enables installation in a test stand or direct assembly on a test bench.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eThe torque measuring device is delivered adjusted so that the control measurements can be started immediately. A calibration certificate is optionally available for the torque measuring device. This certificate is a target \/ actual comparison on a traceable reference standard and thus serves as proof of the measurement accuracy. The measurement uncertainty of the torque measuring device is only 0.5% of the measuring range. The torque measuring device is therefore used as a reference device for testing and adjusting static torque tools. A screw latch is essential for dynamic torques.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eThe torque transducer has a 1\/2\" square socket and can perform the torsion measurements in both directions of rotation. With a sampling rate of 1600 Hz, the torque meter reliably detects the first and the maximum torsional moment peak (PEAK). The release moment (\" click \") is shown separately in the display and can be deleted either manually or automatically after a set time has elapsed. Thanks to freely adjustable alarm values, the torque measuring device can warn the tester of overload of the torque tool if it does not trigger itself. For a more detailed analysis of the torsional forces, the PC software included in the scope of delivery can be used.\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Left \/ right torsion measurement\u003cbr\u003e- 1600 Hz sampling rate\u003cbr\u003e- Error limit 0.5% of the measuring range\u003cbr\u003e- PEAK \/ Hold function\u003cbr\u003e- Graphic display\u003cbr\u003e- PC software\u003cbr\u003e- Power adapter and battery operation possible\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable cellspacing=\"0\" border=\"0\" bgcolor=\"#FFFFFF\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eMeasuring range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e\u003cspan\u003e0 ... 100 Nm \/ 73.76 ft-lb (Depending on model)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0.1 Nm \/ 0.0738 ft-lb\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± 0.5% of the measuring range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eUnits of measurement\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eNm, lbfft, kgfm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eTorque sensor mount\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e1\/2\" (12.5 x 12.5 mm) internal square\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eTorsion measurement\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eLeft \/ Right\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e2.8\" TFT graphic display\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eAlarm modes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eInside Outside\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eSampling rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e6 ... 1600 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eStorage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eFor 100 measurement series with 8,000 measurement points each\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003ePower supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eNiMh battery, 6V \/ 1600-mAh\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eBattery life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eAbout 10 hours\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003ePower supply \/ charging adapter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e12V \/ 1 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eOutputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cspan\u003eInterface: USB\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eSwitching output: 12V \/ 50-mA\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eProtection class\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eIP 54\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eOperating and storage conditions   \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cspan\u003e-10 ... 50°C \/ 14 ... 122\u003c\/span\u003e°F\u003cbr\u003e\u003cspan\u003e5 ... 95% RH non-condensing\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eTorque transducer dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cspan\u003eH 85 mm \/ Ø 72 mm \/ Ø 104 mm (H 3.3 in \/ Ø 2.8 in \/ Ø 4.1 in)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e(see technical drawing)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eSensor cable length \/ td\u0026gt;\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eApprox. 1.5 m \/ 4.9 ft\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eDimensions handset\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e200 x 97 x 42 mm \/ 7.9 x 3.8 x 1.7 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eWeight handset\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e540 g \/ 1.2 lbs \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eWeight of the torsion transducer                                  \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e985 g \/ 2.2 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Torque meter PCE-DFG N \u003cstrong\u003e\u003cspan\u003e(Depending on model)\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e1 x Torque transducer 100 Nm\u003cbr\u003e1 x 1.5 m \/ 4.9 ft sensor cable\u003cbr\u003e1 x PC software\u003cbr\u003e1 x USB data cable\u003cbr\u003e1 x Power supply\u003cbr\u003e1 x Carrying case\u003cbr\u003e1 x Sensor screw socket\u003cbr\u003e1 x Instruction manual\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding \/ PCE-DFG N 5TW (5Nm)","offer_id":48427055972581,"sku":"PCE-DFG N 100TW","price":4580.0,"currency_code":"NZD","in_stock":true},{"title":"Excluding \/ PCE-DFG N 10TW (10Nm)","offer_id":48427056005349,"sku":null,"price":4580.0,"currency_code":"NZD","in_stock":true},{"title":"Excluding \/ PCE-DFG N 50TW (50Nm)","offer_id":48427056038117,"sku":null,"price":4580.0,"currency_code":"NZD","in_stock":true},{"title":"Excluding \/ PCE-DFG N 100TW (100Nm)","offer_id":48427056070885,"sku":null,"price":4580.0,"currency_code":"NZD","in_stock":true},{"title":"Including \/ PCE-DFG N 5TW (5Nm)","offer_id":48427056103653,"sku":null,"price":5110.0,"currency_code":"NZD","in_stock":true},{"title":"Including \/ PCE-DFG N 10TW (10Nm)","offer_id":48427056136421,"sku":null,"price":5110.0,"currency_code":"NZD","in_stock":true},{"title":"Including \/ PCE-DFG N 50TW (50Nm)","offer_id":48427056169189,"sku":null,"price":5110.0,"currency_code":"NZD","in_stock":true},{"title":"Including \/ PCE-DFG N 100TW (100Nm)","offer_id":48427056201957,"sku":null,"price":5110.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-torque-meter-pce-dfg-n-10tw-ica-incl.-iso-calibration-certificate-5947665_1512412.webp?v=1788142762"},{"product_id":"torque-meter-pce-ctt-10","title":"Bottle Cap Torque Tester PCE-CTT","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eTorque Meter PCE-CTT 10\u003cbr\u003eTorque meter for drinking bottles for sample sizes up to 200 mm (7.9 in) \/ Software for analysis \/\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eLeft and right direction of rotation \/ Rubberized holder device \/ Statistical evaluation\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003eThe torque meter for drinking bottles was developed to determine the torque of screw caps on drinking bottles and similar containers in a stationary manner. This measurement with the torque meter for drinking bottles is particularly important to find out whether the containers are properly closed. If the containers are not properly closed, the food they contain could rot prematurely, for example. Therefore, this measuring method with the torque meter for drinking bottles is particularly necessary in the food industry.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eIt doesn't matter whether the bottle torque meter is used in the laboratory or in production. The turntable of the torque meter for drinking bottles can hold samples with a diameter between 20 and 200 mm. A crank attached to the side of the torque meter for drinking bottles enables stepless and flexible adjustment of the transducer. Thanks to the crank, samples can be mounted quickly and easily.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eVarious functions are available for the analysis of the torque meter for drinking bottles. For example, the current measured values can be displayed on the torque meter for drinking bottles. The peak value (PEAK) can also be displayed on the torque meter for drinking bottles.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eA direct connection to a PC can be established via the USB interface on the torque meter for drinking bottles. The software can then be used to depict a graphical and tabular course of the measurement process from the torque meter for drinking bottles. The measurement data stored by the torque meter for drinking bottles can also be called up and processed using the software.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eThe recorded measurement data can be printed out at the touch of a button via the printer integrated on the side of the torque meter for drinking bottles. In order not to print all memory locations at the same time, the torque meter for drinking bottles offers the option of limiting the memory locations when printing.\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHighlights\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Accuracy of 0.3% of the measuring range\u003cbr\u003e- USB interface for software connection\u003cbr\u003e- Different units can be set\u003cbr\u003e- Samples can be clamped without tools\u003cbr\u003e- Integrated printer\u003cbr\u003e- Rubberized brackets\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSpecification\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable cellspacing=\"0\" border=\"0\" bgcolor=\"#FFFFFF\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eMeasuring range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e10 Nm \/ 7.4 ft-lb\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.005 Nm \/ 0.0037 ft-lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.3% of the measuring range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eUnit\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eNm, kgFcm, lbFin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDirection of rotation\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eLeft and right direction of rotation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eClamping pins \/ sample grips\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eRubberized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eData memory\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eFor up to 100 measured values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eInterface\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDisplay\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eLCD graphic display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePower supply\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e230V \/ 110V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eSample size\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e20 ... 200 mm \/ 0.8 ... 7.9 in, in diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" valign=\"top\"\u003eSample weight\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" valign=\"top\"\u003emax. 5 kg \/ 11 lb\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAmbient conditions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e5 ... 45°C \/ 41 ... 113°F, 35 ... 65 % r.H.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e280 x 210 x 200 mm \/ 11 x 8.3 x 7.9 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eCa. 9 kg \/ 19 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDelivery Scope\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Torque meter for drinking bottles PCE-CTT 10\u003cbr\u003e1 x USB cable\u003cbr\u003e1 x IEC cable\u003cbr\u003e1 x Software\u003cbr\u003e1 x M6 hexagon socket\u003cbr\u003e1 x M5 hexagon socket\u003cbr\u003e4 x Rubber feet\u003cbr\u003e4 x Rubberized sample holders\u003cbr\u003e1 x Instruction manual\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-files\"\u003e\n\u003ch1 class=\"headline\"\u003eDownloads\u003c\/h1\u003e\n\u003cdiv class=\"pkdownloads\"\u003e\n\u003cdiv\u003e\n\u003ca class=\"\" href=\"https:\/\/www.pce-instruments.com\/english\/api\/getartfile?_fnr=1597241\u0026amp;_dsp=inline\" target=\"_blank\"\u003e\u003cbr\u003e\u003cspan class=\"mimetitle mimetitlet_custom_manual mimetitlel_EN\"\u003eManual\u003c\/span\u003e\u003c\/a\u003e\u003ca class=\"\" href=\"https:\/\/www.pce-instruments.com\/english\/api\/getartfile?_fnr=1563368\u0026amp;_dsp=inline\" target=\"_blank\"\u003e\u003cbr\u003e\u003cspan class=\"mimetitle mimetitlet_custom_datasheet mimetitlel_EN\"\u003eDatasheet\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"PCE","offers":[{"title":"PCE-CTT 2 (2 Nm)","offer_id":48427056398565,"sku":"PCE-CTT (Bottle Testing)","price":5410.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-CTT 5 (5 Nm)","offer_id":48427056431333,"sku":null,"price":5410.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-CTT 10 (10 Nm)","offer_id":48427056464101,"sku":null,"price":5410.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-torque-meter-pce-ctt-2-5947479_1510682.webp?v=1788142760"},{"product_id":"hydraulic-force-gauges-pce-hfg-2-5k","title":"Hydraulic Force Gauge PCE-HFG Series","description":"\u003cp\u003eThe \u003cstrong\u003ePCE-HFG series\u003c\/strong\u003e is a hydraulic force gauge designed to measure forces ranging 1000, 2,500, 10 000, 25 000 N  with an extended measuring range. It is ideal for industrial applications where accurate force measurement is crucial.\u003c\/p\u003e\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExtended measuring range for high-force applications\u003c\/li\u003e\n\u003cli\u003eHydraulic measurement principle for accuracy and reliability\u003c\/li\u003e\n\u003cli\u003eDurable design for tough industrial environments\u003c\/li\u003e\n\u003cli\u003eClear analog display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003eSpecifications\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring Range:\u003c\/strong\u003e 0 ... 25000 N (Depending on Model)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 10 N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±1.0% of the measuring range\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDelivery Scope:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x PCE-HFG (Depending on Model)\u003c\/li\u003e\n\u003cli\u003e1 x Carrying Case\u003c\/li\u003e\n\u003cli\u003e1 x User Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding \/ PCE-HFG 1K-E100","offer_id":48427056562405,"sku":"PCE-HFG 2.5K","price":1930.0,"currency_code":"NZD","in_stock":true},{"title":"Excluding \/ PCE-HFG 2.5K-E100","offer_id":48427056595173,"sku":null,"price":1930.0,"currency_code":"NZD","in_stock":true},{"title":"Excluding \/ PCE-HFG 10K-E100","offer_id":48427056627941,"sku":null,"price":1940.0,"currency_code":"NZD","in_stock":true},{"title":"Excluding \/ PCE-HFG 25K-E100","offer_id":48427056660709,"sku":null,"price":1940.0,"currency_code":"NZD","in_stock":true},{"title":"Including \/ PCE-HFG 1K-E100","offer_id":48427056693477,"sku":null,"price":2360.0,"currency_code":"NZD","in_stock":true},{"title":"Including \/ PCE-HFG 2.5K-E100","offer_id":48427056726245,"sku":null,"price":2360.0,"currency_code":"NZD","in_stock":true},{"title":"Including \/ PCE-HFG 10K-E100","offer_id":48427056759013,"sku":null,"price":2360.0,"currency_code":"NZD","in_stock":true},{"title":"Including \/ PCE-HFG 25K-E100","offer_id":48427056791781,"sku":null,"price":2370.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-hydraulic-force-gauges-pce-hfg-2.5k-e100-ica-incl.-iso-calibration-certificate-6108217_2674976.webp?v=1788142757"},{"product_id":"hydraulic-force-gauges-pce-hfg-2-5k-e100","title":"Hydraulic Force Gauge PCE-HFG 2.5K-E100","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eHydraulic Force Gauges\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ehydraulic force gauges with analog scale \/ Compact for small installation spaces \/\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eDrag pointer \/ With mounting holes \/ 27 mm ring opening\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv\u003eA force measuring device is based on the principle that the force acting on the pressure adapter is measured hydraulically. The hydraulic pressure generated is displayed by the force measuring device on a scale in Newtons. With the integrated drag pointer, our force measuring device can display the respective maximum measured value.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eAnother special feature of the force measuring device is the 27 mm ring opening. With this ring opening, measurements can be carried out with the force measuring device on, for example, guide rails, shafts and also bolts of, for example, a hydraulic press. With the insertable punch adapter, the force measuring device can be converted from a ring force measuring device into a pressure punch force measuring device in a matter of seconds. The force transducer can therefore be used flexibly.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eA force measuring device is used wherever forces act that are to be measured. A force measuring device is therefore ideally suited for maintenance measurements and adjustment work on, for example, industrial machines.\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Stainless steel force gauge\u003cbr\u003e- Measurement of static compressive forces\u003cbr\u003e- Ring force transducer and pressure adapter\u003cbr\u003e- Screw mount for axial assembly\u003cbr\u003e- Integrated drag pointer\u003cbr\u003e- Pressure force display in Newton [N]\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0 … 2,500 N \/ 562 lbs\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100 N \/ 22.5 lbs\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.95% f. R.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydraulic hose\u003c\/td\u003e\n\u003ctd\u003elength 100 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions of the display         \u003c\/td\u003e\n\u003ctd\u003eØ 55 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting holes\u003c\/td\u003e\n\u003ctd\u003e2 x M6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient conditions\u003c\/td\u003e\n\u003ctd\u003e0 … 50°C \/ 32 ... 122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Hydraulic Force Gaugess PCE-HFG 2.5K-E100\u003cbr\u003e1 x Instrument case\u003cbr\u003e1 x Compression adapter\u003cbr\u003e1 x Instruction manual\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding ISO Calibration","offer_id":48427056857317,"sku":"PCE-HFG 2.5K-E100","price":1930.0,"currency_code":"NZD","in_stock":true},{"title":"Including ISO Calibration","offer_id":48427056890085,"sku":"PCE-HFG 2.5K-E100-ICA","price":2360.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-hydraulic-force-gauges-pce-hfg-2.5k-ica-incl.-iso-calibration-certificate-6050987_2369728_f1c87483-8db2-47e1-a037-1fff980ea36e.webp?v=1788142755"},{"product_id":"pressure-gauge-pce-dpg-10","title":"Digital Manometer PCE-DPG","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eManometer PCE-DPG 3-ICA incl. ISO Calibration Certificate\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePressure sensor for water and gases \/ 1\/4\" NPT threaded connection \/ Adjustable backlight \/ PEAK function \/ Battery status indicator \/ Battery-operated\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv\u003eThe manometer of the PCE-DPG series is well suited for monitoring and displaying air pressure and water pressure. Thanks to its high measuring resolution and high accuracy, this manometer is versatile. The current pressure is displayed by the manometer as a value and at the same time as a bar graph. As an additional function, the manometer offers a peak function. This function shows the operator the maximum and minimum pressure measured on the manometer at the push of a button.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eThanks to the large display of 2.5\" almost all measured values ​​can be read directly. Possible adjustable units for the manometer would be Mpa, bar, Kpa, mH2o, kg \/ cm2, psi, mmH2o, in.WC and mbar. The response time of the manometer is \u0026lt; 50 ms. The connection of the manometer to the process is realized via a 1\/4\" NPT connection. Typical applications include suction control, leak testing or pressure monitoring.\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Measuring range up to 3\/ 6\/ 10\/ 100\/ 200 Bar (Depending on model)\u003cbr\u003e- Scaled bar graph\u003cbr\u003e- Battery powered 3 x 1.5V AAA\u003cbr\u003e- Large 2.5\" display\u003cbr\u003e- Adjustable backlight\u003cbr\u003e- 1.4\" NPT connection thread\u003cbr\u003e- incl. ISO Calibration Certificate\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e3\/ 6\/ 10\/ 100\/ 200 Bar (Depending on model)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.0145 psi, 0.001 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.25% FSO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure\u003c\/td\u003e\n\u003ctd\u003erelative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverpressure\u003c\/td\u003e\n\u003ctd\u003e1.5 times\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurable media\u003c\/td\u003e\n\u003ctd\u003egases, water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing material\u003c\/td\u003e\n\u003ctd\u003emetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement units\u003c\/td\u003e\n\u003ctd\u003eMpa, bar, Kpa, mH2o, kg \/ cm²,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003epsi, mmH2o, in.WC, mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIP56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiameter display\u003c\/td\u003e\n\u003ctd\u003e2.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (without sensor)   \u003c\/td\u003e\n\u003ctd\u003eØ80 x 50 mm \/ 3.1 x 2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure connection\u003c\/td\u003e\n\u003ctd\u003e1\/40\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e3 x 1.5V AAA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental conditions\u003c\/td\u003e\n\u003ctd\u003e-10 ... 60°C \/ 14 ... 140°F, \u0026lt; 80% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eapprox. 276 g \/ \u0026lt; 1 lb (without batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cp\u003e1 x Manometer PCE-DPG 3\/ 6\/ 10\/ 100\/ 200 Bar (Depending on model)\u003cbr\u003e3 x Batteries 1.5V AAA\u003cbr\u003e1 x Operating instructions\u003cbr\u003e1 x ISO Calibration Certificate (Optional)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding \/ PCE-DPG 3 Bar (43.5psi)","offer_id":48427056955621,"sku":"PCE-DPG 10","price":1090.0,"currency_code":"NZD","in_stock":true},{"title":"Excluding \/ PCE-DPG 6 Bar (87psi)","offer_id":48427056988389,"sku":null,"price":1090.0,"currency_code":"NZD","in_stock":true},{"title":"Excluding \/ PCE-DPG 10 Bar (145psi)","offer_id":48427057021157,"sku":null,"price":1090.0,"currency_code":"NZD","in_stock":true},{"title":"Excluding \/ PCE-DPG 100 Bar (1450psi)","offer_id":48427057053925,"sku":null,"price":1090.0,"currency_code":"NZD","in_stock":true},{"title":"Excluding \/ PCE-DPG 200 Bar (2900psi)","offer_id":48427057086693,"sku":null,"price":1090.0,"currency_code":"NZD","in_stock":true},{"title":"Including \/ PCE-DPG 3 Bar (43.5psi)","offer_id":48427057119461,"sku":null,"price":1710.0,"currency_code":"NZD","in_stock":true},{"title":"Including \/ PCE-DPG 6 Bar (87psi)","offer_id":48427057152229,"sku":null,"price":1710.0,"currency_code":"NZD","in_stock":true},{"title":"Including \/ PCE-DPG 10 Bar (145psi)","offer_id":48427057184997,"sku":null,"price":1710.0,"currency_code":"NZD","in_stock":true},{"title":"Including \/ PCE-DPG 100 Bar (1450psi)","offer_id":48427057217765,"sku":null,"price":1710.0,"currency_code":"NZD","in_stock":true},{"title":"Including \/ PCE-DPG 200 Bar (2900psi)","offer_id":48427057250533,"sku":null,"price":1710.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-pressure-gauge-pce-dpg-100-ica-incl.-iso-calibration-certificate-5953538_2730201_1.webp?v=1788142754"},{"product_id":"differential-pressure-gauge-pce-917","title":"Air \u0026 Gas Pressure Gauge PCE-917","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cp align=\"center\"\u003e\u003cstrong\u003ePCE-917 Differential Pressure Gauge incl. ISO calibration certificate\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePortable handheld manometer measures differential pressure from ± 5 to 7000 mbar (± 0.05 \/ 0.1 to 101.5 psi) \/ Optional PC software with RS-232 cable sold separately as a data transfer accessory\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003ePCE-917 is a portable handheld digital differential pressure gauge, meter or manometer used to measure differential pressure in pneumatic, compressor and pump installations, valves, tanks and heating, ventilation and air conditioning (HVAC) systems. The PCE-917 features a dust-proof, splash-resistant housing, allowing the meter to be used under adverse conditions.\u003c\/p\u003e\n\u003cp\u003eThe PCE-917 differential pressure manometer comes with 1 x 1 m \/ 3 ft long silicon tube, 2 x stainless steel tube adapters and 1 x 9V block battery. Optional PC software with RS-232 cable sold separately as a data transfer accessory. The software can be used to transmit the data to a computer for evaluating, documenting and storing pressure fluctuations. Simply connect the differential manometer via RS-232 to your computer for analysis. If your computer doesn't have an RS-232 interface, you may acquire an RS-232 to USB adapter (see accessories tab for details).\u003c\/p\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- ± 5 to 7000 mbar (± 0.05 \/ 0.1 to 101.5 psi) measuring range\u003cbr\u003e- 10 measurement units: psi, mbar, inH2O, mH2O, inHg, mmHg, Torr, Pa \/ kPa, atm, kg\/cm²\u003cbr\u003e- Designed to measure air, gas and non-corrosive liquid pressures\u003cbr\u003e- Min, max and data hold functions\u003cbr\u003e- RS-232 port \/ interface\u003cbr\u003e- 15 mm \/ 0.6 in LCD screen\u003cbr\u003e- Optional PC software with RS-232 cable sold separately as a data transfer accessory\u003cbr\u003e-\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eIncl. ISO calibration certificate\u003c\/strong\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable border=\"0\" bgcolor=\"#FFFFFF\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003embar\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eResolution: 5\u003cbr\u003eRange: ± 7000\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003epsi\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eResolution: 0.05 \/ 0.1\u003cbr\u003eRange: ± 101.5\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003einH2O\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eResolution: 2\u003cbr\u003eRange: ± 2800\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003emH2O\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eResolution: 0.05\u003cbr\u003eRange: ± 70.00\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003einHg\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eResolution: 0.1\u003cbr\u003eRange: ± 206.0\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003emmHg\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eResolution: 5\u003cbr\u003eRange: ± 5250\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eTorr\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eResolution: -\u003cbr\u003eRange: -\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePa \/ kPa\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eResolution: -\u003cbr\u003eRange: -\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eatm\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eResolution: 0.005\u003cbr\u003eRange: ± 6.905\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ekg\/cm²\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eResolution: 0.005\u003cbr\u003eRange: ± 7.000\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e± 2% (full range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eReproducibility\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e± 1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResponse time\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.8 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eInterface\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eRS-232 port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePower supply\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 x 9V block battery\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eHousing material\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003ePlastic\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eHousing dimensions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eApprox. 180 x 72 x 32 mm \/ 7.09 x 2.84 x 1.26 in\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eApprox. 210 g \/ \u0026lt; 1 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eWarning:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e***Exceeding the maximum pressure range will destroy the sensor***\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e1 x PCE-917 differential pressure gauge\u003cbr\u003e1 x 9V block battery\u003cbr\u003e2 x Stainless steel tube adapters\u003cbr\u003e1 x 1 m \/ 3 ft long silicon tube\u003cbr\u003e1 x User manual\u003c\/div\u003e\n\u003cstrong\u003e1 x ISO calibration certificate\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding ISO Calibration","offer_id":48427057512677,"sku":"PCE-917","price":960.0,"currency_code":"NZD","in_stock":true},{"title":"Including ISO Calibration","offer_id":48427057545445,"sku":"PCE-917-ICA","price":1570.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-differential-pressure-gauge-pce-917-ica-incl.-iso-calibration-certificate-5886058_1235526_1.webp?v=1788142752"},{"product_id":"differential-pressure-meter-pressure-gauge-pce-p01","title":"Digital Differential Pressure Meter PCE-P01","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eDifferential Pressure\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003eGauge PCE-P01-ICA incl. ISO Calibration Certificate\u003cbr\u003eDifferential manometer for the measuring range from -140 to +140 mbar, including software\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\nThe differential pressure gauge PCE-P01 is a robust, compact and comprehensive differential pressure gauge for measuring pressure in 11 adjustable units. The PCE-P01 is particularly suitable for the complete documentation of your measuring tasks. The minimum, maximum and average values of your measurement can be viewed in parallel to the current measured value on the large display of the PCE-P01 differential meter. For example, if you want to determine and document pressure fluctuations, you can use the enclosed software, with the help of which it is possible, for example, to transfer the measured values to the computer every second and display them graphically and in tabular form.\u003cbr\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Easiest operation\u003cbr\u003e- Measurement of differential pressure and static pressure in 11 selectable units: mbar, bar, psi, kPa, ...\u003cbr\u003e- Measuring range from -140 to +140 mbar\u003cbr\u003e- Min \/ max and average value display\u003cbr\u003e- \"Hold\" function\u003cbr\u003e- Backlight can be switched on \/ off\u003cbr\u003e- For long-term measurements including power supply\u003cbr\u003e- Software with USB cable included\u003cbr\u003e- Battery level indicator\u003cbr\u003e- Auto-off function that can be switched off\u003cbr\u003e- Zero point adjustment possible at any time\u003cbr\u003e-\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eincl. ISO Calibration Certificate\u003c\/strong\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003e\u003cstrong\u003eMeasuring range \u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e (\u003c\/span\u003e\u003cspan\u003e±)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003einH2O \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003epsi \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003embar \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ekPa \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003einHg \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003emmHg \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eozin² \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eftH2O \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ecmH2O \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ekgcm² \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ebar\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e55.40 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e2.000 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e137.8 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e13.79 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e4.072 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e103.4 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e32.00 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e4.612 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e140.6 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.140 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.137\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003e\u003cstrong\u003eResolution  \u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003einH2O \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003epsi \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003embar \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ekPa \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003einHg \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003emmHg \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eozin² \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eftH2O \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ecmH2O \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ekgcm² \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ebar\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e0.01 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.001 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.1 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.01 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.001 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.1 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.01 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.001 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.1 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.001 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.001\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy (at +25 °C \/ +77 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e± 0.3%\u003c\/span\u003e\u003cspan\u003e of measuring range\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinearity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e± 0.2%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResponse time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 0.5 sec.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax. pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e689 mbar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 ... 50°C \/ 32 ... 122°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 ... 60°C \/ 14 ... 140°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMedia\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAir and non-explosive gases\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eReal-time data-logging interval    \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 sec. to 24 h adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual LCD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e210 x 75 x 50 mm \/ 8.27 x 2.95 x 1.97 in (H x W x D)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight (without batteries)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e650 g \/ 1.44 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eBattery: 1 x 9V block \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eAC adapter: 9V DC \/ 500-mA \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cp\u003e1 x Pressure Gauge PCE-P01\u003cbr\u003e4 x 30cm \/ 11.8\" silicone hose\u003cbr\u003e1 x Software including USB cable\u003cbr\u003e1 x 9V block battery\u003cbr\u003e1 x 9V DC power supply\u003cbr\u003e1 x Plastic case\u003cbr\u003e1 x User manual\u003cbr\u003e1 x ISO Calibration Certificate\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding ISO Calibration","offer_id":48427057610981,"sku":"PCE-P01","price":620.0,"currency_code":"NZD","in_stock":true},{"title":"Including ISO Calibration","offer_id":48427057643749,"sku":"PCE-P01-ICA","price":1150.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-pressure-gauge-pce-p01-ica-incl.-iso-calibration-certificate-5953752_1585827_d7d7c40d-80c2-4754-8a33-80d494413c67.webp?v=1788142750"},{"product_id":"differential-pressure-meter-pressure-gauge-pce-p05","title":"Digital Differential Pressure Meter PCE-P05","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cp align=\"center\"\u003e\u003cstrong\u003ePCE-P05 Differential Pressure Meter incl. ISO calibration certificate\u003cbr\u003ePortable handheld manometer measures differential pressure from \u003c\/strong\u003e\u003cspan\u003e-\u003c\/span\u003e\u003cspan\u003e0.344 to 0.344 bar (-5.000 to 5.000 psi)\u003c\/span\u003e\u003cstrong\u003e \/ Features real-time data-logging capabilities using the included PC software and USB cable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003ePCE-P05 is a portable handheld digital differential pressure meter or manometer used to measure differential pressure in pneumatic, compressor and pump installations, valves, tanks and heating, ventilation and air conditioning (HVAC) systems. The PCE-P05 displays min \/ max \/ average values right on the meter's screen for comparison against current measurement values.\u003c\/p\u003e\n\u003cp\u003eIn addition, the PCE-P05 differential pressure manometer features real-time data-logging capabilities with an adjustable interval from 1 second to 24 hours. The device comes with 4 x 30 cm \/ 11.81 in silicon tubes, 1 x 9V block battery and 1 x AC power adapter. Also included in the delivery contents are PC-compatible software and a USB cable. The software can be used to detect and document pressure fluctuations, and to display the data graphically or in a table. For real-time data recording, simply connect the differential manometer via USB to your computer, and save the measured values ​​according to your selected time interval. You can then calculate average values ​​directly in the software or export the saved data to Microsoft Excel.\u003c\/p\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Easiest operation\u003cbr\u003e- 11 selectable units: mbar, bar, psi, kPa, ...\u003cbr\u003e- Measuring range from -344 ... +344 mbar \/ -5.000 to +5.000 psi\u003cbr\u003e- Min \/ max and average value display\u003cbr\u003e- \"Hold\" function\u003cbr\u003e- Backlight can be switched on \/ off\u003cbr\u003e- For long-term measurements including power supply\u003cbr\u003e- Software with USB cable included\u003cbr\u003e- Battery level indicator\u003cbr\u003e- Auto-off function that can be switched off\u003cbr\u003e- Zero point adjustment possible at any time\u003cbr\u003e-\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eincl. ISO Calibration Certificate\u003c\/strong\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003e\u003cstrong\u003eMeasuring range\u003c\/strong\u003e \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003einH2O \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003epsi \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003embar \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ekPa \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003einHg \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003emmHg \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eozin² \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eftH2O \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ecmH2O \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ekgcm² \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ebar\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e (±)\u003cbr\u003e138.30 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e5.000 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e344.7 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e34.47 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1.018 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e258.5 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e80.00 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e11.53 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e351.5 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.351 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.344\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003eResolution  \u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003einH2O \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003epsi \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003embar \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ekPa \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003einHg \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003emmHg \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eozin² \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eftH2O \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ecmH2O \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ekgcm² \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ebar\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e\u003cbr\u003e\u003cbr\u003e0.1 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.001 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.1 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.01 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.001 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.1 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.01 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.001 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.1 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.001 \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e0.001\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy (at +25 °C \/ +77 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e± 0.3%\u003c\/span\u003e\u003cspan\u003e of measuring range\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinearity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e± 0.2%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResponse time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 0.5 sec.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax. pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1378 mbar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 ... 50°C \/ 32 ... 122°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 ... 60°C \/ 14 ... 140°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMedia\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAir and non-explosive gases\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eReal-time data-logging interval    \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 sec. to 24 h adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual LCD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e210 x 75 x 50 mm \/ 8.27 x 2.95 x 1.97 in (H x W x D)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight (without batteries)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e650 g \/ 1.44 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eBattery: 1 x 9V block \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eAC adapter: 9V DC \/ 500-mA \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\u003cbr\u003eSee user manual for complete technical specifications.\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cp\u003e1 x Differential Pressure Meter PCE-P05\u003cbr\u003e4 x 30cm \/ 11.8\" silicone hose\u003cbr\u003e1 x Software including USB cable\u003cbr\u003e1 x 9V block battery\u003cbr\u003e1 x 9V DC power supply\u003cbr\u003e1 x Plastic case\u003cbr\u003e1 x User manual\u003cbr\u003e1 x ISO Calibration Certificate\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding ISO Calibration","offer_id":48427057709285,"sku":"PCE-P05","price":690.0,"currency_code":"NZD","in_stock":true},{"title":"Including ISO Calibration","offer_id":48427057742053,"sku":"PCE-P05-ICA","price":1200.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-pressure-gauge-pce-p01-ica-incl.-iso-calibration-certificate-5953752_1585827_6512263a-5f90-4443-b99d-4befc20d537a.webp?v=1788142749"},{"product_id":"differential-pressure-meter-pressure-gauge-pce-p30","title":"Digital Differential Pressure Meter PCE-P30","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\u003cstrong\u003eHVAC Meter PCE-P30-ICA with RS232 interface and software, for overpressure, underpressure, differential pressure, suitable for air and gases \/ incl. ISO calibration certificate\u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003eHere you can see a professional differential pressure HVAC meter with the highest accuracy and best performance. With this differential manometer you can not only measure. The pressure readings can easily be transferred online to a PC or laptop. The differential pressure gauge is ideal for use in industry, in service and in the laboratory. The device is particularly suitable for measuring non-corrosive media. The overload protection is twice the measuring range. The 9 units that can be shown on the display make this differential manometer universally applicable for the practitioner on site and saves laborious conversion of the measurement results (conversion table of the pressure units).\u003cbr\u003e \u003cbr\u003eIf you want to transfer the measurement data from the differential manometer to the computer, you need the optional software and the RS-232 interface cable. The software runs in conjunction with the Windows® versions `95,` 98, `2000 and ME \/ XP (short info: pressure measuring device with interface). The principle of absolute and differential pressure measurement is explained if you follow the link below: Principle of absolute and differential pressure measurement. DIN ISO 9000 calibration certificates for the pressure gauges and corresponding accessories are also available.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThe software for data transfer and the interface cable can optionally be ordered as a package. The differential manometer is connected to the PC with the RS-232 cable. The software is installed from the CD. The pictures below give you an optical impression of the software. The differential manometer transmits the respective measured values ​​online to the PC.\u003cbr\u003e\u003cbr\u003eThe values ​​determined on the differential manometer are plotted directly on the y-axis. The differential pressure values ​​are indicated with \"-\" in a field below the graphic (visible on the top left picture (in the red circle)). The measuring units can be changed to the desired unit both on the differential manometer and in the software. All measured values ​​are written in a data file and can be saved under any name on the hard disk of the computer. Many customers also transfer the values ​​to e.g. MS Excel for further analysis.\u003cbr\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- 9 selectable units\u003cbr\u003e- Digital display of over, under (vacuum) or differential pressure\u003cbr\u003e- Min \/ Max memory\u003cbr\u003e- Data hold function\u003cbr\u003e- Backlit LCD display\u003cbr\u003e- Impact-resistant ABS housing\u003cbr\u003e- Auto-power-off function\u003cbr\u003e-\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIncl. ISO calibration certificate\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFurther areas of application\u003c\/strong\u003e\u003cbr\u003eThe applications of the differential manometer are diverse.\u003cbr\u003eFor example, it is used in:\u003cbr\u003e\u003cbr\u003e- Pneumatic area, on compressors and pumping systems\u003cbr\u003e- Chemical area for process control, measurements on pressure tanks\u003cbr\u003e- Manufacturing area, for compressed air press processes e.g. in the plastics industry\u003cbr\u003e- Checking valve controls (before- after- loss of compressed air)\u003cbr\u003e- Research and development area\u003cbr\u003e- In general for optimization and testing in the process\u003cbr\u003e- Authorization area for heating and air conditioning systems\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Meter \u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003ePCE-P30\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Pressure\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003epositive\/ negative\u003cbr\u003eor overpressure \/ vacuum \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e60 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePSI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003embar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003einH\u003c\/strong\u003e\u003csub\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/sub\u003e\u003cstrong\u003e0\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±830\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003einHg\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emmHg\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ekPa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003ecmH\u003c\/strong\u003e\u003csub\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/sub\u003e\u003cstrong\u003e0\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±2100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKg\/cm²\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±2.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eData format\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eBaud rate: 2400 baud,1 stop bit, 8 data bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.3 % (full range, @ +25°C \/ +77°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.2 % (max. ±0.5 % of full scale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eDuration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.3 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eOperating temperature max\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+50 °C \/ +122 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eBattery\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 x 9 V - block battery PP3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eDimensions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e182 x 72 x 30 mm \/ 7.1 x 2.8 x 1.1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e150 g \/ 5.3 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x HVAC Meter PCE-P30-ICA Differential Pressure\u003cbr\u003e1 x Carrying case\u003cbr\u003e1 x Battery\u003cbr\u003e1 x PVC hose (1 m \/ 39\")\u003cbr\u003e1 x Instruction manual\u003cbr\u003e1 x Protective cover\u003cbr\u003e1 x\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eISO calibration certificate\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eWarning\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eOverloading destroys the sensor in the PCE-P30 pressure measuring device\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding ISO Calibration","offer_id":48427057807589,"sku":"PCE-P30","price":860.0,"currency_code":"NZD","in_stock":true},{"title":"Including ISO Calibration","offer_id":48427057840357,"sku":"PCE-P30-ICA","price":1350.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-hvac-meter-pce-p30-differential-pressure-incl.-iso-calibration-certificate-5886124_1235932_55d5cc9f-6e4f-45aa-b79f-430f388f3110.webp?v=1788142747"},{"product_id":"differential-pressure-meter-pressure-gauge-pce-p50","title":"Digital Differential Pressure Meter PCE-P50","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\u003cstrong\u003eDifferential Pressure Meter PCE-P50-ICA with RS232 interface and software, for overpressure, underpressure, differential pressure, suitable for air and gases \/ incl. ISO calibration certificate\u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003eHere you can see a professional differential pressure meter with the highest accuracy and best performance. With this differential manometer you can not only measure. The pressure readings can easily be transferred online to a PC or laptop. The differential pressure gauge is ideal for use in industry, in service and in the laboratory. The device is particularly suitable for measuring non-corrosive media. The overload protection is twice the measuring range. The 9 units that can be shown on the display make this differential manometer universally applicable for the practitioner on site and saves laborious conversion of the measurement results (conversion table of the pressure units).\u003cbr\u003e \u003cbr\u003eIf you want to transfer the measurement data from the differential manometer to the computer, you need the optional software and the RS-232 interface cable. The software runs in conjunction with the Windows® versions `95,` 98, `2000 and ME \/ XP (short info: pressure measuring device with interface). The principle of absolute and differential pressure measurement is explained if you follow the link below: Principle of absolute and differential pressure measurement. DIN ISO 9000 calibration certificates for the pressure gauges and corresponding accessories are also available.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThe software for data transfer and the interface cable can optionally be ordered as a package. The differential manometer is connected to the PC with the RS-232 cable. The software is installed from the CD. The pictures below give you an optical impression of the software. The differential manometer transmits the respective measured values ​​online to the PC.\u003cbr\u003e\u003cbr\u003eThe values ​​determined on the differential manometer are plotted directly on the y-axis. The differential pressure values ​​are indicated with \"-\" in a field below the graphic (visible on the top left picture (in the red circle)). The measuring units can be changed to the desired unit both on the differential manometer and in the software. All measured values ​​are written in a data file and can be saved under any name on the hard disk of the computer. Many customers also transfer the values ​​to e.g. MS Excel for further analysis.\u003cbr\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- 9 selectable units\u003cbr\u003e- Digital display of over, under (vacuum) or differential pressure\u003cbr\u003e- Min \/ Max memory\u003cbr\u003e- Data hold function\u003cbr\u003e- Backlit LCD display\u003cbr\u003e- Impact-resistant ABS housing\u003cbr\u003e- Auto-power-off function\u003cbr\u003e-\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIncl. ISO calibration certificate\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFurther areas of application\u003c\/strong\u003e\u003cbr\u003eThe applications of the differential manometer are diverse.\u003cbr\u003eFor example, it is used in:\u003cbr\u003e\u003cbr\u003e- Pneumatic area, on compressors and pumping systems\u003cbr\u003e- Chemical area for process control, measurements on pressure tanks\u003cbr\u003e- Manufacturing area, for compressed air press processes e.g. in the plastics industry\u003cbr\u003e- Checking valve controls (before- after- loss of compressed air)\u003cbr\u003e- Research and development area\u003cbr\u003e- In general for optimization and testing in the process\u003cbr\u003e- Authorization area for heating and air conditioning systems\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Meter \u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003ePCE-P50\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Pressure\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003epositive\/ negative\u003cbr\u003eor overpressure \/ vacuum \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e150 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePSI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003embar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±6900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003einH\u003c\/strong\u003e\u003csub\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/sub\u003e\u003cstrong\u003e0\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±2750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003einHg\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emmHg\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±5200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ekPa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±690\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003ecmH\u003c\/strong\u003e\u003csub\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/sub\u003e\u003cstrong\u003e0\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±7000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKg\/cm²\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eData format\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eBaud rate: 2400 baud,1 stop bit, 8 data bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.3 % (full range, @ +25°C \/ +77°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.2 % (max. ±0.5 % of full scale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eDuration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.3 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eOperating temperature max\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+50 °C \/ +122 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003ePower supply\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003e9 V DC \/ power converter (optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003e1 x 9 V - block battery PP3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eDimensions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e182 x 72 x 30 mm \/ 7.1 x 2.8 x 1.1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e150 g \/ 5.3 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Differential Pressure Meter PCE-P50-ICA\u003cbr\u003e1 x Carrying case\u003cbr\u003e1 x Battery\u003cbr\u003e1 x PVC hose (1 m \/ 39\")\u003cbr\u003e1 x Instruction manual\u003cbr\u003e1 x\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eISO calibration certificate\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding ISO Calibration","offer_id":48427057905893,"sku":"PCE-P50","price":960.0,"currency_code":"NZD","in_stock":true},{"title":"Including ISO Calibration","offer_id":48427057938661,"sku":"PCE-P50-ICA","price":1460.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-hvac-meter-pce-p30-differential-pressure-incl.-iso-calibration-certificate-5886124_1235932_9d3c6f67-a572-43e3-88b7-04feda0ac8fd.webp?v=1788142745"},{"product_id":"differential-pressure-meter-pressure-gauge-pce-p15","title":"Digital Differential Pressure Meter PCE-P15","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\u003cstrong\u003eDifferential Pressure Meter PCE-P15-ICA with RS232 interface and software, for overpressure, underpressure, differential pressure, suitable for air and gases, incl. ISO calibration certificate\u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003eHere you can see a professional differential pressure meter with the highest accuracy and best performance. With this differential manometer you can not only measure. The pressure readings can easily be transferred online to a PC or laptop. The differential pressure gauge is ideal for use in industry, in service and in the laboratory. The device is particularly suitable for measuring non-corrosive media. The overload protection is twice the measuring range. The 9 units that can be shown on the display make this differential manometer universally applicable for the practitioner on site and saves laborious conversion of the measurement results (conversion table of the pressure units).\u003cbr\u003e \u003cbr\u003eIf you want to transfer the measurement data from the differential manometer to the computer, you need the optional software and the RS-232 interface cable. The software runs in conjunction with the Windows® versions `95,` 98, `2000 and ME \/ XP (short info: pressure measuring device with interface). The principle of absolute and differential pressure measurement is explained if you follow the link below: Principle of absolute and differential pressure measurement. DIN ISO 9000 calibration certificates for the pressure gauges and corresponding accessories are also available.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThe software for data transfer and the interface cable can optionally be ordered as a package. The differential manometer is connected to the PC with the RS-232 cable. The software is installed from the CD. The pictures below give you an optical impression of the software. The differential manometer transmits the respective measured values ​​online to the PC.\u003cbr\u003e\u003cbr\u003eThe values ​​determined on the differential manometer are plotted directly on the y-axis. The differential pressure values ​​are indicated with \"-\" in a field below the graphic (visible on the top left picture (in the red circle)). The measuring units can be changed to the desired unit both on the differential manometer and in the software. All measured values ​​are written in a data file and can be saved under any name on the hard disk of the computer. Many customers also transfer the values ​​to e.g. MS Excel for further analysis.\u003cbr\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- 9 selectable units\u003cbr\u003e- Digital display of over, under (vacuum) or differential pressure\u003cbr\u003e- Min \/ Max memory\u003cbr\u003e- Data hold function\u003cbr\u003e- Backlit LCD display\u003cbr\u003e- Impact-resistant ABS housing\u003cbr\u003e- Auto-power-off function\u003cbr\u003e-\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eIncl. ISO calibration certificate\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFurther areas of application\u003c\/strong\u003e\u003cbr\u003eThe applications of the differential manometer are diverse.\u003cbr\u003eFor example, it is used in:\u003cbr\u003e\u003cbr\u003e- Pneumatic area, on compressors and pumping systems\u003cbr\u003e- Chemical area for process control, measurements on pressure tanks\u003cbr\u003e- Manufacturing area, for compressed air press processes e.g. in the plastics industry\u003cbr\u003e- Checking valve controls (before- after- loss of compressed air)\u003cbr\u003e- Research and development area\u003cbr\u003e- In general for optimization and testing in the process\u003cbr\u003e- Authorization area for heating and air conditioning systems\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Meter \u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003ePCE-P15\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Pressure\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003epositive\/ negative\u003cbr\u003eor overpressure \/ vacuum \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e30 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePSI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003embar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003einH\u003c\/strong\u003e\u003csub\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/sub\u003e\u003cstrong\u003e0\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±415\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003einHg\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±30.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emmHg\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ekPa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003ecmH\u003c\/strong\u003e\u003csub\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/sub\u003e\u003cstrong\u003e0\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±1050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKg\/cm²\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0...±1.05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eData format\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eBaud rate: 2400 baud,1 stop bit, 8 data bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.3 % (full range, @ +25°C \/ +77°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.2 % (max. ±0.5 % of full scale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eDuration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.3 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eOperating temperature max\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+50 °C \/ +122 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eBattery\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 x 9 V - block battery PP3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eDimensions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e182 x 72 x 30 mm \/ 7.1 x 2.8 x 1.1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e150 g \/ 5.3 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Differential Pressure Meter PCE-P15-ICA\u003cbr\u003e1 x Carrying case\u003cbr\u003e1 x Battery\u003cbr\u003e1 x PVC hose (1 m \/ 39\")\u003cbr\u003e1 x Instruction manual\u003cbr\u003e1 x Protective cover\u003cbr\u003e1 x\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eISO calibration certificate\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding ISO Calibration","offer_id":48427058069733,"sku":"PCE-P15","price":860.0,"currency_code":"NZD","in_stock":true},{"title":"Including ISO Calibration","offer_id":48427058102501,"sku":"PCE-P15-ICA","price":1350.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-hvac-meter-pce-p30-differential-pressure-incl.-iso-calibration-certificate-5886124_1235932.webp?v=1788142744"},{"product_id":"digital-multimeter-pce-123","title":"Digital Multimeter PCE-123","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cp align=\"center\"\u003e\u003cstrong\u003eDigital, electrical, current, voltage or process calibrator, tester or multimeter for simulation and measurement of standardized electrical signals \/ control signals as well as frequencies and temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe PCE-123 is a network-independent multifunction calibrator used to test and calibrate a variety of parameters of controllers and measuring instruments. Offering a high level of accuracy for an affordable price, this easy-to-use calibrator provides electrical (mA, mV, V and frequency in Hz) and temperature (in °C or °F) output signals, making the calibrator useful in a wide range of applications.\u003c\/p\u003e\n\u003cp\u003eThe calibrator also has automatic step and ramp functions as well as the possibility to pre-select the output signal steps (0 … 100 %) by using the arrow keys and to directly specify an output value (e. g. 13.8 mA). Operation via the keypad is very easy and intuitive. The PCE-123 multifunctional calibrator is an important tool in any electronics workshop as well as in any measuring and control department in trade, industry and automation.\u003c\/p\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e - 4 to 20mA (1kΩ, 24V power)\u003cbr\u003e - 0 to 100.00 mV \/ 0 to 1,0000V \/ 0 to 12,000V\u003cbr\u003e - Type-K, J, E, T temperature thermocouple sensors (°C or °F)\u003cbr\u003e - Frequency range 1 to 62,500Hz\u003cbr\u003e - Basic accuracy 0.025 %\u003cbr\u003e - Easy operation via keypad\u003cbr\u003e - Automatic ramp function\u003cbr\u003e - Selectable between 0 to 20mA\/ 0 to 24mA\u003cbr\u003e - Input 0 to 100% (mA, mV, V )\u003cbr\u003e - Alarm beep 'open' (mA) or 'short circuit' (mV, V)\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003emA DC current\u003cbr\u003e(maximum load at 1kΩ, powered by 24V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e4 to 20mA \/ 0 to 20mA \/ 0 to 24mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.025% ±3µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlert\u003c\/td\u003e\n\u003ctd\u003ebeeps when there is a short circuit or ouput current \u0026gt;1mA .\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003emV current, V DC\u003cbr\u003e(power 1mA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd\u003e0 to 100.00 mV\u003cbr\u003e0 to 10.000 V\u003cbr\u003e0 to 1.0000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e10 µV\u003cbr\u003e1 mV\u003cbr\u003e1.0000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e± 0.05% ±30 µV\u003cbr\u003e± 0.05% ±3 mV\u003cbr\u003e± 0.05% ±300 µV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlert\u003c\/td\u003e\n\u003ctd\u003ebeeps when there is a short circuit or ouput current \u0026gt;10mV.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTemperature sensor thermocouple type-K, J, E, T \u003cbr\u003e(1 kΩ min.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd\u003eK: -200 ... 0 °C \/ -328 ... 32 °F and 0 ... 1370 °C \/ 32 ... 2498 °F\u003cbr\u003eJ: -100 ... 0 °C \/ -148 ... 32 °F and 0 ... 760 °C \/ 32 ... 1400 °F\u003cbr\u003eE: -10 ... 0 °C \/ 14 ... 32 °F and 0 ... 700°C \/ 32 ... 1292 °F\u003cbr\u003eT: -200 ... 0°C \/ -328 ... 32 °F and T: 0 ... 400 °C \/ 32 ... 752 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1°C (across entire range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eK: ±1.1°C and ±0.8°C\u003cbr\u003eJ:  ±0.9°C and ±0.7°C\u003cbr\u003eE: ±0.9°C and ±0.7°C\u003cbr\u003eT:  ±1.0°C and ±0.8°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1 to 125Hz and 126 to 62.5kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 to 125Hz \/ 1Hz 126 to 62.5kHz \/ 604 readings \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.04Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelection\u003c\/td\u003e\n\u003ctd\u003e604 frequencies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral characteristics\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e5 position LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating conditions\u003c\/td\u003e\n\u003ctd\u003e0 ... 50 °C \/ 32 ... 122 °F \u0026lt;85% r.h.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage conditions\u003c\/td\u003e\n\u003ctd\u003e-20 ... 60 °C \/ -4 ... 140 °F; \u0026lt;85% r.h.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e1 9V battery or 6 x 1.5V batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsumption\u003c\/td\u003e\n\u003ctd\u003e60mA to 180mA (depending on output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery indicator\u003c\/td\u003e\n\u003ctd\u003e5.5V for 150mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e88 x 168 x 26mm \/ 3.4 x 6.6 x 1 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e330 g \/ 11.6 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eDelivery Contents:\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e1 x PCE-123 Process calibrator\u003cbr\u003e1 x Carrying case\u003cbr\u003e1 x Type-k adaptor\u003cbr\u003e6 x Batteries\u003cbr\u003e1 x Test cables with alligator clips\u003cbr\u003e1 x User's manual\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding ISO Calibration","offer_id":48427058233573,"sku":"PCE-123","price":1690.0,"currency_code":"NZD","in_stock":true},{"title":"Including ISO Calibration","offer_id":48427058266341,"sku":"PCE-123-ICA","price":2070.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-current-calibrator-pce-123-ica-incl.-iso-calibration-certificate-5889847_1263092.webp?v=1788142742"},{"product_id":"torque-meter-pce-fb-10ts","title":"Digital Torque Sensor PCE-FB 2TS","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003eThe torque gauge serves for detection of the loosening torque as well as for tightening of screws. Simultaneously the torque gauge can be used as a monitoring instrument. The torque test instrument provides a keyed chuck with two steady handles.\u003cbr\u003eThe torque gauge enables taking of the tools with a maximum diameter of 13 mm and thus offers a wide range of applications. It has two adjustable thresholds which can monitor the rotation of the screws and can warn the user acoustically when the limits are reached. Thus the torque gauge can also be used without display visual contact. The display shows at a glance the breakaway or tightening as well as the current force profile. The sampling rate can be individually set up to 1000 Hz. The measurement data can be transferred during or after the measurement to the supplied torque gauge downloadable PC software or can remain in the device stored on the micro SD card. The test instrument is powered by AA mignon replaceable battery packs and thus enables a flexible use.\u003cbr\u003eIf you have any further questions about the torque gauge, you are welcome to check the following technical specifications or to use the contact form, or to call PCE. Our technicians and engineers will be glad to give any kind of assistance concerning the “Torque Test Instrument” or any other product from the section control systems, laboratory technology, measuring instruments or weighing equipment of the PCE Instruments.\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e- max. 0,5 % accuracy from the measuring range\u003cbr\u003e- Measuring rate freely adjustable up to 1000 Hz\u003cbr\u003e- 24 Bit Processor\u003cbr\u003e- keyed chuck up to Ø 13 mm\u003cbr\u003e- MIN \/ MAX Dynamic Display (PEAK\u003cbr\u003e- setpoint input with audible warning\u003cbr\u003e- statistical analysis on the device\u003cbr\u003e- Units: Nm \/ N-cm \/ kgf-m \/ gf-m \/ lbf-in\u003cbr\u003e- multilingual: DE, GB, ES, IT\u003cbr\u003e- incl. downloadable PC Software evaluation software\u003cbr\u003e- USB and RS-232 interface\u003cbr\u003e- Overload protection max. 50%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCE-FB 10TS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e10 Nm (1 kgf-m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0,01 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement uncertainty\u003c\/td\u003e\n\u003ctd\u003e±0,5 % from the measuring range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring units\u003c\/td\u003e\n\u003ctd\u003eNm, Ncm, kgfm, lbfin, gfm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emax. overload\u003c\/td\u003e\n\u003ctd\u003e50 % of the measuring range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTool intake\u003c\/td\u003e\n\u003ctd\u003ewith sprocket \/ keyed chuck up to Ø 13 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuting rate\u003c\/td\u003e\n\u003ctd\u003eFreely adjustable up to 1.000 values \/ sec.\u003cbr\u003e24 Bit Processor (16.000.000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring functions\u003c\/td\u003e\n\u003ctd\u003ePEAK Function (MIN - MAX Hold) \/ limit measurement \/ real-time measurement with Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD graphic Display 61 x 34 mm \/ automatic screen orientation \/ backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMenu guide\u003c\/td\u003e\n\u003ctd\u003eMultilingual: German \/ English \/ Spanish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory option\u003c\/td\u003e\n\u003ctd\u003eInternal memory and Mini SD memory card (the internal memory is limited to a measuring range of up to 6.400 measurements)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003emanual – by pressing a button\u003cbr\u003eautomatic - (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eSerial RS-232, 9-pin and USB\u003cbr\u003eOPTIONAL: switching contact output\u003cbr\u003eMIN \/ MAX \/ OK (see below) + 1 input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware\u003c\/td\u003e\n\u003ctd\u003eincl. downloadable PC Software for evaluation and control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient conditions\u003c\/td\u003e\n\u003ctd\u003e- 10 ... +40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e4x Ni-MH 2700 mAh AA batteries (replaceable) or via AC adapter ~230 V\/12 V; 1,2 A incl.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eauto OFF function\u003c\/td\u003e\n\u003ctd\u003eadjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003eApprox. 20 Std. (without lighting approx. 45 Std.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions evaluator\u003c\/td\u003e\n\u003ctd\u003e210 x 110 x 40 mm \/ 600 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions torque sensor\u003c\/td\u003e\n\u003ctd\u003eØ 50 x 185 mm \/ 860 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable length to the torque sensor\u003c\/td\u003e\n\u003ctd\u003eapprox. 2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e\u003cstrong\u003eDelivery Contents\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e1 x Torque gauge PCE-FB 10TS, 1 x external torque sensor, 1 x RS-232 data cable, 1 x SD Memory Card incl. Reader, 4 x AA batteries, 1 x AC adapter 1 x Carrying Case\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"PCE-FB 2TS (2Nm)","offer_id":48427058299109,"sku":"PCE-FB 10TS-1","price":5050.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-FB 5TS (5Nm)","offer_id":48427058331877,"sku":"PCE-FB 10TS-2","price":5050.0,"currency_code":"NZD","in_stock":true},{"title":"PCE-FB 10TS (10Nm)","offer_id":48427058364645,"sku":"PCE-FB 10TS-3","price":5050.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-torque-meter-pce-fb-10ts-2760889_910313.webp?v=1788142741"},{"product_id":"current-clamp-pce-360","title":"AC\/DC Clamp Meter PCE-360","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cp align=\"center\"\u003e\u003cspan\u003ePCE-360 Single-Phase \/ 1-Phase Power Meter\u003cbr\u003ePower-analyzing clamp meter with data logger functionality \/ Includes clamps, clips, leads, PC software and data cable\u003c\/span\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003eThe PCE-360 is a Single-Phase Power Meter or clamp meter with data logger functionality. This versatile power analyzer can take single-phase and three-phase power measurements both in real time and over an extended time period. The PCE-360 is used for the analysis of voltage (V), current (A), active power (kW), apparent power (kVA), reactive power (kVar), power factor (cos Φ), phase angle (Φ), frequency (Hz), rotary field (UL \u0026gt; 50V), active energy (MWh), apparent energy (MVAh), reactive energy (MVArh), harmonics (1 ... 63 order, via software), and waveforms (via software).\u003c\/p\u003e\n\u003cp align=\"justify\"\u003eThe meter's large and easy-to-read screen displays up to 10 measurements simultaneously. In manual mode, the device stores up to 99 measurements directly. In data logger mode, the device stores up to 10,000,000 sets of measurements to the 4 GB internal memory. Measured values are transferred easily to a PC using the included Windows-compatible software and data cable. In addition, four current clamps, four alligator clips, and four measuring leads are included in the delivery contents.\u003c\/p\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cp align=\"justify\"\u003e- For measurement in real time and over an extended time period up to \u003cspan\u003e578 days @ 5 second sample rate\u003c\/span\u003e\u003cbr\u003e- Includes clamps, clips, leads, PC software and data cable\u003cbr\u003e- Large, easy-to-read screen displays up to 10 measurements simultaneously\u003cbr\u003e- Stores up to 99 measurements directly in manual mode or up to 10,000,000 sets of measurements to the 4 GB internal memory in data logger mode\u003cbr\u003e- For analysis of voltage (V), current (A), active power (kW), apparent power (kVA), reactive power (kVar), power factor (cos Φ), phase angle (Φ), frequency (Hz), rotary field (UL \u0026gt; 50V), active energy (MWh), apparent energy (MVAh), reactive energy (MVArh), harmonics (1 ... 63 order, via software) and waveforms (via software)\u003cbr\u003e- Battery-saving automatic shutdown after approximately 30 minutes of inactivity\u003cbr\u003e- Device comes factory calibrated - optional ISO calibration certificate available for an additional fee (see accessories for details)\u003c\/p\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable border=\"0\" bgcolor=\"#fff\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eAC voltage AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e+10 V ... +999.9 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(0.3 % v.Mw. ±10 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eAlternating current AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e+3 A ... +999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(0.5% v.Mw. ±10 digits) at \u0026gt;10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eEffective power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.15 kW ... +999.9 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±1 % v.Mw. ±20 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003ePower factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasurement range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-1 ... +1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±10 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003ePhase angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-180 ° ... +180 °\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 °\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±15 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e+40 Hz ... +60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±0.1 % v.Mw. ±2 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eHarmonic measurement (harmonics)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasurement range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e+1 (ordinal number) ... +63 (ordinal number)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eCurrent range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e10 ... 999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eVoltage range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e10 ... 999.9 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eGeneral technical data\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage medium\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eSD card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage capacity\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e4 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage capacity additional information\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e(99 storage locations with 350,000 data records each)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMenu language\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eEnglish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eProtection class (device)\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePower supply\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e12V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePlug type\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eEuro plug device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e730 g \/ 1.61 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e235 x 117 x 54 mm \/ 9.25 x 4.61 x 2.13\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating conditions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0 ... 40 °C , 85 % r.h.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage conditions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0 ... 40 °C , 85 % r.h.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eProtection class \/ standards\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIP 30 \/ IEC 61 010, 600 V \/ CAT III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eLanguages of the instructions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eGerman, English\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cp align=\"justify\"\u003e1 x PCE-360 Current Clamp\u003cbr\u003e4 x Current clamps\u003cbr\u003e4 x Measuring leads\u003cbr\u003e4 x Alligator clips\u003cbr\u003e8 x 1.5 V AA batteries\u003cbr\u003e1 x Power adapter\u003cbr\u003e1 x USB cable\u003cbr\u003e1 x PC software CD-ROM\u003cbr\u003e1 x User manual\u003cbr\u003e1 x Carrying case\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding ISO Calibration","offer_id":48427058430181,"sku":"PCE-360","price":4640.0,"currency_code":"NZD","in_stock":true},{"title":"Including ISO Calibration","offer_id":48427058462949,"sku":"PCE-360-ICA","price":5420.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-current-clamp-pce-360-ica-incl.-iso-calibration-certificate-5892132_1279909.webp?v=1788142740"},{"product_id":"current-clamp-pce-pa-8000","title":"Power Analyzer Clamp Meter PCE-PA 8000","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cp align=\"center\"\u003e\u003cstrong\u003ePCE-PA 8000 Current Clamp\u003cbr\u003ereal time measurement with registration in the SD card \/ Integrated timer and calendar to record data \/ Active, apparent, and reactive power\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003eThe PCE-PA 8000 Current Clamp is able to measure and record the power in both single-phase or three-phase circuits. With the PCE-PA 8000 Current Clamp you will be able to perform prolonged measurements. Measurement values are saved in xls format on the included SD card of our Current Clamp to be easily analyzed on the computer. Measurement sample rate can be set from 2 to 7200 seconds. The PCE-PA 8000 Current Clamp can also measure power and determine both power factor and phase angle. The clamps of the PCE-PA 8000 Current Clamp can be used for cables with a diameter of 50 mm \/ 2.0 in. The PCE-PA 8000 is the ideal tool to be used in power supply networks. Its 3.7 in \/ 94 mm display allows you to read all measured values for a quick analysis as well as providing a view of the current, voltage, and power.\u003c\/p\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cp align=\"justify\"\u003e- Analysis of a network of 3 phases \/ 4 conductors, 3 phases \/ 3 conductors, 1 phase \/ 2 conductors, 1 phase \/ 3 conductors\u003cbr\u003e- Measures effective real value of current and voltage\u003cbr\u003e- Measures active, apparent, and reactive power\u003cbr\u003e- Power Factor (PF), phase angle (Φ)\u003cbr\u003e- Measures voltage up to 600 V\u003cbr\u003e- Measures current up to 1200 A\u003cbr\u003e- It meets the IEC 1010 and CAT III 600 V standards\u003cbr\u003e- Integrated timer and calendar to record data\u003cbr\u003e- Measured values are recorded in the included SD card\u003cbr\u003e- Data is stored in Excel format for further study\u003cbr\u003e- Data can be transferred to a PC through data cable\u003cbr\u003e- Large 3.7 in \/ 94 mm LCD display\u003c\/p\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eVoltage (AC V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 V ... 600 V (phase to neutral)\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e±(0.5 % + 0.5 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 V ... 600 V (phase to neutral)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eCurrent (AC A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003ctd\u003e0.001 A (\u0026lt; 10 A)\u003cbr\u003e0.01 A (≥ 10 A)\u003c\/td\u003e\n\u003ctd\u003e±(0.5 % + 0.1 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200 A\u003c\/td\u003e\n\u003ctd\u003e0.01 A (\u0026lt; 100 A)\u003cbr\u003e0.1 A (≥ 100 A)\u003c\/td\u003e\n\u003ctd\u003e±(0.5 % + 0.5 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1200 A\u003c\/td\u003e\n\u003ctd\u003e0.1 A (\u0026lt; 1000 A)\u003cbr\u003e1 A (≥ 1000 A)\u003c\/td\u003e\n\u003ctd\u003e±(0.5 A + 5 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eActive power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 KW ... 9.999 KW\u003c\/td\u003e\n\u003ctd\u003e0.001 KW\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 0.008 KW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 KW ... 99.99 KW\u003c\/td\u003e\n\u003ctd\u003e0.01 KW\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 0.008 KW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 KW ... 999.9 KW\u003c\/td\u003e\n\u003ctd\u003e0.1 KW\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 0.8 KW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 MW ... 9.999 MW\u003c\/td\u003e\n\u003ctd\u003e0.001 MW\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 0.008 MW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eApparent power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 KVA ... 9.999 KVA\u003c\/td\u003e\n\u003ctd\u003e0.001 KVA\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 0.008 KVA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 KVA ... 99.99 KVA\u003c\/td\u003e\n\u003ctd\u003e0.01 KVA\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 0.08 KVA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 KVA ... 999.9 KVA\u003c\/td\u003e\n\u003ctd\u003e0.1 KVA\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 0.8 KVA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 MVA ... 9.999 MVA\u003c\/td\u003e\n\u003ctd\u003e0.001 MVA\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 0.008 MVA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eReactive power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 KVAR ... 9.999 KVAR\u003c\/td\u003e\n\u003ctd\u003e0.001 KVAR\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 0.008 KVAR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 KVAR ... 99.99 KVAR\u003c\/td\u003e\n\u003ctd\u003e0.01 KVAR\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 0.08 KVAR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 KVAR ... 999.9 KVAR\u003c\/td\u003e\n\u003ctd\u003e0.1 KVAR\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 0.8 KVAR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 MVAR ... 9.999 MVAR\u003c\/td\u003e\n\u003ctd\u003e0.001 MVAR\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 0.008 MVAR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eActive energy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 KWh ... 9.999 KWh\u003c\/td\u003e\n\u003ctd\u003e0.001 KWh\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 0.008 KWh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 KWh ... 99.99 KWh\u003c\/td\u003e\n\u003ctd\u003e0.01 KWh\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 0.08 KWh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 KWh ... 999.9 KWh\u003c\/td\u003e\n\u003ctd\u003e0.1 KWh\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 0.8 KWh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 MWh... 9.999 MWh\u003c\/td\u003e\n\u003ctd\u003e0.001 MWh\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 0.008 MWh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eApparent energy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 KVAh ... 9.999 KVAh\u003c\/td\u003e\n\u003ctd\u003e0.001 KVAh\u003c\/td\u003e\n\u003ctd\u003e±(2 % + 0.008 KVAh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 KVAh ... 99.99 KVAh\u003c\/td\u003e\n\u003ctd\u003e0.01 KVAh\u003c\/td\u003e\n\u003ctd\u003e±(2 % + 0.08 KVAh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 KVAh ... 999.9 KVAh\u003c\/td\u003e\n\u003ctd\u003e0.1 KVAh\u003c\/td\u003e\n\u003ctd\u003e±(2 % + 0.8 KVAh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 MVAh... 9.999 MVAh\u003c\/td\u003e\n\u003ctd\u003e0.001 MVAh\u003c\/td\u003e\n\u003ctd\u003e±(2 % + 0.008 MVAh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eReactive energy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 KVARh ... 9.999 KVARh\u003c\/td\u003e\n\u003ctd\u003e0.001 KVARh\u003c\/td\u003e\n\u003ctd\u003e±(2 % + 0.008 KVARh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 KVARh ... 99.99 KVARh\u003c\/td\u003e\n\u003ctd\u003e0.01 KVARh\u003c\/td\u003e\n\u003ctd\u003e±(2 % + 0.08 KVARh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 KVARh ... 999.9 KVARh\u003c\/td\u003e\n\u003ctd\u003e0.1 KVARh\u003c\/td\u003e\n\u003ctd\u003e±(2 % + 0.8 KVARh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 MVARh... 9.999 MVARh\u003c\/td\u003e\n\u003ctd\u003e0.001 MVARh\u003c\/td\u003e\n\u003ctd\u003e±(2 % + 0.008 MVARh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003ePower factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 ... 1\u003c\/td\u003e\n\u003ctd\u003e0.01\u003c\/td\u003e\n\u003ctd\u003e±0.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003ePhase angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-180º ... 180º\u003c\/td\u003e\n\u003ctd\u003e0.1º\u003c\/td\u003e\n\u003ctd\u003e±1º\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e45 Hz ... 65 Hz\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eGeneral specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3.7 in \/ 94.0 mm LCD (320 x 240 pixels) with LED backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical properties\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAC V, AC A, active power, apparent power, power factor, phase angle, mains frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage ranges\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10 V ... 600 V AC, automatic range selection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity \/ Standards\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC1010CAT III 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC V input resistance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation frequency of current clamps\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e40 Hz ... 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTested operation frequency of current clamps\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e45 Hz ... 65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd\u003eAC V \/ 720 V rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC A\u003c\/td\u003e\n\u003ctd\u003e1300 A with current clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eSD card up to 16 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement display rate\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData logger\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement sample rate\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 seconds... 7200 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData output\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUSB or RS-232, depending on the connection cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0º C ... 50º C \/ 32° F ... 122° F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt; 80 % H.r.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8 x 1.5 V AA batteries \/ mains component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMeter: 300 mA DC\u003cbr\u003eClamp: 34 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. diameter\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50 mm \/ 1.9 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMeter: 948 g \/ 33.4 oz (with batteries)\u003cbr\u003eClip: 467 g \/ 16.4 oz (with cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDimensions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMeter: 225 mm x 125 mm x 64 mm \/ 8.8 in x 4.9 in x 2.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eClamp: 210 mm x 64 mm x 33 mm \/ 8.2 in x 2.5 in x 1.2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eJaw: 86 mm \/ 3.3 in (exterior)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cp align=\"justify\"\u003e1 x PCE-PA 8000 Current Clamp\u003cbr\u003e3 x Current clamps\u003cbr\u003e4 x Test cables\u003cbr\u003e4 x Alligator clips\u003cbr\u003e1 x 2 GB SD card\u003cbr\u003e1 x 9 V DC mains component\u003cbr\u003e8 x Batteries 1.5 V AA\u003cbr\u003e1 x Carrying case\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding ISO Calibration","offer_id":48427058495717,"sku":"PCE-PA 8000","price":4510.0,"currency_code":"NZD","in_stock":true},{"title":"Including ISO Calibration","offer_id":48427058528485,"sku":"PCE-PA 8000-ICA","price":5630.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-current-clamp-pce-pa-8000-ica-incl.-iso-calibration-certificate-6019677_2772699.webp?v=1788142738"},{"product_id":"voltmeter-pce-cti-10","title":"AC\/DC Voltage Tester PCE-CTI 10","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eClamp meter with Bluetooth 4.0 interface \/ Measuring range 0 ... 1500 V AC\/DC \/\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eExpandable with additional flexible current clamp for measurements up to 3000 A AC \/\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eInrush current measurement \/ VFD function \/ Incl. ISO calibration certificate\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv align=\"justify\"\u003eThe clamp meter is the ideal measuring device for measuring voltages up to 1500 V AC\/DC and currents up to 1000 A AC\/DC. The current measurement with the clamp meter is inductive. To do this, the supply line is placed in the clamp meter. This has the particular advantage that the current can be measured during operation. This means that the clamp meter is used, for example, for maintenance work on a photovoltaic system. Photovoltaic systems consist of many different solar cells that are connected in series with one another. Here, the current clamps can be used to measure the individual currents of individual rows in order to limit possible errors.\u003cbr\u003e\u003cbr\u003eIn addition to normal voltage and current measurements, the clamp meter can also measure the inrush current. Inrush currents are currents that are particularly high when the device is switched on. These currents arise when motors start up for ventilation systems, for example, or when stadium lighting is switched on. This measurement with the clamp meter is particularly important for dimensioning the supply line and fuses. Frequency converters are converters that output the voltage on the primary side with a changed frequency and amplitude on the secondary side. With the clamp meter and the VFD measurement function, measurements can be carried out up to a frequency of 45 Hz ... 1 kHz.\u003cbr\u003e\u003cbr\u003eThe clamp meter also has a Bluetooth 4.0 interface. With this interface on the clamp meter, a connection to an Android and iOS device can be established. With the free “Meterbox Pro” app, the values ​​measured by the clamp meter can be displayed and saved for later analysis.\u003cbr\u003e\u003cbr\u003eWith the data logging function, the clamp meter can save all measured values ​​at any set interval. After a measurement, the values ​​can be graphically displayed using the clamp meter. Each individual measuring point can also be read individually from the clamp meter. The storage capacity of the clamp meter has a size of 16 groups and a total storage capacity of 100,000 measured values. With the clamp meter, the measured value is saved with the date and time.\u003cbr\u003e\u003cbr\u003eThe clamp meter can be expanded with an optional current clamp. The additional current clamp to the clamp meter is flexible and can therefore be adapted to the measuring task. With the extended clamp-on ammeter, current measurements of up to 3000 A AC can be carried out. The flexible current clamp is connected to the voltage input of the clamp meter. The current clamp converts the voltage value into a usable current value and shows it on the display.\u003cbr\u003e\u003cbr\u003eBecause of its many different functions and the high measuring range, the clamp meter is used, for example, for checking photovoltaic systems, hydroelectric power plants, wind power plants or for installing immovable electrical machines. The clamp meter is equipped with an ISO calibration certificate.\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Free app for Android and iOS\u003cbr\u003e- Measuring range 0 ... 1500 V AC\/DC\u003cbr\u003e- Data logging for up to 100,000 measured values\u003cbr\u003e- Inrush current measurement\u003cbr\u003e- Additionally with LowZ voltage measurement\u003cbr\u003e- 2.36\" TFT display\u003cbr\u003e- With voltage and temperature measurement\u003cbr\u003e- Incl. calibration certificate\u003cbr\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eDC voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±600.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(0.8 % of measured value + 8 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±6.000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(0.5 % of measured value + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±60.00 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(0.5 % of measured value + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e± 600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(0.8 % of measured value + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(0.8 % of measured value + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eInput impedance: \u0026gt;10 MΩ; Overvoltage protection: 1500 VDC \/ 1000 VAC rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eAC voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.000 ... 6.000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e50 ... 60 Hz: ±(1.2 % of measured value + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e61 ... 1 kHz: ±(2.5 % of measured value + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.00 ... 60.00 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e50 ... 60 Hz: ±(1.2 % of measured value + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e61 ... 1 kHz: ±(2.5 % of measured value + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.0 ... 600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e50 ... 60 Hz: ±(1.2 % of measured value + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e61 ... 1 kHz: ±(2.5 % of measured value + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0 ... 1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e50 ... 60 Hz: ±(1.2 % of measured value + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e61 ... 1 kHz: ±(2.5 % of measured value + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eThe accuracy relates to 10 ... 100% of the respective measuring range\u003cbr\u003eand a sine wave input impedance: \u0026gt;9 MΩ;\u003cbr\u003eOvervoltage protection: 1000 V DC\/AC RMS\u003cbr\u003eThe accuracy of the \"PEAK\" function is: ±10 % of measured value\u003cbr\u003eThe response time of the \"PEAK\" function is: 1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e\u003cstrong\u003eAC voltage with low input impedance (LowZ)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.000 ... 6.000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(3.0 % of measured value + 40 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.00 ... 60.00 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(3.0 % of measured value + 40 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.0 ... 300.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(3.0 % of measured value + 40 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eInput impedance: 300 kΩ; Overvoltage protection: 1000 VDC \/ VAC RMS\u003cbr\u003eThe accuracy relates to 10 ... 100% of the respective measuring range and a sine wave\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e\u003cstrong\u003eDC and AC voltage (50 ... 1 kHz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.000 ... 6.000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(2.5 % of measured value + 40 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.00 ... 60.00 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(2.5 % of measured value + 40 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.0 ... 600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(2.5 % of measured value + 40 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0 ... 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(2.5 % of measured value + 40 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eInput impedance: 300 kΩ; Overvoltage protection: 1000 VDC \/ VAC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e\u003cstrong\u003eDC and AC voltage with low input impedance (LowZ)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.000 ... 6.000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(3.5 % of measured value + 40 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.00 ... 60.00 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(3.5 % of measured value + 40 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.0 ... 300.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(3.5 % of measured value + 40 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eInput impedance: 300 kΩ; Overvoltage protection: 1000 VDC \/ VAC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e\u003cstrong\u003eNon-Contacting Voltage Verification (NCV)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDetection range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e100 ... 1000 AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eDirect current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±60.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(3.0 % of measured value + 8 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±600.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(3.0 % of measured value + 8 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(3.0 % of measured value + 8 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOverload protection: 1000 A AC\/DC\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eAlternating current (50 ... 60 Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.00 ... 60.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(2.5 % of measured value + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.0 ... 600.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(2.5 % of measured value + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0 ... 1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(2.5 % of measured value + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eOverload protection: 1000 A AC\/DC\u003cbr\u003eThe accuracy relates to 10 ... 100 %\u003cbr\u003eof the respective measuring range and a sine wave\u003cbr\u003eThe inrush current measurement is for reference only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e\u003cstrong\u003eAC current measurement with flexible clamp meter (50 ... 400 Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.00 ... 30.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(3.0 % of measured value + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.0 ... 300.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(3.0 % of measured value + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0 ... 3000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(3.0 % of measured value + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eOverload protection: 1000 A AC\/DC\u003cbr\u003eThe accuracy relates to 10 ... 100% of the respective measuring range and a sine wave\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e\u003cstrong\u003eResistance and continuity measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.0 ... 600.0 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(1.0 % of measured value + 10 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.000 ... 6.000 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.001 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(0.8 % of measured value + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.00 ... 60.00 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(0.8 % of measured value + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.0 ... 600.0 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(0.8 % of measured value + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.000 ... 6.000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.001 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(0.8 % of measured value + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.00 ... 60.00 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(2.5 % of measured value + 10 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eContinuity test acoustic signal at: \u0026lt;50 Ω\u003cbr\u003eOvervoltage protection: 1000 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eFrequency measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.00 ... 60.00 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(0.2 % of measured value + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.0 ... 600.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(0.2 % of measured value + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.000 ... 6.000 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.001 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(0.2 % of measured value + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.00 ... 60.00 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(0.2 % of measured value + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.0 ... 600.0 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(0.2 % of measured value + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.000 ... 6.000 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.001 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(0.2 % of measured value + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eOvervoltage protection: 1000 V AC\/DC\u003cbr\u003eSensitivity:\u003cbr\u003e\u0026gt;2 Vrms with a duty cycle between 20 ... 80 % and a frequency of \u0026lt;100 kHz\u003cbr\u003e\u0026gt;5 Vrms with a duty cycle between 20 ... 80 % and a frequency of \u0026gt;100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e10.0 ... 90.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(1.2 % of measured value + 8 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eFrequency range: 40 ... 10 kHz; Pulse amplitude\u003cbr\u003e±5 V with a duration between 100 µs ... 100 mS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.00 ... 60.00 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(3.0 % of measured value + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.0 ... 600.0 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(3.0 % of measured value + 8 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.000 ... 6.000 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.001 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(3.0 % of measured value + 8 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.00 ... 60.00 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(3.0 % of measured value + 8 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.0 ... 600.0 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(3.0 % of measured value + 8 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0 ... 6000 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(3.5 % of measured value + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.00 ... 60.00 mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003efor reference only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.0 ... 600.0 mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003efor reference only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eOvervoltage protection: 1000 A AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e\u003cstrong\u003eTemperature measurement thermocouple Type K (connection)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-40.0 ... 600.0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(1.5 % of measured value + 3 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e600 ... 1000 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(1.5 % of measured value + 3 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-40.0 ... 600.0 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(1.5 % of measured value + 5.4 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e600 ... 1800 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(1.5 % of measured value + 5.4 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e245.0 ... 600.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(1.5 % of measured value + 3 K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e600 ... 1273 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(1.5 % of measured value + 3 K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eOvervoltage protection: 1000 A AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eDiode test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eTest current\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u0026lt;1.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMaximum voltage\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e3.3 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eFurther specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage space\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e16 groups with a total storage space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eof 100,000 measured values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eClamp diameter horizontal\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e38 mm \/ 1.49\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eClamp diameter vertical\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e63 mm \/ 2.48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eClamp opening\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e45 mm \/ 1.77\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eProtection class\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eInterface\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eBluetooth 4.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePollution degree\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eInsulation categories\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eCAT IV 600 V, CAT III 1000 V, CAT II 1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMaximum working height\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e2000 m \/ 6562 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePower supply battery\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e7.4 V, 1200 mAh Li-ion battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePower supply charger     \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003ePrimary: 100 ... 240 V AC, 50 ... 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eSecondary: 12 V DC, 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePlug connection charger\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eEuropa, USA, England, China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eBattery status display\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eavailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAutomatic switch-off\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eswitched off, 15, 30 or 60 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDisplay\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e2.36\" TFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDisplay frequency\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e3 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eReference conditions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e18 ... 28 °C, 64 ... 82 °F; \u0026lt;80 % RH,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003enon-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e275 x 100 x 45 mm \/ 10.8 x 3.9 x 1.7\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e481 g \/ 16.9 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Clamp meter PCE-CTI 10-ICA\u003cbr\u003e1 x Thermocouple Type-K with adapter\u003cbr\u003e1 x Pair of measuring leads\u003cbr\u003e1 x Carrying case\u003cbr\u003e1 x Battery charging station\u003cbr\u003e1 x Rechargeable battery\u003cbr\u003e1 x Instruction manual\u003cbr\u003e1 x ISO Calibration Certificate\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding ISO Calibration","offer_id":48427058626789,"sku":"PCE-CTI 10","price":1190.0,"currency_code":"NZD","in_stock":true},{"title":"Including ISO Calibration","offer_id":48427058659557,"sku":"PCE-CTI 10-ICA","price":1370.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-voltmeter-pce-cti-10-ica-incl.-iso-calibration-certificate-5988152_1851913_37cf4380-f07c-40fd-8559-2f977c078526.webp?v=1788142736"},{"product_id":"voltmeter-pce-itm-20","title":"Digital Voltage \u0026 Current Tester PCE-ITM 20","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e\u003cstrong\u003eVoltmeter PCE-ITM 20\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eThe isolation multimeter is a combined multimeter and insulation tester \/ \u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eTest voltage up to 1000 V \/ Large LCD display \/ Temperature measurement \/ Frequency measurement \/ Internal memory \/ CAT IV 600 V \/ IP67 \/ Wireless USB\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eThis voltmeter combines a versatile multimeter with an insulation tester. In addition to the usual measured quantities such as voltage, current and resistance, this voltmeter is also equipped with a frequency and capacitance measurement. A thermocouple included in the delivery can also be used to measure the temperature. Automatic range selection (Autorange) allows fast and safe operation with the voltmeter, while the large backlit LCD display ensures good readability. \u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eThe highlight of this voltmeter is the integrated insulation tester. With test voltages of up to 1000 V, insulation resistances of up to 5000 MΩ (5 GΩ) are measured. Likewise, the voltmeter can directly measure the PI and DAR value. Thus, it is quickly possible to make a statement about the insulation value of the DUT with the help of the voltmeter. \u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eIn addition, this voltmeter has an internal memory. This gives you the opportunity to recall the stored measured values for subsequent analysis in the display and to transfer the measured values via the wireless USB interface from the voltmeter to a PC.\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Automatic range selection\u003cbr\u003e- Capacitance measurement\u003cbr\u003e- Integrated isolation tester\u003cbr\u003e- Large LCD display, backlight\u003cbr\u003e- Internal memory\u003cbr\u003e- Hold Function\u003cbr\u003e- To IEC 1010, CAT III 1000V, CAT IV 600V\u003cbr\u003e- Frequency measurement \u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"180\"\u003e\u003cstrong\u003eTest voltage \/ test current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"125\"\u003e\u003cstrong\u003eMeasuring range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"92\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"131\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e50V 1-mA @ 50 kΩ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 ... 5 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.0001 MΩ\u003c\/td\u003e\n\u003ctd\u003e± (4 % + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e5 ... 50 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.001 MΩ\u003c\/td\u003e\n\u003ctd\u003e± (4 % + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e50 ... 500 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ\u003c\/td\u003e\n\u003ctd\u003e± (4 % + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e500 ... 1000 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.1 MΩ\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e125V \/ 1-mA @ 125 kΩ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 ... 5 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.001 MΩ\u003c\/td\u003e\n\u003ctd\u003e± (2 % + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e5 .... 50 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.001 MΩ\u003c\/td\u003e\n\u003ctd\u003e± (2 % + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e50 ... 500 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ\u003c\/td\u003e\n\u003ctd\u003e± (3 % + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e500 .... 5000 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.1 MΩ\u003c\/td\u003e\n\u003ctd\u003e± (4 % + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e250V \/ 1-mA @ 250 kΩ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 ... 5 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.0001 MΩ\u003c\/td\u003e\n\u003ctd\u003e± (2 % + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e5 ... 50 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.001 MΩ\u003c\/td\u003e\n\u003ctd\u003e± (2 % + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e50 ... 500 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ\u003c\/td\u003e\n\u003ctd\u003e± (3 % + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e500 ... 5000 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.1 MΩ\u003c\/td\u003e\n\u003ctd\u003e± (4 % + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e500V \/ 1-mA @ 500 kΩ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 ... 5 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.0001 MΩ\u003c\/td\u003e\n\u003ctd\u003e± (2 % + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e5 ... 50 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.001 MΩ\u003c\/td\u003e\n\u003ctd\u003e± (2 % + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e50 ... 500 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ\u003c\/td\u003e\n\u003ctd\u003e± (3 % + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e500 ... 5000 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.1 MΩ\u003c\/td\u003e\n\u003ctd\u003e± (4 % + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1000V \/ 1-mA @ 1000 kΩ\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 ... 5 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.0001 MΩ\u003c\/td\u003e\n\u003ctd\u003e± (2 % + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e5 ... 50 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.001 MΩ\u003c\/td\u003e\n\u003ctd\u003e± (2 % + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e50 ... 500 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ\u003c\/td\u003e\n\u003ctd\u003e± (3 % + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e500 ... 5000 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.1 MΩ\u003c\/td\u003e\n\u003ctd\u003e± (4 % + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort circuit current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1.5-mA\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMultimeter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring parameters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mV\u003c\/td\u003e\n\u003ctd\u003e0.001 mV\u003c\/td\u003e\n\u003ctd\u003e± (0.06 %+ 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 mV\u003c\/td\u003e\n\u003ctd\u003e0.01 mV\u003c\/td\u003e\n\u003ctd\u003e± (0.06 %+ 6 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e5 V\u003c\/td\u003e\n\u003ctd\u003e0.0001 V\u003c\/td\u003e\n\u003ctd\u003e± (0.06 %+ 4 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003c\/td\u003e\n\u003ctd\u003e± (0.06 %+ 4 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e0.01 V\u003c\/td\u003e\n\u003ctd\u003e± (0.06 %+ 4 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e± (0.1 %+ 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mV\u003c\/td\u003e\n\u003ctd\u003e0.001 mV\u003c\/td\u003e\n\u003ctd\u003e± (1 % + 50 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC + DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 mV\u003c\/td\u003e\n\u003ctd\u003e0.01 mV\u003c\/td\u003e\n\u003ctd\u003e± (1 % + 50 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e50 .... 1000 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 V\u003c\/td\u003e\n\u003ctd\u003e0.0001 V\u003c\/td\u003e\n\u003ctd\u003e± (1 % + 30 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003c\/td\u003e\n\u003ctd\u003e± (1 % + 30 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e0.01 V\u003c\/td\u003e\n\u003ctd\u003e± (1 % + 30 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e± (1 % + 30 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\n\u003cdiv align=\"justify\"\u003e\u003cstrong\u003eThe specified accuracy for alternating voltage refers to 5 ... 100% of the measuring range\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDirect current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e500 µA\u003c\/td\u003e\n\u003ctd\u003e0.01 µA\u003c\/td\u003e\n\u003ctd\u003e± (0.5 % + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e5000 µA\u003c\/td\u003e\n\u003ctd\u003e0.1 µA\u003c\/td\u003e\n\u003ctd\u003e± (0.5 % + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003ctd\u003e0.001 mA\u003c\/td\u003e\n\u003ctd\u003e± (0.5 % + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e500 mA\u003c\/td\u003e\n\u003ctd\u003e0.01 A\u003c\/td\u003e\n\u003ctd\u003e± (0.5 % + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003ctd\u003e0.001 A\u003c\/td\u003e\n\u003ctd\u003e± (0.5 % + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlternating current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 µA\u003c\/td\u003e\n\u003ctd\u003e0.01 µA\u003c\/td\u003e\n\u003ctd\u003e± (1% + 30 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC + DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 µA\u003c\/td\u003e\n\u003ctd\u003e0.1 µA\u003c\/td\u003e\n\u003ctd\u003e± (1% + 30 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e50 .... 1000 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003ctd\u003e0.001 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e± (1% + 30 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e500 mA\u003c\/td\u003e\n\u003ctd\u003e0.01 A\u003c\/td\u003e\n\u003ctd\u003e± (1% + 30 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003ctd\u003e0.001 A\u003c\/td\u003e\n\u003ctd\u003e± (1% + 30 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\n\u003cdiv align=\"justify\"\u003e\u003cstrong\u003eThe specified accuracy for alternating current refers to 5 ... 100% of the measuring range\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e50 Ω\u003c\/td\u003e\n\u003ctd\u003e0.01 Ω\u003c\/td\u003e\n\u003ctd\u003e± (0.2 % + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e500 Ω\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003ctd\u003e± (0.1 % + 10 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e5 kΩ\u003c\/td\u003e\n\u003ctd\u003e0.0001 kΩ\u003c\/td\u003e\n\u003ctd\u003e± (0.1 % + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e50 kΩ\u003c\/td\u003e\n\u003ctd\u003e0.001 kΩ\u003c\/td\u003e\n\u003ctd\u003e± (0.1 % + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e500 kΩ\u003c\/td\u003e\n\u003ctd\u003e0.01 kΩ\u003c\/td\u003e\n\u003ctd\u003e± (0.1 % + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e5 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.001 MΩ\u003c\/td\u003e\n\u003ctd\u003e± (1 % + 10 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e50M Ω\u003c\/td\u003e\n\u003ctd\u003e0.001 MΩ\u003c\/td\u003e\n\u003ctd\u003e± (1.5 % + 50 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 nF\u003c\/td\u003e\n\u003ctd\u003e0.001 nF\u003c\/td\u003e\n\u003ctd\u003e± (1.5 % + 50 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e50 nF\u003c\/td\u003e\n\u003ctd\u003e0.01nF\u003c\/td\u003e\n\u003ctd\u003e± (1.5 % + 10 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e500 nF\u003c\/td\u003e\n\u003ctd\u003e0.1 nF\u003c\/td\u003e\n\u003ctd\u003e± (1.5 % + 10 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e5 µF\u003c\/td\u003e\n\u003ctd\u003e0.001µF\u003c\/td\u003e\n\u003ctd\u003e± (1.5 % + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e50 µF\u003c\/td\u003e\n\u003ctd\u003e0.01µF\u003c\/td\u003e\n\u003ctd\u003e± (1.5 % + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e500 µF\u003c\/td\u003e\n\u003ctd\u003e0.1µF\u003c\/td\u003e\n\u003ctd\u003e± (1.5 % + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e5 mF\u003c\/td\u003e\n\u003ctd\u003e0.001 mF\u003c\/td\u003e\n\u003ctd\u003e± (3 % + 30 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e10 mF\u003c\/td\u003e\n\u003ctd\u003e0.01 mF\u003c\/td\u003e\n\u003ctd\u003e± (3 % + 30 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003ctd\u003e0.001 Hz\u003c\/td\u003e\n\u003ctd\u003e± (0.02 % + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e(Electronics)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 Hz\u003c\/td\u003e\n\u003ctd\u003e0.01 Hz\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e± (0.02 % + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e5 kHz\u003c\/td\u003e\n\u003ctd\u003e0.0001 kHz\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e± (0.02 % + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e50 kHz\u003c\/td\u003e\n\u003ctd\u003e0.001 kHz\u003c\/td\u003e\n\u003ctd\u003e± (0.02 % + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e500 kHz\u003c\/td\u003e\n\u003ctd\u003e0.01 kHz\u003c\/td\u003e\n\u003ctd\u003e± (0.02 % + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e5 MHz\u003c\/td\u003e\n\u003ctd\u003e0.0001 MHz\u003c\/td\u003e\n\u003ctd\u003e± (0.02 % + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e50 MHz\u003c\/td\u003e\n\u003ctd\u003e0.001 MHz\u003c\/td\u003e\n\u003ctd\u003e± (0.02 % + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e100 MHz\u003c\/td\u003e\n\u003ctd\u003e0.01 MHz\u003c\/td\u003e\n\u003ctd\u003enot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\n\u003cdiv align=\"justify\"\u003e\u003cstrong\u003eSensitivity: 0.8 VRMS min @ 20% ... 80% duty cycle \u0026lt;100 kHz 5 V RMS min @ 20% ... 80%\u0026gt; 100 kHz\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency (Electronics)\u003c\/td\u003e\n\u003ctd\u003e40 Hz ... 10 kHz\u003c\/td\u003e\n\u003ctd\u003e0.01 1 Hz ... 0.001 kHz\u003c\/td\u003e\n\u003ctd\u003e± (0.1%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty Cycle\u003c\/td\u003e\n\u003ctd\u003e0.1 ... 99.9%\u003c\/td\u003e\n\u003ctd\u003e0.01%\u003c\/td\u003e\n\u003ctd\u003e± (1.2% + 2 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse width\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e100 µS ... 100 ms; Frequency: 5 Hz ... 150 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature -\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e58 ... 2462°F\u003c\/td\u003e\n\u003ctd\u003e0.1°F\u003c\/td\u003e\n\u003ctd\u003e± (0.5 % + 7°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType K Thermoelement\u003c\/td\u003e\n\u003ctd\u003e-50 ... 13350 °C\u003c\/td\u003e\n\u003ctd\u003e0.1°C\u003c\/td\u003e\n\u003ctd\u003e± (0.5 % + 3.5°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4 ... 20 mA%\u003c\/td\u003e\n\u003ctd\u003e-25 ... 125%\u003c\/td\u003e\n\u003ctd\u003e0.01%\u003c\/td\u003e\n\u003ctd\u003e± 50 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance 50 Ω range\u003c\/td\u003e\n\u003ctd\u003e50 Ω\u003c\/td\u003e\n\u003ctd\u003e0.001 Ω\u003c\/td\u003e\n\u003ctd\u003e± (1 % + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e500 Ω\u003c\/td\u003e\n\u003ctd\u003e0.01 Ω\u003c\/td\u003e\n\u003ctd\u003e± (1 % + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003eOpen circuit voltage: 5V; Overload protection 250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eMemory\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e9999 memory points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eHousing\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDouble moulded housing, IP67 (waterproof and dustproof)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eDrop test\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 m \/ 6ft, 6in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eDiode test\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTest current 0.9-mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOpen circuit voltage 2.8-mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eContinuity test\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAcoustic signal at resistance \u0026lt; 35 Ω \/ Test current \u0026lt; 0.35-mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003ePeak detection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 1ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTemperature sensor\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eThermoelement Type K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eInput impedance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDC: \u0026gt; 10 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAC: \u0026gt; 9 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAC coupling\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTRMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eBandwidth AC voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50 Hz ... 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eCrest factor\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt;3 at 500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt; 1.5 at 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50000 digit LCD illuminated with bargraph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAutomatic shutdown\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eafter 15 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eMeasurement rate \/ update display\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003ePower supply\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6 x 1.5V AA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eInterface\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWireless USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eFuses\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003emA,µA: 0.5 A \/ 1000V fast ceramic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eA: 10 A \/ 1000V fast ceramic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eOperating conditions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5 ... 40°C \/ 41 ... 104°F, max 80% r.H.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eStorage conditions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20 ... 60°C \/ -4 ... 140°F, max. 80% r.H.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMax. 2000 m \/ 6561 feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eWeight\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eca. 720 g \/ 1.6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eDimensions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e220 x 95 x 50 mm \/ 8.6 x 3.7 x 1.9 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eSafety standards\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEN61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61010-1 Part 2 (2001)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCAT IV 600V, CAT III 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUL 61010-1 Part 2 (2004)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCAN\/CSA C22.2 No 6110-1 Part 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e(2004)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUL 61010B-2-031 Part 1 (2003)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Voltmeter PCE-ITM 20\u003cbr\u003e1 x Pair of test leads\u003cbr\u003e1 x Crocodile clip with wire\u003cbr\u003e1 x Adapter for thermoelement\u003cbr\u003e1 x Thermoelement Type K\u003cbr\u003e6 x 1.5V AA batteries\u003cbr\u003e1 x Wireless USB Adapter\u003cbr\u003e1 x User manual\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":48427058725093,"sku":"PCE-ITM 20","price":1220.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-voltmeter-pce-itm-20-6019720_2095105_23a43649-df59-4d5e-9cae-bd231e986844.webp?v=1788142734"},{"product_id":"voltmeter-pce-gpa-50","title":"Power Analyzer PCE-GPA 50","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003cstrong\u003eVoltmeter\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e PCE-GPA 50\u003cbr\u003eCurrent clamp up to 2000 A \/ TRMS measurement \/ Power measurement \/ Harmonic analysis \/ Graphic display with lighting \/ Data storage \/ Mains and battery operation\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv\u003eThe PCE-GPA 50 current clamp is used to measure the current of 1- or 3-phase loads. This clamp is especially characterized by its measuring range up to 2000 A. Another highlight is the graphic display of the current clamp. Here, in addition to the numerical measured values, the waveform of the phase can also be displayed by the current clamp. Likewise, the current clamp can be used to measure voltages. As a result, the current clamp is able to calculate effective, apparent and reactive power with the help of the phase angle. In addition, the current clamp can measure other network parameters such as the energy, power factor and harmonic.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eIn addition to the extensive measuring functions, this current clamp distinguishes your data logger function. All measured values ​​can be stored by the current probe directly on a micro SD card. The clamp is powered by 2 1.5V AA batteries. However, it is also possible to operate the current clamp with a power supply for long-term measurements.\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Graphic display\u003cbr\u003e- Data logger on Micro-SD card\u003cbr\u003e- Measurement for 1 and 3 phases\u003cbr\u003e- Temperature measurement with thermocouple\u003cbr\u003e- Voltage measurement 10V ... 600V AC RMS\u003cbr\u003e- Current measurement 5 ... 2000 A AC RMS\u003cbr\u003e- Current clamp opening 50 mm\u003cbr\u003e- Harmonic distortion up to the 50th order\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv class=\"tab-pane fade in  active\" id=\"tab-customdata3\"\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable border=\"0\" bgcolor=\"#FFFFFF\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"0\" valign=\"top\"\u003e\u003cstrong\u003e\u003cspan\u003eType of measurement\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"0\" colspan=\"3\" valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003e\u003cspan\u003eAC voltage AC V    \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e\u003cspan\u003eMeasuring range      \u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e10 ... 600V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0.1V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± (0.5% ... 3 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003ePeak to peak\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0.1V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± (5% ... 30 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp align=\"justify\"\u003e\u003cstrong\u003e\u003cspan\u003eAC AC A\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e5 ... 2000 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e\u0026lt; 100 A: 0.01 A    \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e\u0026lt; 200 A: ± (1% + 0.5 A)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e\u0026lt; 1000 A: 0.1 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e\u0026gt; 200 A: ± (1% + 5 A)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003ePeak to peak\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e\u0026gt; 1000 A: 1 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± (5% + 30 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e\u003cspan\u003ePower factor (PF)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0 ... 1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0.001\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± 0.04\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e\u003cspan\u003ePhase angle\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e-180° ... 180°\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0.1°\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± 1° x PF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e\u003cspan\u003eFrequency\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e45 ... 65 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0.1 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± 0.2 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e\u003cspan\u003eActive, blind \u0026amp;\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0 ... 9,999 m\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0.1 ... 0.001 M\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± (1.5% + 20 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e\u003cspan\u003eapparent power\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e(W \/ VA \/ VAR)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e(W \/ VA \/ VAR)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e\u003cspan\u003eHarmonic AC V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e1 ... 20th order\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0.1V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± (2% + 5 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cspan\u003e21 ... 50 order\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0.1V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± (4% + 5 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cstrong\u003e\u003cspan\u003eHarmonic AC A\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e1 ... 20th order\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e\u0026lt; 100 A: 0.01 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± (2% + 5 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e\u003cspan\u003eAlternating current\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e\u0026lt; 1000 A: 0.1 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e21 ... 50 order\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e\u0026gt; 1000 A: 1 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± (4% + 5 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e\u003cspan\u003eHarmonic AC V%\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e1 ... 20th order\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0.1%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± (2% + 10 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e21 ... 50 order\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0.1%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± (4% + 20 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e\u003cspan\u003eAbsolute harmonic\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0 ... 20%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0.1%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± (2% + 5 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e\u003cspan\u003edistortion\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e20.1 ... 100%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0.1%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± (6% + 10 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e\u003cspan\u003eTemperature type K\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cspan\u003e-100 ... 199.9°C \/ -148 ... 391.8\u003c\/span\u003e°F \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cspan\u003e0.1°C \/ 0.18\u003c\/span\u003e°F    \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± (1% + 1°C \/ 1.8°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e\u003cspan\u003ethermocouple\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cspan\u003e200 ... 1300°C \/ 392 ... 2372\u003c\/span\u003e°F \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cspan\u003e1°C \/ 1.8\u003c\/span\u003e°F\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± (1% + 2°C \/ 3.6°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"top\"\u003e\u003cspan\u003eGraphic LCD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eAC V input impedance        \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"top\"\u003e\u003cspan\u003e10 MOhm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eFrequency range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"top\"\u003e\u003cspan\u003e40 Hz ... 1 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eCurrent Probe\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eCalibrated frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"top\"\u003e\u003cspan\u003e45 ... 65 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eCurrent Probe\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eOverload protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"top\"\u003e\u003cspan\u003eAC V: 720V RMS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"top\"\u003e\u003cspan\u003eAC A: 2100 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eData storage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"top\"\u003e\u003cspan\u003eMicro SD card\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eRefresh rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"top\"\u003e\u003cspan\u003e1 second\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eStorage rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"top\"\u003e\u003cspan\u003e2 ... 7200s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eData storage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eStorage format\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"top\"\u003e\u003cspan\u003eXLS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eInterface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"top\"\u003e\u003cspan\u003eSerial interface for live presentation to PC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"top\"\u003e\u003cspan\u003e(SOFT-LUT-USB is required)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003ePower supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"top\"\u003e\u003cspan\u003e2 x 1.5V AA battery\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"top\"\u003e\u003cspan\u003e9V \/ 800-mA power supply\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eCurrent consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"top\"\u003e\u003cspan\u003e60-mA DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eJaw Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"top\"\u003e\u003cspan\u003e50 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eOperating conditions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"top\"\u003e\u003cspan\u003e0 ... 50°C \/ 32 ... 122°F, max. 80% rh\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"top\"\u003e\u003cspan\u003eAbout 595 g \/ 1.3 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"top\"\u003e\u003cspan\u003e280 x 106 x 47 mm \/ 11 x 4.2 x 1.9 in \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x V\u003cspan\u003eoltmeter\u003c\/span\u003e PCE-GPA 50\u003cbr\u003e1 x Test lead set\u003cbr\u003e2 x Crocodile clips\u003cbr\u003e1 x Micro SD memory card\u003cbr\u003e1 x Power supply 9V \/ 800-mA\u003cbr\u003e2 x 1.5V AA battery\u003cbr\u003e1 x Carrying bag\u003cbr\u003e1 x User manual\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding ISO Calibration","offer_id":48427058856165,"sku":"PCE-GPA 50","price":2220.0,"currency_code":"NZD","in_stock":true},{"title":"Including ISO Calibration","offer_id":48427058888933,"sku":"PCE-GPA 50-ICA","price":2750.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-voltmeter-pce-gpa-50-ica-incl.-iso-calibration-certificate-5952220_1567473.webp?v=1788142732"},{"product_id":"voltmeter-pce-mcm-10","title":"Multifunction Voltage Meter PCE-MCM 10","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e\u003cspan\u003eVoltmeter with 1 m (3.3 ft) cable \/ measurement range ±99.9 mA DC \/ manual zero point \/\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003ebattery life of approx. 40 hours \/ automatic power off \/ clamp opening Ø 5 mm \/\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e  accuracy of ±0.3% of rdg.\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eThe voltmeter has a measurement range of ±99.9 mA DC. With an accuracy of 0.3% of rdg. +8 digits, the voltmeter is a particularly accurate measuring instrument. In order to conveniently perform measurements with the voltmeter, the current clamp itself is connected to a 1 meter \/ 3.3 ft cable. The current clamp can thus be attached to the cable to be measured. The voltmeter can be conveniently placed aside at the workplace. This leaves both hands free while reading the measured values, for example to carry out adjustments or configurations on the process technology. Due to the high accuracy and the external sensor, the voltmeter is ideally suited to make quick and reliable current measurements when process signals are involved.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eIn order to carry out a current measurement, the current clamp of the voltmeter must be clamped around the cable to be checked. This allows the voltmeter to measure the flowing current inductively. This has the particular advantage that a current measurement can be carried out during operation with the voltmeter.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eFor improved visibility, the voltmeter is equipped with an LED. With the LED of the voltmeter, the measuring spot can be ideally illuminated. \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eIf you have any further questions about the PCE-MCM 10 voltmeter, please take a look at the following technical data or use our contact form. Our technicians and engineers will be happy to advise you on the voltmeter or any other products in the fields of control, laboratory or measuring technology or scales and balances from PCE Instruments.\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e- Detachable process clamp meter with 1 m \/ 3.3 ft cable\u003c\/div\u003e\n\u003cdiv\u003e- Clamp opening of 5 mm diameter\u003c\/div\u003e\n\u003cdiv\u003e- Measurement range ±99.9 mA DC\u003c\/div\u003e\n\u003cdiv\u003e- Display with backlight \u003c\/div\u003e\n\u003cdiv\u003e- Operating time of approx. 40 hours \u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable border=\"0\" bgcolor=\"#FFFFFF\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e±20.99 mA DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(0.3 % of rdg. + 8 Digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e±21.0 … ±99.9 mA DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(1 % of rdg. + 8 Digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003eInfluence of the earth's magnetic field on the measured value, max. 0.25 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDiameter of clamp opening     \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eØ5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eSwitch-off\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eautomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eContinuously switched on\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eafter 10 minutes OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating voltage\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e3V via 2 AA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eBattery life\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eapprox. 40 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eProtection class\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOvervoltage categories\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eCAT II 300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating conditions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-10 … 50°C \/ 14 ... 122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage conditions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-15 … 60°C \/ 5 ... 140°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eEnvironmental humidity\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u0026lt;90% RH at \u0026lt; 30°C \/ 86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u0026lt;75% RH at 30 ... 50°C \/ 86 ... 122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWorking altitude\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0 ... 2000 m \/ 6,561 ft above sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003ehandheld device: 180 x 55 x 39 mm \/ 7.1 x 2.2 x 1.5 in \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003ecurrent clamp: 90 x 40 x 1.5 mm \/ 3.5 x 1.6 x 0.06 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003ecable length: approx. 1 m \/ 3.3 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e268 g \/ 0.6 lbs with batteries inserted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e1 x Voltmeter PCE-MCM 10-ICA\u003c\/div\u003e\n\u003cdiv\u003e2 x 3V via 2 AA batteries\u003c\/div\u003e\n\u003cdiv\u003e1 x Instruction manual\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding ISO Calibration","offer_id":48427058921701,"sku":"PCE-MCM 10","price":980.0,"currency_code":"NZD","in_stock":true},{"title":"Including ISO Calibration","offer_id":48427058954469,"sku":"PCE-MCM 10-ICA","price":1390.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-voltmeter-pce-mcm-10-ica-incl.-iso-calibration-certificate-6107873_2657833.webp?v=1788142730"},{"product_id":"voltmeter-pce-dc-25","title":"Digital DC Voltmeter PCE-DC 25","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eVoltmeter with Bluetooth interface \/ Current measurement 0 ... 1000 A AC\/DC \/ Temperature measurement \/ NCV test \/ Clamp opening 34 mm (1.3\") \/ Measuring rate of 3 Hz \/\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eOptionally expandable with Rogowski coil for 3000 A AC \/ Automatic switch-off\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv align=\"justify\"\u003eThe voltmeter has a measuring range of 0… 1000 A AC\/DC. The current is measured inductively using the clamp on the measuring device. Live supply lines with a diameter of up to 32 mm (1.2\") can be connected to the clamp meter. With the optional Rogowski coil, the measuring range of the clamp meter can be extended to up to 3000 A AC. The clamp meter has sub-functions for current measurement. The inrush current can be measured with the clamp meter. This is a particularly important function, as motors such as those installed in ventilation systems or hall lighting require a particularly high current when switched on.\u003cbr\u003e\u003cbr\u003eIn addition to current measurement, the voltmeter can also measure voltages from 0… 1000 V AC\/DC, resistances, frequencies and capacitances. The functions can be set using the rotary selector switch on the clamp meter. With the NCV function, the clamp meter can be used to determine the absence of voltage without contact. As soon as a voltage of 150 V AC is applied, this is indicated by an additional red LED. This function is active for every measuring function selected using the rotary selector switch. An LED lamp is integrated in the clamp meter for optimal illumination of the measuring point.\u003cbr\u003e\u003cbr\u003eThe voltmeter can be connected to an Android or iOS device via the Bluetooth interface. With the free app for the clamp meter, the measured values ​​can be displayed, saved and further processed. The clamp meter thus covers a wide range of measuring tasks due to the multitude of functions.\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Measuring range 0 ... 1000 A AC\/DC\u003cbr\u003e- Bluetooth interface\u003cbr\u003e- Inrush current measurement\u003cbr\u003e- Not Connected Voltage function\u003cbr\u003e- LC colour display\u003cbr\u003e- Optionally with ISO certificate\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eDC voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e600.0 mV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 mV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(0.5 % + 8 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e6.000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.001 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(1.5 % + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e60.00 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(1.5 % + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e600.0 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(1.5 % + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(1.5 % + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eInput impedance\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u0026gt;10 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOvervoltage protection\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1000 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eAC voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e6.000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.001 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(1.5 % + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e60.00 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(1.5 % + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e600.0 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(1.5 % + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(1.5 % + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePeak value (PEAK) accuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePeak value (PEAK) response time\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eInput impedance\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u0026gt;10 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOvervoltage protection\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1000 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eThe accuracy relates to a measuring range of 10 ... 100 %\u003cbr\u003ewith a sine wave.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eLow pass filter (LowZ)\u003cbr\u003e(50 ... 400 Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e6.000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.001 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(3.0 % + 40 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e60.00 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(3.0 % + 40 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e300.0 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(3.0 % + 40 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eInput impedance\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u0026lt;300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOvervoltage protection\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1000 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eThe accuracy relates to a measuring range of 10 ... 100 %\u003cbr\u003ewith a sine wave.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eAC with DC voltage\u003cbr\u003e(50 ... 400 Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e6.000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.001 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(2.5 % + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e60.00 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(2.5 % + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e600.0 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(2.5 % + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(2.5 % + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eInput impedance\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u0026gt;10 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eDirect current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e600.0 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(2.5 % + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1000 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(2.8 % + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOvervoltage protection\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1000 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eAlternating current\u003cbr\u003e(50 ... 60 Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e600.0 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(2.5 % + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1000 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(2.8 % + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOverload protection\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1000 A AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eFlexible clamp meter\u003cbr\u003e(50 ... 400 Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e30.00 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(3.0 % + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e300.0 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(3.0 % + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e3000 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(3.0 % + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOverload protection\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e3000 A AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eThe accuracy relates to a measuring range of 10 ... 100 %\u003cbr\u003ewith a sine wave.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eResistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e600.0 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(1.0 % + 10 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e6.000 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.001 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(1.5 % + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e60.00 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(1.5 % + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e600.0 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(1.5 % + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e6.000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.001 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(2.5 % + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e60.00 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(3.5 % + 10 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOvervoltage protection\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1000 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eContinuity test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eSignal\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u0026lt;50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOvervoltage protection\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1000 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eDiode test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eTest current\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u0026lt;1.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMaximum tension when open\u003cbr\u003ecircuit\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e3.3 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eFrequency measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e9.999 Hz ... 99.99 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 ... 10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(1.2 % + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOvervoltage protection\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1000 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u0026gt;5 Vrms with one duty cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e from 20 ... 80 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eDuty cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e10.0 ... 90.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(1.2 % + 8 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePulse range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e40 Hz ... 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePulse amplitude\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±5 V (0.1 ... 100 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e60.00 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(4.0 % + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e600.0 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(3.0 % + 8 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e6.000 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.001 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(3.0 % + 8 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e60.00 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(3.0 % + 8 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e600.0 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(3.0 % + 8 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e6000 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(5.0 % + 8 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e60.00 mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.01 mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(5.0 % + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e100.0 mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(5.0 % + 20 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOvervoltage protection\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1000 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eTemperature measurement\u003cbr\u003e(Thermocouple Type K)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-40 ... 600.0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(1.5 % + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e600 ... 1000 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(1.5 % + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-40 ... 600.0 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0.1 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(1.5 % + 9 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e600 ... 1800 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e±(1.5 % + 9 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOvervoltage protection\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1000 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003eThe accuracy refers to the measuring device without temperature probe.\u003cbr\u003eSpecifications refer to a stable ambient condition of ±1 °C.\u003cbr\u003eIf the measurement lasts for a long time, the measured value increases by 2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eFurther specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eClamp opening\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e34 mm \/ 1.3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eNCV\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u0026gt;150 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDisplay\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eLC colour display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDisplay when measuring range exceeded  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\"OL\" (overload)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring rate\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e3 measured values per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eInterface\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eBluetooth\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating conditions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e5 ... 40 °C \/ 41 ... 104 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u0026lt;80 % RH non-condensing at\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e31 °C \/ 87 °F linearly decreasing to 50 % RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003enon-condensing at 40 °C \/ 104 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage conditions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-20 ... 40 °C \/ -4 ... 140 °F \u0026lt;80 % RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMaximum working height\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e2000 m \/ 7000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePower supply\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e3 x 1.5 V AAA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAuto power off\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eSwitched off, 15, 30, 45, 60 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e250 x 80 x 40 mm \/ 9.8 x 3.1 x 1.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e365 g \/ 12.8 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Voltmeter PCE-DC 25\u003cbr\u003e1 x Pair of test leads\u003cbr\u003e1 x Type K thermocouple\u003cbr\u003e1 x Thermocouple adapter\u003cbr\u003e3 x 1.5 V AAA batteries\u003cbr\u003e1 x Transport bag\u003cbr\u003e1 x Instruction manual\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":48427060658405,"sku":"PCE-DC 25","price":720.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-voltmeter-pce-dc-50-ica-incl.-iso-calibration-certificate-6023696_2154815.webp?v=1788142727"},{"product_id":"electric-vehicle-evse-tester-pce-evse-kit2","title":"EV Charging Station Test Kit PCE-EVSE-KIT2","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eRobust Insulation Tester\/ Electrical resistance \/ Earthing resistance \/ Loop impedance \/ Voltage measurement \/ Low resistance measurement \/ RCD test\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv align=\"justify\"\u003eThis is a robust installation tester with a large 3.5\" TFT colour LCD display. The installation tester also offers, in addition to the various measuring modes such as insulation resistance, grounding resistance, loop impedance, voltage, low-impedance measurement and RCD test with the camera function, the possibility of documenting suitable photos with the measurements. With the installation tester, you can ensure that fixed installations are safely and correctly installed. Thanks to the dual display, the intuitive symbols and the high viewing angle, you can comfortably and quickly perform your measurements with the installation tester. With the low-resistance measurement of the installation tester, you can check grounding conductors, potential equalization rails and protective conductors for low impedance.\u003cbr\u003e\u003cbr\u003eThe measuring range for low-resistance measurement with the installation tester is in the range of 0 - 2000 Ω with a resolution of 0.001 - 1 Ω. Probably the most important measurement of the installation tester is the measurement of insulation resistance. Electrical cables are placed under voltage during the insulation measurement in order to detect fault currents, which generate material migration or heat. In most cases, these current faults are so minimal that they are not detected by protective devices and in the worst case they can lead to a fire. The installation tester can carry out installation measurement with a test voltage of 125V, 250V, 500V or 1000V.\u003cbr\u003e\u003cbr\u003eThe load current is in each case 1 mA. The installation tester is independent of the mains supply. In order to bring all systems and circuits of a power supply system to a common potential (ground reference or potential reference) and to protect against short-circuit currents and overvoltages, the earthing resistor should be as low-impedance as possible. With a measuring range of 0 ... 2000 Ω with a resolution of 0.01 ... 1 Ω, the installation tester DT-6650 offers all the prerequisites for a meaningful measurement of the grounding resistance.\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eEVSE adapter for charging plugs type 1 and 2 \/ PP and CP simulation \/\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eSchuko socket connection \/ Direct acceptance of all connections via laboratory plugs\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv align=\"justify\"\u003eElectromobility is playing an increasingly important role. An important point here are the charging stations for electric vehicles. Special measuring devices are needed to check the function, protective devices and insulation of permanently installed charging stations, also known as wallboxes. Often, measuring devices are already available to perform the required measurements. An adapter is therefore required so that the measuring device can be connected to the charging station.\u003cbr\u003e\u003cbr\u003eThe EVSE adapter is specially designed for this application and already comes with a variety of functions. For example, all lines leaving the charging station are output individually via laboratory plugs. Thus, all lines can be tapped via the EVSE adapter. This allows the charging station to be checked for insulation with the help of the EVSE adapter. The EVSE adapter has a shock-proof plug connection. The RCD tester can be used to check the residual current device.\u003cbr\u003e\u003cbr\u003eA charging cable not only contains the supply lines for charging an electric vehicle, but also two interfaces. The electric vehicle communicates with the charging station via the CP line (Control Pilot) and communicates the current status of the electric vehicle. The PP line (Proximity Plug) is used for communication between the connected charging cable and the charging station. The charging cable can thus tell the charging station how many amps it may be loaded with. To test both functions, the EVSE adapter is equipped with corresponding simulators.\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- 3.5\" colour TFT LCD display\u003cbr\u003e- Loop resistance L-N, L-PE and N-PE\u003cbr\u003e- Adjustable FI test current\u003cbr\u003e- SD card and bluetooth\u003cbr\u003e- Dual display\u003cbr\u003e- Good \/ bad FI test\u003cbr\u003e- Low Ohm measurement\u003cbr\u003e- Up to 1000 V terminal voltage\u003cbr\u003e- Transport bag included in delivery\u003cbr\u003e- Direct connection for wallboxes\u003cbr\u003e- Adapter with type 1 and type 2 charging plugs\u003cbr\u003e- PE conductor test\u003cbr\u003e- Integrated Schuko socket\u003cbr\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eInstallation Tester PCE-ITE 50\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\"\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation test\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"27%\"\u003e\n\u003cp\u003eTerminal voltage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"15%\"\u003e\n\u003cp\u003eMeasuring range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"10%\"\u003e\n\u003cp\u003eResolution\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003eAccuracy\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003eLoad current\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003eShort circuit current\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" width=\"27%\"\u003e\n\u003cp\u003e125V (0 ... 10 %)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"15%\"\u003e\n\u003cp\u003e0,125 ... 4 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"10%\"\u003e\n\u003cp\u003e0.001 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e± (2% + 10 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e1-mA @ Last 125 kΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e\u0026lt;= 1-mA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"15%\"\u003e\n\u003cp\u003e4,001 ... 40 MΩ \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"10%\"\u003e\n\u003cp\u003e0.01 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e± (2% + 10 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"15%\"\u003e\n\u003cp\u003e40,01 ... 400 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"10%\"\u003e\n\u003cp\u003e0.1 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e± (4% + 5 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"15%\"\u003e\n\u003cp\u003e400,1 ... 1000 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"10%\"\u003e\n\u003cp\u003e1 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e± (5% + 5 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" width=\"27%\"\u003e\n\u003cp\u003e250V (0 ... 10 %)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"15%\"\u003e\n\u003cp\u003e0,125 ... 4 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"10%\"\u003e\n\u003cp\u003e0.001 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e± (2% + 10 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e1-mA @ Last 250 kΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e\u0026lt;= 1-mA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"15%\"\u003e\n\u003cp\u003e4,001 ... 40 MΩ \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"10%\"\u003e\n\u003cp\u003e0.01 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e± (2% + 10 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"15%\"\u003e\n\u003cp\u003e40,01 ... 400 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"10%\"\u003e\n\u003cp\u003e0.1 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e± (3% + 2 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"15%\"\u003e\n\u003cp\u003e400,1 ... 1000 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"10%\"\u003e\n\u003cp\u003e1 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e± (3% + 2 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" width=\"27%\"\u003e\n\u003cp\u003e500V (0 ... 10 %)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"15%\"\u003e\n\u003cp\u003e0,125 ... 4 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"10%\"\u003e\n\u003cp\u003e0.001 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e± (2% + 10 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e1-mA @ Last 500 kΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e\u0026lt;= 1-mA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"15%\"\u003e\n\u003cp\u003e4,001 ... 40 MΩ \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"10%\"\u003e\n\u003cp\u003e0.01 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e± (2% + 10 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"15%\"\u003e\n\u003cp\u003e40,01 ... 400 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"10%\"\u003e\n\u003cp\u003e0.1 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e± (3% + 2 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"15%\"\u003e\n\u003cp\u003e400,1 ... 1000 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"10%\"\u003e\n\u003cp\u003e1 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e± (4% + 5 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" width=\"27%\"\u003e\n\u003cp\u003e1000 V (0 ... 10 %)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"15%\"\u003e\n\u003cp\u003e0,125 ... 4 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"10%\"\u003e\n\u003cp\u003e0.001 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e± (3% + 10 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e1-mA @ Last 1 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e \u0026lt;= 1-mA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"15%\"\u003e\n\u003cp\u003e4,001 ... 40 MΩ \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"10%\"\u003e\n\u003cp\u003e0.01 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e± (2% + 10 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"15%\"\u003e\n\u003cp\u003e40,01 ... 400 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"10%\"\u003e\n\u003cp\u003e0.1 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e± (3% + 2 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"15%\"\u003e\n\u003cp\u003e400,1 ... 1000 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"10%\"\u003e\n\u003cp\u003e1 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e± (4% + 5 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\"\u003e\n\u003cp\u003e\u003cstrong\u003eLow Ohm \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"27%\"\u003e\n\u003cp\u003eMeasuring range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"15%\"\u003e\n\u003cp\u003eResolution\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eAccuracy\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003eMax. open circuit voltage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003eOverload protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"27%\"\u003e\n\u003cp\u003e2,000 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"15%\"\u003e\n\u003cp\u003e0.001 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e± (1.5% + 30 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e5.8V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e250 Vrms\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"27%\"\u003e\n\u003cp\u003e20,00 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"15%\"\u003e\n\u003cp\u003e0.01 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e± (1.5% + 3 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e5.8V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e250 Vrms\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"27%\"\u003e\n\u003cp\u003e200,0 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"15%\"\u003e\n\u003cp\u003e0.1 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e± (1.5% + 3 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e5.8V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e250 Vrms\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"27%\"\u003e\n\u003cp\u003e2000 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"15%\"\u003e\n\u003cp\u003e1 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e± (1.5% + 5 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e5.8V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e250 Vrms\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\"\u003e\n\u003cp\u003e\u003cstrong\u003eContinuity tester\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"27%\"\u003e\n\u003cp\u003eMeasuring range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eResolution\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003eMax. open circuit voltage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003eOverload protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003eShort circuit current\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"27%\"\u003e\n\u003cp\u003e2000 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e0.01 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e5.8V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e250 Vrms\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"16%\"\u003e\n\u003cp\u003e\u0026gt;= 200-mA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\"\u003e\n\u003cp\u003e\u003cstrong\u003eLoop resistance\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\"\u003e\n\u003cp\u003eL-PE (Hi-Amp): Load current 4.0 A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eMeasuring range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eResolution\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eAccuracy\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e0.23 ... 9.99 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e0.01 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e± (4% + 4 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e10.0 ... 99.9 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e0.1 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e± (4% + 4 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e100 ... 999 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e1 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e± (4% + 4 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\"\u003e\n\u003cp\u003eL-PE (without tripping): Load current 15-mA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eMeasuring range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eResolution\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eAccuracy\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e0.23 ... 9.99 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e0.01 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e± (5% + 6 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e10.0 ... 99.9 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e0.1 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e± (5% + 6 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e100 ... 999 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e1 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e± (5% + 6 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\"\u003e\n\u003cp\u003eL-N: Load current 4.0 A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eMeasuring range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eResolution\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eAccuracy\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e0.23 ... 9.99 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e0.01 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e± (4% + 4 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e10.0 ... 99.9 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e0.1 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e± (4% + 4 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e100 ... 999 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e1 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e± (4% + 4 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\"\u003e\n\u003cp\u003e\u003cstrong\u003eRCD Test\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003eRCD (In)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003e10-mA, 30-mA, 100-mA, 300-mA, 650-mA, 1 A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003eFactors\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003ex 1\/2, x1, x2, x5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003eAccuracy of the tripping time\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003e± (1% + 1 ms)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003eSignal form of the test current\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003eSine (AC), pulse (DC)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003eTripping characteristics\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003eG and S\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003eRelease time\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003e0° or 180°\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003eVoltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003e194 ... 260V AC (50\/60 Hz)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003eAccuracy of current measurement\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003e± (5% + 2 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"3\"\u003eRCD Types\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"3\"\u003eType A, Type B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\"\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage measurement\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eMeasuring range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eResolution\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eAccuracy\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e80...500 V AC\/DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e1 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e± (2 % + 2 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\"\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency measurement\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eMeasuring range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eResolution\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eAccuracy\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e45...65 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e1 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e±2 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\"\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding measurement\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eMeasuring range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eResolution\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eAccuracy\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e0.00...99.99 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e0.01 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e± (2% + 30 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e100.0...999.9 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e0.1 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e± (2% + 6 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e1000...2000 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e1 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e± (2% + 6 digits)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003ePower supply\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003e8 x 1.2 ... 1.5V AA batteries\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003eOperating time\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003eca. 15 h\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003eMeasurement category\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003eCAT III 600V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003eProtection class\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003eIP 65\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003eDisplay\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003e3.5\" TFT (320 x 240 Pixel)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003eOperating environment\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003e0 ... 45°C\u003cbr\u003e0 ... 95% rH, non condensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003eMeasurements\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003e24.2 x 10.5 x 14.5 cm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003eWeight\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003e1.56 kg \/ 3.4 lbs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" valign=\"top\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"1\" valign=\"top\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" valign=\"top\"\u003e\n\u003cstrong\u003eEVSE Measuring Device PCE-EVSE-300\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" valign=\"top\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePE test (protective conductor)\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eavailable, error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePP simulation (charging cable coding)  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eopen, 13 A, 20 A, 32 A, 63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eCP simulation (communication line)\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eA, B, C, D, error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eOutputs (only for test purposes)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring connections\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eL1, L2, L3, N, PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003emax. 250 \/ 430 V AC, 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003elaboratory plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eSchuko connection\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003emax. 250 V AC, 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eFuse from the Schuko connection\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003efuse F 10 A \/ 250 V, 5 x 20 mm \/  0.19 x 0.78\"\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eCP signal output\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e± 12 V PWM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eFurther specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eInput voltage\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 phase: 250 V AC \/ 3 phase 430 V AC,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e50 \/ 60 Hz, max. 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eCharging cable connector Type 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eAC charging mode 3, compatible with IEC62196-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eType 1 or SAE J1772 with vehicle connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e(Type 1, 5 pin, 1-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eCharging cable connector Type 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eAC charging mode 3, compatible with IEC62196-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eType 1 or SAE J1772 with vehicle connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e(Type 2, 7 pin, 3-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasurement category\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eCAT II 300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eProtection class\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePollution degree\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating conditions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0 ... 40 °C \/ 32 ... 104 °F, 10 ... 85% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage conditions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-10 ... 50 °C \/ 14 ... 122 °F, 10 ... 60% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMaximum working height\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003emax. 2000 m \/ 6561 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions (handheld only)\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e277 x 109 x 63 mm \/ 10.9 x 4.3 x 2.4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eca. 1 kg \/ 2.2 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cstrong\u003eEVSE Measuring Device PCE-EVSE-KIT2\u003c\/strong\u003e\u003cbr\u003e1 x EVSE Adapter PCE-EVSE 300\u003cbr\u003e1 x Installation Tester PCE-ITE 50\u003cbr\u003e1 x Charging cable plug type 1\u003cbr\u003e1 x Charging cable plug type 2\u003cbr\u003e1 x Transport bag\u003cbr\u003e1 x Instruction manual\u003cbr\u003e1 x Test leads\u003cbr\u003e1 x Transport case\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Excluding ISO Calibration","offer_id":48427060723941,"sku":"PCE-EVSE-KIT2","price":3460.0,"currency_code":"NZD","in_stock":true},{"title":"Including ISO Calibration","offer_id":48427060756709,"sku":"PCE-EVSE-KIT2-ICA","price":4090.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-electric-vehicle-ev-tester-ev-test-pce-evse-kit2-ica-incl-iso-cal-certificate-5980875_1782619.webp?v=1788142726"},{"product_id":"electric-vehicle-evse-tester-pce-evse-310","title":"EV Charging Station Tester PCE-EVSE 310","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e\u003cstrong\u003eElectric Vehicle EVSE Tester \/ vehicle simulation \/ cable simulation \/ CP output and mains socket for measuring purposes \/ incl. transport bag\u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv\u003eThe electric vehicle EVSE tester is  for VDE 0100 testers to test charging stations (charging mode 3) for electric cars. This adapter can be used with the PCE-ITE 55B installation tester or with most other standard VDE 0100 testers. Thanks to the LEDs for voltage detection on the 3 phases, it can be quickly determined if there is an installation error. \u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eThe PP State rotary switch can be used to simulate the current carrying capacity of the charging cable. The current carrying capacity is simulated with various resistors in the electric vehicle EVSE tester, which are connected between PP and PE conductors. Various vehicle states can be simulated using the CP State rotary switch. The vehicle states are simulated with different resistors connected between the CP and PE conductors.\u003cbr\u003e\u003cbr\u003eAn external load can be connected to the socket. This output is only intended for measuring purposes and offers the option of checking the function of the electricity meter. The electric vehicle EVSE tester can also be used to simulate a PE fault (earth fault). The electric vehicle EVSE tester is supplied in a device bag. There is also an optional adapter for wallboxes with a type 1 connection. \u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e- PE pre-test\u003c\/div\u003e\n\u003cdiv\u003e- Status of the Proximity Pilot PP and the Control Pilot CP\u003c\/div\u003e\n\u003cdiv\u003e- Simulation of CP fault \"E\" and PE fault\u003c\/div\u003e\n\u003cdiv\u003e- Mains socket for measuring purposes\u003c\/div\u003e\n\u003cdiv\u003e- Safety measuring sockets\u003c\/div\u003e\n\u003cdiv\u003e- incl. adapter to type 1\u003cbr\u003e- incl. type 2 plug\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e. . . . . . . . . . . . . . . . . . . . .\n\u003ctable border=\"0\" bgcolor=\"#fff\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eTest Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePE pre-test\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eyes, with capacitive electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePP Simulation\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eopen, 13 A, 20 A, 32 A, 63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eCP Status\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eA, B, C, D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eCP error \"E\"\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePE fault \/ earth fault\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eGeneral technical data\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eConnections\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eL1, L2, L3, N, PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eConnections Additional information  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003emax. 230V (1-phase) \/ 430V (3-phase) ; 50 \/ 60Hz\u003cbr\u003e10A \/ 250 V\u003cbr\u003eType 2 plug fixed to the cable\u003cbr\u003e(optional adapter required for type 1)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStandard(s)\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIEC62196-2 Type 2 connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eCable length\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e25 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eSafety standard\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eCAT II \/ 300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePower socket\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003emax. 250 V; 50\/60 Hz; 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOutputs\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e2 x 4mm sockets (signal output terminals)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eFuse(s)\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003ePower socket T10A\/250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eProtection class (device)\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e643 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e600 x 105 x 73 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating conditions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0 ... 40 °C , 80 % r.H.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage conditions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-10 ... 50 °C , 80 % r.F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eLanguages of instructions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eGerman, English\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e1 x Electric Vehicle EVSE Tester PCE-EVSE 310+\u003c\/div\u003e\n\u003cdiv\u003e1 x operating instructions\u003c\/div\u003e\n\u003cdiv\u003e1 x transport bag\u003cbr\u003e\n\u003cdiv\u003e1 x type 2 plug\u003c\/div\u003e\n\u003cdiv\u003e1 x adapter to type 1 \u003cspan\u003e(PCE-EVSE ADP)\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":48427060953317,"sku":"PCE-EVSE 310","price":1090.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-electric-vehicle-evse-tester-pce-evse-310-6124655_2890701.webp?v=1788142724"},{"product_id":"earth-tester-earth-resistance-meter-pce-ert-10","title":"Digital Earth Resistance Tester PCE-ERT 10","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e\u003cstrong\u003eEarth Tester \/ Earth Resistance Tester PCE-ERT 10\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003emeasures earth resistance up to 2000 Ω \/ with earth voltage measurement \/ CAT III 1000 V \/ with zero positioning \/ large LCD display \/ g\u003c\/strong\u003e\u003cstrong\u003eround spikes included\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003eThis is a handy measuring instrument, which allows fast and easy determination of the earth resistance. The earth tester \/ earth resistance meter determines the earth resistance with three-wire technology in three measuring ranges up to 2000 Ω. By means of a rotary knob, a zero position can be performed before each measurement in order to achieve the optimum accuracy. Furthermore, this grounding measuring device offers a normal resistance measurement up to 200 kΩ, the measurement of the ground voltage, and a voltage measurement for DC and AC voltage.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDuring the measurement of the earth resistance, the battery voltage is displayed next to the measured value in the large LCD display with background lighting. This special function of the earth tester \/ earth resistance meter helps the measuring technician to recognize the charging status of the batteries directly from the earthing device. In addition to the earthing device and the necessary measuring cables, the earth spikes are also included in the delivery. The set is completed by a carrying case, in which all the accessories of the earthing device can be found and can therefore be taken everywhere.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e- Three-wire measuring method\u003c\/div\u003e\n\u003cdiv\u003e- Earth resistance is determined in three measuring ranges up to 2000 Ω\u003c\/div\u003e\n\u003cdiv\u003e- Ground voltage measurement up to 200 V\u003c\/div\u003e\n\u003cdiv\u003e- Zeroing possible\u003c\/div\u003e\n\u003cdiv\u003e- Alternating and DC voltage measurement\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring ranges\u003cbr\u003eEarth resistance\u003cbr\u003eEarth voltage\u003cbr\u003eDC voltage\u003cbr\u003eAlternating voltage\u003cbr\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e20 Ω \/ 200 Ω \/ 2000 Ω\u003cbr\u003e200 V\u003cbr\u003e1000 V\u003cbr\u003e750 V (40 Hz - 400 Hz)\u003cbr\u003e200 kΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003cbr\u003eEarth resistance\u003cbr\u003eEarth voltage\u003cbr\u003eDC voltage\u003cbr\u003eAlternating voltage\u003cbr\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.01 Ω \/ 0.1 Ω \/ 1 Ω\u003cbr\u003e0.1 V\u003cbr\u003e1 V\u003cbr\u003e1 V\u003cbr\u003e0.1 kΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003cbr\u003eEarth resistance\u003cbr\u003eEarth voltage\u003cbr\u003eDC voltage\u003cbr\u003eAlternating voltage\u003cbr\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e±(2 % + 10 dgt) \/ ±(2 %+3 dgt) \/ ±(2 %+3dgt)\u003cbr\u003e±(3 % + 3 dgt)\u003cbr\u003e±(0.8 % + 3 dgt)\u003cbr\u003e±(1.2 % + 10 dgt)\u003cbr\u003e±(1 % + 2 dgt)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample rate\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2.5 \/ seconds\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLCD display with background light\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e6 x 1.5 V AA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental conditions\u003c\/td\u003e\n\u003ctd\u003e0 ... +40 °C \/ \u0026lt;80 % r.H.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e200 x 92 x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e700 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIEC10101, CAT III 1000V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Earth Tester \/ Earth Resistance Meter PCE-ERT 10\u003cbr\u003e1 x set of test leads (approx. 15m)\u003cbr\u003e4 x ground spikes\u003cbr\u003e6 x batteries\u003cbr\u003e1 x carrying case\u003cbr\u003e1 x instruction manual\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":48427060986085,"sku":"PCE-ERT 10","price":730.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-earth-tester-earth-resistance-meter-pce-ert-10-5845186_1040210_54907e48-81f2-4c80-b78d-0c557d2a769b.webp?v=1788142722"},{"product_id":"earth-tester-earth-resistance-meter-pce-ect-50-uk","title":"Earth Resistance Tester PCE-ECT 50-UK","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eEarth tester \/ earth resistance meter PCE-ECT 50-UK for testing earthing resistance \/ Installation category III \/ 7 meter measuring lead at the safety measuring tip \/ High measuring accuracy \/ Protection class IP40 \/ 50, 60 Hz operating voltage\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv align=\"justify\"\u003eThe earth tester \/ earth resistance meter is a handy measuring device. Due to the robust and ergonomic design, the user can work comfortably with the earth tester. The earthing resistance can be determined quickly with the earth tester. In addition, a check can be made as to whether the earths are connected to each other. To ensure a clear reading, the earth tester has a large, clearly arranged, multicoloured LC display.\u003cbr\u003e\u003cbr\u003eThe display also gives a visual feedback about the state of the installation. If the installation is OK, the display will remain blue. In the event of a faulty installation, the display of the earth tester changes to a red background. The earth tester consists of a read-out unit, which is plugged into the socket as a whole and a safety test tip, which is connected to the reading unit via the underside. The safety probe has a cable length of about seven meters.\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Multi-coloured, backlit LCD\u003cbr\u003e- Installation category III\u003cbr\u003e- 50 \/ 60 Hz operating voltage\u003cbr\u003e- High measuring accuracy\u003cbr\u003e- Handy construction\u003cbr\u003e- IP40, IK06 protection\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"156\" valign=\"top\"\u003eMeasuring principle\u003c\/td\u003e\n\u003ctd width=\"380\" valign=\"top\"\u003eContinuity test \/ earth resistance measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0 ... 2000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDisplay\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003etwo-color, backlit LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasurement accuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e± (3 % + 3 Digits) at 0 ... 200 Ω at 23 °C ±5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating voltage\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e230 V (Ph\/N) -10 \/ +6 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating frequency\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStandards\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIEC 611010-1 EN 61557-4, Class II, IP40, IK06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eInstallation category\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-15 ... +45 °C \/ +5 ... +113 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-25 ... +70 °C \/ -13 ... +158 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e72 x 210 x 50 mm (W x L x H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eLength of test cable\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eca. 7 m \/ 22 ft 11\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e340 g \/ 12 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\u003cbr\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Earth Tester \/ Earth Resistance Meter PCE-ECT 50-UK\u003cbr\u003e1 x 7m test lead on reel\u003cbr\u003e1 x User manual\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":48427061051621,"sku":"PCE-ECT 50-UK","price":590.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-earth-tester-earth-resistance-meter-pce-ect-50-uk-5981963_1952358_1.webp?v=1788142720"},{"product_id":"cable-detector-pce-cl-20","title":"Electrical Wire \u0026 Conduit Tracer PCE-CL 20","description":"\u003cp\u003eThe \u003cstrong\u003ePCE-CL 20\u003c\/strong\u003e is a handheld cable detector designed to locate and trace cables in walls, floors, and ceilings. It is an essential tool for electricians and maintenance technicians, providing accurate cable tracing without damaging walls.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLocates live and dead cables\u003c\/li\u003e\n  \u003cli\u003eAdjustable sensitivity for precise detection\u003c\/li\u003e\n  \u003cli\u003eLED indicator for signal strength\u003c\/li\u003e\n  \u003cli\u003eCompact and portable design\u003c\/li\u003e\n  \u003cli\u003eBattery-operated for convenience\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch6\u003eSpecifications\u003c\/h6\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDetection Depth:\u003c\/strong\u003e Up to 10 cm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 2 x 9V batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery Scope:\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x PCE-CL 20 Cable Detector\u003c\/li\u003e\n  \u003cli\u003e2 x 9V Batteries\u003c\/li\u003e\n  \u003cli\u003e1 x Carrying Case\u003c\/li\u003e\n  \u003cli\u003e1 x User Manual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":48427061084389,"sku":"PCE-CL 20","price":1000.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-cable-detector-pce-cl-20-5719095_967872.webp?v=1788142719"},{"product_id":"cable-detector-pce-180-cbn","title":"Underground Cable \u0026 Metal Locator PCE-180 CBN","description":"\u003cp\u003eThe \u003cstrong\u003ePCE-180 CBN\u003c\/strong\u003e is a handheld, portable, battery-powered cable locator and wire tracer designed for detecting wires and cables hidden behind walls or insulation. It features an amplifier probe and acoustic signal or tone generator, making it ideal for locating network and coaxial cables.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAcoustic signal detection for wires and cables\u003c\/li\u003e\n  \u003cli\u003e3-position toggle switch with 3-color LED for line polarity, continuity, and voltage testing\u003c\/li\u003e\n  \u003cli\u003eIncludes red and black test leads with alligator clips\u003c\/li\u003e\n  \u003cli\u003eStandard 4-conductor modular cord and plug\u003c\/li\u003e\n  \u003cli\u003eBattery-powered with recessed on\/off button to prevent accidental activation\u003c\/li\u003e\n  \u003cli\u003eAdjustable volume and selectable tone options\u003c\/li\u003e\n  \u003cli\u003eBuilt-in headphone jack\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch6\u003eSpecifications\u003c\/h6\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDetection Method:\u003c\/strong\u003e Acoustic signal\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 2 x 9 V batteries\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Conditions:\u003c\/strong\u003e 0 ... +50 °C \/ +32 ... +122 °F and 5 ... 95% rh\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 60 x 65 x 30 mm (signal generator), 245 x 60 x 30 mm (amplifier probe)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 120 g (signal generator), 140 g (amplifier probe)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery Scope:\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x PCE-180 CBN Cable Detector (with amplifier probe, tone generator, and 2 x test leads with alligator clips)\u003c\/li\u003e\n  \u003cli\u003e2 x 9 V batteries\u003c\/li\u003e\n  \u003cli\u003e1 x Carrying Case\u003c\/li\u003e\n  \u003cli\u003e1 x User Manual\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":48427061313765,"sku":"PCE-180 CBN","price":560.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-cable-detector-pce-180-cbn-56321_829532_1f66951b-4fb6-4605-892f-bdeb10d8c236.webp?v=1788142718"}],"url":"https:\/\/inspectec.co.nz\/collections\/pce-brand.oembed?page=5","provider":"Inspectec","version":"1.0","type":"link"}