{"product_id":"decibel-meter-badge-type-pce-mnd-10","title":"Noise Dosimeter PCE-MND 10","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDescription\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eDecibel meter (badge type) according to IEC 61252:2002 \/ Measuring range 70 ... 140 dB \/ Crocodile clips \/ For use in occupational safety \/ Battery life \u0026gt;15 hours \/ USB interface \/\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003eKey lock \/ Frequency weighting A, B and Z \/ Optional with ISO calibration certificate\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv align=\"justify\"\u003eThe decibel meter (badge type) was specially developed for measuring noise exposure in workplaces and complies with the IEC 61252:2002 standard. With a measuring range of 70 … 140 dB and a frequency weighting of A, B and Z, the noise dose meter is ideal for this. The time weighting on the noise dose meter can be selected between fast, slow and impulse. With the built-in 470 mAh battery, the noise dose meter has a runtime of \u0026gt;15 hours.\u003cbr\u003e\u003cbr\u003eUp to three virtual noise dose meters can be set in a decibel meter (badge type). This has the advantage that up to three measurement standards can measure simultaneously. The display of the noise dose meter shows up to 14 measurement windows that can be set individually.\u003cbr\u003e\u003cbr\u003eThe data transfer from the decibel meter (badge type) to a PC takes place directly via the charging station. The recorded measurement data can be read out and analyzed with the software for the noise dose meter. In addition, all settings for the noise dose meter can be made via the software. Another special feature of the noise dose meter is that the charging stations can be coupled with each other. This has the advantage that several noise dose meters can be charged via one power pack. Up to four noise dose meters can be charged simultaneously per power supply.\u003cbr\u003e\u003cbr\u003eFor optimal support and positioning, the decibel meter (badge type) is attached to the work clothing of the respective employee with two crocodile clips. The distance between hearing and the noise dose meter should be between 10 and 15 cm (3.9 and 5.9\").\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHighlights\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Frequency weighting A, B and Z\u003cbr\u003e- Battery life of \u0026gt;15 hours\u003cbr\u003e- Software for setting the parameters\u003cbr\u003e- Measuring range 70 ... 140 dB\u003cbr\u003e- IEC 61252:2002, ANSI S1.25-1991\u003cbr\u003e- Optional with ISO calibration certificate\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSpecification\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eMeasuring range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e70 … 140 dB (A, C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e90 … 140 dB (Z)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range (peak value)\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e103 … 143 dB PEAK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e0.1 dB\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eclass 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eFrequency range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e31.5 Hz … 8 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eFrequency weightings\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eA, C and Z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eTime weighting\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003efast, slow, impulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAdjustable level increase\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e3, 4, 5, 6 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eThreshold adjustment range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e70 … 90 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eThreshold resolution\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAdjustment range of the criterion level\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e70 … 90 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution of the criterion level\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDisplay if the ambient condition is too loud   \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u0026gt;115 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMemory\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e30 measurement runs with total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e 6101 measuring points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eTimer\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e16 timers for an automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003edata logging and 99 timers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWarm-up time\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e10 seconds after power on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMicrophone\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1\/2 inch electret condenser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDisplay\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e128 x 64 pixel LC display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eFor applications according to the standard\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIEC 61252:2002, ANSI S1.25-1991\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eNumber of virtual dosimeters\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDosimeter standards\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eOSHA-80, OSHA-90, MSHA-80, MSHA-90, DOD,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eACGIH, ISO-85, ISO-90, NR-15, NHO-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIn addition, up to 9 individual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003estandards can be stored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasurement parameters for all\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eDOSE (Dose), PDOSE (Pdos), TWA (Twa),\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003evirtual dosimeter\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003ePTWA (PTwa), LAVG (Lavg), LEPd (Lepd),\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003ePLEPd (PLepd), Exceed time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e(Las\u0026gt;105 or Las \u0026gt;115),\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLEQ\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e(Laeq, Lceq, Lzeq), SEL (LaE, LCE or LZE),\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eSEpa2h (Ea, Ec, Ez), PEAK (Pka, Pkc or Pkz),\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eLEX8H (Lex8h), PLEX8H (PLex8h),\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eEXPHrs (Exph), EXPsec (Exps), NEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAdditional measurement parameters\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eMAX\/MIN, L05, L10, L50,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003efor the first virtual dosimeter\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eL90 and L95 at a 20 ms interval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eand a difference of 0.1 dB,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eLAEQ05, LAEQ10, LAEQ50, LAEQ90,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eLAEQ95 at a 1 s interval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eand a difference of 0.1 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eInterface\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eUSB interface on the charging station\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePower supply (battery)\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e3.7 V, 470 mAh, lithium polymer battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePower supply (mains adapter)\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eprimary: 100 ... 240 V AC, 50 ... 60 Hz, 0.7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003esecondary: 9 V DC, 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating time\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u0026gt;15 hours at 23 °C \/ 73 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating conditions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0 … 50 °C (32 … 122 °F), 10 … 95 % RH,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003enon-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage conditions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-10 … +60 °C (14 … 140 °F), 10 … 75 % RH,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003enon-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e84 x 49 x 55 mm \/ 3.3 x 1.9 x 2.2 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e77 g \/ 2.7 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDelivery Scope\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Decibel meter (badge type) PCE-MND 10\u003cbr\u003e1 x USB cable\u003cbr\u003e1 x Charging station with power adapter\u003cbr\u003e1 x Supply bridge\u003cbr\u003e1 x Mounting bridge\u003cbr\u003e1 x Carrying case\u003cbr\u003e1 x Instruction manual\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.pce-instruments.com\/english\/english\/download-win_4.htm\" title=\"Software PCE-MND 10\"\u003eSoftware download\u003c\/a\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-files\"\u003e\n\u003ch1 class=\"headline\"\u003eDownloads\u003c\/h1\u003e\n\u003cdiv class=\"pkdownloads\"\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/www.pce-instruments.com\/english\/api\/getartfile?_fnr=3357723\u0026amp;_dsp=inline\" target=\"_blank\"\u003e\u003cbr\u003e\u003cspan class=\"mimetitle mimetitlet_custom_manual mimetitlel_EN\"\u003eManual\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.pce-instruments.com\/english\/api\/getartfile?_fnr=2657469\u0026amp;_dsp=inline\" target=\"_blank\"\u003e\u003cbr\u003e\u003cspan class=\"mimetitle mimetitlet_custom_datasheet mimetitlel_EN\"\u003eDatasheet\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"PCE","offers":[{"title":"Without Calibration Certificate","offer_id":48427447451877,"sku":"Without Calibration Certificate","price":2820.0,"currency_code":"NZD","in_stock":true},{"title":"With Calibration Certificate","offer_id":48427447484645,"sku":null,"price":3140.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-decibel-meter-badge-type-pce-mnd-10-5999546_1958546.webp?v=1771409579","url":"https:\/\/inspectec.co.nz\/products\/decibel-meter-badge-type-pce-mnd-10","provider":"Inspectec","version":"1.0","type":"link"}