{"product_id":"earth-tester-earth-resistance-meter-pce-ect-50-uk","title":"Earth Resistance Tester PCE-ECT 50-UK","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDESCRIPTION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eEarth tester \/ earth resistance meter PCE-ECT 50-UK for testing earthing resistance \/ Installation category III \/ 7 meter measuring lead at the safety measuring tip \/ High measuring accuracy \/ Protection class IP40 \/ 50, 60 Hz operating voltage\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv align=\"justify\"\u003eThe earth tester \/ earth resistance meter is a handy measuring device. Due to the robust and ergonomic design, the user can work comfortably with the earth tester. The earthing resistance can be determined quickly with the earth tester. In addition, a check can be made as to whether the earths are connected to each other. To ensure a clear reading, the earth tester has a large, clearly arranged, multicoloured LC display.\u003cbr\u003e\u003cbr\u003eThe display also gives a visual feedback about the state of the installation. If the installation is OK, the display will remain blue. In the event of a faulty installation, the display of the earth tester changes to a red background. The earth tester consists of a read-out unit, which is plugged into the socket as a whole and a safety test tip, which is connected to the reading unit via the underside. The safety probe has a cable length of about seven meters.\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHIGHLIGHTS\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Multi-coloured, backlit LCD\u003cbr\u003e- Installation category III\u003cbr\u003e- 50 \/ 60 Hz operating voltage\u003cbr\u003e- High measuring accuracy\u003cbr\u003e- Handy construction\u003cbr\u003e- IP40, IK06 protection\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSPECIFICATION\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"156\" valign=\"top\"\u003eMeasuring principle\u003c\/td\u003e\n\u003ctd width=\"380\" valign=\"top\"\u003eContinuity test \/ earth resistance measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0 ... 2000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDisplay\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003etwo-color, backlit LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasurement accuracy\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e± (3 % + 3 Digits) at 0 ... 200 Ω at 23 °C ±5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating voltage\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e230 V (Ph\/N) -10 \/ +6 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating frequency\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStandards\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIEC 611010-1 EN 61557-4, Class II, IP40, IK06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eInstallation category\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-15 ... +45 °C \/ +5 ... +113 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-25 ... +70 °C \/ -13 ... +158 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e72 x 210 x 50 mm (W x L x H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eLength of test cable\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eca. 7 m \/ 22 ft 11\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e340 g \/ 12 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\u003cbr\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDELIVERY SCOPE\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Earth Tester \/ Earth Resistance Meter PCE-ECT 50-UK\u003cbr\u003e1 x 7m test lead on reel\u003cbr\u003e1 x User manual\u003c\/div\u003e\n\u003c\/div\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003ePDF Specification Sheet - \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003eDownload Here\u003c\/span\u003e\u003c\/p\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":48427061051621,"sku":"PCE-ECT 50-UK","price":600.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-earth-tester-earth-resistance-meter-pce-ect-50-uk-5981963_1952358_1.webp?v=1771405047","url":"https:\/\/inspectec.co.nz\/products\/earth-tester-earth-resistance-meter-pce-ect-50-uk","provider":"Inspectec","version":"1.0","type":"link"}