{"product_id":"headspace-gas-analyzer-oxygen-carbon-dioxide-package-testing-instrument-hd-dk1-hd-dk2","title":"Headspace Gas Analyzer HD-DK2","description":"\u003ch2 data-start=\"361\" data-end=\"385\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp data-start=\"386\" data-end=\"691\"\u003eThe \u003cstrong data-start=\"390\" data-end=\"422\"\u003eHD-DK2 Residual Gas Analyzer\u003c\/strong\u003e is a professional handheld instrument designed to measure both \u003cstrong data-start=\"486\" data-end=\"526\"\u003eoxygen (O₂) and carbon dioxide (CO₂)\u003c\/strong\u003e content in sealed packaging. Using advanced \u003cstrong data-start=\"571\" data-end=\"611\"\u003eelectrochemical and infrared sensors\u003c\/strong\u003e, it provides precise results to ensure product quality and extend shelf life.\u003c\/p\u003e\n\u003cp data-start=\"693\" data-end=\"1021\"\u003eLightweight and portable, the HD-DK2 is equipped with a \u003cstrong data-start=\"749\" data-end=\"812\"\u003ebuilt-in pump, pressure sensor, and 6800mAh lithium battery\u003c\/strong\u003e for long-lasting field use. With \u003cstrong data-start=\"846\" data-end=\"872\"\u003e2000 data sets storage\u003c\/strong\u003e, USB export, and one-click calibration, it’s ideal for food, pharmaceutical, and packaging industries requiring reliable gas composition analysis.\u003c\/p\u003e\n\u003chr data-start=\"1023\" data-end=\"1026\"\u003e\n\u003ch2 data-start=\"1028\" data-end=\"1050\"\u003eApplication Scope\u003c\/h2\u003e\n\u003cul data-start=\"1051\" data-end=\"1409\"\u003e\n\u003cli data-start=\"1051\" data-end=\"1197\"\u003e\n\u003cp data-start=\"1053\" data-end=\"1197\"\u003e\u003cstrong data-start=\"1053\" data-end=\"1072\"\u003ePackaging bags:\u003c\/strong\u003e Coffee, cheese, milk tea, milk powder, bread, soy flour, MAP (modified atmosphere packaging), ready-to-eat foods, medicine\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1198\" data-end=\"1331\"\u003e\n\u003cp data-start=\"1200\" data-end=\"1331\"\u003e\u003cstrong data-start=\"1200\" data-end=\"1225\"\u003ePackaging containers:\u003c\/strong\u003e Canned coffee, canned milk powder, cheese, canned foods, Tetra Pak beverages, and other sealed packages\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1332\" data-end=\"1409\"\u003e\n\u003cp data-start=\"1334\" data-end=\"1409\"\u003e\u003cstrong data-start=\"1334\" data-end=\"1351\"\u003eExtended use:\u003c\/strong\u003e Measuring O₂ and CO₂ content at the top of \u003cstrong data-start=\"1395\" data-end=\"1407\"\u003eampoules\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1411\" data-end=\"1414\"\u003e\n\u003ch2 data-start=\"1416\" data-end=\"1433\"\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/H07c71c18ed584411af2efe6f7443507ey.jpg?v=1758763694\" alt=\"\"\u003e\u003c\/p\u003e\n\u003chr data-start=\"1680\" data-end=\"1683\"\u003e\n\u003ch2 data-start=\"1416\" data-end=\"1433\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1434\" data-end=\"2076\"\u003e\n\u003cli data-start=\"1434\" data-end=\"1494\"\u003e\n\u003cp data-start=\"1436\" data-end=\"1494\"\u003eHandheld, lightweight design for production site testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1495\" data-end=\"1571\"\u003e\n\u003cp data-start=\"1497\" data-end=\"1571\"\u003eQuick insertion sampling needle with protective cover for safe operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1572\" data-end=\"1621\"\u003e\n\u003cp data-start=\"1574\" data-end=\"1621\"\u003eDual gas detection: oxygen and carbon dioxide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1622\" data-end=\"1681\"\u003e\n\u003cp data-start=\"1624\" data-end=\"1681\"\u003eBuilt-in gas and pressure sensors for accurate analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1682\" data-end=\"1748\"\u003e\n\u003cp data-start=\"1684\" data-end=\"1748\"\u003eImported high-quality sensor components with long service life\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1749\" data-end=\"1815\"\u003e\n\u003cp data-start=\"1751\" data-end=\"1815\"\u003eOne-click operation, calibration, and intuitive user interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1816\" data-end=\"1858\"\u003e\n\u003cp data-start=\"1818\" data-end=\"1858\"\u003eRemote upgrade and maintenance support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1859\" data-end=\"1923\"\u003e\n\u003cp data-start=\"1861\" data-end=\"1923\"\u003eAutomatic shutdown, storage, and data memory to prevent loss\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1924\" data-end=\"1979\"\u003e\n\u003cp data-start=\"1926\" data-end=\"1979\"\u003eUp to 2000 data sets storage with USB import\/export\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1980\" data-end=\"2033\"\u003e\n\u003cp data-start=\"1982\" data-end=\"2033\"\u003e6800mAh lithium battery for extended portable use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2034\" data-end=\"2076\"\u003e\n\u003cp data-start=\"2036\" data-end=\"2076\"\u003eDual-language support: Chinese\/English\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2078\" data-end=\"2081\"\u003e\n\u003ch2 data-start=\"2083\" data-end=\"2112\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"2113\" data-end=\"2950\"\u003e\n\u003cli data-start=\"2113\" data-end=\"2147\"\u003e\n\u003cp data-start=\"2115\" data-end=\"2147\"\u003e\u003cstrong data-start=\"2115\" data-end=\"2134\"\u003eMeasured Gases:\u003c\/strong\u003e O₂ and CO₂\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2148\" data-end=\"2217\"\u003e\n\u003cp data-start=\"2150\" data-end=\"2217\"\u003e\u003cstrong data-start=\"2150\" data-end=\"2167\"\u003eSensor Types:\u003c\/strong\u003e Electrochemical (O₂), Infrared absorption (CO₂)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2218\" data-end=\"2265\"\u003e\n\u003cp data-start=\"2220\" data-end=\"2265\"\u003e\u003cstrong data-start=\"2220\" data-end=\"2240\"\u003eSampling Volume:\u003c\/strong\u003e \u0026lt;5ml (O₂), \u0026lt;15ml (CO₂)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2266\" data-end=\"2326\"\u003e\n\u003cp data-start=\"2268\" data-end=\"2326\"\u003e\u003cstrong data-start=\"2268\" data-end=\"2288\"\u003eSensor Lifespan:\u003c\/strong\u003e O₂ ~2 years (in air); CO₂ \u0026gt;15 years\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2327\" data-end=\"2384\"\u003e\n\u003cp data-start=\"2329\" data-end=\"2384\"\u003e\u003cstrong data-start=\"2329\" data-end=\"2351\"\u003eMeasurement Range:\u003c\/strong\u003e O₂: 0–30% VOL; CO₂: 0–100% VOL\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2385\" data-end=\"2414\"\u003e\n\u003cp data-start=\"2387\" data-end=\"2414\"\u003e\u003cstrong data-start=\"2387\" data-end=\"2402\"\u003eResolution:\u003c\/strong\u003e 0.01% VOL\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2415\" data-end=\"2490\"\u003e\n\u003cp data-start=\"2417\" data-end=\"2450\"\u003e\u003cstrong data-start=\"2417\" data-end=\"2430\"\u003eAccuracy:\u003c\/strong\u003e O₂: ≤ ±0.2%; CO₂:\u003c\/p\u003e\n\u003cul data-start=\"2453\" data-end=\"2490\"\u003e\n\u003cli data-start=\"2453\" data-end=\"2469\"\u003e\n\u003cp data-start=\"2455\" data-end=\"2469\"\u003e0–50%: ≤ ±2%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2472\" data-end=\"2490\"\u003e\n\u003cp data-start=\"2474\" data-end=\"2490\"\u003e50–100%: ≤ ±3%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2491\" data-end=\"2531\"\u003e\n\u003cp data-start=\"2493\" data-end=\"2531\"\u003e\u003cstrong data-start=\"2493\" data-end=\"2511\"\u003eResponse Time:\u003c\/strong\u003e O₂ ≤15s; CO₂ ≤20s\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2532\" data-end=\"2575\"\u003e\n\u003cp data-start=\"2534\" data-end=\"2575\"\u003e\u003cstrong data-start=\"2534\" data-end=\"2554\"\u003eSampling Method:\u003c\/strong\u003e Built-in pump type\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2576\" data-end=\"2621\"\u003e\n\u003cp data-start=\"2578\" data-end=\"2621\"\u003e\u003cstrong data-start=\"2578\" data-end=\"2598\"\u003eIntake Pressure:\u003c\/strong\u003e 700–1500 mbar (abs.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2622\" data-end=\"2671\"\u003e\n\u003cp data-start=\"2624\" data-end=\"2671\"\u003e\u003cstrong data-start=\"2624\" data-end=\"2647\"\u003eCalibration Method:\u003c\/strong\u003e Two-point calibration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2672\" data-end=\"2714\"\u003e\n\u003cp data-start=\"2674\" data-end=\"2714\"\u003e\u003cstrong data-start=\"2674\" data-end=\"2691\"\u003eData Storage:\u003c\/strong\u003e 2000 sets (circular)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2715\" data-end=\"2755\"\u003e\n\u003cp data-start=\"2717\" data-end=\"2755\"\u003e\u003cstrong data-start=\"2717\" data-end=\"2739\"\u003eData Transmission:\u003c\/strong\u003e USB interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2756\" data-end=\"2797\"\u003e\n\u003cp data-start=\"2758\" data-end=\"2797\"\u003e\u003cstrong data-start=\"2758\" data-end=\"2779\"\u003eBattery Capacity:\u003c\/strong\u003e 6800mAh lithium\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2798\" data-end=\"2835\"\u003e\n\u003cp data-start=\"2800\" data-end=\"2835\"\u003e\u003cstrong data-start=\"2800\" data-end=\"2826\"\u003eOperating Temperature:\u003c\/strong\u003e 0–40°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2836\" data-end=\"2885\"\u003e\n\u003cp data-start=\"2838\" data-end=\"2885\"\u003e\u003cstrong data-start=\"2838\" data-end=\"2852\"\u003eLanguages:\u003c\/strong\u003e Chinese \/ English (switchable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2886\" data-end=\"2928\"\u003e\n\u003cp data-start=\"2888\" data-end=\"2928\"\u003e\u003cstrong data-start=\"2888\" data-end=\"2908\"\u003eInstrument Size:\u003c\/strong\u003e 180 × 106 × 80 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2929\" data-end=\"2950\"\u003e\n\u003cp data-start=\"2931\" data-end=\"2950\"\u003e\u003cstrong data-start=\"2931\" data-end=\"2942\"\u003eWeight:\u003c\/strong\u003e 450 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2952\" data-end=\"2955\"\u003e\n\u003ch2 data-start=\"2957\" data-end=\"2974\"\u003eApplications\u003c\/h2\u003e\n\u003cp data-start=\"2975\" data-end=\"3006\"\u003eThe HD-DK2 is widely used in:\u003c\/p\u003e\n\u003cul data-start=\"3007\" data-end=\"3240\"\u003e\n\u003cli data-start=\"3007\" data-end=\"3048\"\u003e\n\u003cp data-start=\"3009\" data-end=\"3048\"\u003eFood packaging and shelf-life testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3049\" data-end=\"3121\"\u003e\n\u003cp data-start=\"3051\" data-end=\"3121\"\u003ePharmaceutical packaging validation (vials, ampoules, blister packs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3122\" data-end=\"3187\"\u003e\n\u003cp data-start=\"3124\" data-end=\"3187\"\u003eBeverage and dairy quality control (cans, bottles, Tetra Pak)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3188\" data-end=\"3240\"\u003e\n\u003cp data-start=\"3190\" data-end=\"3240\"\u003eWarehouses, production lines, and laboratory R\u0026amp;D\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1685\" data-end=\"1714\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/Hc0a26c77c73d4cb5b13a4986e4cf5116F.jpg?v=1758763757\" alt=\"\" style=\"font-size: 0.875rem;\"\u003e\u003c\/h2\u003e\n\u003ch6\u003e\u003cbr\u003e\u003c\/h6\u003e\n\u003ch6\u003eDownloads\u003c\/h6\u003e\n\u003cp\u003eData Sheet \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/Headspace_Gas_Analyzer.pdf?v=1758763549\"\u003eLink\u003c\/a\u003e\u003c\/p\u003e","brand":"HORDE","offers":[{"title":"Default Title","offer_id":48427366056165,"sku":"HD-DK2","price":5580.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/H1821351cc89b4a36b71a3121ddc4fc9dQ.jpg?v=1771408507","url":"https:\/\/inspectec.co.nz\/products\/headspace-gas-analyzer-oxygen-carbon-dioxide-package-testing-instrument-hd-dk1-hd-dk2","provider":"Inspectec","version":"1.0","type":"link"}