{"product_id":"lux-meter-pce-lxt","title":"Lux Meter PCE-LXT","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDescription\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eLux meter for fixed installation with relay output and control output\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv align=\"justify\"\u003e\n\u003cp\u003eThe lux warning system consists of a measuring sensor with a handle and a wall bracket with a 1.5 m cable, a light transmitter and a digital display. The main area of ​​application of this lux warning system is in the continuous light measurement and light monitoring of photo laboratories and production rooms (e.g. food or drug production ...). The digital display has a relay output for controlling alarm horns or flashing lights for optical or acoustic warning and a control output.\u003cbr\u003e\u003cbr\u003eThe alarm output limit can be programmed on the display. The analog output signal can also be used to control window flaps ... or the transmitter signals can be stored on a logger, evaluated and documented. The sound warning device is very easy to connect and can be operated via 240 V mains power.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe lux warning system was developed for continuous measurement of light intensity. The light transmitter and the digital display have standard dimensions and therefore fit into any control cabinet that has standardized slots. The lux warning system is particularly suitable for monitoring in companies that produce or store light-sensitive materials (e.g. photo laboratories, food production (storage), pharmaceutical production (storage) ... ).\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHighlights\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- For permanent installation\u003cbr\u003e- Relay output\u003cbr\u003e- Control output\u003cbr\u003e- Light measurement and monitoring\u003cbr\u003e- Optical or acoustic warning\u003cbr\u003e- Limit programming\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSpecification\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eLux sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0 ... 50000 lux in three areas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 lx \/ 1 lx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±5 % of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor\u003c\/td\u003e\n\u003ctd\u003ePhoto Diode with color correction filter according to C.I.E.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003evia transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable length (sensor to transmitter)\u003c\/td\u003e\n\u003ctd\u003e1.5 m \/ 4.9 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient conditions\u003c\/td\u003e\n\u003ctd\u003emax. 80 % relative humidity  \/ 0 ... +50 °C (32 ... 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing material\u003c\/td\u003e\n\u003ctd\u003eABS plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTransmitter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eABS plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e90 … 260 ACV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eadjustable via grub screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003e4 ... 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of protection\u003c\/td\u003e\n\u003ctd\u003eIP 54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient conditions\u003c\/td\u003e\n\u003ctd\u003emax. 85 % relative humidity \/ 0 ... +50 °C (32 ... 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDigital display\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput signal from the transmitter\u003c\/td\u003e\n\u003ctd\u003e4 – 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e-1999 ... 9999 (1 ... 3 decimal places, depending on the measured value \/ selectable by the user)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming data (decimal point, limit value...)\u003c\/td\u003e\n\u003ctd\u003eare stored in the device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl output\u003c\/td\u003e\n\u003ctd\u003e3-point (Com, NO, NC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm output\u003c\/td\u003e\n\u003ctd\u003erelay output: 5 A \/ 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e90 ... 260 ACV \/ 50 ... 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions \/ control panel cut-out according to DIN\u003c\/td\u003e\n\u003ctd\u003e92 (+0.8) mm x 45 (+0.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eca. 250 g \/ 8.8 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient conditions\u003c\/td\u003e\n\u003ctd\u003emax. 85 % relative humidity \/ 0 ... +50 °C (32 ... 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of protection\u003c\/td\u003e\n\u003ctd\u003eIP 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDelivery Scope\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Lux meter PCE-LXT\u003cbr\u003e1 x Lux sensor on 1.5 m (4.9 ft) cable\u003cbr\u003e1 x Light transmitter\u003cbr\u003e1 x Digital display device\u003cbr\u003e1 x Instruction manual\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-files\"\u003e\n\u003ch1 class=\"headline\"\u003eDownloads\u003c\/h1\u003e\n\u003cdiv class=\"pkdownloads\"\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/www.pce-instruments.com\/english\/api\/getartfile?_fnr=1005196\u0026amp;_dsp=inline\" target=\"_blank\"\u003e\u003cbr\u003e\u003cspan class=\"mimetitle mimetitlet_custom_manual mimetitlel_EN\"\u003eManual\u003c\/span\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"PCE","offers":[{"title":"Without Calibration Certificate","offer_id":48427446829285,"sku":"lxt","price":1320.0,"currency_code":"NZD","in_stock":true},{"title":"With Calibration Certificate","offer_id":48427446862053,"sku":"PCE-LXT-2","price":1900.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-lux-meter-pce-lxt-58481_1962546.webp?v=1771409563","url":"https:\/\/inspectec.co.nz\/products\/lux-meter-pce-lxt","provider":"Inspectec","version":"1.0","type":"link"}