{"product_id":"mitech-industrial-x-ray-led-film-viewer-mg200","title":"Industrial X-Ray Film Viewer MG200","description":"\u003cp data-start=\"187\" data-end=\"603\"\u003eThe Mitech MG200 Portable Industrial LED Film Viewer is a precision-engineered solution designed for high-resolution evaluation of X-ray films in nondestructive testing (NDT) environments. With a high-power LED surface light source, durable acrylic viewing screen, and adjustable brightness control, this compact viewer delivers optimal clarity, reliability, and ease of use for radiographic film interpretation.\u003c\/p\u003e\n\u003cp data-start=\"605\" data-end=\"928\"\u003eEngineered to meet international NDT standards, the MG200 offers a bright, uniform illumination surface, capable of detecting flaws on films with blackness levels above 4.5D. Its robust structure, dual control modes (pedal\/manual), and efficient heat dissipation make it ideal for fieldwork and laboratory inspection alike.\u003c\/p\u003e\n\u003ch2 data-start=\"935\" data-end=\"954\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"956\" data-end=\"1921\"\u003e\n\u003cli data-start=\"956\" data-end=\"1073\"\u003e\n\u003cp data-start=\"958\" data-end=\"1073\"\u003eHigh Brightness LED Source: Delivers ≥100,000 Cd\/m² with excellent uniformity for high-resolution film viewing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1074\" data-end=\"1185\"\u003e\n\u003cp data-start=\"1076\" data-end=\"1185\"\u003eSupports High-Density Films: Accurately displays defects on X-ray films with blackness greater than 4.5D.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1186\" data-end=\"1297\"\u003e\n\u003cp data-start=\"1188\" data-end=\"1297\"\u003eUniform Illumination: Uniformity coefficient ≥0.9 ensures even brightness across the entire viewing area.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1298\" data-end=\"1416\"\u003e\n\u003cp data-start=\"1300\" data-end=\"1416\"\u003eAdjustable Brightness: Stepless dimming with electronic pulse width modulation enhances user control and safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1417\" data-end=\"1521\"\u003e\n\u003cp data-start=\"1419\" data-end=\"1521\"\u003eDurable Acrylic Screen: High-diffusion yakeli board ensures bright and consistent light diffusion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1522\" data-end=\"1630\"\u003e\n\u003cp data-start=\"1524\" data-end=\"1630\"\u003eComfortable Viewing: LED color temperature limited to 8000K to reduce eye strain during long sessions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1631\" data-end=\"1705\"\u003e\n\u003cp data-start=\"1633\" data-end=\"1705\"\u003eConstant Current Drive: Extends LED service life up to 50,000 hours.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1706\" data-end=\"1810\"\u003e\n\u003cp data-start=\"1708\" data-end=\"1810\"\u003eDual Operation Modes: Switch easily between manual and foot-pedal control to suit user preference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1811\" data-end=\"1921\"\u003e\n\u003cp data-start=\"1813\" data-end=\"1921\"\u003eCompliant with Standards: Meets JB\/T 4730-2005 and GB\/T 19802-2005 for industrial radiography equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1928\" data-end=\"1947\"\u003eApplications\u003c\/h2\u003e\n\u003cp data-start=\"1949\" data-end=\"1985\"\u003eIdeal for X-ray film observation in:\u003c\/p\u003e\n\u003cul data-start=\"1987\" data-end=\"2226\"\u003e\n\u003cli data-start=\"1987\" data-end=\"2028\"\u003e\n\u003cp data-start=\"1989\" data-end=\"2028\"\u003eIndustrial Nondestructive Testing (NDT)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2029\" data-end=\"2071\"\u003e\n\u003cp data-start=\"2031\" data-end=\"2071\"\u003eRadiographic Inspection in Manufacturing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2072\" data-end=\"2119\"\u003e\n\u003cp data-start=\"2074\" data-end=\"2119\"\u003ePower Plant and Pressure Equipment Evaluation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2120\" data-end=\"2172\"\u003e\n\u003cp data-start=\"2122\" data-end=\"2172\"\u003eAerospace, Petrochemical, and Shipbuilding Sectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2173\" data-end=\"2226\"\u003e\n\u003cp data-start=\"2175\" data-end=\"2226\"\u003eOn-site Film Review and Mobile Testing Environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"2233\" data-end=\"2264\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable data-start=\"2266\" data-end=\"3625\"\u003e\n\u003cthead data-start=\"2266\" data-end=\"2351\"\u003e\n\u003ctr data-start=\"2266\" data-end=\"2351\"\u003e\n\u003cth data-start=\"2266\" data-end=\"2310\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2310\" data-end=\"2351\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2437\" data-end=\"3625\"\u003e\n\u003ctr data-start=\"2437\" data-end=\"2521\"\u003e\n\u003ctd data-start=\"2437\" data-end=\"2480\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"2480\" data-end=\"2521\"\u003eMitech\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2522\" data-end=\"2606\"\u003e\n\u003ctd data-start=\"2522\" data-end=\"2565\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"2565\" data-end=\"2606\"\u003eMG200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2607\" data-end=\"2691\"\u003e\n\u003ctd data-start=\"2607\" data-end=\"2650\"\u003eMaximum Brightness\u003c\/td\u003e\n\u003ctd data-start=\"2650\" data-end=\"2691\"\u003e≥100,000 Cd\/m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2692\" data-end=\"2776\"\u003e\n\u003ctd data-start=\"2692\" data-end=\"2735\"\u003eMaximum Observable Blackness\u003c\/td\u003e\n\u003ctd data-start=\"2735\" data-end=\"2776\"\u003e＞4.5D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2777\" data-end=\"2861\"\u003e\n\u003ctd data-start=\"2777\" data-end=\"2820\"\u003eUniformity Coefficient\u003c\/td\u003e\n\u003ctd data-start=\"2820\" data-end=\"2861\"\u003e≥0.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2862\" data-end=\"2946\"\u003e\n\u003ctd data-start=\"2862\" data-end=\"2905\"\u003eScattering Coefficient\u003c\/td\u003e\n\u003ctd data-start=\"2905\" data-end=\"2946\"\u003e≥0.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2947\" data-end=\"3031\"\u003e\n\u003ctd data-start=\"2947\" data-end=\"2990\"\u003eViewing Window Size\u003c\/td\u003e\n\u003ctd data-start=\"2990\" data-end=\"3031\"\u003e400 × 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3032\" data-end=\"3116\"\u003e\n\u003ctd data-start=\"3032\" data-end=\"3075\"\u003eRated Power\u003c\/td\u003e\n\u003ctd data-start=\"3075\" data-end=\"3116\"\u003e200W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3117\" data-end=\"3201\"\u003e\n\u003ctd data-start=\"3117\" data-end=\"3160\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3160\" data-end=\"3201\"\u003eAC170–250V, 47–63Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3202\" data-end=\"3285\"\u003e\n\u003ctd data-start=\"3202\" data-end=\"3245\"\u003eContinuous Operation Time\u003c\/td\u003e\n\u003ctd data-start=\"3245\" data-end=\"3285\"\u003eUp to 12 hours (≤40°C surface temp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3286\" data-end=\"3370\"\u003e\n\u003ctd data-start=\"3286\" data-end=\"3329\"\u003eColour Temperature\u003c\/td\u003e\n\u003ctd data-start=\"3329\" data-end=\"3370\"\u003e8000K (eye-comfort limit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3371\" data-end=\"3455\"\u003e\n\u003ctd data-start=\"3371\" data-end=\"3414\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-start=\"3414\" data-end=\"3455\"\u003e550 × 150 × 200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3456\" data-end=\"3540\"\u003e\n\u003ctd data-start=\"3456\" data-end=\"3499\"\u003eTotal Weight\u003c\/td\u003e\n\u003ctd data-start=\"3499\" data-end=\"3540\"\u003e6.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3541\" data-end=\"3625\"\u003e\n\u003ctd data-start=\"3541\" data-end=\"3584\"\u003eLED Lifetime\u003c\/td\u003e\n\u003ctd data-start=\"3584\" data-end=\"3625\"\u003eUp to 50,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 data-start=\"3632\" data-end=\"3656\"\u003eWorking Principle\u003c\/h2\u003e\n\u003cp data-start=\"3658\" data-end=\"4043\"\u003eThe MG200 operates by illuminating X-ray films placed on the yakeli observation screen using a high-intensity LED light source. The light passes through the film, revealing internal structures and flaws in the material. The viewer’s consistent and bright illumination ensures clear detection of flaws, supporting precise assessment and quality control in accordance with NDT standards.\u003c\/p\u003e\n\u003ch2 data-start=\"4050\" data-end=\"4073\"\u003eUsage Conditions\u003c\/h2\u003e\n\u003cul data-start=\"4075\" data-end=\"4230\"\u003e\n\u003cli data-start=\"4075\" data-end=\"4120\"\u003e\n\u003cp data-start=\"4077\" data-end=\"4120\"\u003eOperating Temperature: -10°C to +45°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4121\" data-end=\"4152\"\u003e\n\u003cp data-start=\"4123\" data-end=\"4152\"\u003eRelative Humidity: ≤85%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4153\" data-end=\"4230\"\u003e\n\u003cp data-start=\"4155\" data-end=\"4230\"\u003eEnvironment: Free from corrosive gases and strong magnetic interference\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"4237\" data-end=\"4270\"\u003eSafety \u0026amp; Maintenance Notes\u003c\/h2\u003e\n\u003cul data-start=\"4272\" data-end=\"4735\"\u003e\n\u003cli data-start=\"4272\" data-end=\"4341\"\u003e\n\u003cp data-start=\"4274\" data-end=\"4341\"\u003eAlways read the user manual before operating to avoid improper use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4342\" data-end=\"4425\"\u003e\n\u003cp data-start=\"4344\" data-end=\"4425\"\u003eDo not block ventilation outlets—this prevents overheating and equipment failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4426\" data-end=\"4480\"\u003e\n\u003cp data-start=\"4428\" data-end=\"4480\"\u003eAvoid strong shocks and vibrations during transport.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4481\" data-end=\"4549\"\u003e\n\u003cp data-start=\"4483\" data-end=\"4549\"\u003eGently handle accessories; avoid excessive force or harsh pulling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4550\" data-end=\"4635\"\u003e\n\u003cp data-start=\"4552\" data-end=\"4635\"\u003eAfter use, store the shade and other components properly to prevent loss or damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4636\" data-end=\"4735\"\u003e\n\u003cp data-start=\"4638\" data-end=\"4735\"\u003eDo not disassemble the unit without authorisation—contact MITECH support for service and repairs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDownloads\u003c\/p\u003e\n\u003cp data-start=\"4760\" data-end=\"4825\"\u003ePDF Specification Sheet – \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/MG200_catalog_d64d0516-15aa-4bf7-8820-fe4a053aa202.pdf?v=1744706999\" target=\"_blank\" rel=\"noopener\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e","brand":"Mitech","offers":[{"title":"Default Title","offer_id":48427031593189,"sku":null,"price":2040.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/1511732953065084808.png?v=1771403703","url":"https:\/\/inspectec.co.nz\/products\/mitech-industrial-x-ray-led-film-viewer-mg200","provider":"Inspectec","version":"1.0","type":"link"}