{"product_id":"turbidity-meter-photometer-pce-tum-51","title":"Portable Turbidity Meter PCE-TUM 50","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDescription\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e\u003cstrong\u003eTurbidity meter PCE-TUM 50\u003cbr\u003eTurbidity meter for drinking and waste water as well as food \/ Colored graphic display \/ Measurement of NTU, EBC, ASBC \/ According to ISO 7027 (90°) \/ AC Mains operation (220V AC power adapter) \/ USB interface\u003c\/strong\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv\u003eThe turbidity meter PCE-TUM 50 is a portable device for measuring turbidity according to ISO 7027. This allows the user to quickly and easily determine important water parameters with the turbidity meter and to check the quality of drinking water and waste water. The calibration of the turbidity meter PCE-TUM 50 is very easy due to the calibration standards supplied. The calibration can be carried out with 7 preset points. In addition, user-specific calibration points can also be set. The turbidity meter is capable of measuring turbidity of liquids up to 2000 NTU.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eFurthermore, the measuring unit can be switched to EBC (European Brewery Convention) or ASBC (American Society of Brewing Chemists). The measured values are displayed on the large color display. The turbidity meter is mainly used in the laboratory and is therefore operated with a plug-in power supply. Via the rear USB interface, the turbidity meter can be connected to a computer and the memory can be cleared.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eWhat is the EBC or European Brewery Convention? (See above in the picture gallery) As EBC, the color or the color intensity of beer and wort is described in Europe. This set value describes how much light is absorbed by beer with a certain original wort content. The turbidity meter can determine this value and thus helps in judging the type of beer.\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHighlights\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- High precision\u003cbr\u003e- 3 measuring units\u003cbr\u003e- Turbidity calibration up to 7 points\u003cbr\u003e- Color display\u003cbr\u003e- Easy handling\u003cbr\u003e- USB interface\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSpecification\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable cellspacing=\"0\" border=\"0\" bgcolor=\"#FFFFFF\"\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eMeasurement method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eISO 7027 (90°)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eMeasuring ranges\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0 ... 2000 NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0 ... 500 EBC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0 ... 9999 ASBC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e\u0026lt; 100 NTU: 0.01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e\u0026lt; 999 NTU: 0.1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e\u0026lt; 2000 NTU: 1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cspan\u003e\u0026lt; 500 NTU: ± 2% of \u003c\/span\u003emeasured value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cspan\u003e\u0026lt; 2000 NTU: ± 3% of \u003c\/span\u003emeasured value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eCalibration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e\u0026lt; 0.02 NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e10 NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e200 NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e500 NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e1000 NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e1500 NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e2000 NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eOr user-specific\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eLight source\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e850 nm IR LED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eScattered light influence         \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e\u0026lt; 0.02 NTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eDimensions of cuvettes   \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e60 x 25 mm \/ 2.4 x 1 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cspan\u003eAutomatic shutdown\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e2 hours after the device was not used\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eStorage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e200 memory slots\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cspan\u003eInterface\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eUSB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003ePower supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e220 VAC\/50 Hz, 12 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eCurrent consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eAbout 300-mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eOperating temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cspan\u003e0 ... 60°C \/ 32 ... 140\u003c\/span\u003e°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e250 x 177 x 96 mm \/ 9.8 x 7 x 3.8 in \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eAbout 1.2 kg \/ 2.6 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDelivery Scope\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Turbidity meter PCE-TUM 50\u003cbr\u003e1 x Cuvette with lid\u003cbr\u003e4 x Calibration cuvettes turbidity\u003cbr\u003e1 x AC Power adapter\u003cbr\u003e1 x Cleaning cloth\u003cbr\u003e1 x User manual\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-files\"\u003e\n\u003ch1 class=\"headline\"\u003eDownloads\u003c\/h1\u003e\n\u003cdiv class=\"pkdownloads\"\u003e\n\u003cdiv\u003e\n\u003ca class=\"\" href=\"https:\/\/www.pce-instruments.com\/english\/api\/getartfile?_fnr=1572701\u0026amp;_dsp=inline\" target=\"_blank\"\u003e\u003cbr\u003e\u003cspan class=\"mimetitle mimetitlet_custom_manual mimetitlel_EN\"\u003eManual\u003c\/span\u003e\u003c\/a\u003e\u003ca class=\"\" href=\"https:\/\/www.pce-instruments.com\/english\/api\/getartfile?_fnr=1648000\u0026amp;_dsp=inline\" target=\"_blank\"\u003e\u003cbr\u003e\u003cspan class=\"mimetitle mimetitlet_custom_datasheet mimetitlel_EN\"\u003eDatasheet\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Inspection Tool Specialists","offers":[{"title":"Default Title","offer_id":48427351867621,"sku":"PCE-TUM 50","price":2760.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-turbidity-meter-pce-tum-50-5928316_1354256_10c893dc-df71-4803-928c-7448bfc902b8.webp?v=1771407766","url":"https:\/\/inspectec.co.nz\/products\/turbidity-meter-photometer-pce-tum-51","provider":"Inspectec","version":"1.0","type":"link"}