{"product_id":"ultrasonic-flaw-detector-mfd550b-copy","title":"Ultrasonic Flaw Detector \u0026 Thickness Gauge | A-Scan \/ B-Scan Inspection Instrument PCE-FD 20","description":"\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003ch1 class=\"headline\"\u003eDescription\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003ePCE-FD 20 is a portable ultrasonic tester or ultrasonic thickness gauge with a large LCD screen that displays A-scan maps of ultrasonic signals as well as B-scan cross sections. Ideal for use in mechanical engineering, aerospace and metallurgical applications, this high-frequency ultrasound-based thickness meter uses a contact transducer (two different probes included; 45° and 90°) to measure material thickness and identify flaws and defects such as discontinuity in welds.\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-customdata2\" class=\"tab-pane clear fade in\"\u003e\n\u003ch1 class=\"headline\"\u003eHighlights\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Operating frequency range: 1 ... 10 MHz\u003cbr\u003e- Measured time interval range: 6 ... 1000 microseconds (µs)\u003cbr\u003e- Sound velocity: 1000 ... 9999 m\/s\u003cbr\u003e- Implements shadow, echo and mirror-shadow testing methods\u003cbr\u003e- Features a USB interface for downloading data to PC for detailed analysis\u003cbr\u003e- Lightweight\u003cbr\u003e- Battery or electric power\u003cbr\u003e- 1.5 m long probe cable\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-customdata3\" class=\"tab-pane clear fade in\"\u003e\n\u003ch1 class=\"headline\"\u003eSpecification\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable height=\"0\" width=\"100%\" cellspacing=\"1\" cellpadding=\"0\" bgcolor=\"#FFFFFF\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cbr\u003eTechnical specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable border=\"0\" class=\"tech\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech\" height=\"18\" width=\"50%\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003eOperating frequency range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"tech\" align=\"center\" width=\"50%\" height=\"18\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003e1 ... 10 MHz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech\" height=\"18\" width=\"50%\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003eMeasure time interval range (scan duration)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"tech\" align=\"center\" width=\"50%\" height=\"18\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003e6 ... 1000 microseconds (µs)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech\" height=\"18\" width=\"50%\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003eSound velocity range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"tech\" align=\"center\" width=\"50%\" height=\"18\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003e1000 ... 9999 m\/s\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech\" height=\"18\" width=\"50%\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003eDeviation of measurement of time intervals\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"tech\" align=\"center\" width=\"50%\" height=\"18\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003eNot exceed ± 0.025 µs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech\" height=\"18\" width=\"50%\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003eMax. deviation of amplitude of signals at receiver input in 0 ... 110 dB range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"tech\" align=\"center\" width=\"50%\" height=\"18\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003eNot exceed ± 0.5 dB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech\" height=\"18\" width=\"50%\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003eTesting gain region\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"tech\" width=\"50%\" height=\"18\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003e125 dB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech\" height=\"18\" width=\"50%\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003eAveraging over the quantity of starts\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"tech\" width=\"50%\" height=\"18\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003e1 ... 16\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech\" height=\"18\" width=\"50%\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003eRange of time-variable gain (TVG) \/ Number of control points TVG\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"tech\" width=\"50%\" height=\"18\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003e40 dB \/ 15\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech\" height=\"18\" width=\"50%\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003eDuration of excitation pulse to load\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"tech\" width=\"50%\" height=\"18\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003e0 ... 0.5 µs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech\" height=\"18\" width=\"50%\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003eAmplitude of excitation pulse to 50 Ohm load, not less\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"tech\" width=\"50%\" height=\"18\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003e100, 200, 300\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech\" height=\"18\" width=\"50%\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003eOperating frequency range of receiver at -3 dB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"tech\" width=\"50%\" height=\"18\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003e1 ... 10 MHz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech\" height=\"18\" width=\"50%\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003eDeviation of amplitudes of input signals in 10 ... 100% range of screen height\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"tech\" width=\"50%\" height=\"18\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003eNot more than 1 dB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech\" height=\"18\" width=\"50%\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003eScanning\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"tech\" width=\"50%\" height=\"18\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003e1 ... 1000 µs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech\" height=\"18\" width=\"50%\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003eScanning delay\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"tech\" width=\"50%\" height=\"18\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003e0 ... 2000 µs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech\" height=\"18\" width=\"50%\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003eMeasurement range of time intervals\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"tech\" width=\"50%\" height=\"18\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003e0 ... 1000 µs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech\" height=\"18\" width=\"50%\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003ePrism of probe delay\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"tech\" width=\"50%\" height=\"18\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003e0 ... 15 µs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech\" height=\"18\" width=\"50%\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003eAutomatic signaling of defects (AFS)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"tech\" width=\"50%\" height=\"18\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003eDual-gate\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech\" height=\"18\" width=\"50%\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003eSetting range of AFS gates\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"tech\" width=\"50%\" height=\"18\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003e0 ... 2000 µs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech\" height=\"18\" width=\"50%\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003eAdjusting thresholds of AFS gates\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"tech\" width=\"50%\" height=\"18\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003e0 ... 100%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech\" height=\"18\" width=\"50%\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003eDetection of signals (receiver)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"tech\" align=\"center\" width=\"50%\" height=\"18\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003ePositive half-wave, radio mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech\" height=\"18\" width=\"50%\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003eDimensions of device (approx.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"tech\" align=\"center\" width=\"50%\" height=\"18\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003e80 x 162 x 35 mm \/ 3.14 x 6.37 x 1.37\"\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech\" height=\"18\" width=\"50%\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003eDimensions display (approx.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"tech\" align=\"center\" width=\"50%\" height=\"18\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003e48 x 74 mm \/ 1.88 x 2.91\"\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech\" height=\"18\" width=\"50%\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003ePower supply\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"tech\" align=\"center\" width=\"50%\" height=\"18\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003e100 ... 250 V AC or 3 x 1.5 V AA batteries\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech\" height=\"18\" width=\"50%\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003eWeight (approx.)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"tech\" align=\"center\" width=\"50%\" height=\"18\" valign=\"top\"\u003e\n\u003cp align=\"left\"\u003e250 g \/ 0.55 lb (without batteries)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" height=\"28\" valign=\"top\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-customdata4\" class=\"tab-pane clear fade in\"\u003e\n\u003ch1 class=\"headline\"\u003eDelivery Scope\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x PCE-FD 20 thickness meter\u003cbr\u003e1 x probe cable (1.5 m long)\u003cbr\u003e1 x contact transducer probe (90 °)\u003cbr\u003e1 x contact transducer probe (45 °)\u003cbr\u003e3 x 1.5 V batteries (AA)\u003cbr\u003e1 x battery charger \/ electric power supply\u003cbr\u003e1 x USB cable\u003cbr\u003e1 x user manual\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-files\" class=\"tab-pane clear fade in\"\u003e\n\u003ch1 class=\"headline\"\u003eDownloads\u003c\/h1\u003e\n\u003cdiv class=\"pkdownloads\"\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/www.pce-instruments.com\/english\/api\/getartfile?_fnr=1002286\u0026amp;_dsp=inline\" class=\"\" target=\"_blank\"\u003e\u003cbr\u003e\u003cspan class=\"mimetitle mimetitlet_custom_manual mimetitlel_EN\"\u003eManual\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.pce-instruments.com\/english\/api\/getartfile?_fnr=1547970\u0026amp;_dsp=inline\" class=\"\" target=\"_blank\"\u003e\u003cbr\u003e\u003cspan class=\"mimetitle mimetitlet_custom_datasheet mimetitlel_EN\"\u003eDatasheet\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":50322410995941,"sku":null,"price":101481.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0702\/1687\/6261\/files\/pce-instruments-thickness-meter-pce-fd-20-5790590_960303.webp?v=1784245917","url":"https:\/\/inspectec.co.nz\/products\/ultrasonic-flaw-detector-mfd550b-copy","provider":"Inspectec","version":"1.0","type":"link"}